The Smoke Control Areas (Exempted Fireplaces) (England) (No 2) Order 2010

Type Statutory-Instrument
Publication 2010-08-28
State In force
Department Queen's Printer of Acts of Parliament
PDF Download
articles Not indexed
Reform history JSON API

Made: 28th August 2010

Laid before Parliament: 6th September 2010

Coming into force: 1st October 2010

The Secretary of State is satisfied that the fireplaces exempted by this Order can be used for burning fuel other than authorised fuels2 without producing any smoke or a substantial quantity of smoke.

Citation, application and commencement

1

This Order—

Fireplaces exempted from the provisions of section 20 of the Clean Air Act 1993

2

The fireplaces listed in the Schedule are exempt from the provisions of section 20 of the Clean Air Act 1993 (prohibition on emission of smoke in smoke control area), subject to the conditions listed in the Schedule.

Revocation

3

The Smoke Control Areas (Exempted Fireplaces) (England) Order 20103 is revoked.

SCHEDULE — Exempted Fireplaces

Fireplace Conditions Conditions Conditions
The fireplace must be installed, maintained and operated in accordance with the following specifications: The fireplace must be installed, maintained and operated in accordance with the following specifications: Permitted fuels (other than authorised fuels).
(1) The fuel must not contain halogenated organic compounds or heavy metals as a result of treatment with wood-preservatives or coatings. (1) The fuel must not contain halogenated organic compounds or heavy metals as a result of treatment with wood-preservatives or coatings. (1) The fuel must not contain halogenated organic compounds or heavy metals as a result of treatment with wood-preservatives or coatings. (1) The fuel must not contain halogenated organic compounds or heavy metals as a result of treatment with wood-preservatives or coatings.
18i and 60i stoves manufactured by Jetmaster Fires Limited, Unit 2 Peacock Trading Estate, Goodwood Road, Eastleigh, Hampshire, SO50 4NT Installation and use instruction manual reference: “ Part No 106870 Issue No. 1” dated February 2010 and supplementary instruction manual reference: “Part No 106872 Issue No. 1” dated May 2010. The appliance will be fitted with a mechanical stop to prevent closure of the air control beyond the 40% open position when sold in smoke control areas. Installation and use instruction manual reference: “ Part No 106870 Issue No. 1” dated February 2010 and supplementary instruction manual reference: “Part No 106872 Issue No. 1” dated May 2010. The appliance will be fitted with a mechanical stop to prevent closure of the air control beyond the 40% open position when sold in smoke control areas. Wood logs[^f01000]
Aarrow Signature 5 SC, Aarrow Ecoburn 5 SC, Hamlet Solution 5 SC and Villager Espirit 5 SC Stoves manufactured by Arada Limited, The Fire Works, Millwey Industrial Estate, Axminster, Devon, EX13 5HU Instruction manual references “Rev 02” dated April 2010 All the appliances will be fitted with a mechanical stop to prevent closure of the air control beyond 20mm from the closed position and 50 mm beyond the fully open position. Instruction manual references “Rev 02” dated April 2010 All the appliances will be fitted with a mechanical stop to prevent closure of the air control beyond 20mm from the closed position and 50 mm beyond the fully open position. Wood logs[^f01000]
Arimax Bio 300Kw Arimax Bio 400Kw Arimax Bio 500Kw Boilers Manufactured by Artierm Oy PO Box 59 Fin – 43101 Saarijarvi, Finland Instruction manual references “ INSTALLATION AND OPERATION MANUAL Arimax Bio 120-3000 kW” dated 30/03/2010 Instruction manual references “ INSTALLATION AND OPERATION MANUAL Arimax Bio 120-3000 kW” dated 30/03/2010 6-8mm Wood Pellets with a Moisture content less than 10%[^f01000]
Barbas Unilux-3 40, 5 kW wood burning insert and Barbas ECO 40, 5 kW wood burning roomheater manufactured by Interfocos BV, Hallenstraat 17, NL-5531, AB, BLADEL, Netherlands The Unilux-3 40 Instruction Manual, document Version 01-326587 dated August 2009. The ECO 40 Instruction Manual, document Version 01-327332 dated October 2009. The Unilux-3 40 Instruction Manual, document Version 01-326587 dated August 2009. The ECO 40 Instruction Manual, document Version 01-327332 dated October 2009. Wood logs[^f01000]
The Binder Wood Fired Boiler models RRK 22-49 (49 kW output) manufactured by Binder Gesellschaft mit beschränkter Haftung (GmbH) of Austria The manufacturer’s and Wood Energy Limited’s instructions ‘Binder Equipment Installation, Commissioning and Maintenance’ dated 17th May 2005, reference WELBinderManualrev0.doc, revision 0 The manufacturer’s and Wood Energy Limited’s instructions ‘Binder Equipment Installation, Commissioning and Maintenance’ dated 17th May 2005, reference WELBinderManualrev0.doc, revision 0 Wood pellets or wood chips[^f01000]
The Binder Wood Fired Boiler models RRK 80-175 (75-149 kW output) with cyclone models ZA 80-175 manufactured by Binder Gesellschaft mit beschränkter Haftung (GmbH) of Austria The manufacturer’s and Wood Energy Limited’s instructions ‘Binder Equipment Installation, Commissioning and Maintenance’ dated 17th May 2005, reference WELBinderManualrev0.doc, revision 0 The manufacturer’s and Wood Energy Limited’s instructions ‘Binder Equipment Installation, Commissioning and Maintenance’ dated 17th May 2005, reference WELBinderManualrev0.doc, revision 0 Wood pellets or wood chips[^f01000]
The Binder Wood Fired Boiler model RRK 130-250 (185-230 kW output), RRK 200-350 (250-300 kW output), RRK 400-600 (350-500 kW output) and RRK 640-850 (650-840 kW output) with cyclone model type ZA manufactured by Binder Gesellschaft mit beschränkter Haftung (GmbH) of Austria The manufacturer’s and Wood Energy Limited’s instructions ‘Binder Equipment Installation, Commissioning and Maintenance’ dated 17th May 2005, reference WELBinderManualrev0.doc, revision 0 The manufacturer’s and Wood Energy Limited’s instructions ‘Binder Equipment Installation, Commissioning and Maintenance’ dated 17th May 2005, reference WELBinderManualrev0.doc, revision 0 Wood pellets or wood chips[^f01000]
