Commission Implementing Regulation (EU) 2025/1533 of 23 July 2025 laying down rules for the application of Directive 2014/90/EU of the European Parliament and of the Council as regards design, construction and performance requirements and testing standards for marine equipment and repealing Commission Implementing Regulation (EU) 2024/1975
This is the act as published. Later amendments are not folded into the text below: each one is a separate act in this repository and an entry in this law's history.
| 1 | 2 | 3 | 4 | 5 | 6 |
|---|---|---|---|---|---|
| MED/3.51a Fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces: — control and indicating equipment Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 2 | Type approval requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. X/3, — IMO Res. MSC.98(73)-(FSS Code) 9. | Electrical installations in ships: — EN 54-2:1997 incl. AC:1999 and A1:2006. And as applicable, electrical, and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 19.6.2018 | 15.8.2025 (iii) |
| MED/3.51a Fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces: — control and indicating equipment Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 2 | Carriage and performance requirements — SOLAS 74 Reg. II-2/7, — IMO Res. MSC.36(63)-(1994 HSC Code) 7, — IMO Res. MSC.97(73)-(2000 HSC Code) 7, — IMO Res. MSC.98(73)-(FSS Code) 9, — IMO Res. MSC.391(95)-(IGF Code) 11, — IMO MSC.1/Circ.1242, — IMO MSC.1/Circ.1487, — IMO MSC.1/Circ.1528. | Electrical installations in ships: — EN 54-2:1997 incl. AC:1999 and A1:2006. And as applicable, electrical, and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 19.6.2018 | 15.8.2025 (iii) |
| MED/3.51a Fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces: — control and indicating equipment Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 2 of 2 | Type approval requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. X/3, — IMO Res. MSC.98(73)-(FSS Code) 9. | Electrical installations in ships: — EN 54-2:1997 incl. AC:1999 and A1:2006. — EN 60945:2002 incl. IEC 60945 Corr. 1:2008, — EN IEC 62923-1:2018, — EN IEC 62923-2:2018. Or, — EN 54-2:1997 incl. AC:1999 and A1:2006. — IEC 60945:2002 incl. IEC 60945 Corr. 1:2008, — IEC 62923-1:2018, — IEC 62923-2:2018. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 15.8.2022 | |
| MED/3.51a Fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces: — control and indicating equipment Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 2 of 2 | Carriage and performance requirements — SOLAS 74 Reg. II-2/7, — IMO Res. MSC.36(63)-(1994 HSC Code) 7, — IMO Res. MSC.97(73)-(2000 HSC Code) 7, — IMO Res. MSC.98(73)-(FSS Code) 9, — IMO Res. MSC.302(87), — IMO Res. MSC.391(95)-(IGF Code) 11, — IMO MSC.1/Circ.1242, — IMO MSC.1/Circ.1487, — IMO MSC.1/Circ.1528. | Electrical installations in ships: — EN 54-2:1997 incl. AC:1999 and A1:2006. — EN 60945:2002 incl. IEC 60945 Corr. 1:2008, — EN IEC 62923-1:2018, — EN IEC 62923-2:2018. Or, — EN 54-2:1997 incl. AC:1999 and A1:2006. — IEC 60945:2002 incl. IEC 60945 Corr. 1:2008, — IEC 62923-1:2018, — IEC 62923-2:2018. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 15.8.2022 | |
| MED/3.51b Fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces: — power supply equipment Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 1 | Type approval requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. X/3, — IMO Res. MSC.98(73)-(FSS Code) 9. | — EN 54-4:1997 incl. AC:1999, A1:2002 and A2:2006. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 19.6.2018 | |
| MED/3.51b Fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces: — power supply equipment Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 1 | Carriage and performance requirements — SOLAS 74 Reg. II-2/7, — IMO Res. MSC.36(63)-(1994 HSC Code) 7, — IMO Res. MSC.97(73)-(2000 HSC Code) 7, — IMO Res. MSC.98(73)-(FSS Code) 9, — IMO Res. MSC.391(95)-(IGF Code) 11, — IMO MSC.1/Circ.1242, — IMO MSC.1/Circ.1554. | — EN 54-4:1997 incl. AC:1999, A1:2002 and A2:2006. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 19.6.2018 | |
| MED/3.51c Fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces: — heat detectors - point detectors Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 1 | Type approval requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. X/3, — IMO Res. MSC.98(73)-(FSS Code) 9. | — EN 54-5:2017 incl. A1:2018. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 12.8.2020 | |
| MED/3.51c Fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces: — heat detectors - point detectors Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 1 | Carriage and performance requirements — SOLAS 74 Reg. II-2/7, — IMO Res. MSC.36(63)-(1994 HSC Code) 7, — IMO Res. MSC.97(73)-(2000 HSC Code) 7, — IMO Res. MSC.98(73)-(FSS Code) 9, — IMO Res. MSC.391(95)-(IGF Code) 11, — IMO MSC.1/Circ.1242. | — EN 54-5:2017 incl. A1:2018. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 12.8.2020 | |
| MED/3.51d Fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces: — smoke detectors: point detectors using scattered light, transmitted light or ionization Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 1 | Type approval requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. X/3, — IMO Res. MSC.98(73)-(FSS Code) 9. | — EN 54-7:2018. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 13.9.2019 | |
| MED/3.51d Fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces: — smoke detectors: point detectors using scattered light, transmitted light or ionization Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 1 | Carriage and performance requirements — SOLAS 74 Reg. II-2/7, — IMO Res. MSC.36(63)-(1994 HSC Code) 7, — IMO Res. MSC.97(73)-(2000 HSC Code) 7, — IMO Res. MSC.98(73)-(FSS Code) 9, — IMO Res. MSC.391(95)-(IGF Code) 11, — IMO MSC.1/Circ.1242. | — EN 54-7:2018. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 13.9.2019 | |
| MED/3.51e Fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces: — flame detectors: point detectors Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 1 | Type approval requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. X/3, — IMO Res. MSC.98(73)-(FSS Code) 9. | — EN 54-10:2002 incl. A1:2005, And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 19.6.2018 | |
| MED/3.51e Fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces: — flame detectors: point detectors Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 1 | Carriage and performance requirements — SOLAS 74 Reg. II-2/7, — IMO Res. MSC.36(63)-(1994 HSC Code) 7, — IMO Res. MSC.97(73)-(2000 HSC Code) 7, — IMO Res. MSC.98(73)-(FSS Code) 9, — IMO Res. MSC.391(95)-(IGF Code) 11, — IMO MSC.1/Circ.1242. | — EN 54-10:2002 incl. A1:2005, And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 19.6.2018 | |
