Commission Implementing Regulation (EU) 2023/1162 of 6 June 2023 on interoperability requirements and non-discriminatory and transparent procedures for access to metering and consumption data (Text with EEA relevance)

Type Implementing Regulation
Publication 2023-06-15
State In force
Text As published
Department European Commission, ENER
Source EUR-Lex
articles 15

This is the act as published. Later amendments are not folded into the text below: each one is a separate act in this repository and an entry in this law's history.

Reform history JSON API
Procedure name Procedure name Revocation of an active permission by the final customer Revocation of an active permission by the final customer Revocation of an active permission by the final customer Revocation of an active permission by the final customer
Step No Step Step description Information producer Information receiver Information exchanged (IDs)
4.1 Identify permission administrator Final customers identify the permission administrator that is responsible for their metering points under consideration. Competent authority Final customer [not relevant]
4.2 Authenticate final customer Final customers identify themselves to the permission administrator. Final customer Permission administrator [not relevant]
4.3 Check credentials Permission administrator transfers authentication information to identity service provider. Permission administrator Identity service provider [not relevant]
4.4 Inform final customer of credential check results Permission administrator communicates validation result and provide a meaningful indication in case of an invalid request. Permission administrator Final customer [not relevant]
4.5 List of permissions Permission administrator makes available to the final customer a list of active and expired permissions he has previously given Permission administrator Final customer I – Established permission information
4.6 Trigger permission revocation (explicit) The final customer indicates to the permission administrator which permission shall be revoked. Final customer Permission administrator I – Established permission information
4.7 Receive change of metering point entitlement (implicit) External reasons (for example, a move-out) lead to an invalidation of the entitlement of a final customer to a metering point. The metering point administrator informs the metered data administrator about these events. Metering point administrator Metered data administrator [not relevant]
4.8 Notify permission administrator Metered data administrator informs the permission administrator about the necessity to revoke all permissions for the metering point. Metered data administrator Permission administrator I – Established permission information
4.9 Notify metered data administrator The permission administrator informs the metered data administrator about the revocation. Permission administrator Metered data administrator I – Established permission information
4.10 End data sharing The metered data administrator must not transfer data under the scope of the revoked permission anymore. Metered data administrator [not relevant] [not relevant]
4.11 Notify eligible party The permission administrator must inform the affected eligible party immediately and without unnecessary delay. Permission administrator Eligible party I – Established permission information
4.12 Execute permission end tasks The eligible party performs all tasks required to fulfil its related responsibilities immediately and without undue delay and in accordance with Regulation (EU) 2016/679. Eligible party [not relevant] [not relevant]
4.13 Notify final customer The permission administrator makes available the information that the permission has been revoked to the final customer. Permission administrator Customer I – Established permission information

Image omitted; see official source

Diagram 4 - Procedure ‘Revocation of an active permission by the final customer’

Table III.5
Procedure 5
Procedure name Procedure name Activate near real-time data flow from smart meter or smart metering system (where applicable) Activate near real-time data flow from smart meter or smart metering system (where applicable) Activate near real-time data flow from smart meter or smart metering system (where applicable) Activate near real-time data flow from smart meter or smart metering system (where applicable)
Step No Step Step description Information producer Information receiver Information exchanged (IDs)
5.1 Identify meter operator Final customer finds out contact information for responsible party to activate data flow. Competent authority Final customer [not relevant]
5.2 Final customer requests near real-time data flow to be turned on Final customer sends meter operator the necessary information to make data flow accessible. Final customer Meter operator M – Data flow activation request
5.3 Provide meter credentials Meter operator sends the final customer all information necessary to consume and/or decrypt data flowing out of the meter. Meter operator Final customer N – Confirmation of data flow activation

Image omitted; see official source

Diagram 5 - Procedure ‘Activate near real-time data flow from smart meter or smart metering system’