The Binder Wood Fired Boiler model RRK 1000 (1200 kW output) with multi-cyclone model MZA manufactured by Binder Gesellschaft mit beschränkter Haftung (GmbH) of Austria The manufacturer’s and Wood Energy Limited’s instructions ‘Binder Equipment Installation, Commissioning and Maintenance’ dated 17th May 2005, reference WELBinderManualrev0.doc, revision 0 The manufacturer’s and Wood Energy Limited’s instructions ‘Binder Equipment Installation, Commissioning and Maintenance’ dated 17th May 2005, reference WELBinderManualrev0.doc, revision 0 Wood pellets or wood chips[^f01000]
The Binder Wood Fired Boiler model RRK 1200- 1650 with Binder model MZA multicyclone and automatic ignition manufactured by Binder Gesellschaft mit beschränkter Haftung (GmbH) of Austria Wood Energy Limited’s operating instructions for Binder appliances referenced: 2009 July Binder O&M revision8.doc Operation and Maintenance Manual, Revision 8, dated 15 July 2009 Wood Energy Limited’s operating instructions for Binder appliances referenced: 2009 July Binder O&M revision8.doc Operation and Maintenance Manual, Revision 8, dated 15 July 2009 Wood pellets or wood chips[^f01000]
The Binder Wood Fired Boiler model RRK 1800- 2300 Binder model MZA multicyclone and automatic ignition manufactured by Binder Gesellschaft mit beschränkter Haftung (GmbH) of Austria Wood Energy Limited’s operating instructions for Binder appliances referenced: 2009 July Binder O&M revision8.doc Operation and Maintenance Manual, Revision 8, dated 15 July 2009 Wood Energy Limited’s operating instructions for Binder appliances referenced: 2009 July Binder O&M revision8.doc Operation and Maintenance Manual, Revision 8, dated 15 July 2009 Wood pellets or wood chips⁽¹⁾
The Binder Wood Fired Boiler model RRK 2500- 3000 with Binder model MZA multicyclone and automatic ignition manufactured by Binder Gesellschaft mit beschränkter Haftung (GmbH) of Austria Wood Energy Limited’s operating instructions for Binder appliances referenced: 2009 July Binder O&M revision8.doc Operation and Maintenance Manual, Revision 8, dated 15 July 2009 Wood Energy Limited’s operating instructions for Binder appliances referenced: 2009 July Binder O&M revision8.doc Operation and Maintenance Manual, Revision 8, dated 15 July 2009 Wood pellets or wood chips⁽¹⁾
Biomatic 220 and 250 fitted with Zyklovent 220–250 cyclone separator manufactured by HERZ Armaturen Ges.m.b.H, Geschäftsbereich HERZ, Feuerungstechnik, A–8272 Sebersdorf 138, Austria The manufacturer’s instructions dated April 2005, reference Bedienungsanleitung Englisch v2.0 doc The manufacturer’s instructions dated April 2005, reference Bedienungsanleitung Englisch v2.0 doc Chipped wood, wood pellets or planed wood shavings[^f01000]
Biomatic 300, 350, 400 and 500 fitted with Zyklovent 300-500 cyclone separator manufactured by HERZ Armaturen Ges.m.b.H, Geschäftsbereich HERZ, Feuerungstechnik, A-8272 Sebersdorf 138, Austria The manufacturer’s instructions dated April 2005, reference Bedienungsanleitung Englisch v2.0 doc The manufacturer’s instructions dated April 2005, reference Bedienungsanleitung Englisch v2.0 doc Chipped wood, wood pellets or planed wood shavings[^f01000]
Carron Stove manufactured by Jig UK Limited Hurlingham Business Park, Fulbeck Heath, Grantham, Lincolnshire NG32 3HL Instruction manual references “91- 62351” dated July 2009 Instruction manual references “91- 62351” dated July 2009 Dry and split wood logs of a maximum length of 23 cm⁽¹⁾
Charnwood Cove 1SR stove manufactured by A.J Wells and Sons Ltd, Bishops Way, Newport, Isle of Wight, PO30 5WS Installation and Use Instruction manual references “COVE1SR01.10 Issue A” An adjustment of the air control such that the minimum closure of the air control is equivalent to that found with the control pushed in 15mm from the fully open position Installation and Use Instruction manual references “COVE1SR01.10 Issue A” An adjustment of the air control such that the minimum closure of the air control is equivalent to that found with the control pushed in 15mm from the fully open position Wood logs[^f01000]
Charnwood Tor stove manufactured by A.J Wells and Sons Ltd, Bishops Way, Newport, Isle of Wight, PO30 5WS Installation and Use Instruction manual references “Tor 02.10 Issue A” Installation and Use Instruction manual references “Tor 02.10 Issue A” Wood logs[^f01000]
Chesneys 4 Series (4.6 kW) Stoves: Flatford 4, Hampstead 4, Alpine 4 also sold as: Sunbeam 4, Dakota 4, Providence 4. Pacific 4 also sold as: Milan 4, Murano 4, Apollo 4. Chelsea 4 also sold as: Wellington 4, Guernsey 4, Belgravia 4 Manufactured by Chesneys,194-200 Battersea Park Road, London, SW11 4ND Chesneys 4 series Instruction manual references “CH4K-V4” dated 7th December 2009 The appliance must be fitted with a mechanical stop to prevent closure of the air control beyond the 34mm open position Chesneys 4 series Instruction manual references “CH4K-V4” dated 7th December 2009 The appliance must be fitted with a mechanical stop to prevent closure of the air control beyond the 34mm open position Wood logs⁽¹⁾
Chesneys 6 Series (7 kW) Stoves: Flatford 6, Barrington 6, Petworth 6, Hampstead 6, Alpine 6 also sold as: Sunbeam 6, Dakota 6, Providence 6 and the Chelsea 6 also sold as: Wellington 6, Guernsey 6, Belgravia 6 Manufactured by Chesneys, 194-200 Battersea Park Road, London, SW11 4ND Chesneys 6 series Instruction manual references “CH6K-V4” dated 7th December 2009 The appliance must be fitted with a mechanical stop to prevent closure of the air control beyond the 10mm open position Chesneys 6 series Instruction manual references “CH6K-V4” dated 7th December 2009 The appliance must be fitted with a mechanical stop to prevent closure of the air control beyond the 10mm open position Wood logs⁽¹⁾
The Classic model 25, 35, 40, 49, and 60 wood pellet boilers manufactured by Hargassner Gesellschaft mit beschränkter Haftung (GmbH), Gunderding 8, A-4952, Weng, Austria The manufacturer’s installation manual for the Classic Pellet Boilers reference No. 22, Pellet Boilers, Type Classic 25, 31, 35, 40, 49, 60, reference BA Classic 25L-60L Nr 21 0508. The manufacturer’s installation manual for the Classic Pellet Boilers reference No. 22, Pellet Boilers, Type Classic 25, 31, 35, 40, 49, 60, reference BA Classic 25L-60L Nr 21 0508. Wood pellets⁽¹⁾.
