The Smoke Control Areas (Exempted Fireplaces) (Wales) Order 2014
| Fireplace | Conditions | Conditions | Conditions |
|---|---|---|---|
| Highlander 3 Enviro-burn smoke exempt multi fuel stove. Manufactured by Dunsley Heat Ltd., Bridge Mills, Huddersfield Road, Holmfirth, Yorkshire, HD9 3TW. | Instruction manual reference “ENVIRO 3 DB005” dated 11/02/2013. The appliance must be fitted with a system preventing closure of the secondary air control beyond the 3mm open position. | Instruction manual reference “ENVIRO 3 DB005” dated 11/02/2013. The appliance must be fitted with a system preventing closure of the secondary air control beyond the 3mm open position. | Wood logs [^f01000]. |
| Highlander 5 Clean Burn. Manufactured by Dunsley Heat Ltd., Bridge Mills, Huddersfield Road, Holmfirth, Yorkshire, HD9 3TW. | Manufacturer’s instruction manual reference “Highlander. The Dunsley-Enviroburn-5. Clean Burn Stove Installation and operating instructions, D12-01-09, D060-01-09, D13-01-09, D12-12-08.” | Manufacturer’s instruction manual reference “Highlander. The Dunsley-Enviroburn-5. Clean Burn Stove Installation and operating instructions, D12-01-09, D060-01-09, D13-01-09, D12-12-08.” | Wood logs conforming to BS EN 13240:2001 [^f01000]. |
| Highlander 5 Enviro-burn SOLO Slimline smoke exempt multi fuel stove. Manufactured by Dunsley Heat Ltd., Bridge Mills, Huddersfield Road, Holmfirth, Yorkshire, HD9 3TW. | Instruction manual reference “ENVIRO 5 DB002” dated 02/02/2013. The appliance must be fitted with a system preventing closure of the secondary air control beyond the 3mm open position. | Instruction manual reference “ENVIRO 5 DB002” dated 02/02/2013. The appliance must be fitted with a system preventing closure of the secondary air control beyond the 3mm open position. | Wood logs [^f01000]. |
| Highlander 7 Enviroburn Solo multi-fuel stove (product codes 00325, 00326 and 00327). Manufactured by Dunsley Heat Ltd., Bridge Mills, Huddersfield Road, Holmfirth, Yorkshire, HD9 3TW. | Installation and operating instructions manual reference “ENVIRO 7 DB001” dated 15/06/2012. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air-wash beyond 2mm. Four fixed 5mm diameter air holes are provided for the tertiary air supply. | Installation and operating instructions manual reference “ENVIRO 7 DB001” dated 15/06/2012. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air-wash beyond 2mm. Four fixed 5mm diameter air holes are provided for the tertiary air supply. | Dry wood logs [^f01000]. |
| Hillandale Silverdale 5SE, Amalia 5 and Oppdal 5 multifuel stoves. Manufactured by Broseley Fires Ltd., Knights Way, Battlefield Enterprise Park, Shrewsbury, Shropshire, SY1 3AB. | Instruction manual reference “GB12A Version 1” dated February 2013. The appliance must be fitted with a permanent stop to prevent closure of the secondary air slide beyond the 23mm open position. | Instruction manual reference “GB12A Version 1” dated February 2013. The appliance must be fitted with a permanent stop to prevent closure of the secondary air slide beyond the 23mm open position. | Wood logs [^f01000]. |
| Hillandale Silverdale 7SE, Amalia 7 and Oppdal 7 multifuel stoves. Manufactured by Broseley Fires Ltd., Knights Way, Battlefield Enterprise Park, Shrewsbury, Shropshire, SY1 3AB. | Instruction manual reference “GB12A Version 1” dated February 2013. The appliance must be fitted with a permanent stop to prevent closure of the secondary air slide beyond the 50mm open position. | Instruction manual reference “GB12A Version 1” dated February 2013. The appliance must be fitted with a permanent stop to prevent closure of the secondary air slide beyond the 50mm open position. | Wood logs [^f01000]. |
| Hopwood Multifuel Stove Model HW1MF. Manufactured by ACR Heat Products Ltd., Unit 1, Weston Works, Weston Lane, Tyseley, Birmingham, B11 3RP. | Instruction manual reference “HW1MF 0101” dated 17/07/2013. A permanent stop must be fitted to the secondary air slider to prevent closure beyond the 5mm open position and the tertiary air openings at the rear of the appliance are fixed at 50% open. | Instruction manual reference “HW1MF 0101” dated 17/07/2013. A permanent stop must be fitted to the secondary air slider to prevent closure beyond the 5mm open position and the tertiary air openings at the rear of the appliance are fixed at 50% open. | Wood logs [^f01000]. |
| Horse Flame Little Artemis model number HF277-SE wood burning stove. Manufactured by Hi-Flame Fireplace UK Ltd., Unit 5A, Holmes Chapel Business Park, Manor Lane, Holmes Chapel, Cheshire, CW4 8AF. | Instruction manual reference “AL905-SE/UK-NI-ROI/V2-D.18-07-12” dated July 2012. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 3mm open position. | Instruction manual reference “AL905-SE/UK-NI-ROI/V2-D.18-07-12” dated July 2012. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 3mm open position. | Wood logs [^f01000]. |
| Horse Flame Precision 1 model number HF905-SE. Manufactured by Henan Hi-Flame Metal Co. Ltd., Eastside, Yugang Avenue, Airport District, Zheng Zhou 451163, Henan, China. | Instruction manual reference “HF905/UK-NI-ROI/V2.1-06-11” dated June 2011. The appliance must be fitted with a mechanical stop to prevent closure of the main air control beyond the 50% open position. | Instruction manual reference “HF905/UK-NI-ROI/V2.1-06-11” dated June 2011. The appliance must be fitted with a mechanical stop to prevent closure of the main air control beyond the 50% open position. | Wood logs [^f01000]. |