Table III.6
Procedure 6
Procedure name Procedure name Read near real-time data from smart meter or smart metering system Read near real-time data from smart meter or smart metering system Read near real-time data from smart meter or smart metering system Read near real-time data from smart meter or smart metering system
Step No Step Step description Information producer Information receiver Information exchanged (IDs)
6.1 Connect near real-time data consumption system to meter If applicable, final customer connects near real-time data consumption system with near real-time interface and provides credentials or certificates as defined by national procedures. Final customer [not relevant] [not relevant]
6.2 Transfer data through near real-time interface Push or pull data through meter’s (local or remote) near real-time data interface. Smart meter or smart metering system Near real-time data consumption system O – Raw meter data
6.3 Interpret data Near real-time data consumption system processes the data that was received in the previous step. If required, it de-crypts the data using the cipher provided by the meter operator in step 5.3. It is recommended that at the end of step 6.3, attributes of information object P must be available in a form that can easily be used in the follow-up processes. When mapping this step, it is not enough to refer to a standard - descriptions of all necessary steps must be provided exhaustively. Note: Further use, processing or transfer of process-able meter data is not part of this reference model. Near real-time data consumption system Near real-time data consumption system P – Processable meter data

Image omitted; see official source

Diagram 6 – Procedure ‘Read near real-time data from smart meter or smart metering system’

Table IV
Information objects exchanged
Information exchanged, ID Name of information Description of information exchanged Description of information exchanged
A Metering point identification Metering point identifier Unique identifier for the metering point within the metered data administrator’s meter identification space.
B Metered data specification Reading start timestamp Start of the time interval covered by the data package.
B Metered data specification Reading end timestamp End of the time interval covered by the data package.
B Metered data specification Direction Flow direction metered by the metering point. This can be either solely production, consumption, or combined.
B Metered data specification Energy product Energy product measured by the metering point (for example, active energy, re-active energy).
C Metered data request Metering point identifier Unique identifier for the metering point within the metered data administrator’s meter identification space.
C Metered data request Metered data specification Information object B– Metered data specification
D Request validation information Validation result Information about the outcome of the validation step.
E Validated historical data Meta information Meta information
E Validated historical data Metering point identifier Unique identifier for the metering point within the metered data administrator’s meter identification space.
E Validated historical data Creation timestamp Timestamp when the data package has been generated.
E Validated historical data Energy product Energy product measured by the metering point (for example, active energy, re-active energy).
E Validated historical data Reading start timestamp Start timestamp of the time series.
E Validated historical data Reading end timestamp End timestamp of the time series.
E Validated historical data Unit of measure The measurement unit in which the quantities in field ‘Quantity’ have been stated.
E Validated historical data Time series information (once per interval in reading) Time series information (once per interval in reading)
E Validated historical data Start timestamp Start timestamp of interval.
E Validated historical data End timestamp End timestamp of interval.
E Validated historical data Direction Flow direction metered by the metering point. This can either be production, consumption or combined.
E Validated historical data Quality of reading Indication of the quality of the interval reading (for instance, based on the fact that the value is metered or estimated).
E Validated historical data Quantity Volume consumed or generated.
F Validated historical data with final customer information Validated historical data Information object E – Validated historical data
F Validated historical data with final customer information Final customer Information that allows the eligible party to potentially verify that it gets the data for the correct final customer.
G Preset permission information Eligible party Eligible party for which the permission has been given.
G Preset permission information Metering point identifier Optional. Unique identifier for the metering point within the metered data administrator’s meter identification space.
G Preset permission information Metered data specification Information object B– Metered data specification
G Preset permission information Purpose The specified, explicit and legitimate purpose for which the eligible party intends to process the data. For non-personal data this is optional.
G Preset permission information Transmission schedule For future data covered by the permission, but not available at the time the permission is established, the periodicity - when and how often - data packages are to be made available where applicable.
G Preset permission information Permission limit timestamp The timestamp by which the eligible party has to delete the received data, even if the processing purpose is not fulfilled by then.
H Basic permission information Final customer Final customer that has given the permission.
H Basic permission information Eligible party Eligible party for which the permission has been given.
H Basic permission information Metered data request Information object C– Metered data request
H Basic permission information Purpose The specified explicit and legitimate purpose for which data is processed. For non-personal data this is optional.