The Clearview Pioneer 400, Solution 400 and Pioneer Oven wood burning stoves manufactured by Clearview Stoves of More Works, Bishops Castle, Shropshire, SY9 5HH The manufacturer’s instructions ‘Operating Instructions Clearview Vision/Vision Inset/Pioneer & Solution’ dated 1st July 2006, reference V1/42, stamped and signed “Smoke Control” The appliance must be fitted with a tamperproof mechanical stop on the air slide/damper. The manufacturer’s instructions ‘Operating Instructions Clearview Vision/Vision Inset/Pioneer & Solution’ dated 1st July 2006, reference V1/42, stamped and signed “Smoke Control” The appliance must be fitted with a tamperproof mechanical stop on the air slide/damper. Air-dried wood logs[^f01000]
Contura 510, Contura 520T, Contura 550, Contura 550A, Contura 550W, Contura 560T, Contura 560K, Contura 570, Contura 580, Contura 585, Contura 590, Contura T, all manufactured by NIBE AB Box 134, 285 23 Markaryd, Sweden Installation Instruction IAV SE/EX 0726-6 611821 Lighting instruction BAV SE/EX 0717-2 611820 A permanent stop must be in place on the air inlet to prevent closure beyond the 20% open position. Installation Instruction IAV SE/EX 0726-6 611821 Lighting instruction BAV SE/EX 0717-2 611820 A permanent stop must be in place on the air inlet to prevent closure beyond the 20% open position. Untreated dry wood with less than 20% moisture⁽¹⁾
Contura 580W manufactured by NIBE AB Box 134, 285 23 Markaryd, Sweden Installation instruction IAV SE/EX 0740-1 511911 A permanent stop must be in place on the air inlet to prevent closure beyond the 20% open position. Installation instruction IAV SE/EX 0740-1 511911 A permanent stop must be in place on the air inlet to prevent closure beyond the 20% open position. Untreated dry wood with less than 20% moisture⁽¹⁾
Cove 2 SR manufactured by A.J.Wells & Sons Ltd of Bishops Way, Newport, Isle of Wight, PO30 5WS Instruction manual references “Cove2SR 07.09 IssB” dated July 2009 A permanent stop must be in place on air control to prevent closure beyond 14mm from the fully closed position Instruction manual references “Cove2SR 07.09 IssB” dated July 2009 A permanent stop must be in place on air control to prevent closure beyond 14mm from the fully closed position Dry and split wood logs of a maximum length of 23 cm⁽¹⁾
CTC Ecoflex 15 and 20 manufactured by Enertech AB, Box 313, S-341 26 Ljungby, Sweden The manufacturer’s instructions dated 20th February 2007, reference 161 505 27 06/1 The manufacturer’s instructions dated 20th February 2007, reference 161 505 27 06/1 Wood pellets[^f01000]
Dimplex SE Selborne 5 stove manufactured by ESSE Engineering Ltd, Ouzledale Foundry Long Ing Barnoldswick Lancashire BB18 6BN Instruction manual references “SE Selborne 5 Issue 1” dated 08 2009 All appliances will be fitted with a mechanical stop to prevent closure beyond the 50% open position when sold into smoke control areas. Instruction manual references “SE Selborne 5 Issue 1” dated 08 2009 All appliances will be fitted with a mechanical stop to prevent closure beyond the 50% open position when sold into smoke control areas. Wood logs[^f01000]
Dovre 250 (model DV-250) manufactured by Dovre NV, Nijverheidsstraat 18, BE-2381 Weelde, Belgium The manufacturer’s instructions, reference PM 250 Issue 1 The manufacturer’s instructions, reference PM 250 Issue 1 Untreated dry wood[^f01000]
Dovre 250 (model DV-250) manufactured by Dovre NV, Nijverheidsstraat 18, BE-2381 Weelde, Belgium A permanent stop must be in place on the secondary air inlet to prevent closure beyond the 75% open position A permanent stop must be in place on the secondary air inlet to prevent closure beyond the 75% open position Untreated dry wood[^f01000]
The Dunsley Yorkshire Stove, manufactured by Dunsley Heat Limited The manufacturer’s instructions dated 5th August 1998, reference A/22160 as amended by those dated 4th December 2004, reference D13 The manufacturer’s instructions dated 5th August 1998, reference A/22160 as amended by those dated 4th December 2004, reference D13 Untreated dry wood[^f01000]
The Dunsley Yorkshire Stove, manufactured by Dunsley Heat Limited The manufacturer’s instructions dated 5th August 1998, reference A/22160 as amended by those dated 4th December 2004, reference D13 The manufacturer’s instructions dated 5th August 1998, reference A/22160 as amended by those dated 4th December 2004, reference D13
The Dunsley Yorkshire Stove, manufactured by Dunsley Heat Limited The manufacturer’s instructions dated 5th August 1998, reference A/22160 as amended by those dated 4th December 2004, reference D13 The manufacturer’s instructions dated 5th August 1998, reference A/22160 as amended by those dated 4th December 2004, reference D13 Peat or peat briquettes with, in either case, less than 25% moisture
The Dunsley Yorkshire Stove, manufactured by Dunsley Heat Limited The manufacturer’s instructions dated 5th August 1998, reference A/22160 as amended by those dated 4th December 2004, reference D13 The manufacturer’s instructions dated 5th August 1998, reference A/22160 as amended by those dated 4th December 2004, reference D13
The Dunsley Yorkshire Stove, manufactured by Dunsley Heat Limited The manufacturer’s instructions dated 5th August 1998, reference A/22160 as amended by those dated 4th December 2004, reference D13 The manufacturer’s instructions dated 5th August 1998, reference A/22160 as amended by those dated 4th December 2004, reference D13 Union Coal Briketts, manufactured by Rheinbraun AG of Germany comprising lignite compressed into briquettes of approximately 15 cm in length with square ends and with a sulphur content not exceeding 1% of the total weight
The Dunsley Yorkshire Stove, manufactured by Dunsley Heat Limited The manufacturer’s instructions dated 5th August 1998, reference A/22160 as amended by those dated 4th December 2004, reference D13 The manufacturer’s instructions dated 5th August 1998, reference A/22160 as amended by those dated 4th December 2004, reference D13
The Dunsley Yorkshire Stove, manufactured by Dunsley Heat Limited The manufacturer’s instructions dated 5th August 1998, reference A/22160 as amended by those dated 4th December 2004, reference D13 The manufacturer’s instructions dated 5th August 1998, reference A/22160 as amended by those dated 4th December 2004, reference D13 CPL Wildfire, manufactured by Coal Products Limited, Immingham, which— comprise bituminous coal with a volatile content of 32-36% (as to approximately 96% of the total weight) and a cold cure resin binder (as to the remaining weight); are manufactured from those constituents by a process involving roll-pressing; have an average weight of either 80-90 grams or 160-170 grams; and have a sulphur content not exceeding 1.8% of the total weight