| Horse Flame Precision II model number HF907-SE wood burning stove. Manufactured by Hi-Flame Fireplace UK Ltd., Unit 5A, Holmes Chapel Business Park, Manor Lane, Holmes Chapel, Cheshire, CW4 8AF. | Instruction manual reference “HF907-SE/UK-NI-ROI/V3-D. 14-07-12” dated July 2012. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 20% open position, and a 70mm opening of the door rope seal to allow a constant flow of air. | Instruction manual reference “HF907-SE/UK-NI-ROI/V3-D. 14-07-12” dated July 2012. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 20% open position, and a 70mm opening of the door rope seal to allow a constant flow of air. | Wood logs [^f01000]. |
| Hothouse 4SE stove. Manufactured by Heat Design, 30 Hawthorn Road, Western Industrial Estate, Naas Road, Dublin 12, Ireland. | Instruction manual reference “HH468SE” dated 25/07/2012. The appliance must be fitted with a system to prevent closure of the secondary air control beyond 5mm open. | Instruction manual reference “HH468SE” dated 25/07/2012. The appliance must be fitted with a system to prevent closure of the secondary air control beyond 5mm open. | Wood logs [^f01000]. |
| Hothouse 06C inset stove. Manufactured by Heat Design, 30 Hawthorn Road, Western Industrial Estate, Naas Road, Dublin 12, Ireland. | Instruction manual reference “HH06C” dated 26/07/2012. The appliance must be fitted with a permanent stop to prevent closure of the secondary air control beyond 20% open. | Instruction manual reference “HH06C” dated 26/07/2012. The appliance must be fitted with a permanent stop to prevent closure of the secondary air control beyond 20% open. | Wood logs [^f01000]. |
| Hothouse 6SE stove. Manufactured by Heat Design, 30 Hawthorn Road, Western Industrial Estate, Naas Road, Dublin 12, Ireland. | Instruction manual reference “HH468SE” dated 25/07/2012. The appliance must be fitted with a system to prevent closure of the secondary air control beyond 75% from closed. | Instruction manual reference “HH468SE” dated 25/07/2012. The appliance must be fitted with a system to prevent closure of the secondary air control beyond 75% from closed. | Wood logs [^f01000]. |
| Hothouse 8SE stove. Manufactured by Heat Design, 30 Hawthorn Road, Western Industrial Estate, Naas Road, Dublin 12, Ireland. | Instruction manual reference “HH468SE” dated 25/07/2012. The appliance must be fitted with a system to prevent closure of the secondary air control beyond 25% from closed. | Instruction manual reference “HH468SE” dated 25/07/2012. The appliance must be fitted with a system to prevent closure of the secondary air control beyond 25% from closed. | Wood logs [^f01000]. |
| Hothouse 11C inset stove. Manufactured by Heat Design, 30 Hawthorn Road, Western Industrial Estate, Naas Road, Dublin 12, Ireland. | Instruction manual reference “HH11C” dated 26/07/2012. The appliance must be fitted with a permanent stop to prevent closure of the secondary air control beyond 20% open. | Instruction manual reference “HH11C” dated 26/07/2012. The appliance must be fitted with a permanent stop to prevent closure of the secondary air control beyond 20% open. | Wood logs [^f01000]. |
| Hothouse Breeze 4SE Multi-fuel stove. Manufactured by Heat Design Ltd., 30 Hawthorn Road, Western Industrial Estate, Naas Road, Dublin 12, Ireland. | Installation and Operating Instruction manual reference “HHB468SE” dated 02/05/2013. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 5mm open position. | Installation and Operating Instruction manual reference “HHB468SE” dated 02/05/2013. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 5mm open position. | Wood logs [^f01000]. |
| Hothouse Breeze 5i Multi-fuel inset stove. Manufactured by Heat Design Ltd., 30 Hawthorn Road, Western Industrial Estate, Naas Road, Dublin 12, Ireland. | Installation and Operating Instruction manual reference “HHB5i” dated 02/05/2013. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 3.5mm open position. | Installation and Operating Instruction manual reference “HHB5i” dated 02/05/2013. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 3.5mm open position. | Wood logs [^f01000]. |
| Hothouse Breeze 6SE Multi-fuel stove. Manufactured by Heat Design Ltd., 30 Hawthorn Road, Western Industrial Estate, Naas Road, Dublin 12, Ireland. | Installation and Operating Instruction manual reference “HHB468SE” dated 02/05/2013. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 25% open position. | Installation and Operating Instruction manual reference “HHB468SE” dated 02/05/2013. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 25% open position. | Wood logs [^f01000]. |
| Hothouse Breeze 8SE Multi-fuel stove. Manufactured by Heat Design Ltd., 30 Hawthorn Road, Western Industrial Estate, Naas Road, Dublin 12, Ireland. | Installation and Operating Instruction manual reference “HHB468SE” dated 02/05/2013. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 75% open position. | Installation and Operating Instruction manual reference “HHB468SE” dated 02/05/2013. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 75% open position. | Wood logs [^f01000]. |
| Hothouse HH5i Multi-fuel inset stove. Manufactured by Heat Design Ltd., 30 Hawthorn Road, Western Industrial Estate, Naas Road, Dublin 12, Ireland. | Installation and Operating Instruction manual reference “HH5i” dated 02/05/2013. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 3.5mm open position. | Installation and Operating Instruction manual reference “HH5i” dated 02/05/2013. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 3.5mm open position. | Wood logs [^f01000]. |
| Hotpod Unlimited; Hotpod Limited Edition. Manufactured by Hotpod LLP, PO Box 137, St Ives, Cornwall, TR26 2WW. | Instruction manual reference “Version 3” dated June 2011. | Instruction manual reference “Version 3” dated June 2011. | Wood logs [^f01000]. |