| MED/3.51f Fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces: — manual call points Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 1 | Type approval requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. X/3, — IMO Res. MSC.98(73)-(FSS Code) 9. | — EN 54-11:2001 incl. A1:2005. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 19.6.2018 | |
| MED/3.51f Fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces: — manual call points Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 1 | Carriage and performance requirements — SOLAS 74 Reg. II-2/7, — IMO Res. MSC.36(63)-(1994 HSC Code) 7, — IMO Res. MSC.97(73)-(2000 HSC Code) 7, — IMO Res. MSC.98(73)-(FSS Code) 9, — IMO Res. MSC.391(95)-(IGF Code) 11, — IMO MSC.1/Circ.1242. | — EN 54-11:2001 incl. A1:2005. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 19.6.2018 | |
| MED/3.51g Fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces: — short circuit isolators Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 1 | Type approval requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. X/3, — IMO Res. MSC.98(73)-(FSS Code) 9. | — EN 54-17:2005 incl. AC:2007. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 19.6.2018 | |
| MED/3.51g Fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces: — short circuit isolators Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 1 | Carriage and performance requirements — SOLAS 74 Reg. II-2/7, — IMO Res. MSC.36(63)-(1994 HSC Code) 7, — IMO Res. MSC.97(73)-(2000 HSC Code) 7, — IMO Res. MSC.98(73)-(FSS Code) 9, — IMO Res. MSC.391(95)-(IGF Code) 11, — IMO MSC.1/Circ.1242. | — EN 54-17:2005 incl. AC:2007. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 19.6.2018 | |
| MED/3.51h Fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces: — input/output devices Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 1 | Type approval requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. X/3, — IMO Res. MSC.98(73)-(FSS Code) 9. | — EN 54-18:2005 incl. AC:2007. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 19.6.2018 | |
| MED/3.51h Fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces: — input/output devices Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 1 | Carriage and performance requirements — SOLAS 74 Reg. II-2/7, — IMO Res. MSC.36(63)-(1994 HSC Code) 7, — IMO Res. MSC.97(73)-(2000 HSC Code) 7, — IMO Res. MSC.98(73)-(FSS Code) 9, — IMO Res. MSC.391(95)-(IGF Code) 11, — IMO MSC.1/Circ.1242. | — EN 54-18:2005 incl. AC:2007. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 19.6.2018 | |
| MED/3.51i Fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces: — cables Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 2 | Type approval requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. X/3, — IMO Res. MSC.98(73)-(FSS Code) 9. | — EN 60332-1-2:2004 incl. A1:2015 and A11:2016, — IEC 60092-376:2017. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. — IEC 60332-1-2:2004 incl. A1:2015. And/or: Fire Resistant Cables: — IEC 60092-376:2017, — IEC 60331-1:2018 or IEC 60331-2:2018. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015, — IEC 60332-1-2:2004 incl. A1:2015. | B+D B+E B+F | 13.9.2019 | 15.8.2025 (iii) |
| MED/3.51i Fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces: — cables Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 2 | Carriage and performance requirements — SOLAS 74 Reg. II-2/7, — IMO Res. MSC.36(63)-(1994 HSC Code) 7, — IMO Res. MSC.97(73)-(2000 HSC Code) 7, — IMO Res. MSC.98(73)-(FSS Code) 9, — IMO Res. MSC.391(95)-(IGF Code) 11, — IMO MSC.1/Circ.1242. | — EN 60332-1-2:2004 incl. A1:2015 and A11:2016, — IEC 60092-376:2017. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. — IEC 60332-1-2:2004 incl. A1:2015. And/or: Fire Resistant Cables: — IEC 60092-376:2017, — IEC 60331-1:2018 or IEC 60331-2:2018. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015, — IEC 60332-1-2:2004 incl. A1:2015. | B+D B+E B+F | 13.9.2019 | 15.8.2025 (iii) |
| MED/3.51i Fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces: — cables Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 2 of 2 | Type approval requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. X/3, — IMO Res. MSC.98(73)-(FSS Code) 9. | — EN 60332-1-2:2004 incl. A1:2015, A11:2016 and A12:2020, — IEC 60092-376:2017. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. — IEC 60332-1-2:2004 incl. A1:2015. And/or: Fire Resistant Cables: — IEC 60092-376:2017, — IEC 60331-1:2018 or IEC 60331-2:2018. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015, — IEC 60332-1-2:2004 incl. A1:2015. | B+D B+E B+F | 15.8.2022 | |
| MED/3.51i Fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces: — cables Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 2 of 2 | Carriage and performance requirements — SOLAS 74 Reg. II-2/7, — IMO Res. MSC.36(63)-(1994 HSC Code) 7, — IMO Res. MSC.97(73)-(2000 HSC Code) 7, — IMO Res. MSC.98(73)-(FSS Code) 9, — IMO Res. MSC.391(95)-(IGF Code) 11, — IMO MSC.1/Circ.1242. | — EN 60332-1-2:2004 incl. A1:2015, A11:2016 and A12:2020, — IEC 60092-376:2017. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. — IEC 60332-1-2:2004 incl. A1:2015. And/or: Fire Resistant Cables: — IEC 60092-376:2017, — IEC 60331-1:2018 or IEC 60331-2:2018. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015, — IEC 60332-1-2:2004 incl. A1:2015. | B+D B+E B+F | 15.8.2022 | |
| MED/3.52 Non-portable and transportable fire extinguishers Row 1 of 1 | Type approval requirements — SOLAS 74 Reg. II-2/10, — SOLAS 74 Reg. X/3. | — EN 1866-1:2007, — EN 1866-2:2014. Or: — EN 1866-1:2007, — EN 1866-3:2013. Or: — ISO 11601:2017. | B+D B+E B+F | 13.9.2019 | |
| MED/3.52 Non-portable and transportable fire extinguishers Row 1 of 1 | Carriage and performance requirements — SOLAS 74 Reg. II-2/4, — SOLAS 74 Reg. II-2/10, — IMO Res. MSC.36(63)-(1994 HSC Code) 7, — IMO Res. MSC.97(73)-(2000 HSC Code) 7. | — EN 1866-1:2007, — EN 1866-2:2014. Or: — EN 1866-1:2007, — EN 1866-3:2013. Or: — ISO 11601:2017. | B+D B+E B+F | 13.9.2019 | |
| MED/3.53 Fire alarm devices – sounders Row 1 of 2 | Type approval requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. X/3, — IMO Res. MSC.98(73)-(FSS Code) 9. | — EN 54-3:2014, — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 16.3.2017 | 12.8.2023 (iii) |
| MED/3.53 Fire alarm devices – sounders Row 1 of 2 | Carriage and performance requirements — SOLAS 74 Reg. II-2/7, — IMO Res. MSC.36(63)-(1994 HSC Code) 7, — IMO Res. MSC.97(73)-(2000 HSC Code) 7, — IMO Res. MSC.98(73)-(FSS Code) 9. — IMO MSC.1/Circ.1242, — IMO MSC.1/Circ.1487. | — EN 54-3:2014, — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 16.3.2017 | 12.8.2023 (iii) |
| MED/3.53 Fire alarm devices – sounders Row 2 of 2 | Type approval requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. X/3, — IMO Res. MSC.98(73)-(FSS Code) 9. | — EN 54-3:2014 incl. A1:2019, — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 12.8.2020 | |