The Dunsley Yorkshire Multifuel Stove manufactured by Dunsley Heat Limited The manufacturer’s instructions dated 5th August 1998, reference A/22160 as amended by those dated 4th December 2004, reference D13 The manufacturer’s instructions dated 5th August 1998, reference A/22160 as amended by those dated 4th December 2004, reference D13 Untreated dry wood[^f01000]
The Dunsley Yorkshire Multifuel Stove manufactured by Dunsley Heat Limited The manufacturer’s instructions dated 5th August 1998, reference A/22160 as amended by those dated 4th December 2004, reference D13 The manufacturer’s instructions dated 5th August 1998, reference A/22160 as amended by those dated 4th December 2004, reference D13
The Dunsley Yorkshire Multifuel Stove manufactured by Dunsley Heat Limited The manufacturer’s instructions dated 5th August 1998, reference A/22160 as amended by those dated 4th December 2004, reference D13 The manufacturer’s instructions dated 5th August 1998, reference A/22160 as amended by those dated 4th December 2004, reference D13 Peat or peat briquettes with, in either case, less than 25% moisture
The Dunsley Yorkshire Multifuel Stove manufactured by Dunsley Heat Limited The manufacturer’s instructions dated 5th August 1998, reference A/22160 as amended by those dated 4th December 2004, reference D13 The manufacturer’s instructions dated 5th August 1998, reference A/22160 as amended by those dated 4th December 2004, reference D13
The Dunsley Yorkshire Multifuel Stove manufactured by Dunsley Heat Limited The manufacturer’s instructions dated 5th August 1998, reference A/22160 as amended by those dated 4th December 2004, reference D13 The manufacturer’s instructions dated 5th August 1998, reference A/22160 as amended by those dated 4th December 2004, reference D13 Union Coal Briketts, manufactured by Rheinbraun AG of Germany comprising lignite compressed into briquettes of approximately 15 cm in length with square ends and with a sulphur content not exceeding 1% of the total weight
The Dunsley Yorkshire Multifuel Stove manufactured by Dunsley Heat Limited The manufacturer’s instructions dated 5th August 1998, reference A/22160 as amended by those dated 4th December 2004, reference D13 The manufacturer’s instructions dated 5th August 1998, reference A/22160 as amended by those dated 4th December 2004, reference D13
The Dunsley Yorkshire Multifuel Stove manufactured by Dunsley Heat Limited The manufacturer’s instructions dated 5th August 1998, reference A/22160 as amended by those dated 4th December 2004, reference D13 The manufacturer’s instructions dated 5th August 1998, reference A/22160 as amended by those dated 4th December 2004, reference D13 CPL Wildfire, manufactured by Coal Products Limited, Immingham, which—comprise bituminous coal with a volatile content of 32-36% (as to approximately 96% of the total weight) and a cold cure resin binder (as to the remaining weight); are manufactured from those constituents by a process involving roll-pressing; have an average weight of either 80-90 grams or 160-170 grams; and have a sulphur content not exceeding 1.8% of the total weight
The Dunsley Yorkshire Multifuel Stove and Boiler manufactured by Dunsley Heat Limited The manufacturer’s instructions dated 5th August 1998, reference A/22160, as amended by those dated 4th October 2004, reference GHD/DUN4B/1 The manufacturer’s instructions dated 5th August 1998, reference A/22160, as amended by those dated 4th October 2004, reference GHD/DUN4B/1 Untreated dry wood[^f01000]
The Dunsley Yorkshire Multifuel Stove and Boiler manufactured by Dunsley Heat Limited The manufacturer’s instructions dated 5th August 1998, reference A/22160, as amended by those dated 4th October 2004, reference GHD/DUN4B/1 The manufacturer’s instructions dated 5th August 1998, reference A/22160, as amended by those dated 4th October 2004, reference GHD/DUN4B/1
The Dunsley Yorkshire Multifuel Stove and Boiler manufactured by Dunsley Heat Limited The manufacturer’s instructions dated 5th August 1998, reference A/22160, as amended by those dated 4th October 2004, reference GHD/DUN4B/1 The manufacturer’s instructions dated 5th August 1998, reference A/22160, as amended by those dated 4th October 2004, reference GHD/DUN4B/1 Peat or peat briquettes with, in either case, less than 25% moisture
The Dunsley Yorkshire Multifuel Stove and Boiler manufactured by Dunsley Heat Limited The manufacturer’s instructions dated 5th August 1998, reference A/22160, as amended by those dated 4th October 2004, reference GHD/DUN4B/1 The manufacturer’s instructions dated 5th August 1998, reference A/22160, as amended by those dated 4th October 2004, reference GHD/DUN4B/1
The Dunsley Yorkshire Multifuel Stove and Boiler manufactured by Dunsley Heat Limited The manufacturer’s instructions dated 5th August 1998, reference A/22160, as amended by those dated 4th October 2004, reference GHD/DUN4B/1 The manufacturer’s instructions dated 5th August 1998, reference A/22160, as amended by those dated 4th October 2004, reference GHD/DUN4B/1 Union Coal Briketts, manufactured by Rheinbraun AG of Germany and comprising lignite compressed into briquettes of approximately 15 cm in length with square ends and with a sulphur content not exceeding 1% of the total weight
The Dunsley Yorkshire Multifuel Stove and Boiler manufactured by Dunsley Heat Limited The manufacturer’s instructions dated 5th August 1998, reference A/22160, as amended by those dated 4th October 2004, reference GHD/DUN4B/1 The manufacturer’s instructions dated 5th August 1998, reference A/22160, as amended by those dated 4th October 2004, reference GHD/DUN4B/1