| The Hoval AgroLyt 20, 25, 35, 45 and 50. Manufactured by Hoval AG, Austrasse 70, 9490 Vaduz, Liechtenstein. | Manufacturer’s technical information and installation instructions reference “4 205 194/00” dated January 2006 and reference “4 205 193/00” dated June 2006. | Manufacturer’s technical information and installation instructions reference “4 205 194/00” dated January 2006 and reference “4 205 193/00” dated June 2006. | Wood logs with less than 20% moisture [^f01000]. |
| Hoval BioLyt Wood Pellet Boiler. Manufactured by Hoval UK Ltd., Northgate, Newark, Nottinghamshire, NG24 1JN. | The instruction manual reference “Hoval Operating Instructions, wood pellet heating boiler BioLyt (50,70,120,140,160)” dated 03/07/2008 and reference “Technical information assembly instructions” dated 03/10/2009. | The instruction manual reference “Hoval Operating Instructions, wood pellet heating boiler BioLyt (50,70,120,140,160)” dated 03/07/2008 and reference “Technical information assembly instructions” dated 03/10/2009. | Wood pellets [^f01000]. |
| The Hoval BioLyt 50 Wood Pellet Boiler (49kW thermal output). Manufactured by Hoval AG, Austrasse 70, 9490 Vaduz, Liechtenstein. | Manufacturer’s technical information and installation instructions reference “4 204794/00” dated October 2005 and operating instructions reference “4 204 793/01” dated January 2006. | Manufacturer’s technical information and installation instructions reference “4 204794/00” dated October 2005 and operating instructions reference “4 204 793/01” dated January 2006. | Wood pellets [^f01000]. |
| The Hoval BioLyt 50 and 70 models. Manufactured by Hoval AG, Austrasse 70, 9490 Vaduz, Liechtenstein. | Manufacturer’s technical information and installation instructions references “4 204 794/01” and “4 204 793/02” dated June 2007. | Manufacturer’s technical information and installation instructions references “4 204 794/01” and “4 204 793/02” dated June 2007. | Wood pellets [^f01000]. |
| Hoval BioLyt 160 pellet boiler. Manufactured by Hoval UK Ltd., Northgate, Newark, Nottinghamshire, NG24 1JN. | Instruction manual reference “Hoval Operating Instructions, wood pellet heating boiler BioLyt (50,70,120,140,160)” dated 03/07/2008 and “Technical information assembly instructions” dated 03/10/2009. | Instruction manual reference “Hoval Operating Instructions, wood pellet heating boiler BioLyt (50,70,120,140,160)” dated 03/07/2008 and “Technical information assembly instructions” dated 03/10/2009. | Wood pellets [^f01000]. |
| Hoval Forester MGS 150, 180, 240, 300, 360, 450, 550, 700, 900 boilers. Manufactured by Schmid AG Woodfiring systems, PO Box 42, CH-8380 Eschikon, Switzerland. | Relevant instruction manual reference “Hoval Forester MGS_MMXXXv1” (where XXX is the unit size for example 150) dated July 2011. | Relevant instruction manual reference “Hoval Forester MGS_MMXXXv1” (where XXX is the unit size for example 150) dated July 2011. | Wood pellets or wood chips following CEN/TS 14961 [^f01000]. |
| Hoval Forester UFS 180, 240, 300, 360, 450, 550, 700, 900, 1200, 1600. Manufactured by Schmid AG Woodfiring Systems, PO Box 42, CH-8360 Eschlikon, Switzerland. | Instruction manual reference “Forester UFS” dated November 2009. | Instruction manual reference “Forester UFS” dated November 2009. | Wood pellets or wood chips following CEN/TS 14961 [^f01000]. |
| The Hoval STU 150, 200, 250, 300, 350, 425 and 500. Manufactured by Hoval UK Ltd., Northgate, Newark, Nottinghamshire, NG24 1JN. | Manufacturer’s technical information and installation instructions reference “STUman/01” dated November 2007 or reference “STU/man/01/1” dated June 2008. | Manufacturer’s technical information and installation instructions reference “STUman/01” dated November 2007 or reference “STU/man/01/1” dated June 2008. | Wood pellets [^f01000]. |
| The Hoval STU 600, 800 and 1000. Manufactured by Hoval UK Ltd., Northgate, Newark, Nottinghamshire, NG24 1JN. | Installation and operation manual reference “STU/man/01” dated November 2007 or the installation and operation manual reference “STU/man/01/1” dated June 2008. | Installation and operation manual reference “STU/man/01” dated November 2007 or the installation and operation manual reference “STU/man/01/1” dated June 2008. | Wood pellets [^f01000]. |
| HSV 50 + WTH 45, 49 or 55; HSV 80 + WTH 70 or 80; HSV 100 + WTH 100. Manufactured by Hargassner Gesellschaft mit beschränkter Haftung (GmbH), Gunderding 8, A-4952, Weng, Austria. | Manufacturer’s installation manual version 44 for Wood Chip and Pellet Stoves, Type HSV 30-100. Reference “BA HSV30-100 RA/RAP V44 0608”. | Manufacturer’s installation manual version 44 for Wood Chip and Pellet Stoves, Type HSV 30-100. Reference “BA HSV30-100 RA/RAP V44 0608”. | Wood chips or wood pellets [^f01000]. |
| Hunter Avalon 5 Inset stove. Manufactured by Hunter Stoves Ltd., Trevilla Park, Slaughterbridge, Camelford, Cornwall, PL32 9TT. | Instruction manual reference “JINAVI05 Rev B” dated 10/10/2012. The valve plate adjusted by the secondary air control must contain six 5mm holes. | Instruction manual reference “JINAVI05 Rev B” dated 10/10/2012. The valve plate adjusted by the secondary air control must contain six 5mm holes. | Wood logs [^f01000]. |
| Hunter Herald 4. Manufactured by Hunter Stoves Ltd., Trevilla Park, Slaughterbridge, Camelford, Cornwall, PL32 9TT. | Instruction manual reference “JINHH04 revC” dated 22/09/2011 and “JINHH04&HHC05 Slider Stop revA” dated 22/07/2011. The appliance must be fitted with a permanent stop that prevents closure of the secondary air slider beyond 30% open. | Instruction manual reference “JINHH04 revC” dated 22/09/2011 and “JINHH04&HHC05 Slider Stop revA” dated 22/07/2011. The appliance must be fitted with a permanent stop that prevents closure of the secondary air slider beyond 30% open. | Wood logs [^f01000]. |
