S.I. No. 804/2007 - Stores for Explosives Order 2007

Type Statutory Instrument
Publication 2007-12-14
Last updated 2024-03-06
State In force superseded text
Text As published
articles 16

This is the act as published. Later amendments are not folded into the text below: each one is a separate act in this repository and an entry in this law's history.

1 amending act · 2024-03-06, LOCAL GOVERNMENT (MAYOR OF LIMERICK) AND MISCELLANEOUS PROVISIONS ACT 2024

Reform history JSON API

S.I. No. 804 of 2007

STORES FOR EXPLOSIVES ORDER 2007

Notice of the making of this Statutory Instrument was published in

“Iris Oifigiúil” of 14th December, 2007.

The Government, in exercise of the powers conferred on them by sections 16, 39, 40, 43, 46 and 83 of the Explosives Act 1875, as adapted, and on the recommendation of the Minister for Justice, Equality and Law Reform, hereby order as follows:

Citation

1.

1.

This Order may be cited as the Stores for Explosives Order 2007.

Commencement

2.

2.

This Order comes into operation on 11 December 2007.

Interpretation

3.

3.

(1) In this Order—

“Act” means the Explosives Act 1875;

“ADR” means the European Agreement concerning the international carriage of dangerous goods by road, done at Geneva on 30 September 1957, as amended by the Protocols done at New York on 21 August 1975 and at Geneva on 28 October 1993;

“ANBI” means ammonium nitrate blasting intermediate (that is to say, a non-sensitised mixture of, primarily, ammonium nitrate and other substances not in themselves explosive) which—

“black powder” means an intimate mixture, with or without sulphur, of charcoal or other carbon with potassium nitrate or sodium nitrate, whether the mixture is in meal, granular, compressed or pelletised form, being an explosive substance numbered UN No. 0027 or 0028;

“brick-built” means having an outer structure which is wholly or mainly of brick, concrete, stone or other similar material;

“bridleway” means a path over which members of the public have a right of way on foot, on horseback or while leading a horse or cycling;

“competent person” means a person—

or of either of those factors, has sufficient experience and knowledge to operate the store in accordance with the requirements of this Order, and

“controlled substance” has the meaning given to it in Article 5;

“conventional explosive” means a blasting explosive and accessories, including detonators and boosters, that are normally used in the mining, quarrying and construction industries;

“distance”, except in the definition of “reference zone”, means minimum distance;

“explosive” means an explosive within the meaning of section 2 of the Act and orders made or to be made under section 104 thereof and includes—

but does not include an explosive substance produced as part of a manufacturing process which later reprocesses it to produce a substance which is not an explosive substance;

“explosive article” means an article containing one or more than one explosive substance;

“explosive substance” means a substance which—

but does not include a substance in a solely gaseous form or in the form of vapour;

“fire authority” has the meaning given to it by the Fire Services Act 1981 ;

“footpath” means a path (not being a footway) over which there is a public right of way for pedestrians only;

“footway” means that part of a road which is primarily for use by pedestrians;

“Guidance Document on Fire Safety” means the document entitled “Guidance Document on Fire Safety in Stores for Explosives”, a copy of which is available from the local authority concerned, or any amendment thereof;

“hazard type”, in relation to an explosive, means one of the categories of explosives mentioned in Article 4;

“inspector” means a person appointed as such under section 53 of the Act;

“licence” means a licence under section 15 of the Act in respect of a store, and cognate words are to be construed accordingly;

“lightly-used road” means a road used ordinarily by more than 20 and not more than 500 vehicles every 24 hours;

“major road” means a road used ordinarily by more than 10,000 vehicles every 24 hours;

“mass explosion”, in relation to a body of explosives, means an explosion in which the entire body of the explosives explodes as one;

“metal-built” means built wholly or mainly of steel or other metal;

“Minister” means the Minister for Justice, Equality and Law Reform;