The Dunsley Yorkshire Multifuel Stove and Boiler manufactured by Dunsley Heat Limited The manufacturer’s instructions dated 5th August 1998, reference A/22160, as amended by those dated 4th October 2004, reference GHD/DUN4B/1 The manufacturer’s instructions dated 5th August 1998, reference A/22160, as amended by those dated 4th October 2004, reference GHD/DUN4B/1 CPL Wildfire, manufactured by Coal Products Limited, Immingham, which comprise bituminous coal with a volatile content of 32-36% (as to approximately 96% of the total weight) and a cold cure resin binder (as to the remaining weight); are manufactured from those constituents by a process involving roll-pressing; have an average weight of between 80-90 grams or between 160-170 grams; and have a sulphur content not exceeding 1.8% of the total weight
The Dunsley Yorkshire Woodburning Stove manufactured by Dunsley Heat Limited The manufacturer’s instructions dated 4th December 2004, reference D13W The manufacturer’s instructions dated 4th December 2004, reference D13W Untreated dry wood[^f01000]
The Dunsley Yorkshire Woodburning Stove and Boiler manufactured by Dunsley Heat Limited The manufacturer’s instructions dated 4th December 2004, reference D13W together with the manufacturer’s instructions dated 4th October 2004 reference GHD/DUN4B/1 The manufacturer’s instructions dated 4th December 2004, reference D13W together with the manufacturer’s instructions dated 4th October 2004 reference GHD/DUN4B/1 Untreated dry wood[^f01000]
Earlswood manufactured by ACR Heat Products Limited, Unit One Weston Works, Weston Lane, Tyseley, Birmingham B11 3RP Instruction manual reference “EW1MF technical manual” dated 02 2009. When the primary air control is in the closed position, it remains permanently open by 5mm and is prevented from closing fully by a screw. Instruction manual reference “EW1MF technical manual” dated 02 2009. When the primary air control is in the closed position, it remains permanently open by 5mm and is prevented from closing fully by a screw. Wood logs⁽¹⁾
Eccostove manufactured by Landy Vent Foster House 2 Redditch Road Studley Warwickshire B80 7AX Instruction manual references “02/10” dated 10/02/2010. The fitting of a system that prevents the closure of the secondary air flaps to be less than 4mm (3 Turns) open position should be implemented. Instruction manual references “02/10” dated 10/02/2010. The fitting of a system that prevents the closure of the secondary air flaps to be less than 4mm (3 Turns) open position should be implemented. Wood logs[^f01000]
The En-tech model ENP 10, 15, 18, 25 and 35 boilers manufactured by En-tech Energietechnikproduktion Gesellschaft mit beschränkter Haftung (GmbH), Gewerbezone 3, A-9300 St Veit, Glan-Hunnenbrunn, Austria The manufacturer’s installation manual dated 11/2009, reference IMENP 10-35 11/2009 for the Firefox pellet boiler. The manufacturer’s installation manual dated 11/2009, reference IMENP 10-35 11/2009 for the Firefox pellet boiler. Wood pellets⁽¹⁾.
The En-tech model PK 15 and 25 boilers manufactured by En-tech Energietechnikproduktion Gesellschaft mit beschränkter Haftung (GmbH), Gewerbezone 3, A-9300 St Veit, Glan-Hunnenbrunn, Austria The manufacturer’s installation manual dated 11/2009, reference IMPK PK15/25 11/2009 EN for the Firefox pellet boiler. The manufacturer’s installation manual dated 11/2009, reference IMPK PK15/25 11/2009 EN for the Firefox pellet boiler. Wood pellets⁽¹⁾
The En-tech model PK 45 boilers manufactured by En-tech Energietechnikproduktion Gesellschaft mit beschränkter Haftung (GmbH), Gewerbezone 3, A-9300 St Veit, Glan-Hunnenbrunn, Austria The manufacturer’s installation manual dated 11/2009, reference IMPK PK45 11/2009 EN for the Firefox pellet boiler. The manufacturer’s installation manual dated 11/2009, reference IMPK PK45 11/2009 EN for the Firefox pellet boiler. Wood pellets⁽¹⁾
100SE Smoke Exempt Woodburning Stove manufactured by ESSE Engineering Limited, Long Ing Barnoldswick Lancashire, BB18 6BN The manufacturer’s instruction manual dated February 2009, reference 100SE Issue 1 A permanent stop must be in place on the secondary air inlet to prevent closure beyond the 50% open position The manufacturer’s instruction manual dated February 2009, reference 100SE Issue 1 A permanent stop must be in place on the secondary air inlet to prevent closure beyond the 50% open position Untreated dry wood with a maximum moisture content of 20%, maximum length of 200 mm and maximum width or diameter of 120 mm[^f01000]
Esse 125 SE stove manufactured by ESSE Engineering Ltd, Ouzledale Foundry, Long Ing, Barnoldswick, Lancashire, BB18 6BN Instruction manual references “Esse125SE Issue 1” dated 08 2009 All appliances will be fitted with a mechanical stop to prevent closure beyond the 50% open position when sold into smoke control areas. Instruction manual references “Esse125SE Issue 1” dated 08 2009 All appliances will be fitted with a mechanical stop to prevent closure beyond the 50% open position when sold into smoke control areas. Wood logs[^f01000]
Esse 1622 inset stove manufactured by Esse Engineering Limited, Long Ing, Barnoldswick Lancashire BB18 6BN Installation and operation manual reference “1622/Integra INSET revision c ” dated July 2010 All appliances used in smoke control areas must be fitted with a mechanical stop to fix secondary air control fully open. Installation and operation manual reference “1622/Integra INSET revision c ” dated July 2010 All appliances used in smoke control areas must be fitted with a mechanical stop to fix secondary air control fully open. Wood logs[^f01000]
Evotherm P50, P100, P120, P150, P170, P200 pellet boilers manufactured by Evotherm, Heiztechnik Vertriebs Gesellschaft mit beschrankter Haftung (GmbH), Seeleiten 24, AT 5120, St Pantaleon, Austria The manufacturer’s instructions ‘Operating manual’ reference Version 1/2010/Rev 4.21. The manufacturer’s instructions ‘Operating manual’ reference Version 1/2010/Rev 4.21. Wood pellets[^f01000]
The Extraflame: Babyfiamma, Bella and Bella Lux, Clementina, Comfort Maxi, Contessa, Divina, Divina Plus and Divina Steel, Duchessa and Duchessa Steel, Ecologica, Esmeralda and Esmeralda Crystal, Falò 1CP, Falò 2CP and Falò 1XP, Isabella, Karolina and Preziosa, all of which are manufactured by Extraflame S.p.a in Montecchio Precalcino (Vicenza), Italy The manufacturer’s operating instructions dated 5th March 2007, reference 004275101 011 The manufacturer’s operating instructions dated 5th March 2007, reference 004275101 011 Wood pellets[^f01000]