| MED/3.53 Fire alarm devices – sounders Row 2 of 2 | Carriage and performance requirements — SOLAS 74 Reg. II-2/7, — IMO Res. MSC.36(63)-(1994 HSC Code) 7, — IMO Res. MSC.97(73)-(2000 HSC Code) 7, — IMO Res. MSC.98(73)-(FSS Code) 9. — IMO MSC.1/Circ.1242, — IMO MSC.1/Circ.1487. | — EN 54-3:2014 incl. A1:2019, — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 12.8.2020 | |
| MED/3.54a Fixed oxygen analysis and/or gas detection equipment: — category 4: (safe area) Row 1 of 3 | Type approval requirements — SOLAS 74 Reg. II-2/4, — SOLAS 74 Reg. VI/3. | — EN 50104:2010, — IEC 60092-504:2016, — IEC 60533:2015. For combined O2/HC systems, additionally: — IMO MSC.1/Circ.1370. | B+D B+E B+F | 12.8.2020 | 25.8.2024 (iii) |
| MED/3.54a Fixed oxygen analysis and/or gas detection equipment: — category 4: (safe area) Row 1 of 3 | Carriage and performance requirements — SOLAS 74 Reg. II-2/4, — SOLAS 74 Reg. VI/3, — IMO Res. MSC.98(73)-(FSS Code) 15, — for combined O2/HC systems additionally: — IMO MSC.1/Circ.1370. | — EN 50104:2010, — IEC 60092-504:2016, — IEC 60533:2015. For combined O2/HC systems, additionally: — IMO MSC.1/Circ.1370. | B+D B+E B+F | 12.8.2020 | 25.8.2024 (iii) |
| MED/3.54a Fixed oxygen analysis and/or gas detection equipment: — category 4: (safe area) Row 2 of 3 | Type approval requirements — SOLAS 74 Reg. II-2/4, — SOLAS 74 Reg. VI/3. | — EN 50104:2019, — IEC 60092-504:2016, — IEC 60533:2015. For combined O2/HC systems, additionally: — IMO MSC.1/Circ.1370. | B+D B+E B+F | 25.8.2021 | 4.9.2027 (iii) |
| MED/3.54a Fixed oxygen analysis and/or gas detection equipment: — category 4: (safe area) Row 2 of 3 | Carriage and performance requirements — SOLAS 74 Reg. II-2/4, — SOLAS 74 Reg. VI/3, — IMO Res. MSC.98(73)-(FSS Code) 15, — for combined O2/HC systems additionally: — IMO MSC.1/Circ.1370. | — EN 50104:2019, — IEC 60092-504:2016, — IEC 60533:2015. For combined O2/HC systems, additionally: — IMO MSC.1/Circ.1370. | B+D B+E B+F | 25.8.2021 | 4.9.2027 (iii) |
| MED/3.54a Fixed oxygen analysis and/or gas detection equipment: — category 4: (safe area) Row 3 of 3 | Type approval requirements — SOLAS 74 Reg. II-2/4, — SOLAS 74 Reg. VI/3. | — EN 50104:2019 incl. EN 50104:2019/A1:2023, — IEC 60092-504:2016, — IEC 60533:2015. For combined O2/HC systems, additionally: — IMO MSC.1/Circ.1370. | B+D B+E B+F | 4.9.2024 | |
| MED/3.54a Fixed oxygen analysis and/or gas detection equipment: — category 4: (safe area) Row 3 of 3 | Carriage and performance requirements — SOLAS 74 Reg. II-2/4, — SOLAS 74 Reg. VI/3, — IMO Res. MSC.98(73)-(FSS Code) 15, — for combined O2/HC systems additionally: — IMO MSC.1/Circ.1370. | — EN 50104:2019 incl. EN 50104:2019/A1:2023, — IEC 60092-504:2016, — IEC 60533:2015. For combined O2/HC systems, additionally: — IMO MSC.1/Circ.1370. | B+D B+E B+F | 4.9.2024 | |
| MED/3.54b Fixed oxygen analysis and/or gas detection equipment: — category 3: (explosive gas atmospheres) Row 1 of 5 | Type approval requirements — SOLAS 74 Reg. II-2/4, — SOLAS 74 Reg. VI/3. | — EN 50104:2010, — EN 60079-0:2012 incl. A11:2013, — EN 60079-29-1:2016, — IEC 60092-504:2016, — IEC 60533:2015. For combined O2/HC systems, additionally: — IMO MSC.1/Circ.1370. | B+D B+E B+F | 19.6.2018 | 12.8.2023 (iii) |
| MED/3.54b Fixed oxygen analysis and/or gas detection equipment: — category 3: (explosive gas atmospheres) Row 1 of 5 | Carriage and performance requirements — SOLAS 74 Reg. II-2/4, — SOLAS 74 Reg. VI/3, — IMO Res. MSC.98(73)-(FSS Code) 15, — for combined O2/HC systems additionally: — IMO MSC.1/Circ.1370. | — EN 50104:2010, — EN 60079-0:2012 incl. A11:2013, — EN 60079-29-1:2016, — IEC 60092-504:2016, — IEC 60533:2015. For combined O2/HC systems, additionally: — IMO MSC.1/Circ.1370. | B+D B+E B+F | 19.6.2018 | 12.8.2023 (iii) |
| MED/3.54b Fixed oxygen analysis and/or gas detection equipment: — category 3: (explosive gas atmospheres) Row 2 of 5 | Type approval requirements — SOLAS 74 Reg. II-2/4, — SOLAS 74 Reg. VI/3. | — EN 50104:2010, — EN IEC 60079-0:2018, — EN 60079-29-1:2016, — IEC 60092-504:2016, — IEC 60533:2015. For combined O2/HC systems, additionally: — IMO MSC.1/Circ.1370. | B+D B+E B+F | 12.8.2020 | 25.8.2024 (iii) |
| MED/3.54b Fixed oxygen analysis and/or gas detection equipment: — category 3: (explosive gas atmospheres) Row 2 of 5 | Carriage and performance requirements — SOLAS 74 Reg. II-2/4, — SOLAS 74 Reg. VI/3, — IMO Res. MSC.98(73)-(FSS Code) 15, — for combined O2/HC systems additionally: — IMO MSC.1/Circ.1370. | — EN 50104:2010, — EN IEC 60079-0:2018, — EN 60079-29-1:2016, — IEC 60092-504:2016, — IEC 60533:2015. For combined O2/HC systems, additionally: — IMO MSC.1/Circ.1370. | B+D B+E B+F | 12.8.2020 | 25.8.2024 (iii) |
| MED/3.54b Fixed oxygen analysis and/or gas detection equipment: — category 3: (explosive gas atmospheres) Row 3 of 5 | Type approval requirements — SOLAS 74 Reg. II-2/4, — SOLAS 74 Reg. VI/3. | — EN 50104:2019, — EN IEC 60079-0:2018 incl. AC:2020, — EN 60079-29-1:2016, — IEC 60092-504:2016, — IEC 60533:2015. For combined O2/HC systems, additionally: — IMO MSC.1/Circ.1370. | B+D B+E B+F | 25.8.2021 | 4.9.2027 (iii) |
| MED/3.54b Fixed oxygen analysis and/or gas detection equipment: — category 3: (explosive gas atmospheres) Row 3 of 5 | Carriage and performance requirements — SOLAS 74 Reg. II-2/4, — SOLAS 74 Reg. VI/3, — IMO Res. MSC.98(73)-(FSS Code) 15, — for combined O2/HC systems additionally: — IMO MSC.1/Circ.1370. | — EN 50104:2019, — EN IEC 60079-0:2018 incl. AC:2020, — EN 60079-29-1:2016, — IEC 60092-504:2016, — IEC 60533:2015. For combined O2/HC systems, additionally: — IMO MSC.1/Circ.1370. | B+D B+E B+F | 25.8.2021 | 4.9.2027 (iii) |
| MED/3.54b Fixed oxygen analysis and/or gas detection equipment: — category 3: (explosive gas atmospheres) Row 4 of 5 | Type approval requirements — SOLAS 74 Reg. II-2/4, — SOLAS 74 Reg. VI/3. | — EN 50104:2019 incl. EN 50104:2019/A1:2023, — EN IEC 60079-0:2018 incl. AC:2020, — EN 60079-29-1:2016 incl. EN 60079-29-1:2016/A1:2022 and EN 60079-29-1:2016/A11:2022, — IEC 60092-504:2016, — IEC 60533:2015. For combined O2/HC systems, additionally: — IMO MSC.1/Circ.1370. | B+D B+E B+F | 4.9.2024 | 23.9.2028 (iii) |
| MED/3.54b Fixed oxygen analysis and/or gas detection equipment: — category 3: (explosive gas atmospheres) Row 4 of 5 | Carriage and performance requirements — SOLAS 74 Reg. II-2/4, — SOLAS 74 Reg. VI/3, — IMO Res. MSC.98(73)-(FSS Code) 15, — for combined O2/HC systems additionally: — IMO MSC.1/Circ.1370. | — EN 50104:2019 incl. EN 50104:2019/A1:2023, — EN IEC 60079-0:2018 incl. AC:2020, — EN 60079-29-1:2016 incl. EN 60079-29-1:2016/A1:2022 and EN 60079-29-1:2016/A11:2022, — IEC 60092-504:2016, — IEC 60533:2015. For combined O2/HC systems, additionally: — IMO MSC.1/Circ.1370. | B+D B+E B+F | 4.9.2024 | 23.9.2028 (iii) |