| Hunter Herald 5 Compact. Manufactured by Hunter Stoves Ltd., Trevilla Park, Slaughterbridge, Camelford, Cornwall, PL32 9TT. | Instruction manual reference “JINHHC05 revC” dated 22/09/2011 and “JINHH04&HHC05 Slider Stop revA” dated 22/07/2011. The appliance must be fitted with a permanent stop that prevents closure of the secondary air slider beyond 30% open. | Instruction manual reference “JINHHC05 revC” dated 22/09/2011 and “JINHH04&HHC05 Slider Stop revA” dated 22/07/2011. The appliance must be fitted with a permanent stop that prevents closure of the secondary air slider beyond 30% open. | Wood logs [^f01000]. |
| Hunter Herald 5 Slimline. Manufactured by Hunter Stoves Ltd., Trevilla Park, Slaughterbridge, Camelford, Cornwall, PL32 9TT. | Instruction manual reference “JINHHW05 revC” dated 22/09/2011. | Instruction manual reference “JINHHW05 revC” dated 22/09/2011. | Wood logs [^f01000]. |
| Hunter Herald 6. Manufactured by Hunter Stoves Ltd., Trevilla Park, Slaughterbridge, Camelford, Cornwall, PL32 9TT. | Instruction manual reference “JINHH04 revC” dated 22/09/2011. | Instruction manual reference “JINHH04 revC” dated 22/09/2011. | Wood logs [^f01000]. |
| Hunter Herald 8 slimline CE vII stove. Manufactured by Hunter Stoves Ltd., Trevilla Park, Slaughterbridge, Camelford, Cornwall, PL32 9TT. | Instruction manual reference “JINHHW08 revB” dated 24/01/2013. | Instruction manual reference “JINHHW08 revB” dated 24/01/2013. | Wood logs [^f01000]. |
| Hunter Herald i4. Manufactured by Hunter Stoves Ltd., Trevilla Park, Slaughterbridge, Camelford, Cornwall, PL32 9TT. | Instruction manual reference “JINHVR04 Rev E” dated 02/12/2011 and instruction manual reference “JINHVR04SCK revB” dated 05/12/2011. The appliance must be fitted with smoke control area kit JHVR0401. | Instruction manual reference “JINHVR04 Rev E” dated 02/12/2011 and instruction manual reference “JINHVR04SCK revB” dated 05/12/2011. The appliance must be fitted with smoke control area kit JHVR0401. | Wood logs [^f01000]. |
| Hunter Telford 5 Inset stove. Manufactured by Hunter Stoves Ltd., Trevilla Park, Slaughterbridge, Camelford, Cornwall, PL32 9TT. | Instruction manual reference “JINTDI05 rev B” dated 10/10/2012. The valve plate adjusted by the secondary air control must contain six 5mm holes. | Instruction manual reference “JINTDI05 rev B” dated 10/10/2012. The valve plate adjusted by the secondary air control must contain six 5mm holes. | Wood logs [^f01000]. |
| The Huntingdon 25 clear door (model number 7057) and Huntingdon 25 tracery door (model number 7058). Manufactured by Stovax Ltd., Falcon Road, Sowerton Industrial Estate, Exeter, Devon EX2 7LF. | Manufacturer’s instruction manual reference “PM 249 Issue 1”. A permanent stop must be in place on the secondary air inlet to prevent closure beyond the 75% open position. | Manufacturer’s instruction manual reference “PM 249 Issue 1”. A permanent stop must be in place on the secondary air inlet to prevent closure beyond the 75% open position. | Untreated dry wood [^f01000]. |
| The Hwam Beethoven, Hwam Beethoven H, Hwam Mozart, Hwam Ravel, Hwam Vivaldi, Hwam 30 (4.5kW nominal thermal output). Manufactured by HWAM Heat Design AS Nydamsvej 53, 8362 Hørning, Denmark. | Euroheat Distributors (HBS) Ltd.’s operational instructions reference “IN1 141 Ed B” dated November 2006. The appliance must be fitted with a mechanism to prevent closure of the air wash/secondary air control. | Euroheat Distributors (HBS) Ltd.’s operational instructions reference “IN1 141 Ed B” dated November 2006. The appliance must be fitted with a mechanism to prevent closure of the air wash/secondary air control. | Untreated dry wood [^f01000]. |
| Ild 1 and Ild 4 stoves. Manufactured by Color Emajl d.o.o., Alaginci 87/a, HR-34000 Požega, Croatia. | Instruction manual reference “11.1c” dated February 2012. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 83mm open position. | Instruction manual reference “11.1c” dated February 2012. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 83mm open position. | Wood logs [^f01000]. |
| Ild 2 and Ild 5 stoves. Manufactured by Color Emajl d.o.o., Alaginci 87/a, HR-34000 Požega, Croatia. | Instruction manual reference “11-1d” dated February 2012. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 83mm open position. | Instruction manual reference “11-1d” dated February 2012. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 83mm open position. | Wood logs [^f01000]. |
| Ild 6 Insert stove. Manufactured by Color Emajl d.o.o., Alaginci 87/a, HR-34000 Požega, Croatia. | ILD 6 Insert stove Instruction manual reference “12-1b GB” dated 25/02/2013. The appliance must be fitted with a permanent stop preventing closure of the secondary air control beyond 18% open. | ILD 6 Insert stove Instruction manual reference “12-1b GB” dated 25/02/2013. The appliance must be fitted with a permanent stop preventing closure of the secondary air control beyond 18% open. | Wood logs [^f01000]. |
| Ild 7 and Ild 8 wood-burning stoves. Manufactured by Color Emajl d.o.o., Alaginci 87/a, HR-34000 Požega, Croatia. | Instruction manual reference “Manual version. No. 13-1 GB 01.07.13” dated 01/07/2013. The appliance must be fitted with a permanent stop to fix the secondary air control at 7.5% open when in the fully closed position. | Instruction manual reference “Manual version. No. 13-1 GB 01.07.13” dated 01/07/2013. The appliance must be fitted with a permanent stop to fix the secondary air control at 7.5% open when in the fully closed position. | Wood logs [^f01000]. |