“minor road” means a road (other than a major road) used ordinarily by more than 500 vehicles every 24 hours;

“mound” means a barrier for intercepting fragments and debris caused by an explosion in a building or store for the purpose of—

and cognate words are to be construed accordingly;

“oxidising controlled substance” means—

“place of public resort” means a place where more than 100 persons are present, or are likely to be present, at any one time on a weekly or more frequent basis;

“proper shipping name” is that portion of the entry most accurately describing the goods in Column 2 of Table A in Chapter 3.2 of Annex A to the ADR and shown in upper case characters;

“pyrotechnic article” means any article which—

“pyrotechnic substance” means a substance of a kind designed to produce an effect by heat, light, sound, gas or smoke or a combination of any of them as a result of a non-detonative, self-sustaining, exothermic chemical reaction;

“quantity of explosive” means—

“reference zone” means an area around a store having a radius from the centre point of the store specified in column 5 of the relevant table in Schedule 4;

“relevant table” is the table of separation distances which applies, by virtue of paragraph 1 of Schedule 4, in relation to the storage of specified quantities of explosives;

“road” means any thoroughfare on which the movement of vehicles is allowed;

“separation distance” means the minimum distance between a store and a building or other place in or at which people are, or are likely to be, present either all the time or from time to time;

“shooters powder” means—

“site” means an area, or adjoining areas under the control of the same person, in which a store is situated, and includes areas under such control that are separated only by a road, railway or inland waterway;

“small arms ammunition” means explosive articles numbered UN No. 0012, 0014 or 0055 and intended exclusively for use in small arms;

“smokeless powder” means an explosive substance numbered UN No. 0160 or 0161;

“store” means a building, an enclosed area, an excavation, or a metal structure, in which explosives are, or are to be, stored;

“UN Hazard Code” means the classification code for dangerous substances and articles shown in Column 3b of Table A in Chapter 3.2 of Annex A to the ADR and consisting of a hazard division number describing the main hazard associated with the substance or article concerned, together with a compatibility group letter indicating the other explosive substances or articles with which it can be stored or transported;

“UN Recommendations” means the recommendations contained in the manual published by the United Nations and entitled “Fifteenth Revised Edition of the Recommendations prepared by the United Nations Committee of Experts on the Transport of Dangerous Goods” (ISBN 92-1-139067-2) or a later revised edition of those Recommendations;

“UN No.” means the United Nations Serial Number, that is to say, one of the four-digit numbers devised by the United Nations as a means of identifying types of explosives in accordance with the UN Recommendations;

“vulnerable building” means a building of 4 storeys or more above ground where its masonry, glass or other cladding is suspended from the structural framework;

“waterway” means any navigable body of water and includes a river, channel or canal.

and

Hazard types

4.

4.

(1) For the purposes of this Order, explosives are divided into the following hazard types:

“Controlled substance”

5.

5.

“Controlled substance” means—

Transitional arrangements for store licences

6.

6.

(1) Subject to paragraph (2), a store licence granted under section 15 of the Act and in force on the commencement of this Order is deemed to have been granted under that section.

Store licences

7.

7.

(1) An application for the grant or renewal of a store licence under section 15 of the Act shall be made to the local authority of the place in which the store is proposed to be or is situated.

Variation of store licence

8.

8.

A local authority may, with the prior approval of the Minister, vary a store licence or any of the conditions to which it is subject where—

Revocation of store licence

9.

9.

(1) Subject to paragraph (2), a local authority may revoke a store licence where—

Construction of stores (general)

10.

10.

(1) The following provisions have effect in relation to a store.

and

Stores for oxidising controlled substances: additional construction requirements

11.

11.

(1) Without prejudice to the generality of Article 10, the following additional requirements apply in relation to the construction of a store for oxidising controlled substances.

Operation of stores

12.

12.

The licensee of a store shall ensure that the store is at all times operated under the supervision of a competent person.

Separation distances

13.

13.