| MED/3.54b Fixed oxygen analysis and/or gas detection equipment: — category 3: (explosive gas atmospheres) Row 5 of 5 (NEW ROW) | Type approval requirements — SOLAS 74 Reg. II-2/4, — SOLAS 74 Reg. VI/3. | — EN 50104:2019 incl. EN 50104:2019/A1:2023, — EN IEC 60079-0:2018, incl. AC:2020-02, and A11:2024, — EN 60079-29-1:2016 incl. EN 60079-29-1:2016/A1:2022 and EN 60079-29-1:2016/A11:2022, — IEC 60092-504:2016, — IEC 60533:2015. For combined O2/HC systems, additionally: — IMO MSC.1/Circ.1370. | B+D B+E B+F | 23.9.2025 | |
| MED/3.54b Fixed oxygen analysis and/or gas detection equipment: — category 3: (explosive gas atmospheres) Row 5 of 5 (NEW ROW) | Carriage and performance requirements — SOLAS 74 Reg. II-2/4, — SOLAS 74 Reg. VI/3, — IMO Res. MSC.98(73)-(FSS Code) 15, — for combined O2/HC systems additionally: — IMO MSC.1/Circ.1370. | — EN 50104:2019 incl. EN 50104:2019/A1:2023, — EN IEC 60079-0:2018, incl. AC:2020-02, and A11:2024, — EN 60079-29-1:2016 incl. EN 60079-29-1:2016/A1:2022 and EN 60079-29-1:2016/A11:2022, — IEC 60092-504:2016, — IEC 60533:2015. For combined O2/HC systems, additionally: — IMO MSC.1/Circ.1370. | B+D B+E B+F | 23.9.2025 | |
| MED/3.55a Dual purpose type nozzles (spray/jet type): — Hand-held branch pipes for fire service use - Combination branch pipes PN 16 Row 1 of 2 | Type approval requirements — SOLAS 74 Reg. II-2/10, — SOLAS 74 Reg. X/3. | — EN 15182-1:2007 incl. A1:2009, — EN 15182-2:2007 incl. A1:2009. | B+D B+E B+F | 12.8.2023 (iii) | |
| MED/3.55a Dual purpose type nozzles (spray/jet type): — Hand-held branch pipes for fire service use - Combination branch pipes PN 16 Row 1 of 2 | Carriage and performance requirements — SOLAS 74 Reg. II-2/10, — IMO Res. MSC.36(63)-(1994 HSC Code) 7, — IMO Res .MSC.97(73)-(2000 HSC Code) 7. | — EN 15182-1:2007 incl. A1:2009, — EN 15182-2:2007 incl. A1:2009. | B+D B+E B+F | 12.8.2023 (iii) | |
| MED/3.55a Dual purpose type nozzles (spray/jet type): — Hand-held branch pipes for fire service use - Combination branch pipes PN 16 Row 2 of 2 | Type approval requirements — SOLAS 74 Reg. II-2/10, — SOLAS 74 Reg. X/3. | — EN 15182-1:2019, — EN 15182-2:2019. | B+D B+E B+F | 12.8.2020 | |
| MED/3.55a Dual purpose type nozzles (spray/jet type): — Hand-held branch pipes for fire service use - Combination branch pipes PN 16 Row 2 of 2 | Carriage and performance requirements — SOLAS 74 Reg. II-2/10, — IMO Res. MSC.36(63)-(1994 HSC Code) 7, — IMO Res. MSC.97(73)-(2000 HSC Code) 7. | — EN 15182-1:2019, — EN 15182-2:2019. | B+D B+E B+F | 12.8.2020 | |
| MED/3.55b Dual purpose type nozzles (spray/jet type): — Hand-held branch pipes for fire service use - Smooth bore jet and/or one fixed spray jet angle branch pipes PN 16 Row 1 of 3 | Type approval requirements — SOLAS 74 Reg. II-2/10, — SOLAS 74 Reg. X/3. | — EN 15182-1:2007 incl. A1:2009, — EN 15182-3:2007 incl. A1:2009. | B+D B+E B+F | 12.8.2023 (iii) | |
| MED/3.55b Dual purpose type nozzles (spray/jet type): — Hand-held branch pipes for fire service use - Smooth bore jet and/or one fixed spray jet angle branch pipes PN 16 Row 1 of 3 | Carriage and performance requirements — SOLAS 74 Reg. II-2/10, — IMO Res. MSC.36(63)-(1994 HSC Code) 7, — IMO Res .MSC.97(73)-(2000 HSC Code) 7. | — EN 15182-1:2007 incl. A1:2009, — EN 15182-3:2007 incl. A1:2009. | B+D B+E B+F | 12.8.2023 (iii) | |
| MED/3.55b Dual purpose type nozzles (spray/jet type): — Hand-held branch pipes for fire service use - Smooth bore jet and/or one fixed spray jet angle branch pipes PN 16 Row 2 of 3 | Type approval requirements — SOLAS 74 Reg. II-2/10, — SOLAS 74 Reg. X/3. | — EN 15182-1:2019, — EN 15182-3:2019. | B+D B+E B+F | 12.8.2020 | 4.6.2025 (iii) |
| MED/3.55b Dual purpose type nozzles (spray/jet type): — Hand-held branch pipes for fire service use - Smooth bore jet and/or one fixed spray jet angle branch pipes PN 16 Row 2 of 3 | Carriage and performance requirements — SOLAS 74 Reg. II-2/10, — IMO Res. MSC.36(63)-(1994 HSC Code) 7, — IMO Res. MSC.97(73)-(2000 HSC Code) 7. | — EN 15182-1:2019, — EN 15182-3:2019. | B+D B+E B+F | 12.8.2020 | 4.6.2025 (iii) |
| MED/3.55b Dual purpose type nozzles (spray/jet type): — Hand-held branch pipes for fire service use - Smooth bore jet and/or one fixed spray jet angle branch pipes PN 16 Note: Minimum spray angle of 30°. Row 3 of 3 | Type approval requirements — SOLAS 74 Reg. II-2/10, — SOLAS 74 Reg. X/3. | — EN 15182-1:2019, — EN 15182-3:2019. | B+D B+E B+F | 4.9.2024 | |
| MED/3.55b Dual purpose type nozzles (spray/jet type): — Hand-held branch pipes for fire service use - Smooth bore jet and/or one fixed spray jet angle branch pipes PN 16 Note: Minimum spray angle of 30°. Row 3 of 3 | Carriage and performance requirements — SOLAS 74 Reg. II-2/10, — IMO Res. MSC.36(63)-(1994 HSC Code) 7, — IMO Res. MSC.97(73)-(2000 HSC Code) 7. | — EN 15182-1:2019, — EN 15182-3:2019. | B+D B+E B+F | 4.9.2024 | |
| MED/3.56 Fixed firefighting hose systems: — hose reels with semi-rigid hose Row 1 of 1 | Type approval requirements — SOLAS 74 Reg. II-2/10, — SOLAS 74 Reg. X/3. | — EN 671-1:2012. | B+D B+E B+F | ||
| MED/3.56 Fixed firefighting hose systems: — hose reels with semi-rigid hose Row 1 of 1 | Carriage and performance requirements — SOLAS 74 Reg. II-2/10, — IMO Res. MSC.36(63)-(1994 HSC Code) 7, — IMO Res. MSC.97(73)-(2000 HSC Code) 7. | — EN 671-1:2012. | B+D B+E B+F | ||
| MED/3.57 Medium Expansion Foam Fire Extinguishing Systems components - Fixed Deck Foam for Tankers Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 2 | Type approval requirements — SOLAS 74 Reg. II-2/10. | — IMO MSC/Circ.798. | B+D B+E B+F | 4.9.2027 (iii) | |
| MED/3.57 Medium Expansion Foam Fire Extinguishing Systems components - Fixed Deck Foam for Tankers Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 2 | Carriage and performance requirements — SOLAS 74 Reg. II-2/10.8.1, — IMO Res. MSC.98(73)-(FSS Code) 14, — IMO MSC/Circ.1239, — IMO MSC.1/Circ.1276. | — IMO MSC/Circ.798. | B+D B+E B+F | 4.9.2027 (iii) | |
| MED/3.57 Medium Expansion Foam Fire Extinguishing Systems components - Fixed Deck Foam for Tankers Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 2 of 2 | Type approval requirements — SOLAS 74 Reg. II-2/10. | — IMO MSC/Circ.798. | B+D B+E B+F | 4.9.2024 | |
| MED/3.57 Medium Expansion Foam Fire Extinguishing Systems components - Fixed Deck Foam for Tankers Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 2 of 2 | Carriage and performance requirements — SOLAS 74 Reg. II-2/10.8.1, — IMO Res. MSC.98(73)-(FSS Code) 14, — IMO MSC/Circ.1239, — IMO MSC.1/Circ.1276 Rev 1. | — IMO MSC/Circ.798. | B+D B+E B+F | 4.9.2024 | |
| MED/3.58 Fixed Low Expansion Foam Fire Extinguishing Systems Components for Machinery Spaces and Tanker Deck Protection Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 2 | Type approval requirements — SOLAS 74 Reg. II-2/10. | — IMO MSC.1/Circ.1312, — IMO MSC.1/Circ.1312/Corr.1. | B+D B+E B+F | 4.9.2027 (iii) | |