The Extraflame Comfort Mini manufactured by Extraflame S.p.a in Montecchio Precalcino (Vicenza), Italy The manufacturer’s operating instructions dated 2nd October 2006, reference 004275115 REV 005 The manufacturer’s operating instructions dated 2nd October 2006, reference 004275115 REV 005 Wood pellets[^f01000]
The Extraflame Idro manufactured by Extraflame S.p.a in Montecchio Precalcino (Vicenza), Italy The manufacturer’s operating instructions dated 28th August 2006, reference 004275128 REV 002 The manufacturer’s operating instructions dated 28th August 2006, reference 004275128 REV 002 Wood pellets[^f01000]
The Extraflame Lucrezia Idro and Lucrezia Steel manufactured by Extraflame S.p.a in Montecchio Precalcino (Vicenza), Italy The manufacturer’s operating instructions dated 12th July 2006, reference 004275110 REV 011 The manufacturer’s operating instructions dated 12th July 2006, reference 004275110 REV 011 Wood pellets[^f01000]
Firefox 5CB, Vega 100CB, Sirius 405CB and Flame 5CB (4.9kW) stoves manufactured by Percy Doughty & Co, Imperial Point, Express Trading Estate, Stonehill Road, Farnworth, Bolton, BL4 9TN Instruction manual references “FFXCBA” dated January 2010 Instruction manual references “FFXCBA” dated January 2010 Wood logs[^f01000]
Fireline FP5, Fireline FX5, Fireline FPi 5kW and Fireline FXi 5kW manufactured by Charlton and Jenrick, Ltd Charlton and Jenrick G1-G2, Halesfield 5, Telford, Shropshire, TF7 4QJ Instruction manual references “Issue 03” dated 03/10 The fitting of a system that prevents the closure of the secondary air control beyond the 3.5mm open position should be implemented. Instruction manual references “Issue 03” dated 03/10 The fitting of a system that prevents the closure of the secondary air control beyond the 3.5mm open position should be implemented. Wood logs⁽¹⁾
Firematic 25, 50, 90 and 150 manufactured by HERZ Armaturen Ges.m.b.H, Geschäftsbereich HERZ, Feuerungstechnik, A-8272 Sebersdorf 138, Austria The manufacturer’s instructions dated June 2005, reference Bedienungsanleitung Firematic V 1.1 ENG doc The manufacturer’s instructions dated June 2005, reference Bedienungsanleitung Firematic V 1.1 ENG doc Chipped wood, wood pellets or planed wood shavings[^f01000]
Firematic 45 and 60 manufactured by HERZ Armaturen Ges.m.b.H, Geschäftsbereich HERZ Feuerungstechnik, A-8272 Sebersdorf 138, Austria Instruction manual references “05.007 .Operating instructions - FM (1Ph) 20 35 45 60 v2.3” dated “08/2009” Instruction manual references “05.007 .Operating instructions - FM (1Ph) 20 35 45 60 v2.3” dated “08/2009” Wood pellets conforming to ÖNORM M7135 with diameter of 6 mm or Wood chips up to a maximum size of 50mm and maximum water content 35%⁽¹⁾
Franco Belge Model 134 08 11 Savoy EA 8kW output wood burning stove manufactured by : Franco Belge, Staub Fonderie SARL, Rue Orphée Variscotte, 59660, Merville, France The Savoy EA Technical Manual, document reference 1290-1, reviewed 9 July 2009. The Savoy EA Technical Manual, document reference 1290-1, reviewed 9 July 2009. Wood logs⁽¹⁾
Fröling Lambdamat Commercial wood chip boiler models 500, 750 and 1000 manufactured by Fröling Heizkessel und Behälterbau Gesellschaft mit beschränkter Haftung (GmbH), A-4710 Grieskirchen, Industriestrasse 12, Austria Lambdamat Communal Operating and Installation Manual reference B 069 01 04 of February 2004 Lambdamat Communal Operating and Installation Manual reference B 069 01 04 of February 2004 Wood chips⁽¹⁾
Fröling Turbomatic 28, 35, 48 and 55 manufactured by Fröling Heizkessel- und Behälterbau Ges.m.b.H, Industriestraße 12, A-4710 Grieskirchen, Austria The manufacturer’s installation manual dated November 2003, reference M 060 01 03 The manufacturer’s installation manual dated November 2003, reference M 060 01 03 Wood chip less than 35% moisture content and meeting ÖNORM M 7133: 1998 size class G30[^f01000]
Fröling Turbomatic 28, 35, 48 and 55 manufactured by Fröling Heizkessel- und Behälterbau Ges.m.b.H, Industriestraße 12, A-4710 Grieskirchen, Austria The manufacturer’s operating manual dated August 2002, reference 99229a The manufacturer’s operating manual dated August 2002, reference 99229a Wood pellets of 6 mm diameter and a moisture content below 10%[^f01000]
Fröling Turbomatic 85, 100 and 110 manufactured by Fröling Heizkessel- und Behälterbau Ges.m.b.H, Industriestraße 12, A-4710 Grieskirchen, Austria The manufacturer’s instruction manual dated November 2003, reference M 060 01 03 The manufacturer’s instruction manual dated November 2003, reference M 060 01 03 Wood chip less than 35% moisture content and meeting ÖNORM M 7133: 1998 of either size class G30 or G50[^f01000]
Fröling Turbomatic 85, 100 and 110 manufactured by Fröling Heizkessel- und Behälterbau Ges.m.b.H, Industriestraße 12, A-4710 Grieskirchen, Austria The manufacturer’s operating manual dated August 2002, reference 99229a The manufacturer’s operating manual dated August 2002, reference 99229a Wood pellets of 6 mm diameter and a moisture content below 10%[^f01000]
Fröling Turbomat 150 and 220 manufactured by Fröling Heizkessel- und Behälterbau Ges.m.b.H, Industriestraße 12, A-4710 Grieskirchen, Austria The manufacturer’s operating instructions dated August 2003, reference B0310003 The manufacturer’s operating instructions dated August 2003, reference B0310003 Wood pellets or wood chips[^f01000]
Fröling Turbomat 320 and 500 manufactured by Fröling Heizkessel- und Behälterbau Ges.m.b.H, Industriestraße 12, A-4710 Grieskirchen, Austria The manufacturer’s operating instructions dated November 2004, reference B0340004 The manufacturer’s operating instructions dated November 2004, reference B0340004 Wood pellets or wood chips[^f01000]
Fröling P4 8, 15, 20, 25, 32, 38, 48 and 60 Pellet Boilers manufactured by Fröling Heizkessel- und Behälterbau Ges.m.b.H, Industriestrasse 12, A-4710 Grieskirchen Instruction manual reference “B0430408_en” dated July 2009 Instruction manual reference “B0430408_en” dated July 2009 Wood pellets with a diameter of 6mm⁽¹⁾
Gilles HPK-RA 13 kW, 15 kW, 20 kW, 25 kW, 30 kW, 35 kW, 40 kW, 45 kW, 49 kW, 60 kW, 70 kW, 75 kW, 85 kW, 95 kW, 100 kW, 120 kW and 145 kW manufactured by GILLES Energie- und Umwelttechnik GmbH, Koaserbauer Str. 16 A-4810 Gmunden, Austria Operating instructions dated January 2007, reference Gilles/0–145/1 Operating instructions dated January 2007, reference Gilles/0–145/1 Wood pellets or wood chips[^f01000]