(1) Subject to the provisions of this Article, the licensee of a store shall ensure that the relevant separation distance specified in the relevant table in Schedule 4 is maintained between the store and a building or other place outside the site and referred to in that Schedule.

Special provision in relation to storage of controlled substances not exceeding 50,000 kg.

14.

14.

(1) In this Article, “controlled substance” means a quantity of a controlled substance or substances not exceeding 50,000 kilograms.

Fire and explosion assessment and safety measures

15.

15.

(1) Any licensee or a person who intends to store explosives shall cause a written assessment of the site and of activities related to the storage or proposed storage to be prepared by a competent person for the purpose of—

Revocations

16.

16.

The following Orders are revoked:

SCHEDULE 1 APPLICATION FOR GRANT OR RENEWAL OF EXPLOSIVES STORE LICENCE

(Note: This form should be read in conjunction with the Explosives Act 1875 and Stores for Explosives Order 2007 (S.I. xxx of 2007), and Guidance Document on Fire Safety in Stores for Explosives. See footnotes on completing each section of form).

1.

Applicant

Name (if applicant is an individual)Address
Company Name
Name of Company Secretary
Registered Office
Name and evidence of competence of person directly responsible for supervising operations within store
Phone
Fax
2.

Location of proposed store 1

1 Location: Scaled maps should accompany the application, one of scale 1:2500, showing the entire site and all occupied buildings, roads, factories, etc. within 1000m of the site and a block plan of scale 1:500 (approx), showing actual store (outlined in red) and remainder of the site under the control or ownership of the applicant, and a plan of the actual store of scale 1:50.

County
Parish
Place
3.

Checklist for construction of proposed store 2

2 Construction requirements are specified in the Order. PM 82 is an electrical specification for explosives buildings.

Type Description Yes/No
SM Solid brick or block or reinforced concrete, mounded?
SU Solid brick or block or reinforced concrete, unmounded?
MM Metal, mounded?
MU Metal, without detonator annex, unmounded?
MDU Metal, with detonator annex, unmounded?
UG Underground?
OS Open stack?
Lighting Compliant with PM 82?
Lightning conductor Compliant with PM 82?
Security Compliant with Garda Síochána CPO requirements?
Fire safety Compliant with Guidance Document on Fire Safety in Stores for Explosives?
4.

Types of explosives proposed to be stored: 3

3 Proper shipping names, UN number and hazard code can be obtained from the manufacturer or the Competent Authority Document, which classifies explosives for transport. For definitions and infomation on hazard types, see Articles 3 and 4 of Order.

Proper shipping name UN number UN hazard code Hazard type
5.

Separation distances from store to nearest facility 4

4 See Schedule 4 of Order for tables and explanations of separation distances.

Facility Distance (m)
Occupied building on site
Occupied building off site
Place of public resort
Major road
Vulnerable building
Minor road/railway line
Bridleway/footpath/footway/lightly-used road/waterway
Reference zone radius 5

5 See Article 3 of, and Schedule 4 to, Order for explanation of reference zone.

6.

Number of dwellings in reference zone 6 :

6 This should be determined by a physical survey, using scaled map as reference.

7.

Maximum quantity of explosives proposed to be stored 7

7 This quantity is normally the net explosive mass in kg, and the maximum quantity permitted depends on available separation distances. To calculate the maximum permitted quantity, proceed as follows, in accordance with Schedule 4 of the Order, for each hazard type of explosives proposed to be stored:a. Select correct table depending on store construction and hazard type.b. Use appropriate line for proposed quantity of explosives.c. Ascertain whether high-density or low-density distance is appropriate, having regard to paragraphs 3 to 6 of Schedule 4.d. Compare required separation distance from table against actual available distance.e. If required distance exceeds available distance, reduce proposed quantity of explosives until available distance equals or exceeds required distance.f. The quantity so ascertained is the maximum permitted quantity.