| The Insert 50 Crystal, Insert 70 Crystal and Insert 80 Crystal. Manufactured by LaNordica Spa, Via Summano 104 M. Precalcino, 36030, Vicenza, Italy. | Instruction manual reference “6096801-Rev.17” dated 22/12/2010. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 40% open position. | Instruction manual reference “6096801-Rev.17” dated 22/12/2010. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 40% open position. | Wood logs [^f01000]. |
| Insert 100 Crystal. Manufactured by, LaNordica Spa, Via Summano 104 M. Precalcino, 36030, Vicenza, Italy. | Instruction manual reference “6096801-Rev.17” dated 22/12/2010. | Instruction manual reference “6096801-Rev.17” dated 22/12/2010. | Wood logs [^f01000]. |
| Instyle 400; Instyle 550. Manufactured by Dik Geurts Haardkachels BV; Industrieweg Oost 11, 6662 NE Elst (Gld), The Netherlands. | Instruction manual reference “Instruction_manual_Instyle_1209_ENG”. | Instruction manual reference “Instruction_manual_Instyle_1209_ENG”. | Wood logs [^f01000]. |
| Italy Built In. Manufactured by La Nordica Spa, Via Summano 104 M. Precalcino, 36030, Vicenza, Italy. | Instruction manual reference “7095401 Rev.02” dated 13/12/2010. | Instruction manual reference “7095401 Rev.02” dated 13/12/2010. | Wood logs [^f01000]. |
| Italy Imported wood burning ovens: Etna, Amiata, Stromboli and Vesuvius. Manufactured by Italy Imported Ltd., Avenue House, Southgate, Chichester, PO19 1ES. | Installation & Operation manual reference “E.A.S.V. ISSUE 1” dated July 2013. | Installation & Operation manual reference “E.A.S.V. ISSUE 1” dated July 2013. | Wood logs [^f01000]. |
| Italy Termo Built-in DSA (back boiler cooker). Manufactured by La Nordica PA, Via Summano, 104 Montecchio Precalcino, Vicenza, 36030, Italy. | Instructions for installation, use and maintenance manual reference “7095703 – IT-EN-DE-FR” dated July 2013. | Instructions for installation, use and maintenance manual reference “7095703 – IT-EN-DE-FR” dated July 2013. | Wood logs [^f01000]. |
| Italy Termo DSA; Termosuprema Compact DSA. Manufactured by LaNordica Spa, Via Summano 104 M. Precalcino, 36030, Vicenza, Italy. | Instruction manual reference “7095802 Rev.06” dated 01/02/2011. | Instruction manual reference “7095802 Rev.06” dated 01/02/2011. | Wood logs [^f01000]. |
| Ivanhoe JS5000 multi-fuel. Manufactured by James Smellie Ltd., Unit N, Leona Industrial Estate, Nimmings Road, Halesowen, West Midlands, B62 9JQ. | Instruction manual reference “Ivanhoe multi-fuel stove instruction manual Issue 1” dated June 2012. | Instruction manual reference “Ivanhoe multi-fuel stove instruction manual Issue 1” dated June 2012. | Wood logs [^f01000]. |
| JC Bordelet EVA 992 Centrale Foyer Fermé (vitrée) enclosed wood-burning stove; JC Bordelet EVA 992 Murale (vitrée) enclosed wood-burning stove; and JC Bordelet EVA 992 Angle (vitrée) enclosed wood-burning stove. Manufactured by Groupe Seguin, Cheminees Seguin Duteriez, Zone Industrielle de Lhérat, 63310 France. | EVA 992 Instruction manual reference “FIREPLACES MANUAL INSTALLATION – USE – 1 / 04 / 07 CHARACTERISTICS OF THE FIREPLACE” dated 01/04/2007. | EVA 992 Instruction manual reference “FIREPLACES MANUAL INSTALLATION – USE – 1 / 04 / 07 CHARACTERISTICS OF THE FIREPLACE” dated 01/04/2007. | Wood logs [^f01000]. |
| JC Bordelet LEA 998 centrale foyer fermé (vitrée) enclosed wood-burning stove; and JC Bordelet LEA 998 Murale (vitrée) enclosed wood-burning stove. Manufactured by Groupe Seguin, Cheminees Seguin Duteriez, Zone Industrielle de Lhérat, 63310 France. | LEA 998 Instruction manual reference “FIREPLACES MANUAL INSTALLATION – USE – 1 / 04 / 07 CHARACTERISTICS OF THE FIREPLACE” dated 01/04/2007. | LEA 998 Instruction manual reference “FIREPLACES MANUAL INSTALLATION – USE – 1 / 04 / 07 CHARACTERISTICS OF THE FIREPLACE” dated 01/04/2007. | Wood logs [^f01000]. |
| Jetmaster 18f stove. Manufactured by Jetmaster Fires Ltd., Unit 2, Peacock Trading Estate, Goodwood Road, Eastleigh, Hampshire, SO50 4NT. | Instruction manual reference “106870/18f/60f/Issue No.5” dated “June 2011”. | Instruction manual reference “106870/18f/60f/Issue No.5” dated “June 2011”. | Dry wood logs [^f01000]. |
| Jotul F100 Stove. Manufactured by Jotul UK Ltd., Unit 1, The IO Centre, Nash Road, Park Farm, Redditch, Worcestershire, B98 7AS. | Instruction manual reference “129980” dated September 2002 and smoke control area modification reference “UK F100 SC appendix” dated 2010. The appliance must be fitted with a permanent stop that prevents the closure of the secondary air control beyond the 50% open position. | Instruction manual reference “129980” dated September 2002 and smoke control area modification reference “UK F100 SC appendix” dated 2010. The appliance must be fitted with a permanent stop that prevents the closure of the secondary air control beyond the 50% open position. | Wood logs [^f01000] |
| Jotul F162, F163, F262 and F263. Manufactured by Jotul UK Ltd., Unit 1, The IO Centre, Nash Road, Park Farm, Redditch, Worcestershire, B98 7AS. | Instruction manual reference “Jotul F162/F162C/F163 Manual Version Po6” dated January 2011 and Supplementary instruction manual reference “Jotul F162/F163/262/263 SMOKE” dated 01/01/2012. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 20% open position. | Instruction manual reference “Jotul F162/F162C/F163 Manual Version Po6” dated January 2011 and Supplementary instruction manual reference “Jotul F162/F163/262/263 SMOKE” dated 01/01/2012. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 20% open position. | Wood logs [^f01000]. |