Gilles HPK USK 150 kW, 180 kW, 240 kW and 300 kW manufactured by GILLES Energie- und Umwelttechnik GmbH, Koaserbauer Str. 16 A-4810 Gmunden, Austria Operating instructions dated January 2007, reference Gilles/150–300/1 Operating instructions dated January 2007, reference Gilles/150–300/1 Wood pellets or wood chips[^f01000]
Gilles HPK USK 360 kW manufactured by GILLES Energie- und Umwelttechnik GmbH, Koaserbauer Str. 16 A-4810 Gmunden, Austria Operating instructions dated January 2008, reference Gilles/360/1 Operating instructions dated January 2008, reference Gilles/360/1 Wood pellets or wood chips[^f01000]
Gilles UTSK 450 kW, 550 kW boilers manufactured by GILLES Energie- und Umwelttechnik GmbH, Koaserbauer Str. 16 A-4810 Gmunden, Austria Operating instructions dated January 2008, reference Gilles/360/1 Operating instructions dated January 2008, reference Gilles/360/1 Wood pellets or wood chips[^f01000]
Gilles UTSK 700 kW, 900 kW boilers manufactured by GILLES Energie- und Umwelttechnik GmbH, Koaserbauer Str. 16 A-4810 Gmunden, Austria Operating instructions dated January 2008, reference Gilles/360/1 Operating instructions dated January 2008, reference Gilles/360/1 Wood pellets or wood chips⁽¹⁾
Gilles UTSK 1200 kW, 1600 kW boilers manufactured by GILLES Energie- und Umwelttechnik GmbH, Koaserbauer Str. 16 A-4810 Gmunden, Austria Operating instructions dated January 2008, reference Gilles/360/1 Operating instructions dated January 2008, reference Gilles/360/1 Wood pellets or wood chips[^f01000]
Guntamatic Biocom and Powercorn 50 and 75 manufactured by GUNTAMATIC Heiztechnik GmbH A – 4722 PEUERBACH, Bruck 7 Instruction manual references “GUN/BIO/OP/V1/0709” dated 29/07/09 Instruction manual references “GUN/BIO/OP/V1/0709” dated 29/07/09 Wood pellets with a diameter of 6mm and a length of between 10 and 30 mm⁽¹⁾
Guntamatic Powerchip 50 and 75 manufactured by GUNTAMATIC Heiztechnik GmbH A – 4722 PEUERBACH, Bruck 7 Instruction manual references “GUN/POW/OP/V1/0709” dated 29/07/09 Instruction manual references “GUN/POW/OP/V1/0709” dated 29/07/09 Wood pellets with a diameter of 6mm and a length of between 10 and 30 mm⁽¹⁾
Guntamatic Biocom and Powercorn 100 manufactured by GUNTAMATIC Heiztechnik GmbH A – 4722 PEUERBACH, Bruck 7 Instruction manual references “GUN/BIO/OP/V1/0709” dated 29/07/09. Instruction manual references “GUN/BIO/OP/V1/0709” dated 29/07/09. Wood pellets with a diameter of 6 mm and a length of between 10 and 30 mm or Wood chip less than 35% moisture content and meeting ÖNORM M 7133: 1998 size class G30⁽¹⁾
Guntamatic Powerchip 100 manufactured by GUNTAMATIC Heiztechnik GmbH A – 4722 PEUERBACH, Bruck 7 Instruction manual references “GUN/POW/OP/V1/0709” dated 29/07/09 Instruction manual references “GUN/POW/OP/V1/0709” dated 29/07/09 Wood pellets with a diameter of 6 mm and a length of between 10 and 30 mm or Wood chip less than 35% moisture content and meeting ÖNORM M 7133: 1998 size class G30 ⁽¹⁾
The HSV 50 + WTH 45, 49 or 55 boilers manufactured by Hargassner Gesellschaft mit beschränkter Haftung (GmbH), Gunderding 8, A-4952, Weng, Austria The manufacturer’s installation manual version 44 for Wood Chip and Pellet Stoves, Type HSV 30-100. Reference BA HSV30-100 RA/RAP V44 0608. The manufacturer’s installation manual version 44 for Wood Chip and Pellet Stoves, Type HSV 30-100. Reference BA HSV30-100 RA/RAP V44 0608. Wood chip or wood pellets⁽¹⁾
The HSV 80 + WTH 70 or 80 boilers manufactured by Hargassner Gesellschaft mit beschränkter Haftung (GmbH), Gunderding 8, A-4952, Weng, Austria The manufacturer’s installation manual version 44 for Wood Chip and Pellet Stoves, Type HSV 30-100. Reference BA HSV30-100 RA/RAP V44 0608. The manufacturer’s installation manual version 44 for Wood Chip and Pellet Stoves, Type HSV 30-100. Reference BA HSV30-100 RA/RAP V44 0608. Wood chip or wood pellets⁽¹⁾
The HSV 100 + WTH 100 boiler manufactured by Hargassner Gesellschaft mit beschränkter Haftung (GmbH), Gunderding 8, A-4952, Weng, Austria The manufacturer’s installation manual version 44 for Wood Chip and Pellet Stoves, Type HSV 30-100. Reference BA HSV30-100 RA/RAP V44 0608. The manufacturer’s installation manual version 44 for Wood Chip and Pellet Stoves, Type HSV 30-100. Reference BA HSV30-100 RA/RAP V44 0608. Wood chip or wood pellets⁽¹⁾
Hamont CATfire 350 USZI pellet boiler fitted with CATfirte 300 cyclone, manufactured by Hamont Contracting and Trading, spol. s.r.o., Sedlište 227, postal code 739 36, district Frýdek-Mistek Czech Republic. Operating instruction reference “Operating Manual for Boilers CATfire 150-500kW” effective from 1/1/2008 Operating instruction reference “Operating Manual for Boilers CATfire 150-500kW” effective from 1/1/2008 Wood pellets with a 6mm diameter and a maximum length of 30mm⁽¹⁾
Handöl 31, Handöl 31A, Handöl 32, Handöl 32A, Handöl 33T, Handöl 34T, Handöl 35T, Varde Ovne Look 1, Varde Ovne Look 2, Varde Ovne Look 3 , all manufactured by NIBE AB Box 134, 285 23 Markaryd, Sweden Installation instructions IAV SE/EX 0811-4 511941 Lighting instructions BAV SE/EX H30 511942 A permanent stop must be in place on the air inlet to prevent closure beyond the 45% open position. Installation instructions IAV SE/EX 0811-4 511941 Lighting instructions BAV SE/EX H30 511942 A permanent stop must be in place on the air inlet to prevent closure beyond the 45% open position. Untreated dry wood with less than 20% moisture⁽¹⁾
Handöl 50, Handöl 51, Handöl 52, Handöl 52T, Handöl 53, Handöl 54, Handöl 54T, Handöl 51L, Varde Ovne S1, Varde Ovne S2, Varde Ovne S3, all manufactured by NIBE AB Box 134 285 23 Markaryd, Sweden Installation instruction IAV SE/EX 0737-4 511866 Lighting instruction BAV SE/EX 0717-1 511865 A permanent stop must be in place on the air inlet to prevent closure beyond the 45% open position. Installation instruction IAV SE/EX 0737-4 511866 Lighting instruction BAV SE/EX 0717-1 511865 A permanent stop must be in place on the air inlet to prevent closure beyond the 45% open position. Untreated dry wood with less than 20% moisture⁽¹⁾