Hazard type Maximum quantity proposed (kg)
1
2
3
4
Controlled substances
ANBI
Ammonium nitrate
Other
8.

Written assessments referred to in Article 15 of Order

(To be attached on first application for licence.)

Signature of Applicant 8

8 Submit form with maps and fee to Secretary of local authority, with copies to Government Inspector of Explosives, Department of Justice, Equality and Law Reform, 94 St. Stephens Green, Dublin 2.

.........................................................................................................

(Block capitals)

Date: .............................................................

SCHEDULE 2 LICENCE TO STORE EXPLOSIVES OR CONTROLLED SUBSTANCES

EXPLOSIVES ACT 1875

STORES FOR EXPLOSIVES ORDER 2007

Licence Number................

1.

The (name of local authority) hereby grants to................. (name and address of licensee) a licence under section 15 of the Explosives Act 1875 to store the following explosives/controlled substances at.........(address) up to an amount not exceeding that specified below in respect of each explosive/controlled substance:

Proper shipping name of explosive/ controlled substance UN number UN hazard code Hazard type 9 Maximum permitted net quantity (kg)
2.

This licence is subject to the following condition(s):

3.

This licence expires on: ..........................., unless earlier revoked.

Signed on behalf of (name of local authority):

........................................................................

Position: ...................................................

Date: ............................

SCHEDULE 3 SAFETY MEASURES IN STORES FOR EXPLOSIVES

1.

Measures to prevent fire or explosion:

2.

Measures to limit extent of fire or explosion:

3.

Measures to protect persons from effects of fire and explosion:

4.

Measures to ensure safe systems of work:

SCHEDULE 4 TABLES OF SEPARATION DISTANCES

1.

(1) Where the storage is of—

2.

Subject to paragraphs 3 and 4, the separation distance between a store and any building, place of public resort or major road is the distance specified in column 2 (low-density distance) of the relevant table corresponding to the quantity of explosives shown in column 1 of the table.

3.

Subject to paragraph 4, where—

the separation distance between the store and any such dwelling is the high-density distance (if any) specified in the corresponding line of column 3 of the table.

4.

For the purposes of this Order, the radius for a reference zone is the distance (if any) specified in the entry in column 5 (reference zone radius) of Table 1, 3, 4 or 5 corresponding to the quantity of explosives shown in column 1 of the table concerned.

5.

Where there is a dash in a column headed “high-density distance”, the low-density distance applies.

6.

The separation distance between a store and any vulnerable building is the distance (if any) specified in column 4 (vulnerable building distance) of the relevant table corresponding to the quantity of explosives shown in column 1 of the table.

7.

The separation distance between a store and any minor road or railway line is half the distance shown in column 2 of the relevant table corresponding to the quantity of explosives shown in column 1 of the table, and that between a store and any bridleway, footpath, footway, lightly-used road or waterway is one-third of that distance.

8.

A separation distance is measured in the horizontal plane from the nearest outside edge of the building or place where explosives are stored to the nearest point of the building or place in relation to which the separation distance applies.

9.

Where there is more than one store on a site, the appropriate separation distances applicable to the stores shall be determined by an inspector.

10.

Any separation distance specified in this Schedule is subject to modification where topographical features are likely to affect the direction and distance of blast effects or fragment throw: if any such feature is present, the local authority concerned shall seek advice in relation to the applicable separation distance from an inspector.

11.

For separation distances between a store and a workshop or process area where explosives are removed from their transport packaging, e.g. for preparing fraction packs, a local authority shall also seek advice from an inspector.

12.

