Commission Delegated Regulation (EU) 2022/759 of 14 December 2021 amending Annex VII to Directive (EU) 2018/2001 of the European Parliament and of the Council as regards a methodology for calculating the amount of renewable energy used for cooling and district cooling
THE EUROPEAN COMMISSION,
Having regard to the Treaty on the Functioning of the European Union,
Having regard to Directive (EU) 2018/2001 of the European Parliament and of the Council of 11 December 2018 on the promotion of the use of energy from renewable sources (1), and in particular Article 7(3),, fifth subparagraph thereof,
Whereas:
(1) Annex VII to Directive (EU) 2018/2001 provides a methodology to calculate renewable energy from heat pumps used for heating, but does not regulate how to calculate renewable energy from heat pumps used for cooling. The lack of methodology in that Annex to calculate renewable energy from heat pumps used for cooling prevents the cooling sector from contributing to the Union’s overall renewable energy target laid down in Article 3 of Directive (EU) 2018/2001 and makes it more difficult for Member States, especially those with a high cooling share in their energy consumption, to deliver the heating and cooling target and district heating and cooling targets under Articles 23 and 24 of that Directive, respectively.
(2) Therefore a methodology on renewable cooling, including district cooling, should be introduced in Annex VII to Directive (EU) 2018/2001. Such a methodology is necessary to ensure that the renewable energy share from cooling is calculated in a harmonised way in all Member States and to make a reliable comparison of all cooling systems in terms of their capacity to use renewable energy for cooling possible.
(3) The methodology should include minimum seasonal performance factors (SPF) for heat pumps operating in reverse mode in accordance with Article 7(3), sixth subparagraph of Directive (EU) 2018/2001. Since all active cooling systems can be considered as heat pumps working in reverse mode, so-called ‘cooling mode’, minimum seasonal performance factors should apply to all cooling systems. This is necessary because heat pumps extract and transfer heat from one location to another. In the case of cooling, heat pumps extract heat from a space or process and reject it to the environment (air, water or ground). Extraction of heat is the essence of cooling and the core function of a heat pump. Since this extraction goes against the natural flow of energy, which goes from hot to cold, such extraction requires energy input to the heat pump, which works as a cooling generator.
(4) The mandatory inclusion of minimum seasonal performance factors in the methodology is due to the importance of energy efficiency to establish the presence and use of renewable energy by heat pumps. The renewable energy in the case of cooling is the renewable cold source, which can increase the efficiency of the cooling process, and makes the seasonal performance factor of cooling higher. High seasonal performance factors, while being an energy efficiency indicator, function at the same time as proxy for the presence and use of renewable cold source in cooling.
(5) In cooling, the cold source functions as a heat sink, as it absorbs the heat extracted and rejected by the heat pump outside the space or process that needs to be cooled. The quantity of renewable cooling depends on the efficiency of the cooling process, and is equivalent to the quantity of heat absorbed by the heat sink. This in practice is equivalent to the quantity of cooling capacity provided by the cold source.
(6) The cold source can be ambient energy or geothermal energy. Ambient energy is present in ambient air (formerly known as aerothermal) and ambient water (formerly known as hydrothermal), while geothermal energy comes from the ground under the surface of solid earth. Ambient and geothermal energy used for cooling by means of heat pumps and district cooling systems should be taken into account for the purposes of calculating the share of renewable energy in the gross final consumption of energy, provided that the final energy output significantly exceeds the primary energy input required to drive the heat pumps. This requirement, established in Article 7(3), third subparagraph of Directive (EU) 2018/2001, could be fulfilled with appropriately high seasonal performance factors as defined by the methodology.
(7) Given the variety of cooling solutions, it is necessary to define which cooling solutions should fall into the scope of the methodology and which should be excluded. Cooling by the natural flow of thermal energy without the intervention of a cooling device is passive cooling and should therefore be excluded from the scope of the calculation in accordance with Article 7(3), fourth subparagraph of Directive (EU) 2018/2001.
(8) Decreasing the need for cooling by building design, such as building insulation, green roof, vegetal wall, and shading or increased building mass, while valuable, can be considered as a passive cooling and should therefore not be included in the scope of the renewable cooling calculation.
(9) Ventilation (either natural or forced), which is the introduction of ambient air inside a space with the aim to ensure appropriate indoor air quality is considered passive cooling and should therefore not be included in the scope of the renewable calculation. This exclusion should be maintained even when ventilation leads to the introduction of cold ambient air and thus reduces the cooling supply in some periods of the year; indeed, this cooling is not the primary function and ventilation may also contribute to heating the air in the summer and thus to increase the cooling load. Notwithstanding, where ventilation air is used as a heat transport medium for cooling, the corresponding cooling supply, which can be supplied either by a cooling generator or by free cooling, should be considered active cooling. In situations where the ventilation airflow is increased above ventilation requirements for cooling purposes, the cooling supply due to this extra airflow should be part of the renewable cooling calculation.
(10) Comfort fan products include a fan and electric motor assembly. Comfort fans move air and provide summer comfort by increasing the air speed around the human body, which gives a thermal feeling of coolness. As opposed to ventilation, there is no introduction of ambient air in the case of comfort fans; comfort fans only move indoor air. Consequently, they are not cooling indoor air but heating it (all electricity consumed is ultimately released as heat in the room where the comfort fan is used). Comfort fans are not cooling solutions and should therefore fall outside the scope of the renewable cooling calculation.
