The Factories Act 1961 etc. (Metrication) Regulations 1983

Type Statutory-Instrument
Publication 1983-07-07
State In force
Department Westlaw
PDF Download
articles Not indexed
Reform history JSON API

Made: 7th July 1983

Laid before Parliament: 21st July 1983

Coming into Operation: 12th August 1983

The Secretary of State, in exercise of the powers conferred on him by sections 15(1) and (3)(a), 49 and 82(3)(a) of the Health and Safety at Work etc. Act 1974[^f00001] (“the 1974 Act”) and of all other powers enabling him in that behalf and for the purpose of giving effect without modifications to proposals submitted to him by the Health and Safety Commission under section 11(2)(d) of the 1974 Act after the carrying out by the said Commission of consultations in accordance with section 50(3) of that Act, hereby makes the following Regulations:—

Citation and commencement

1

These Regulations may be cited as the Factories Act 1961 etc. (Metrication) Regulations 1983 and shall come into operation on 12th August 1983.

Amendment of section 19(1) of the Factories Act 1961 to alter standards of safety

2

Section 19(1) of the Factories Act 1961[^f00002] (which relates to self-acting machines) shall be amended by substituting for the measurement “eighteen inches” the measurement “500 millimetres”.

Amendments to the Factories Act 1961 to substitute metric measurements for imperial measurements

3

Application to existing premises and plant or premises and plant under construction

4

Amendments to the Abstract of Factories Act Order 1973

5

58.

Metrication: Where any premises or plant in existence or under construction immediately before the coming into operation of the Factories Act 1961 etc. (Metrication) Regulations 1983 complied with the Factories Act 1961 as then in force, then those premises or that plant shall be deemed to comply with that Act as amended by those Regulations except that section 3(2) of the Factories Act 1961 as likewise amended and which is referred to in paragraph 3 of this Schedule shall apply to all relevant workrooms whether or not in existence or under construction immediately before the coming into operation of these Regulations.

SCHEDULE 1 — AMENDMENTS TO THE FACTORIES ACT 1961

(1) (2) (3) (4)
Provision to be amended Subject-matter of measurement Present measurement Measurement to be substituted
The Factories Act 1961
Section 2(2) Minimum amount of cubic space per person employed in a workroom Four hundred cubic feet 11 cubic metres
Section 2(5) Maximum height from floor to be taken into account when calculating cubic space Fourteen feet 4.2 metres
Section 3(2) Minimum temperature of workroom after the first hour Sixty degrees 16 degrees Celsius
Section 18(1) Minimum height of edge of fixed vessel, structure, sump or pit containing scalding, corrosive or poisonous liquid which need not be covered or fenced Three feet 920 millimetres
Minimum height of secure fencing to surround the vessel, structure, sump or pit etc. Three feet 920 millimetres
Section 18(2)(a) Minimum width of ladder, stair or gangway placed above, across or inside any vessel, structure, sump etc. Eighteen inches 460 millimetres
Section 18(2)(b) Minimum height of fencing on either side of ladder, stair or gangway Three feet 920 millimetres
Section 18(3) Passage between adjoining vessels etc to be barred unless there is
(a) minimum space between vessels or Eighteen inches 460 millimetres
(b) minimum height of secure fencing Three feet 920 millimetres
Section 19(1) Minimum distance between traversing carriage of any self-acting spinning mule and any part of the head stock of another such machine Twelve inches 310 millimetres
Section 26(1)(f) Maximum thickness of chains or slings to be annealed every six months Half-inch 13 millimetres
Section 27(7) Minimum distance between over-head travelling crane and person working on or near its wheel track Twenty feet 6 metres
Section 29(2) Distance which person will be liable to fall Six feet six inches 2 metres
Section 30(2) Minimum length of manhole (if rectangular or oval) in any chamber, tank, vat etc. Eighteen inches 460 millimetres
Minimum width of manhole (if rectangular or oval) Sixteen inches 410 millimetres
Minimum diameter of manhole (if circular) Eighteen inches 460 millimetres
Minimum length of manhole (if rectangular or oval) in any tank wagon and other mobile plant Sixteen inches 410 millimetres
Minimum width of manhole (if rectangular or oval) Fourteen inches 360 millimetres
Minimum diameter of manhole (if circular) Sixteen inches 410 millimetres
Section 39(7) Storage capacity of water-sealed gasholder Five thousand cubic feet 140 cubic metres
Section 68(4) Wet bulb temperature reading above which artificial humidification is prohibited Seventy two and a half degrees 22.5 degrees Celsius
Wet bulb temperature reading above which artificial humidification is prohibited when spinning cotton or spinning merino or cashmere by the French or dry process or spinning or combing wool by that process Eighty degrees 26.5 degrees Celsius
Section 68(6) Temperature of water absorbing oxygen from permanganate of potash solution Sixty degrees 16 degrees Celsius
Ratio of water to oxygen absorbed Half a grain per gallon of water 7 milligrams per litre of water
Section 68(8) Minimum difference in readings of the wet and dry bulb thermometers Four degrees 2 degrees Celsius
Section 175(2)(n) Storage capacity of gasholder Five thousand cubic feet 140 cubic metres