For the purposes of this Schedule—

Table 1: Hazard Type 1 explosive in brick-built mounded store Table 1: Hazard Type 1 explosive in brick-built mounded store Table 1: Hazard Type 1 explosive in brick-built mounded store Table 1: Hazard Type 1 explosive in brick-built mounded store Table 1: Hazard Type 1 explosive in brick-built mounded store Table 1: Hazard Type 1 explosive in brick-built mounded store
1 2 3 4 5 6
Quantity of explosives Low-density distance High-density distance Vulnerable building distance Reference zone radius Maximum number of dwellings in reference zone
(kg.) (m) (m) (m) (m)
0. 1-25 101 - 101 - -
25-50 107 - 107 - -
50-75 112 - 112 - -
75-100 118 - 118 - -
100-150 128 142 128 257 81
150-200 139 156 139 278 96
200-300 161 180 161 322 128
300-400 183 - 183 - -
400-450 193 - 193 - -
450-500 204 - 204 - -
500-600 204 - 216 - -
600-700 204 231 238 408 206
700-800 204 238 260 408 206
800-900 204 245 280 408 206
900-1000 204 250 300 408 206
1000-1100 204 255 319 408 206
1100-1200 204 259 337 408 206
1200-1300 204 263 354 408 206
1300-1400 204 266 370 408 206
1400-1500 204 269 386 408 206
1500-1600 204 272 402 408 206
1600-1700 208 274 416 416 214
1700-1800 215 277 431 431 229
1800-1900 222 279 444 444 244
1900-2000 229 281 458 458 259
--- --- ---
Table 2: Hazard Type 1 explosive in brick-built unmounded store Table 2: Hazard Type 1 explosive in brick-built unmounded store Table 2: Hazard Type 1 explosive in brick-built unmounded store
1Quantity of explosives(kg.) 2 Low-density distance(m) 3 Vulnerable building distance(m)
0. 1-25 141 141
25-50 160 160
50-75 180 180
75-100 199 199
100-150 230 230
150-200 256 256
200-300 293 293
300-400 320 320
400-450 331 331
450-500 340 340
500-600 355 355
600-700 367 367
700-800 377 377
800-900 385 385
900-1000 392 392
1000-1100 398 398
1100-1200 403 403
1200-1300 408 408
1300-1400 412 412
1400-1500 415 415
1500-1600 418 418
1600-1700 421 421
1700-1800 424 431
1800-1900 426 444
1900-2000 428 458
--- --- --- --- --- ---
Table 3: Hazard Type 1 explosive in metal-built mounded store Table 3: Hazard Type 1 explosive in metal-built mounded store Table 3: Hazard Type 1 explosive in metal-built mounded store Table 3: Hazard Type 1 explosive in metal-built mounded store Table 3: Hazard Type 1 explosive in metal-built mounded store Table 3: Hazard Type 1 explosive in metal-built mounded store
1 2 3 4 5 6
Quantity of explosives Low-density distance High-density distance Vulnerable building distance Reference zone radius Maximum number of dwellings in reference zone
(kg.) (m) (m) (m) (m)
0. 1-25 34 45 40 68 6
25-50 37 45 48 74 7
50-75 40 45 54 80 8
75-100 43 48 66 86 9
100-150 49 55 86 97 12
150-200 54 62 104 109 15
200-300 68 76 136 136 23
300-400 83 - 165 - -
400-450 89 - 178 - -
450-500 96 - 191 - -
500-600 108 - 216 - -
600-700 119 - 238 - -
700-800 130 - 260 - -
800-900 140 - 280 - -
900-1000 150 - 300 - -
1000-1100 159 - 319 - -
1100-1200 168 - 337 - -
1200-1300 177 - 354 - -
1300-1400 185 - 370 - -
1400-1500 193 - 386 - -
1500-1600 201 - 402 - -
1600-1700 208 - 416 - -
1700-1800 215 - 431 - -
1800-1900 222 - 444 - -
1900-2000 229 - 458 - -
--- --- --- --- --- ---
Table 4: Hazard Type 1 explosive in metal-built unmounded store without detonator annex attached Table 4: Hazard Type 1 explosive in metal-built unmounded store without detonator annex attached Table 4: Hazard Type 1 explosive in metal-built unmounded store without detonator annex attached Table 4: Hazard Type 1 explosive in metal-built unmounded store without detonator annex attached Table 4: Hazard Type 1 explosive in metal-built unmounded store without detonator annex attached Table 4: Hazard Type 1 explosive in metal-built unmounded store without detonator annex attached