Harrie Leenders Cylon Harrie Leenders Doran 160 Harrie Leenders Doran 190 Harrie Leenders Fuga S Harrie Leenders Fuga eL Harrie Leenders Stor Harrie Leenders Signa Stoves manufactured by Harrie Leenders Industrieweg 25 5688 DP Oirschot Netherlands Instruction manual references “Supplementary Instructions Amended June 2010” All appliances will be fitted with a mechanical stop to prevent closure of the air slide beyond the 15mm open position when sold into smoke control areas. Instruction manual references “Supplementary Instructions Amended June 2010” All appliances will be fitted with a mechanical stop to prevent closure of the air slide beyond the 15mm open position when sold into smoke control areas. Wood logs[^f01000]
HDG Compact models 25/35 (25 kW, 35 kW) wood chip and pellet boilers manufactured by HDG Bavaria Gesellschaft mit beschrankter Haftung (GmbH), Siemensstrasse 22, 84323 Massing, Germany The manufacturer’s operating instructions for the HDG Compact 25/35 with HDG Hydronic reference “HDG Compact Version V01” of April 2009 The manufacturer’s operating instructions for the HDG Compact 25/35 with HDG Hydronic reference “HDG Compact Version V01” of April 2009 Wood chip or wood pellets[^f01000]
HDG Compact models 50/65 (50 kW, 65 kW) wood chip and pellet boilers manufactured by HDG Bavaria Gesellschaft mit beschrankter Haftung (GmbH), Siemensstrasse 22, 84323 Massing, Germany The manufacturer’s operating instructions for the HDG Compact 50/65 with HDG Hydronic reference “HDG Compact Version V03” of April 2009 The manufacturer’s operating instructions for the HDG Compact 50/65 with HDG Hydronic reference “HDG Compact Version V03” of April 2009 Wood chip or wood pellets[^f01000]
HDG Compact model 80 (80 kW) wood chip and pellet boiler manufactured by HDG Bavaria Gesellschaft mit beschrankter Haftung (GmbH), Siemensstrasse 22, 84323 Massing, Germany The manufacturer’s operating instructions for the HDG Compact 80 with HDG Hydronic reference “HDG Compact Version V03” of April 2009 The manufacturer’s operating instructions for the HDG Compact 80 with HDG Hydronic reference “HDG Compact Version V03” of April 2009 Wood chip or wood pellets[^f01000]
HDG Compact model 100 (100 kW) wood chip and pellet boiler manufactured by HDG Bavaria Gesellschaft mit beschrankter Haftung (GmbH), Siemensstrasse 22, 84323 Massing, Germany The manufacturer’s operating instructions for the HDG Compact 100/150/200 reference “HDG Compact 100-200 Version V1” of July 2008 The manufacturer’s operating instructions for the HDG Compact 100/150/200 reference “HDG Compact 100-200 Version V1” of July 2008 Wood chip or wood pellets[^f01000]
HDG Compact model 150, 200 (150 kW, 200 kW) wood chip and pellet boiler with model HDG 3113 cyclone manufactured by HDG Bavaria Gesellschaft mit beschrankter Haftung (GmbH), Siemensstrasse 22, 84323 Massing, Germany The manufacturer’s operating instructions for the HDG Compact 100/150/200 reference “HDG Compact 100-200 Version V1” of July 2008 The manufacturer’s operating instructions for the HDG Compact 100/150/200 reference “HDG Compact 100-200 Version V1” of July 2008 Wood chip or wood pellets[^f01000]
HDG Euro models 30, 40 and 50 (30 kW, 40 kW and 50 kW) wood log boilers manufactured by HDG Bavaria Gesellschaft mit beschrankter Haftung (GmbH), Siemensstrasse 22, 84323 Massing, Germany The manufacturer’s operating instructions for the HDG Euro 30/40/50 with Lambda Control 1 reference “HDG Euro V3.0 with HDG Lambda Control 1 Version V1” of June 2008 The manufacturer’s operating instructions for the HDG Euro 30/40/50 with Lambda Control 1 reference “HDG Euro V3.0 with HDG Lambda Control 1 Version V1” of June 2008 Split wood logs of 500 mm length and maximum edge length of 120 mm and a residual moisture content of 20%[^f01000]
HDG Navaro models 20, 25 and 30 (20 kW, 25 kW and 30 kW) wood log boilers manufactured by HDG Bavaria Gesellschaft mit beschrankter Haftung (GmbH), Siemensstrasse 22, 84323 Massing, Germany The manufacturer’s operating instructions for the HDG Navora 20/25/30 with Lambda Control 1 reference “HDG Navora 20/25/30 with HDG Lambda Control 1 Version V2” of June 2008 The manufacturer’s operating instructions for the HDG Navora 20/25/30 with Lambda Control 1 reference “HDG Navora 20/25/30 with HDG Lambda Control 1 Version V2” of June 2008 Split wood logs of 500 mm length and maximum edge length of 120 mm and a residual moisture content of 20%[^f01000]
HDG Pelletmaster model PM15, 15 kW wood pellet boiler manufactured by HDG Bavaria Gesellschaft mit beschrankter Haftung (GmbH), Siemensstrasse 22, 84323 Massing, Germany The manufacturer’s operating instructions for the HDG Pelletmaster 15/25 reference “HDG Pelletmaster Version V1” of October 2006 The manufacturer’s operating instructions for the HDG Pelletmaster 15/25 reference “HDG Pelletmaster Version V1” of October 2006 Wood pellets[^f01000]
Highlander 5 Clean Burn Manufactured by Dunsley Heat Limited, Bridge Mills, Huddersfield, Holmfirth, West Yorkshire, HD9 3TW Instruction manual references “Highlander. The Dunsley – Enviroburn –5. Clean Burn Stove Installation and operating instructions. D12-01-09, D060-01-09, D13-01-09, D12-12-08” Instruction manual references “Highlander. The Dunsley – Enviroburn –5. Clean Burn Stove Installation and operating instructions. D12-01-09, D060-01-09, D13-01-09, D12-12-08” Wood logs⁽¹⁾ conforming to BS EN 13240:2001
The Hoval AgroLyt 20, 25, 35, 45 and 50 manufactured by Hoval AG, Austrasse 70, 9490 Vaduz, Liechtenstein Installation and operation manuals dated January 2006, reference 4 205/ 194/00, and June 2006, reference 205 193/00 Installation and operation manuals dated January 2006, reference 4 205/ 194/00, and June 2006, reference 205 193/00 Wood logs with less than 20% moisture[^f01000]

Reading this document does not replace reading the official text published on legislation.gov.uk. Contains public sector information licensed under the Open Government Licence v3.0. We assume no responsibility for any inaccuracies arising from the conversion of the original CLML XML to this format.

This text is published under legislation.gov.uk's own terms of reuse, not a Legalize or public-domain licence. legislation.gov.uk
Open Government Licence v3.0 (attribution required)
© Crown and database right. Derived from content available under the Open Government Licence v3.0 from legislation.gov.uk.