SCHEDULE 2

FIRST SCHEDULE TABLE OF HUMIDITY Section 68 IIIDry Bulb TemperatureWet Bulb TemperatureDegrees CelsiusDegrees Celsius 109111012111312141315141615171618171918201921202220.5232124222522.52623.52724282529263026.5

SCHEDULE 3 — AMENDMENTS TO THE SCHEDULES TO ABSTRACT OF FACTORIES ACT ORDER 1973

(1) (2) (3) (4)
Provision to be amended Subject-matter of measurement Present measurement Measurement to be substituted
The Abstract of Factories Act Order 1973
Schedule 1
Paragraph 2 Minimum amount of cubic space per person employed in a workroom Four hundred cubic feet 11 cubic metres
Maximum height from floor to be taken into account when calculating cubic space Fourteen feet 4.2 metres
Paragraph 3 Minimum temperature of workroom after the first hour 60°F 16 degrees Celsius
Paragraph 17 Minimum height of edge of fixed vessel, structure, sump or pit containing scalding, corrosive or poisonous liquid which need not be covered or fenced Three feet 920 millimetres
Minimum width of ladder, stair or gangway placed above, across or inside any vessel, structure, sump etc. 18 inches 460 millimetres
Minimum height of secure fencing to ladder, stair or gangway Passage between vessels etc to be barred unless there is Three feet 920 millimetres
(a) minimum space between vessels or 18 inches 460 millimetres
(b) minimum height of secure fencing Three feet 920 millimetres
Paragraph 26 Minimum distance between over-head travelling crane and person working near its wheel track 20 feet 6 metres
Paragraph 28 Distance which person will be liable to fall Six feet six inches 2 metres
Schedule 2
Paragraph 13 Minimum distance between over-head travelling crane and person working near its wheel track 20 feet 6 metres

Signed

Signed by order of the Secretary of State.

John Selwyn Gummer — Joint Parliamentary Under Secretary of State — Department of Employment — 7th July 1983

Explanatory note

EXPLANATORY NOTE

These Regulations amend the Factories Act 1961 (“the 1961 Act”) by substituting amounts or quantities expressed in metric units for amounts or quantities not so expressed. The substituted amounts preserve the effect of the original provisions except to the extent necessary to obtain amounts expressed in suitable and convenient terms, save that, by Regulation 2, section 19(1) of the Act (which relates to self-acting machines) is amended to improve standards of safety.

Regulation 4 provides that the amendments do not relate to premises or plant in existence or under construction immediately before the coming into operation of these Regulations if those premises or that plant complied with the then existing requirements, except that the amendments to sections 3(2) and 68(4) and (8) of and the First Schedule to the 1961 Act (which relate to the temperature and humidity of certain workrooms) shall apply to those workrooms whether or not in existence or under construction immediately before the coming into operation of these Regulations.

The Abstract of Factories Act Order 1973 which prescribes the abstract of the 1961 Act which must be posted in factories is also amended by substituting metric for non-metric units.

Footnotes

[^f00001]: Section 15 was amended by the Employment Protection Act 1975 (c.71), section 116 and Schedule 15, paragraph 6 and section 49 by that section and paragraph 15 of that Schedule.

[^f00002]: The relevant amending instrument is S.I. 1974/1941.

Reading this document does not replace reading the official text published on legislation.gov.uk. Contains public sector information licensed under the Open Government Licence v3.0. We assume no responsibility for any inaccuracies arising from the conversion of the original CLML XML to this format.

This text is published under legislation.gov.uk's own terms of reuse, not a Legalize or public-domain licence. legislation.gov.uk
Open Government Licence v3.0 (attribution required)
© Crown and database right. Derived from content available under the Open Government Licence v3.0 from legislation.gov.uk.