1 2 3 4 5 6
Quantity of explosives Low-density distance High-density distance Vulnerable building distance Reference zone radius Maximum number of dwellings in reference zone
(kg.) (m) (m) (m) (m)
0. 1-10 23 30 40 46 3
10-20 29 35 42 57 4
20-30 33 39 44 65 5
30-40 36 42 46 71 6
40-50 38 44 48 76 7
50-60 40 46 48 80 8
60-70 42 48 52 84 9
70-80 43 50 57 87 9
80-90 44 52 61 89 10
90-100 45 55 66 91 10
100-110 46 57 70 93 11
110-120 47 59 74 95 11
120-130 48 62 78 97 12
130- 140 49 64 82 98 12
140-150 50 66 86 100 12
150-160 51 68 90 102 13
160-170 52 71 93 104 13
170-180 53 73 97 106 14
180-190 54 75 101 108 14
190-200 55 78 104 110 15
200-300 68 101 136 136 23
300-400 83 124 165 165 34
400-450 89 135 178 178 39
450-500 96 138 191 191 45
500-600 108 144 216 216 57
600-700 119 150 238 238 70
700-800 130 156 260 260 83
800-900 140 162 280 280 97
900-1000 150 168 300 300 111
1000-1100 159 168 319 318 111
1100-1200 168 - 337 - -
1200-1300 177 - 354 - -
1300-1400 185 - 370 - -
1400-1500 193 - 386 - -
--- --- --- --- --- ---
Table 4: Hazard Type 1 explosive in metal-built unmounded store without detonator annex attached Table 4: Hazard Type 1 explosive in metal-built unmounded store without detonator annex attached Table 4: Hazard Type 1 explosive in metal-built unmounded store without detonator annex attached Table 4: Hazard Type 1 explosive in metal-built unmounded store without detonator annex attached Table 4: Hazard Type 1 explosive in metal-built unmounded store without detonator annex attached Table 4: Hazard Type 1 explosive in metal-built unmounded store without detonator annex attached
1 2 3 4 5 6
Quantity of explosives Low-density distance High-density distance Vulnerable building distance Reference zone radius Maximum number of dwellings in reference zone
(kg.) (m) (m) (m) (m)
1500-1600 201 - 402 - -
1600-1700 208 - 416 - -
1700-1800 215 - 431 - -
1800-1900 222 - 444 - -
1900-2000 229 - 458 - -
--- --- --- --- --- ---
Table 5: Hazard Type 1 explosive in metal-built unmounded store with detonator annex attached Table 5: Hazard Type 1 explosive in metal-built unmounded store with detonator annex attached Table 5: Hazard Type 1 explosive in metal-built unmounded store with detonator annex attached Table 5: Hazard Type 1 explosive in metal-built unmounded store with detonator annex attached Table 5: Hazard Type 1 explosive in metal-built unmounded store with detonator annex attached Table 5: Hazard Type 1 explosive in metal-built unmounded store with detonator annex attached
1 2 3 4 5 6
Quantity of explosives Low-density distance High-density distance Vulnerable building distance Reference zone radius Maximum number of dwellings in reference zone
(kg.) (m) (m) (m) (m)
0. 1-25 38 53 54 74 11
25-50 43 53 54 86 11
50-75 48 60 54 96 11
75-100 53 77 66 106 14
100-150 63 110 86 127 20
150-200 74 143 104 147 27
200-300 94 209 136 188 44
300-400 115 275 165 229 65
400-450 125 308 178 250 77
450-500 128 309 191 257 81
500-600 135 311 216 270 90
600-700 142 312 238 283 99
700-800 148 314 260 297 109
800-900 155 316 280 310 119
900-1000 162 318 300 324 129
1000-1100 169 319 319 337 140
1100-1200 175 321 337 350 152
1200-1300 182 323 354 364 163
1300-1400 189 325 370 377 176
1400-1500 195 326 386 391 188
1500-1600 202 328 402 404 202
1600-1700 209 330 416 417 215
1700-1800 215 332 431 431 229
1800-1900 222 333 444 444 244
1900-2000 229 335 458 458 259
--- --- ---