| Jydepejsen Country 510 and 760 5kW stoves. Manufactured by Jydepejsen A/S, Ahornsvinget 3-7, Nr.Felding, DK-7500, Holstebro, Denmark. | Instruction user manual “Country001” reference “Jydepejsen A/S - June 2011” dated June 2011. A permanent stop must be fitted to the secondary air control such that it cannot be closed less than 35%. | Instruction user manual “Country001” reference “Jydepejsen A/S - June 2011” dated June 2011. A permanent stop must be fitted to the secondary air control such that it cannot be closed less than 35%. | Wood logs [^f01000]. |
| KARA KW990 woodchip boiler. Manufactured by KARA Energy Systems B.V., P.O. Box 570, 7600 AN Almelo, Plesmanweg 27, 7602 PD Almelo, The Netherlands. | Instruction manual reference “Maintenance and Operation Guide KARA Wood Fired Boiler Version 2012.02” dated 26/07/2012. | Instruction manual reference “Maintenance and Operation Guide KARA Wood Fired Boiler Version 2012.02” dated 26/07/2012. | Woodchip [^f01000]. |
| KÖB Pyromat-DYN (KPM-DYN) 45, 65, 85. Manufactured by Viessman Ltd., Hortonwood 30, Telford, Shropshire, TF1 7YP. | Instruction manual reference “ID 103689-L English” dated 01/01/2005 and instruction manual reference “ID: 103708-G English”. | Instruction manual reference “ID 103689-L English” dated 01/01/2005 and instruction manual reference “ID: 103708-G English”. | Wood logs (up to 0.5m) and off cuts of natural timber, wood chips and pellets [^f01000]. |
| KÖB Pyromat-ECO (KPM-ECO) models 35, 45, 55, 65, 75, 85. Manufactured by Viessman Ltd., Hortonwood 30, Telford, Shropshire, TF1 7YP. | Instruction manual reference “ID 104646-D English” dated 01/01/2005 and instruction manual reference “ID: 104642-B English”. | Instruction manual reference “ID 104646-D English” dated 01/01/2005 and instruction manual reference “ID: 104642-B English”. | Wood logs (up to 0.5m) and off cuts of natural timber [^f01000]. |
| KÖB Pyromat-ECO (KPM-ECO) models 61, 81, 101, 151. Manufactured by Viessman Ltd., Hortonwood 30, Telford, Shropshire, TF1 7YP. | Instruction manual reference “ID 104646-D English” dated 01/01/2005 and instruction manual reference “ID: 104642-B English”. | Instruction manual reference “ID 104646-D English” dated 01/01/2005 and instruction manual reference “ID: 104642-B English”. | Wood logs (up to 1.0m) and off cuts of natural timber [^f01000]. |
| KÖB Pyrot (KRT) models 100, 150, 220, 300, 400, 540. Manufactured by Viessman Ltd., Hortonwood 30, Telford, Shropshire, TF1 7YP. | Instruction manual reference “ID 104654-H English” dated 01/01/2005 and instruction manual reference “ID: 106811-H English”. | Instruction manual reference “ID 104654-H English” dated 01/01/2005 and instruction manual reference “ID: 106811-H English”. | Wood chips or wood pellets [^f01000]. |
| KÖB Pyrtec (KPT) models 390, 530, 720, 950, 1250. Manufactured by Viessman Ltd., Hortonwood 30, Telford, Shropshire, TF1 7YP. | Instruction manual reference “ID 104661-F English” dated 01/01/2005 and instruction manual reference “ID: 105174-F English”. The appliance must be fitted with multi-cyclone dedusters. | Instruction manual reference “ID 104661-F English” dated 01/01/2005 and instruction manual reference “ID: 105174-F English”. The appliance must be fitted with multi-cyclone dedusters. | Wood chips or wood pellets [^f01000]. |
| Kooga Cleanburn Stove. Manufactured by Percy Doughty & Co Ltd., Imperial Point, Express Trading Estate, Stonehill Road, Farnworth, Bolton, BL4 9TN. | Instruction manual reference “KCB 04/10A” dated April 2010. | Instruction manual reference “KCB 04/10A” dated April 2010. | Wood logs [^f01000]. |
| KOZ550, 639kW pellet boiler. Manufactured by Kayalioglu Kasabasi (Izmir-Istanbul Yolu Uzeri), PK23 Akhisar/Manisa, Turkey. | Green Energy Engineering Ltd. (GEE) KOZ550 pellet boiler owner/operator’s manual reference “version 1A 2010” dated December 2010. Glosfume Ltd. maintenance and instruction manual for Glosfume BMF Biomass filter units (50 to 1000kW) reference “version AEE001-VER4” dated December 2010. The appliance must be used with a Glosfume model BMF 208 ceramic particulate filter. | Green Energy Engineering Ltd. (GEE) KOZ550 pellet boiler owner/operator’s manual reference “version 1A 2010” dated December 2010. Glosfume Ltd. maintenance and instruction manual for Glosfume BMF Biomass filter units (50 to 1000kW) reference “version AEE001-VER4” dated December 2010. The appliance must be used with a Glosfume model BMF 208 ceramic particulate filter. | 6mm diameter wood pellets [^f01000]. |
| KP12, KP22 and KP62 wood pellet boilers. Manufactured by PONAST spol. s r.o., Na Potůčkách 163, Valašské Meziříčí, 757 01, Czech Republic. | Service manual reference “QPP051-2” dated 25/05/2012 and instructions for operation manual reference “QPP049-3” dated 25/05/2012. | Service manual reference “QPP051-2” dated 25/05/2012 and instructions for operation manual reference “QPP049-3” dated 25/05/2012. | Wood pellets [^f01000]. |
| KWB Easyfire EF2 S/GS/V 8, 12, 15, 22, 25, 30 and 35 wood pellet boilers. Manufactured by KWB – Kraft und Wärme aus Biomasse Gesellschaft mit Beschränkter Haftung (GmbH), Industriestrasse 235, A-8321 St. Margarethen an der Raab, Austria. | Operation manual reference “B KWB Easyfire EN, 05.2011” dated May 2011 and installation manual reference “M KWB Easyfire, 05.2011” dated May 2011. | Operation manual reference “B KWB Easyfire EN, 05.2011” dated May 2011 and installation manual reference “M KWB Easyfire, 05.2011” dated May 2011. | Wood pellets [^f01000]. |