| MED/3.58 Fixed Low Expansion Foam Fire Extinguishing Systems Components for Machinery Spaces and Tanker Deck Protection Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 2 | Carriage and performance requirements — SOLAS 74 Reg. II-2/10, — IMO Res. MSC.98(73)-(FSS Code) 6, — IMO Res. MSC.98(73)-(FSS Code) 14, — IMO MSC/Circ.1239, — IMO MSC.1/Circ.1276. | — IMO MSC.1/Circ.1312, — IMO MSC.1/Circ.1312/Corr.1. | B+D B+E B+F | 4.9.2027 (iii) | |
| MED/3.58 Fixed Low Expansion Foam Fire Extinguishing Systems Components for Machinery Spaces and Tanker Deck Protection Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 2 of 2 | Type approval requirements — SOLAS 74 Reg. II-2/10. | — IMO MSC.1/Circ.1312, — IMO MSC.1/Circ.1312/Corr.1. | B+D B+E B+F | 4.9.2024 | |
| MED/3.58 Fixed Low Expansion Foam Fire Extinguishing Systems Components for Machinery Spaces and Tanker Deck Protection Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 2 of 2 | Carriage and performance requirements — SOLAS 74 Reg. II-2/10, — IMO Res. MSC.98(73)-(FSS Code) 6, — IMO Res. MSC.98(73)-(FSS Code) 14, — IMO MSC/Circ.1239, — IMO MSC.1/Circ.1276 Rev 1 | — IMO MSC.1/Circ.1312, — IMO MSC.1/Circ.1312/Corr.1. | B+D B+E B+F | 4.9.2024 | |
| MED/3.59 Expansion Foam for Fixed Fire Extinguishing Systems for Chemical Tankers Row 1 of 1 | Type approval requirements — SOLAS 74 Reg. II-2/1, — IMO Res. MSC.4(48)-(IBC Code) 11. | — IMO MSC.1/Circ.1312, — IMO MSC.1/Circ.1312/Corr.1. | B+D B+E B+F | ||
| MED/3.59 Expansion Foam for Fixed Fire Extinguishing Systems for Chemical Tankers Row 1 of 1 | Carriage and performance requirements — IMO Res. MSC.4(48)-(IBC Code) 11, — IMO MSC/Circ.553. | — IMO MSC.1/Circ.1312, — IMO MSC.1/Circ.1312/Corr.1. | B+D B+E B+F | ||
| MED/3.60 Nozzles for fixed pressure water-spraying fire-extinguishing systems for cabin balconies Row 1 of 1 | Type approval requirements — SOLAS 74 Reg. II-2/10, — IMO Res. MSC.98(73)-(FSS Code) 7. | — IMO MSC.1/Circ.1268. | B+D B+E B+F | ||
| MED/3.60 Nozzles for fixed pressure water-spraying fire-extinguishing systems for cabin balconies Row 1 of 1 | Carriage and performance requirements — SOLAS 74 Reg. II-2/10, — IMO Res. MSC.98(73)-(FSS Code) 7, — IMO MSC.1/Circ.1313. | — IMO MSC.1/Circ.1268. | B+D B+E B+F | ||
| MED/3.61a Inside air high expansion foam systems for the protection of machinery spaces, cargo pump rooms, vehicle and ro-ro spaces, special category spaces and cargo spaces Note: Inside/Outside air high expansion foam systems for the protection of machinery spaces, cargo pump rooms, vehicle and ro-ro spaces, special category spaces and cargo spaces shall be tested with the approved concentrate to the satisfaction of the Administration. Row 1 of 1 | Type approval requirements — SOLAS 74 Reg. II-2/10. | — IMO MSC.1/Circ.1384. | B+D B+E B+F | ||
| MED/3.61a Inside air high expansion foam systems for the protection of machinery spaces, cargo pump rooms, vehicle and ro-ro spaces, special category spaces and cargo spaces Note: Inside/Outside air high expansion foam systems for the protection of machinery spaces, cargo pump rooms, vehicle and ro-ro spaces, special category spaces and cargo spaces shall be tested with the approved concentrate to the satisfaction of the Administration. Row 1 of 1 | Carriage and performance requirements — SOLAS 74 Reg. II-2/10, — IMO Res. MSC.98(73)-(FSS Code) 6, — IMO MSC.1/Circ.1528. | — IMO MSC.1/Circ.1384. | B+D B+E B+F | ||
| MED/3.61b Outside air high expansion foam systems for the protection of machinery spaces, cargo pump rooms, vehicle and ro-ro spaces, special category spaces and cargo spaces Note: Inside/Outside air high expansion foam systems for the protection of machinery spaces, cargo pump rooms, vehicle and ro-ro spaces, special category spaces and cargo spaces shall be tested with the approved concentrate to the satisfaction of the Administration. Row 1 of 1 | Type approval requirements — SOLAS 74 Reg. II-2/10. | — IMO MSC.1/Circ.1384. | B+D B+E B+F | ||
| MED/3.61b Outside air high expansion foam systems for the protection of machinery spaces, cargo pump rooms, vehicle and ro-ro spaces, special category spaces and cargo spaces Note: Inside/Outside air high expansion foam systems for the protection of machinery spaces, cargo pump rooms, vehicle and ro-ro spaces, special category spaces and cargo spaces shall be tested with the approved concentrate to the satisfaction of the Administration. Row 1 of 1 | Carriage and performance requirements — SOLAS 74 Reg. II-2/10, — IMO Res. MSC.98(73)-(FSS Code) 6, — IMO MSC.1/Circ.1528. | — IMO MSC.1/Circ.1384. | B+D B+E B+F | ||
| MED/3.62 Dry chemical powder extinguishing systems Row 1 of 2 | Type approval requirements — SOLAS 74 Reg. II-2/1. | — IMO MSC.1/Circ.1315. | B+D B+E B+F | 4.9.2027 (iii) | |
| MED/3.62 Dry chemical powder extinguishing systems Row 1 of 2 | Carriage and performance requirements — SOLAS 74 Reg. II-2/1. — IMO Res. MSC.5(48)-(IGC Code) 11, — IMO Res. MSC.391(95)-(IGF Code) 11, — IMO MSC.1/Circ./1617. | — IMO MSC.1/Circ.1315. | B+D B+E B+F | 4.9.2027 (iii) | |
| MED/3.62 Dry chemical powder extinguishing systems Row 2 of 2 | Type approval requirements — SOLAS 74 Reg. II-2/1. | — IMO MSC.1/Circ./1315 Rev1. | B+D B+E B+F | 4.9.2024 | |
| MED/3.62 Dry chemical powder extinguishing systems Row 2 of 2 | Carriage and performance requirements — SOLAS 74 Reg. II-2/1. — IMO Res. MSC.5(48)-(IGC Code) 11, — IMO Res. MSC.391(95)-(IGF Code) 11, — IMO MSC.1/Circ./1617. | — IMO MSC.1/Circ./1315 Rev1. | B+D B+E B+F | 4.9.2024 | |
| MED/3.63a Sample extraction smoke detection systems components: — control and indicating equipment. Electrical installations in ships Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 4 | Type approval requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. II-2/19, — SOLAS 74 Reg. II-2/20. | — IMO Res. MSC.98(73)-(FSS Code) 10, — EN 54-2:1997 incl. AC:1999 and A1:2006. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. And, as applicable for explosive atmospheres: — EN 60079-0:2012 incl. A11:2013. | B+D B+E B+F | 19.6.2018 | 12.8.2023 (iii) |
| MED/3.63a Sample extraction smoke detection systems components: — control and indicating equipment. Electrical installations in ships Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 4 | Carriage and performance requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. II-2/19, — SOLAS 74 Reg. II-2/20, — IMO Res. MSC.98(73)-(FSS Code) 10. | — IMO Res. MSC.98(73)-(FSS Code) 10, — EN 54-2:1997 incl. AC:1999 and A1:2006. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. And, as applicable for explosive atmospheres: — EN 60079-0:2012 incl. A11:2013. | B+D B+E B+F | 19.6.2018 | 12.8.2023 (iii) |