Table 6: Hazard Type 2 explosive where some or all items exceed 0.7kg. net mass Table 6: Hazard Type 2 explosive where some or all items exceed 0.7kg. net mass Table 6: Hazard Type 2 explosive where some or all items exceed 0.7kg. net mass
1Quantity of explosives(kg.) 2 Low-density distance (m) 3Vulnerable building distance(m)
0. 1-25 45 90
25-50 88 176
50-75 108 216
75-100 129 238
100-150 148 296
150-200 168 336
200-300 191 382
300-400 207 414
400-450 213 426
450-500 219 438
500-600 226 452
600-700 233 466
700-800 240 480
800-900 248 496
900-1000 256 512
1000-1100 259 518
1100-1200 262 524
1200-1300 266 532
1300-1400 270 540
1400-1500 274 548
1500-1600 278 556
1600-1700 282 564
1700-1800 286 572
1800-1900 288 576
1900-2000 292 592
--- --- ---
Table 7: Hazard Type 2 explosive where no item exceeds 0.7kg. net mass Table 7: Hazard Type 2 explosive where no item exceeds 0.7kg. net mass Table 7: Hazard Type 2 explosive where no item exceeds 0.7kg. net mass
1Quantity of explosives 2Low-density distance 3 Vulnerable building distance
(kg.) (m) (m)
0. 1-25 37 76
25-50 43 86
50-75 47 94
75-100 51 102
100-150 56 112
150-200 60 120
200-300 66 132
300-400 71 142
400-450 73 146
450-500 74 148
500-600 76 152
600-700 78 158
700-800 81 162
800-900 84 164
900-1000 87 174
1000-1100 88 176
1100-1200 89 178
1200-1300 90 180
1300-1400 91 182
1400-1500 92 184
1500-1600 94 188
1600-1700 95 190
1700-1800 97 194
1800-1900 99 198
1900-2000 101 202
--- ---
Table 8: Hazard Type 3 explosive Table 8: Hazard Type 3 explosive
1Quantity of explosives(kg.) 2 Low-density distance(m)
0. 1-5 -
5-10 14
10-15 16
15-20 18
20-25 19
25-50 23
50-75 25
75-100 29
100-150 33
150-200 37
200-300 42
300-400 47
400-450 47
450-500 50
500-600 51
600-700 53
700-800 54
800-900 55
900-1000 63
1000-1100 70
1100-1200 71
1200-1300 72
1300-1400 73
1400-1500 74
1500-1600 75
1600- 1700 76
1700-1800 78
1800-1900 79
1900-2000 80
--- ---
Table 9: Hazard Type 4 explosive Table 9: Hazard Type 4 explosive
1 Quantity of explosives(kg.) 2 Low-density distance(m)
0. 1-25 0
25-300 1
300-340 2
340-370 3
370-400 4
400-450 5
450-500 6
500-550 7
550-600 8
600-650 9
650-700 10
700-750 11
750-800 12
800-900 13
900-950 14
950-1000 15
1000-1100 16
1100-1150 17
1150-1200 18
1200-1300 19
1300-1350 20
1350-1400 21
1400-1450 22
1450-1550 23
1550-1600 24
1600-1650 25
1650-1700 26
1700-1800 27
1800-1850 28
1850-1900 29
1900-2000 30
--- --- --- --- --- ---
Table 10: Separation distance between explosives store and controlled substance Table 10: Separation distance between explosives store and controlled substance Table 10: Separation distance between explosives store and controlled substance Table 10: Separation distance between explosives store and controlled substance Table 10: Separation distance between explosives store and controlled substance Table 10: Separation distance between explosives store and controlled substance
1 2 3 4 5 6
Quantity ofexplosive Distance where controlled substance is AN passing the detonation resistance test or an AN blasting intermediate in UN 3375 (mounded store) Distance where controlled substance is AN passing the detonation resistance test or an AN blasting intermediate in UN 3375 (unmounded store) Distance where controlled substance is AN not passing the detonation resistance test or an AN blasting intermediate not in UN 3375 (mounded store) Distance where controlled substance is AN not passing the detonation resistance test or an AN blasting intermediate not in UN 3375 (unmounded store) Minimumthickness ofartificialmound
(kg.) (m) (m) (m) (m) (cm)
Under 50 1 5 3 20 30
50-100 1 7 4 23 30
100-200 1 8 5 29 30
200-500 2 11 7 41 30
500-1000 2 15 9 55 30
1000-2000 3 19 11 68 40