(11) Cooling system energy input in means of transportation (such as cars, trucks, ships) is in general supplied by the transportation engine. The use of renewable energy in non-stationary cooling is part of the renewable transport target calculation pursuant to Article 7(1), point (c) of Directive (EU) 2018/2001 and should therefore not fall into the scope of the renewable cooling calculation.
(12) The temperature range of the cooling supply for which renewable cold sources can grow, and reduce or displace the energy use of a cooling generator lays between 0 °C and 30 °C. This temperature range is one of the parameters that should be used to screen potential cooling process sectors and applications to be included in the scope of the renewable cooling calculation.
(13) Process cooling with low and very low cooling supply temperature has little room to use renewable cold sources to any significant degree and is mostly operated with electrically driven refrigeration. The main way of making refrigeration equipment renewable is through their energy input. When electricity driven refrigeration equipment is renewable, it is already accounted for in the renewable electricity shares under Directive (EU) 2018/2001. The efficiency improvement potential is already covered by the EU ecodesign and labelling framework. Consequently, there would be no benefit of including refrigeration equipment in the scope of the renewable cooling calculation.
(14) As regards high temperature process cooling, any thermal power plant, combustion and other high temperature processes offer the possibility to recover waste heat. Incentivising the release of high temperature waste heat into the environment without heat recovery through renewable cooling would be against the ‘energy efficiency first’ principle and environmental protection. In that perspective, the 30 °C temperature limit is not enough to distinguish those processes; indeed, in a steam power plant, condensation may occur at 30 °C or lower. The cooling system of the power plant may supply cooling at a temperature lower than 30 °C.
(15) To ensure that the scope is clearly set, the methodology should include a list of processes where the recovery or avoidance of waste heat should be prioritised instead of incentivising the use of cooling. Sectors where waste heat avoidance and recovery is promoted through Directive 2012/27/EU of the European Parliament and of the Council (2) include power generation plants, including cogeneration, and processes producing hot fluids from combustion or from an exothermic chemical reaction. Additional processes where waste heat avoidance and recovery is important include cement, iron and steel manufacturing, wastewater treatment plants, information technology facilities such as data centres, power transmission and distribution facilities, as well as cremation and transportation infrastructures, where cooling should not be promoted for mitigating waste heat resulting from these processes.
(16) A central parameter for the calculations of renewable energy from heat pump used for cooling is the seasonal performance factor calculated in primary energy, denoted as the SPFp. SPFp is a ratio expressing the efficiency of cooling systems during the cooling season. It is calculated by dividing the produced quantity of cooling with the energy input. Higher SPFp is better, because more cooling is produced for the same energy input.
(17) To calculate the quantity of renewable energy from cooling, it is necessary to define the share of the cooling supply that can be considered renewable. This share is denoted as sSPFp. The sSPFp is a function of a low and high SPFp threshold value. The methodology should set a low SPFp threshold value below which renewable energy from a cooling system is zero. The methodology should also set a high SPFp threshold value above which the entire cooling supply produced by a cooling system counts as renewable. A progressive calculation method should allow calculating the linearly growing portion of the cooling supply that can be counted as renewable from cooling systems with SPFp values falling between the low and high SPFp thresholds.
(18) The methodology should ensure that, in accordance with Article 7(1), second subparagraph of Directive (EU) 2018/2001, gas, electricity, and hydrogen from renewable sources are considered only once for the purposes of calculating the share of gross final consumption of energy from renewable sources.
(19) To ensure stability and predictability from the application of the methodology for the cooling sector, the low and high threshold SPF values calculated in primary energy terms should be set using the default coefficient, also called primary energy factor, as set in Directive 2012/27/EU.
(20) It is appropriate to distinguish between different approaches to calculating renewable cooling depending on the availability of standard values for the parameters needed in the calculation, such as standard seasonal performance factors or equivalent full load hours of operation.
(21) It is appropriate that the methodology allows the use of a simplified statistical approach based on standard values for installations smaller than 1.5 MW nominal capacity. Where standard values are not available, the methodology should make it possible to use measured data to allow cooling systems to benefit from the calculation methodology of renewable energy from cooling. The measurement approach should apply to cooling systems with a nominal capacity above 1.5 MW, for district cooling and for small systems using technologies where standard values are not available. Notwithstanding the availability of standard values, Member States may use measured data for all cooling systems.
(22) Member States should be allowed to undertake their own calculations and surveys in order to improve the accuracy of national statistics beyond what is feasible with the methodology set out in this Regulation.
(23) Annex VII to Directive (EU) 2018/2001 should therefore be amended accordingly,
HAS ADOPTED THIS REGULATION:
Article 1
Amendment
Annex VII to Directive (EU) 2018/2001 is replaced by the Annex to this Regulation.
Article 2
Review
The Commission shall review this Regulation in the light of technological progress and innovation, the stock deployment, and its impacts on the renewable energy targets.
Article 3
Entry into force
This Regulation shall enter into force on the twentieth day following that of its publication in the Official Journal of the European Union.
This Regulation shall be binding in its entirety and directly applicable in all Member States.
Done at Brussels, 14 December 2021.
For the Commission The President Ursula VON DER LEYEN