| KWB Multifire 15, 25, 30, 40, 50, 60, 80, 99 and 100 wood-pellet and wood-chip fired boilers. Manufactured by KWB – Kraft und Wärme aus Biomasse Gesellschaft mit Beschränkter Haftung (GmbH), Industriestrasse 235, A-8321 St. Margarethen an der Raab, Austria. | The fireplace(s) must be installed, maintained and operated in accordance with the manufacturer’s instructions reference “BA-USV 0803” dated August 2003. | The fireplace(s) must be installed, maintained and operated in accordance with the manufacturer’s instructions reference “BA-USV 0803” dated August 2003. | Wood chips and wood pellets [^f01000]. |
| KWB Multifire USV 49.5kW wood chip and wood pellet boiler. Manufactured by KWB – Kraft und Wärme aus Biomasse Gesellschaft mit Beschränkter Haftung (GmbH), Industriestrasse 235, A-8321 St. Margarethen an der Raab, Austria. | Instruction manual reference “BA Multifire 06.2010” dated June 2010. | Instruction manual reference “BA Multifire 06.2010” dated June 2010. | Wood chips and wood pellets [^f01000]. |
| KWB Powerfire TDS 200 199kW Boiler. Manufactured by KWB — Kraft und Wärme aus Biomasse Gesellschaft mit Beschränkter Haftung (GmbH), Industriestrasse 235, A-8321 St. Margarethen an der Raab, Austria. | Operation manual reference “B KWB Powerfire 200–300kW, EN, 09.2012” dated April 2013. | Operation manual reference “B KWB Powerfire 200–300kW, EN, 09.2012” dated April 2013. | Wood pellets or Wood chips [^f01000]. |
| The KWB TDS Powerfire 130, 240 and 300. Manufactured by KWB – Kraft und Wärme aus Biomasse Gesellschaft mit Beschränkter Haftung (GmbH), Industriestrasse 235, A-8321 St. Margarethen an der Raab, Austria. | Manufacturer’s instructions reference “BA TDS-05.2008” dated 14 May 2008, including specification of recommended fuels. | Manufacturer’s instructions reference “BA TDS-05.2008” dated 14 May 2008, including specification of recommended fuels. | Wood pellets or wood chips ⁽¹⁾. |
| The KWB TDS Powerfire 150. Manufactured by KWB – Kraft und Wärme aus Biomasse Gesellschaft mit Beschränkter Haftung (GmbH), Industriestrasse 235, A-8321 St. Margarethen an der Raab, Austria. | Manufacturer’s instructions reference “BA TDS – 0805” dated August 2005. | Manufacturer’s instructions reference “BA TDS – 0805” dated August 2005. | Wood pellets or wood chips [^f01000]. |
| Lin-ka H 1500 Hot Water Boiler fitted with either a mono-cyclone (type LIN-KA 2000) or a multi-cyclone (type LIN-KA 3x2). Manufactured by LIN-KA Maskinfabrik A/S, Nylandsvej 38, DK-6940 Lem St. Denmark. | Instruction manual reference “LIN-KA H 1500 Hot Water Manual/Ver. 2005/Rev. 1.10” dated 27/01/2010. | Instruction manual reference “LIN-KA H 1500 Hot Water Manual/Ver. 2005/Rev. 1.10” dated 27/01/2010. | Wood pellets of maximum 8mm diameter [^f01000]. |
| The Little Thurlow wood burning stove. Manufactured by Town and Country Fires Ltd., 1 Enterprise Way, Thornton Road Industrial Estate, Pickering, North Yorkshire, YO18 7NA. | Manufacturer’s instructions reference “issue No. 3.” dated 30/06/2007. | Manufacturer’s instructions reference “issue No. 3.” dated 30/06/2007. | Seasoned logs of less than 20% moisture and of a maximum length of 350mm [^f01000]. |
| Little Wenlock Classic SE Wood Fuel Stove. Manufactured by Aga, Station Road, Ketley, Telford, Shropshire, TF1 5AQ. | Operating instructions reference “N00471AXX Rev 001 DP 081219” dated 19/12/2008. | Operating instructions reference “N00471AXX Rev 001 DP 081219” dated 19/12/2008. | Dry and split wood logs of a maximum length of 25cm and a maximum diameter of 10cm [^f01000]. |
| LogFire LF6cT Wood Burning Stove. Manufactured by LogFire Stoves Ltd., Britannia House, Junction Street, Darwen, Lancashire, BB3 2RB. | Instruction manual reference “LF6cT-1” dated 18/12/2012. The appliance must be fitted with a mechanical stop to prevent closure of the air control slots beyond the 21mm open position. | Instruction manual reference “LF6cT-1” dated 18/12/2012. The appliance must be fitted with a mechanical stop to prevent closure of the air control slots beyond the 21mm open position. | Wood logs [^f01000]. |
| Lotus H370 Petite 6.6kW insert stove. Manufactured by Lotus Heating Systems A/S; Agertoften 6, 5550 Langeskov, Denmark. | Instruction manual reference “Fireplace Insert, Lotus H370 Petite Version 1” dated 11/10/2012. The appliance must be fitted with a mechanical stop to prevent closure of the air damper beyond the 5mm open position. | Instruction manual reference “Fireplace Insert, Lotus H370 Petite Version 1” dated 11/10/2012. The appliance must be fitted with a mechanical stop to prevent closure of the air damper beyond the 5mm open position. | Wood logs [^f01000]. |
| Lotus Liva 1, Liva 2, Liva 3 and Liva 4G stoves. Manufactured by Lotus Heating Systems A/S; Agertoften 6, 5550 Langeskov, Denmark. | Instruction manual reference “Mounting and User Instructions Lotus-Liva series Stoves Version 4” dated January 2010. | Instruction manual reference “Mounting and User Instructions Lotus-Liva series Stoves Version 4” dated January 2010. | Wood logs [^f01000]. |
| Lotus Sola, Sola S, Sola M and Sola MST stoves. Manufactured by Lotus Heating Systems A/S, Agertoften 6, 5550 Langeskov, Denmark. | Instruction manual reference “Mounting and User Instructions Lotus-Sola series Stoves Version 2” dated January 2010. | Instruction manual reference “Mounting and User Instructions Lotus-Sola series Stoves Version 2” dated January 2010. | Wood logs [^f01000]. |
| The Løvenholm. Manufactured by Hunter Stoves Ltd., Trevilla Park, Slaughterbridge, Camelford, Cornwall, PL32 9TT. | Manufacturer’s installation and operation manual reference “version 07/08”. | Manufacturer’s installation and operation manual reference “version 07/08”. | Untreated wood with less than 20% moisture content [^f01000]. |