Note: In this Table, “AN” means ammonium nitrate.

GIVEN under the Official Seal of the Government,

11 December 2007

BERTIE AHERN

Taoiseach

EXPLANATORY NOTE

(This note is not part of the Instrument and does not purport to be a legal interpretation).

This Order regulates the licensing, construction, operation, separation distances, fire and explosion assessment and safety measures associated with stores for explosives as licensed by the local authorities.

This Order revokes and replaces the Stores for Explosives Order, 1955 ( S.I. No. 42 of 1955 ).

Footnotes

1

Location: Scaled maps should accompany the application, one of scale 1:2500, showing the entire site and all occupied buildings, roads, factories, etc. within 1000m of the site and a block plan of scale 1:500 (approx), showing actual store (outlined in red) and remainder of the site under the control or ownership of the applicant, and a plan of the actual store of scale 1:50.

2

Construction requirements are specified in the Order. PM 82 is an electrical specification for explosives buildings.

3

Proper shipping names, UN number and hazard code can be obtained from the manufacturer or the Competent Authority Document, which classifies explosives for transport. For definitions and infomation on hazard types, see Articles 3 and 4 of Order.

4

See Schedule 4 of Order for tables and explanations of separation distances.

5

See Article 3 of, and Schedule 4 to, Order for explanation of reference zone.

6

This should be determined by a physical survey, using scaled map as reference.

7

This quantity is normally the net explosive mass in kg, and the maximum quantity permitted depends on available separation distances. To calculate the maximum permitted quantity, proceed as follows, in accordance with Schedule 4 of the Order, for each hazard type of explosives proposed to be stored:a. Select correct table depending on store construction and hazard type.b. Use appropriate line for proposed quantity of explosives.c. Ascertain whether high-density or low-density distance is appropriate, having regard to paragraphs 3 to 6 of Schedule 4.d. Compare required separation distance from table against actual available distance.e. If required distance exceeds available distance, reduce proposed quantity of explosives until available distance equals or exceeds required distance.f. The quantity so ascertained is the maximum permitted quantity.

8

Submit form with maps and fee to Secretary of local authority, with copies to Government Inspector of Explosives, Department of Justice, Equality and Law Reform, 94 St. Stephens Green, Dublin 2.

9

See Article 4 of Order for explanation of hazard type.

This document does not substitute the official text published in the Irish Statute Book. We accept no responsibility for any inaccuracies arising from the transcription of the original into this format.

This text is published under Irish Statute Book's own terms of reuse, not a Legalize or public-domain licence. Irish Statute Book
CC-BY 4.0 (Oireachtas Open Data PSI Licence)
Contains Irish Public Sector Information licensed under the Oireachtas (Houses of the Oireachtas) Open Data PSI Licence / Creative Commons Attribution 4.0 International, sourced from https://www.irishstatutebook.ie.