H Basic permission information Transmission schedule For future data covered by the permission, but not available at the time the permission is established, the periodicity - when and how often - data packages are to be made available where applicable (for example, in data exchange scenarios where data is pushed rather than requested).
H Basic permission information Permission maximum lifetime The timestamp after which the eligible party has to consider the permission as expired or revoked, even if the processing purpose is not fulfilled by then.
I Established permission information Permission identifier A unique identifier of the permission.
I Established permission information Creation timestamp Creation timestamp the permission administrator has attached to the permission.
I Established permission information Basic permission information Information object H– Permission information
J Notification of termination of service Permission identifier A unique identifier of the permission referring to information object I – Established permission information.
J Notification of termination of service Termination timestamp Timestamp indicating the point in time when the service is considered terminated by the eligible party.
K Details of information on listed permission Details of the permission Attributes of the permission as described in I – Established permission information.
K Details of information on listed permission Reason for the end of permission If permission is not active anymore, the reason for why the permission administrator considers the permission has ended. For instance, this can indicate fulfilment of purpose, reach of permission end timestamp, revocation of final customer or termination by the eligible party.
K Details of information on listed permission Permission end timestamp If permission is not active anymore, the timestamp since when the permission administrator considers the permission as ended
L Revocation notification by permission administrator Permission identifier A unique identifier of the permission referring to information object I – Established permission information.
L Revocation notification by permission administrator Permission end timestamp Timestamp for when the revocation should be considered active.
M Data flow activation request Meter identifier Identifier for the metering device or the metering point required by the meter operator to identify the correct meter.
M Data flow activation request Other required information Listing of all other attributes needed by the meter operator to enable the data flow.
N Confirmation of data flow activation Physical connectivity Information on the physical interface of the meter and how to connect external devices.
N Confirmation of data flow activation Cipher Mandatory, if a cipher is needed to de-crypt the flow of information
N Confirmation of data flow activation Credentials Mandatory, if credentials are needed to access the smart meter interface.
N Confirmation of data flow activation Other required information Listing of all other attributes needed by the meter operator to enable the data flow and interpret it semantically.
O Raw meter data Data package List of attributes in the received raw data. If a reference to a standard is provided here in the mappings of national practices, this standard must be publicly available in an easily accessible form or free of charge. Otherwise, all elements of the respective data package must be listed and mapped.
P Process-able meter data (attributes described are a minimum – other data items may also be provided and documented if available in national settings) Meter data timestamp Time of data capture as regarded by the smart meter or smart metering system.
P Process-able meter data (attributes described are a minimum – other data items may also be provided and documented if available in national settings) Active import power value Instantaneous forward active power P+ (in W)
P Process-able meter data (attributes described are a minimum – other data items may also be provided and documented if available in national settings) Active import power unit of measure -
P Process-able meter data (attributes described are a minimum – other data items may also be provided and documented if available in national settings) Active export power value Instantaneous reverse active power P- (in W)
P Process-able meter data (attributes described are a minimum – other data items may also be provided and documented if available in national settings) Active export power unit of measure -
P Process-able meter data (attributes described are a minimum – other data items may also be provided and documented if available in national settings) Import active energy A+ Forward active energy A+ (in Wh)
P Process-able meter data (attributes described are a minimum – other data items may also be provided and documented if available in national settings) Import active energy A+ unit of measure -
P Process-able meter data (attributes described are a minimum – other data items may also be provided and documented if available in national settings) Export active energy Reverse active energy A- (in Wh)
P Process-able meter data (attributes described are a minimum – other data items may also be provided and documented if available in national settings) Export active energy unit of measure -
11

CEN/CLC/ETSI/TR 50572:2011 - ‘Functional reference architecture for communications in smart metering systems’, by CEN/CLC/ETSI Coordination Group on Smart Meters.

12

Business Process Model and Notation 2.0: https://www.omg.org/spec/BPMN/2.0.2/PDF.

Reading this document does not replace reading the official text published in the Official Journal of the European Union. We assume no responsibility for any inaccuracies arising from the conversion of the original to this format.

This text is published under EUR-Lex's own terms of reuse, not a Legalize or public-domain licence. EUR-Lex
Creative Commons Attribution 4.0 International (CC BY 4.0)
© European Union, https://eur-lex.europa.eu — Source: EUR-Lex (Publications Office of the European Union). Reused under the Creative Commons Attribution 4.0 International (CC BY 4.0) licence. Only EU legislation published in the printed Official Journal of the European Union is deemed authentic; consolidated texts are reproduced here for documentation purposes and have been reformatted to Markdown.