| MED/3.63a Sample extraction smoke detection systems components: — control and indicating equipment. Electrical installations in ships Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 2 of 4 | Type approval requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. II-2/19, — SOLAS 74 Reg. II-2/20. | — IMO Res. MSC.98(73)-(FSS Code) 10, — EN 54-2:1997 incl. AC:1999 and A1:2006. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. And, as applicable for explosive atmospheres: — EN IEC 60079-0:2018. | B+D B+E B+F | 12.8.2020 | 25.8.2024 (iii) |
| MED/3.63a Sample extraction smoke detection systems components: — control and indicating equipment. Electrical installations in ships Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 2 of 4 | Carriage and performance requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. II-2/19, — SOLAS 74 Reg. II-2/20, — IMO Res. MSC.98(73)-(FSS Code) 10. | — IMO Res. MSC.98(73)-(FSS Code) 10, — EN 54-2:1997 incl. AC:1999 and A1:2006. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. And, as applicable for explosive atmospheres: — EN IEC 60079-0:2018. | B+D B+E B+F | 12.8.2020 | 25.8.2024 (iii) |
| MED/3.63a Sample extraction smoke detection systems components: — control and indicating equipment. Electrical installations in ships Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 3 of 4 | Type approval requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. II-2/19, — SOLAS 74 Reg. II-2/20. | — IMO Res. MSC.98(73)-(FSS Code) 10. — EN 54-2:1997 incl. AC:1999 and A1:2006. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. And, as applicable for explosive atmospheres: — EN IEC 60079-0:2018 incl. AC:2020. | B+D B+E B+F | 25.8.2021 | 23.9.2028 (iii) |
| MED/3.63a Sample extraction smoke detection systems components: — control and indicating equipment. Electrical installations in ships Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 3 of 4 | Carriage and performance requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. II-2/19, — SOLAS 74 Reg. II-2/20, — IMO Res. MSC.98(73)-(FSS Code) 10. | — IMO Res. MSC.98(73)-(FSS Code) 10. — EN 54-2:1997 incl. AC:1999 and A1:2006. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. And, as applicable for explosive atmospheres: — EN IEC 60079-0:2018 incl. AC:2020. | B+D B+E B+F | 25.8.2021 | 23.9.2028 (iii) |
| MED/3.63a Sample extraction smoke detection systems components: — control and indicating equipment. Electrical installations in ships Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 4 of 4 (NEW ROW) | Type approval requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. II-2/19, — SOLAS 74 Reg. II-2/20. | — IMO Res. MSC.98(73)-(FSS Code) 10. — EN 54-2:1997 incl. AC:1999 and A1:2006. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. And, as applicable for explosive atmospheres: — EN IEC 60079-0:2018, incl. AC:2020-02, and A11:2024. | B+D B+E B+F | 23.9.2025 | |
| MED/3.63a Sample extraction smoke detection systems components: — control and indicating equipment. Electrical installations in ships Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 4 of 4 (NEW ROW) | Carriage and performance requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. II-2/19, — SOLAS 74 Reg. II-2/20, — IMO Res. MSC.98(73)-(FSS Code) 10. | — IMO Res. MSC.98(73)-(FSS Code) 10. — EN 54-2:1997 incl. AC:1999 and A1:2006. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. And, as applicable for explosive atmospheres: — EN IEC 60079-0:2018, incl. AC:2020-02, and A11:2024. | B+D B+E B+F | 23.9.2025 | |
| MED/3.63b Sample extraction smoke detection systems components: — power supply equipment Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 4 | Type approval requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. II-2/19, — SOLAS 74 Reg. II-2/20. | — IMO Res. MSC.98(73)-(FSS Code) 10, — EN 54-4:1997 incl. AC:1999, A1:2002 and A2:2006. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. And, as applicable for explosive atmospheres: — EN 60079-0:2012 incl. A11:2013. | B+D B+E B+F | 19.6.2018 | 12.8.2023 (iii) |
| MED/3.63b Sample extraction smoke detection systems components: — power supply equipment Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 4 | Carriage and performance requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. II-2/19, — SOLAS 74 Reg. II-2/20, — IMO Res. MSC.98(73)-(FSS Code) 10. | — IMO Res. MSC.98(73)-(FSS Code) 10, — EN 54-4:1997 incl. AC:1999, A1:2002 and A2:2006. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. And, as applicable for explosive atmospheres: — EN 60079-0:2012 incl. A11:2013. | B+D B+E B+F | 19.6.2018 | 12.8.2023 (iii) |
| MED/3.63b Sample extraction smoke detection systems components: — power supply equipment Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 2 of 4 | Type approval requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. II-2/19, — SOLAS 74 Reg. II-2/20. | — IMO Res. MSC.98(73)-(FSS Code) 10, — EN 54-4:1997 incl. AC:1999, A1:2002 and A2:2006. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. And, as applicable for explosive atmospheres: — EN IEC 60079-0:2018. | B+D B+E B+F | 12.8.2020 | 25.8.2024 (iii) |
| MED/3.63b Sample extraction smoke detection systems components: — power supply equipment Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 2 of 4 | Carriage and performance requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. II-2/19, — SOLAS 74 Reg. II-2/20, — IMO Res. MSC.98(73)-(FSS Code) 10. | — IMO Res. MSC.98(73)-(FSS Code) 10, — EN 54-4:1997 incl. AC:1999, A1:2002 and A2:2006. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. And, as applicable for explosive atmospheres: — EN IEC 60079-0:2018. | B+D B+E B+F | 12.8.2020 | 25.8.2024 (iii) |
| MED/3.63b Sample extraction smoke detection systems components: — power supply equipment Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 3 of 4 | Type approval requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. II-2/19, — SOLAS 74 Reg. II-2/20. | — IMO Res. MSC.98(73)-(FSS Code) 10. — EN 54-4:1997 incl. AC:1999, A1:2002 and A2:2006. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. And, as applicable for explosive atmospheres: — EN IEC 60079-0:2018 incl. AC:2020. | B+D B+E B+F | 25.8.2021 | 23.9.2028 (iii) |
| MED/3.63b Sample extraction smoke detection systems components: — power supply equipment Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 3 of 4 | Carriage and performance requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. II-2/19, — SOLAS 74 Reg. II-2/20, — IMO Res. MSC.98(73)-(FSS Code) 10. | — IMO Res. MSC.98(73)-(FSS Code) 10. — EN 54-4:1997 incl. AC:1999, A1:2002 and A2:2006. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. And, as applicable for explosive atmospheres: — EN IEC 60079-0:2018 incl. AC:2020. | B+D B+E B+F | 25.8.2021 | 23.9.2028 (iii) |
| MED/3.63b Sample extraction smoke detection systems components: — power supply equipment Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 4 of 4 (NEW ROW) | Type approval requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. II-2/19, — SOLAS 74 Reg. II-2/20. | — IMO Res. MSC.98(73)-(FSS Code) 10. — EN 54-4:1997 incl. AC:1999, A1:2002 and A2:2006. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. And, as applicable for explosive atmospheres: — EN IEC 60079-0:2018, incl. AC:2020-02, and A11:2024. | B+D B+E B+F | 23.9.2025 | |
| MED/3.63b Sample extraction smoke detection systems components: — power supply equipment Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 4 of 4 (NEW ROW) | Carriage and performance requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. II-2/19, — SOLAS 74 Reg. II-2/20, — IMO Res. MSC.98(73)-(FSS Code) 10. | — IMO Res. MSC.98(73)-(FSS Code) 10. — EN 54-4:1997 incl. AC:1999, A1:2002 and A2:2006. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. And, as applicable for explosive atmospheres: — EN IEC 60079-0:2018, incl. AC:2020-02, and A11:2024. | B+D B+E B+F | 23.9.2025 | |
| MED/3.63c Sample extraction smoke detection systems components: — aspiring smoke detectors Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 4 | Type approval requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. II-2/19, — SOLAS 74 Reg. II-2/20. | — IMO Res. MSC.98(73)-(FSS Code) 10, — EN 54-20:2006 incl. AC:2008. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. And, as applicable for explosive atmospheres: — EN 60079-0:2012 incl. A11:2013. | B+D B+E B+F | 19.6.2018 | 12.8.2023 (iii) |
| MED/3.63c Sample extraction smoke detection systems components: — aspiring smoke detectors Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 4 | Carriage and performance requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. II-2/19, — SOLAS 74 Reg. II-2/20, — IMO Res. MSC.98(73)-(FSS Code) 10. | — IMO Res. MSC.98(73)-(FSS Code) 10, — EN 54-20:2006 incl. AC:2008. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. And, as applicable for explosive atmospheres: — EN 60079-0:2012 incl. A11:2013. | B+D B+E B+F | 19.6.2018 | 12.8.2023 (iii) |
| MED/3.63c Sample extraction smoke detection systems components: — aspiring smoke detectors Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 2 of 4 | Type approval requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. II-2/19, — SOLAS 74 Reg. II-2/20. | — IMO Res. MSC.98(73)-(FSS Code) 10, — EN 54-20:2006 incl. AC:2008. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. And, as applicable for explosive atmospheres: — EN IEC 60079-0:2018. | B+D B+E B+F | 12.8.2020 | 25.8.2024 (iii) |
| MED/3.63c Sample extraction smoke detection systems components: — aspiring smoke detectors Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 2 of 4 | Carriage and performance requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. II-2/19, — SOLAS 74 Reg. II-2/20, — IMO Res. MSC.98(73)-(FSS Code) 10. | — IMO Res. MSC.98(73)-(FSS Code) 10, — EN 54-20:2006 incl. AC:2008. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. And, as applicable for explosive atmospheres: — EN IEC 60079-0:2018. | B+D B+E B+F | 12.8.2020 | 25.8.2024 (iii) |
| MED/3.63c Sample extraction smoke detection systems components: — aspiring smoke detectors Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 3 of 4 | Type approval requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. II-2/19, — SOLAS 74 Reg. II-2/20. | — IMO Res. MSC.98(73)-(FSS Code) 10, — EN 54-20:2006 incl. AC:2008. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. And, as applicable for explosive atmospheres: — EN IEC 60079-0:2018 incl. AC:2020. | B+D B+E B+F | 25.8.2021 | 23.9.2028 (iii) |
| MED/3.63c Sample extraction smoke detection systems components: — aspiring smoke detectors Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 3 of 4 | Carriage and performance requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. II-2/19, — SOLAS 74 Reg. II-2/20, — IMO Res. MSC.98(73)-(FSS Code) 10. | — IMO Res. MSC.98(73)-(FSS Code) 10, — EN 54-20:2006 incl. AC:2008. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. And, as applicable for explosive atmospheres: — EN IEC 60079-0:2018 incl. AC:2020. | B+D B+E B+F | 25.8.2021 | 23.9.2028 (iii) |
| MED/3.63c Sample extraction smoke detection systems components: — aspiring smoke detectors Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 4 of 4 (NEW ROW) | Type approval requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. II-2/19, — SOLAS 74 Reg. II-2/20. | — IMO Res. MSC.98(73)-(FSS Code) 10, — EN 54-20:2006 incl. AC:2008. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. And, as applicable for explosive atmospheres: — EN IEC 60079-0:2018, incl. AC:2020-02, and A11:2024. | B+D B+E B+F | 23.9.2025 | |
| MED/3.63c Sample extraction smoke detection systems components: — aspiring smoke detectors Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 4 of 4 (NEW ROW) | Carriage and performance requirements — SOLAS 74 Reg. II-2/7, — SOLAS 74 Reg. II-2/19, — SOLAS 74 Reg. II-2/20, — IMO Res. MSC.98(73)-(FSS Code) 10. | — IMO Res. MSC.98(73)-(FSS Code) 10, — EN 54-20:2006 incl. AC:2008. And as applicable, electrical and electronic installations in ships: — IEC 60092-504:2016, — IEC 60533:2015. And, as applicable for explosive atmospheres: — EN IEC 60079-0:2018, incl. AC:2020-02, and A11:2024. | B+D B+E B+F | 23.9.2025 | |
| MED/3.64 C class divisions Row 1 of 1 | Type approval requirements — SOLAS 74 Reg. II-2/3.10. | — IMO Res. MSC.307(88)-(2010 FTP Code), as amended. | B+D B+E B+F | ||
| MED/3.64 C class divisions Row 1 of 1 | Carriage and performance requirements — SOLAS 74 Reg. II-2/3.10, — SOLAS 74 Reg. II-2/3.33, — SOLAS 74 Reg. II-2/9, — IMO MSC/Circ.1120. | — IMO Res. MSC.307(88)-(2010 FTP Code), as amended. | B+D B+E B+F | ||
| MED/3.65 Fixed hydrocarbon gas detection system Row 1 of 5 | Type approval requirements — SOLAS 74 Reg. II-2/4. | — IMO MSC.1/Circ.1370, — EN 60079-0:2012 incl. A11:2013, — EN 60079-29-1:2016, — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 19.6.2018 | 12.8.2023 (iii) |
| MED/3.65 Fixed hydrocarbon gas detection system Row 1 of 5 | Carriage and performance requirements — SOLAS 74 Reg. II-2/4, — IMO Res. MSC.98(73)-(FSS Code) 16, — IMO MSC.1/Circ.1370, — IMO MSC.1/Circ.1527. | — IMO MSC.1/Circ.1370, — EN 60079-0:2012 incl. A11:2013, — EN 60079-29-1:2016, — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 19.6.2018 | 12.8.2023 (iii) |
| MED/3.65 Fixed hydrocarbon gas detection system Row 2 of 5 | Type approval requirements — SOLAS 74 Reg. II-2/4. | — IMO MSC.1/Circ.1370, — EN IEC 60079-0:2018, — EN 60079-29-1:2016, — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 12.8.2020 | 25.8.2024 (iii) |
| MED/3.65 Fixed hydrocarbon gas detection system Row 2 of 5 | Carriage and performance requirements — SOLAS 74 Reg. II-2/4, — IMO Res. MSC.98(73)-(FSS Code) 16, — IMO MSC.1/Circ.1370, — IMO MSC.1/Circ.1527. | — IMO MSC.1/Circ.1370, — EN IEC 60079-0:2018, — EN 60079-29-1:2016, — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 12.8.2020 | 25.8.2024 (iii) |
| MED/3.65 Fixed hydrocarbon gas detection system Row 3 of 5 | Type approval requirements — SOLAS 74 Reg. II-2/4. | — IMO MSC.1/Circ.1370, — EN IEC 60079-0:2018 incl. AC:2020, — EN 60079-29-1:2016, — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 25.8.2021 | 4.9.2027 (iii) |
| MED/3.65 Fixed hydrocarbon gas detection system Row 3 of 5 | Carriage and performance requirements — SOLAS 74 Reg. II-2/4, — IMO Res. MSC.98(73)-(FSS Code) 16, — IMO MSC.1/Circ.1370, — IMO MSC.1/Circ.1527. | — IMO MSC.1/Circ.1370, — EN IEC 60079-0:2018 incl. AC:2020, — EN 60079-29-1:2016, — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 25.8.2021 | 4.9.2027 (iii) |
| MED/3.65 Fixed hydrocarbon gas detection system Row 4 of 5 | Type approval requirements — SOLAS 74 Reg. II-2/4. | — IMO MSC.1/Circ.1370, — EN IEC 60079-0:2018 incl. AC:2020, — EN 60079-29-1:2016 incl. EN 60079-29-1:2016/A1:2022 and EN 60079-29-1:2016/A11:2022, — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 4.9.2024 | 23.9.2028 (iii) |
| MED/3.65 Fixed hydrocarbon gas detection system Row 4 of 5 | Carriage and performance requirements — SOLAS 74 Reg. II-2/4, — IMO Res. MSC.98(73)-(FSS Code) 16, — IMO MSC.1/Circ.1370, — IMO MSC.1/Circ.1527. | — IMO MSC.1/Circ.1370, — EN IEC 60079-0:2018 incl. AC:2020, — EN 60079-29-1:2016 incl. EN 60079-29-1:2016/A1:2022 and EN 60079-29-1:2016/A11:2022, — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 4.9.2024 | 23.9.2028 (iii) |
| MED/3.65 Fixed hydrocarbon gas detection system Row 5 of 5 (NEW ROW) | Type approval requirements — SOLAS 74 Reg. II-2/4. | — IMO MSC.1/Circ.1370, — EN IEC 60079-0:2018, incl. AC:2020-02, and A11:2024. — EN 60079-29-1:2016 incl. EN 60079-29-1:2016/A1:2022 and EN 60079-29-1:2016/A11:2022, — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 23.9.2025 | |
| MED/3.65 Fixed hydrocarbon gas detection system Row 5 of 5 (NEW ROW) | Carriage and performance requirements — SOLAS 74 Reg. II-2/4, — IMO Res. MSC.98(73)-(FSS Code) 16, — IMO MSC.1/Circ.1370, — IMO MSC.1/Circ.1527. | — IMO MSC.1/Circ.1370, — EN IEC 60079-0:2018, incl. AC:2020-02, and A11:2024. — EN 60079-29-1:2016 incl. EN 60079-29-1:2016/A1:2022 and EN 60079-29-1:2016/A11:2022, — IEC 60092-504:2016, — IEC 60533:2015. | B+D B+E B+F | 23.9.2025 | |
| MED/3.66 Evacuation guidance systems used as an alternative to low-location lighting systems. Row 1 of 1 | Type approval requirements — SOLAS 74 Reg. II-2/13. | — IMO MSC.1/Circ.1168. | B+D B+E B+F | ||
| MED/3.66 Evacuation guidance systems used as an alternative to low-location lighting systems. Row 1 of 1 | Carriage and performance requirements — SOLAS 74 Reg. II-2/13, — IMO MSC.1/Circ.1168. | — IMO MSC.1/Circ.1168. | B+D B+E B+F | ||
| MED/3.67 Helicopter facility foam fire-fighting appliances Row 1 of 1 | Type approval requirements — SOLAS 74 Reg. II-2/18. | — EN 13565-1:2019. | B+D B+E B+F | 12.8.2020 | |
| MED/3.67 Helicopter facility foam fire-fighting appliances Row 1 of 1 | Carriage and performance requirements — SOLAS 74 Reg. II-2/18, — IMO Res. MSC.98(73)-(FSS Code) 17. | — EN 13565-1:2019. | B+D B+E B+F | 12.8.2020 | |
| MED/3.68 Galley exhaust duct dixed fire extinguishing systems components Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 2 | Type approval requirements — SOLAS 74 Reg. II-2/9. | — ISO 15371:2015. | B+D B+E B+F | 16.3.2017 | 23.9.2028 (i) |
| MED/3.68 Galley exhaust duct dixed fire extinguishing systems components Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 1 of 2 | Carriage and performance requirements — SOLAS 74 Reg. II-2/9. | — ISO 15371:2015. | B+D B+E B+F | 16.3.2017 | 23.9.2028 (i) |
| MED/3.68 Galley exhaust duct dixed fire extinguishing systems components Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 2 of 2 (NEW ROW) | Type approval requirements — SOLAS 74 Reg. II-2/9. | — ISO 15371:2024. | B+D B+E B+F | 23.9.2025 | |
| MED/3.68 Galley exhaust duct dixed fire extinguishing systems components Note: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied. Row 2 of 2 (NEW ROW) | Carriage and performance requirements — SOLAS 74 Reg. II-2/9. | — ISO 15371:2024. | B+D B+E B+F | 23.9.2025 | |
| MED/3.69 Mobile water monitor for ships constructed on or after 1 January 2016 designed to carry five or more tiers of containers on or above the weather deck. Row 1 of 1 | Type approval requirements — SOLAS 74 Reg. I-2/10. | — IMO MSC.1/Circ.1472. | B+D B+E B+F | ||
| MED/3.69 Mobile water monitor for ships constructed on or after 1 January 2016 designed to carry five or more tiers of containers on or above the weather deck. Row 1 of 1 | Carriage and performance requirements — SOLAS 74 Reg. I-2/10, — SOLAS 74 Reg. I-2/19, — IMO Res. MSC.98(73)-(FSS Code) 12, — IMO MSC.1/Circ.1472, — IMO MSC.1/Circ.1550. | — IMO MSC.1/Circ.1472. | B+D B+E B+F | ||
| MED/3.70 Fire-fighting hoses: — semi-rigid hoses for fixed systems Row 1 of 1 | Type approval requirements — SOLAS 74 Reg. II-2/10, — SOLAS 74 Reg. X/3. | — EN 694:2014. | B+D B+E B+F | ||
| MED/3.70 Fire-fighting hoses: — semi-rigid hoses for fixed systems Row 1 of 1 | Carriage and performance requirements — SOLAS 74 Reg. II-2/10, — IMO Res. MSC.36(63)-(1994 HSC Code) 7, — IMO Res. MSC.97(73)-(2000 HSC Code) 7. | — EN 694:2014. | B+D B+E B+F | ||
| MED/3.71 Fixed firefighting hose systems — hose systems with lay-flat hose Row 1 of 1 | Type approval requirements — SOLAS 74 Reg. II-2/10, — SOLAS 74 Reg. X/3. | — EN 671-2:2012. | B+D B+E B+F | 16.3.2017 | |
| MED/3.71 Fixed firefighting hose systems — hose systems with lay-flat hose Row 1 of 1 | Carriage and performance requirements — SOLAS 74 Reg. II-2/10, — IMO Res. MSC.36(63)-(1994 HSC Code) 7, — IMO Res. MSC.97(73)-(2000 HSC Code) 7. | — EN 671-2:2012. | B+D B+E B+F | 16.3.2017 |
4. Navigation equipment
Reading this document does not replace reading the official text published in the Official Journal of the European Union. We assume no responsibility for any inaccuracies arising from the conversion of the original to this format.
This text is published under EUR-Lex's own terms of reuse, not a Legalize or public-domain licence.
EUR-Lex
Creative Commons Attribution 4.0 International (CC BY 4.0)
© European Union, https://eur-lex.europa.eu — Source: EUR-Lex (Publications Office of the European Union). Reused under the Creative Commons Attribution 4.0 International (CC BY 4.0) licence. Only EU legislation published in the printed Official Journal of the European Union is deemed authentic; consolidated texts are reproduced here for documentation purposes and have been reformatted to Markdown.