| The Løvenholm, Løvenholm Traditional, European and Pedestal Stoves. Manufactured by Hunter Stoves Ltd., Trevilla Park, Slaughterbridge, Camelford, Cornwall, PL32 9TT. | Manufacturer’s instructions “Løvenholm Multifuel stove installation and operating manual” reference “version 06/09”. | Manufacturer’s instructions “Løvenholm Multifuel stove installation and operating manual” reference “version 06/09”. | Untreated wood with less than 20% moisture content ⁽¹⁾. |
| Loxton 3 stoves. Manufactured by Mendip Stoves Ltd., Unit H1, Mendip Industrial Estate, Mendip Road, Rooksbridge, Somerset, BS26 2UG. | Instruction manual reference “Mendip Stoves Ltd., 2012, ver 3” dated July 2012. The appliance must be fitted with a permanent stop to fix the secondary air control such that it cannot be closed more than 25% open. | Instruction manual reference “Mendip Stoves Ltd., 2012, ver 3” dated July 2012. The appliance must be fitted with a permanent stop to fix the secondary air control such that it cannot be closed more than 25% open. | Wood logs [^f01000]. |
| Loxton 5, Churchill 5 and Sqabox Uno stoves. Manufactured by Mendip Stoves Ltd., Unit H1, Mendip Industrial Estate, Mendip Road, Rooksbridge, Somerset, BS26 2UG. | Instruction manual reference “Mendip Stoves Ltd., 2012, ver 3” dated July 2012. The appliance must be fitted with a permanent stop such that the secondary air ‘closed position’ results in a 2.5mm gap in the two secondary air openings. | Instruction manual reference “Mendip Stoves Ltd., 2012, ver 3” dated July 2012. The appliance must be fitted with a permanent stop such that the secondary air ‘closed position’ results in a 2.5mm gap in the two secondary air openings. | Wood logs [^f01000]. |
| Loxton 6, Loxton 8, Churchill 6, Churchill 8 and Sqabox Duo stoves. Manufactured by Mendip Stoves Ltd., Unit H1, Mendip Industrial Estate, Mendip Road, Rooksbridge, Somerset, BS26 2UG. | Instruction manual reference “Mendip Stoves Ltd., 2012, ver 3” dated July 2012. The appliance must be fitted with a permanent stop on the secondary air control such that it cannot be closed more than 35% open. | Instruction manual reference “Mendip Stoves Ltd., 2012, ver 3” dated July 2012. The appliance must be fitted with a permanent stop on the secondary air control such that it cannot be closed more than 35% open. | Wood logs [^f01000]. |
| Ludlow Wood Burning Smoke Exempt Stove (Ludlow Stove SE). Manufactured by Aga, Station Road, Ketley, Telford, Shropshire, TF1 5AQ. | Instruction manual reference “N00529AXX REV:001” dated 13/07/2011. | Instruction manual reference “N00529AXX REV:001” dated 13/07/2011. | Dry wood logs [^f01000]. |
| Marvic Multifuel Cassette (inset) roomheater. Manufactured by Wanders Fires & Stoves, Amtweg 4, Netterden, NL-7077 AL, The Netherlands. | Instruction manual reference “INK.00.7927” dated 20/12/2011. The appliance must be fitted with a modification to the secondary air control to ensure that the air supply holes remain 3mm open when the operator has nominally shut the control. | Instruction manual reference “INK.00.7927” dated 20/12/2011. The appliance must be fitted with a modification to the secondary air control to ensure that the air supply holes remain 3mm open when the operator has nominally shut the control. | Wood logs [^f01000]. |
| Meg 5.0 stove and Sirius 600 Inset stove. Manufactured by F.E Robinson, (Hooton) Ltd., Station Works, Hooton Road, Hooton, South Wirral, CH66 7NF. | Instruction manual reference “Manual Version 1.3” dated 27/07/2012. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 10mm open position. | Instruction manual reference “Manual Version 1.3” dated 27/07/2012. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 10mm open position. | Wood logs [^f01000]. |
| MEG 7.5/Sirius 750 and MEG 4.5/Sirius 450. Manufactured by Meg Stoves, F.E. Robinson (Hooton) Ltd., Station Works, Hooton Road, Hooton, South Wirral, CH66 7NF. | Instruction manual reference “Meg Solid Fuel Stoves Manual (107)” dated 28/01/2011. | Instruction manual reference “Meg Solid Fuel Stoves Manual (107)” dated 28/01/2011. | Wood logs [^f01000]. |
| Mendip SE Wood Burning 5kW Space Heating Stove. Manufactured by TR Engineering Ltd., Unit 7, Newton Chambers Way, Thorncliffe Industrial Estate, Chapeltown, Sheffield, S35 2PH. | Instruction manual reference “700273 Iss. 2 Rev. 1” dated January 2012. | Instruction manual reference “700273 Iss. 2 Rev. 1” dated January 2012. | Wood logs [^f01000]. |
| Mendip SE Wood Burning 8kW Space Heating Stove. Manufactured by TR Engineering Ltd., Unit 7, Newton Chambers Way, Thorncliffe Industrial Estate, Chapeltown, Sheffield, S35 2PH. | Instruction manual reference “700275 Iss. 2 Rev. 1” dated January 2012. | Instruction manual reference “700275 Iss. 2 Rev. 1” dated January 2012. | Wood logs [^f01000]. |
| Merlin Midline ST-C and Merlin Slimline ST-D multifuel stoves. Manufactured by Merlin Stoves Ltd., Foregates, Holmer, Hereford, HR4 9RJ. | Installation and Operation Instruction manual reference “MerlinST-C&D_v1” dated 16/07/2013. The appliance must be fitted with a mechanical stop to prevent air control closure beyond the 50mm open position. | Installation and Operation Instruction manual reference “MerlinST-C&D_v1” dated 16/07/2013. The appliance must be fitted with a mechanical stop to prevent air control closure beyond the 50mm open position. | Wood logs [^f01000]. |
| The Mescoli PB50, PB35, PB28. Manufactured by MESCOLI CALDAIE S.rI. Caldaie-Termocucine, Via del Commercio, 285 4 1058 Vignola, (MO) Italy. | Manufacturer’s instruction and installation manual reference “SY315EVO P,C,B-COMBIFIRE 2 PB28/35/50 BOILERS Edition 1.7” dated January 2006. | Manufacturer’s instruction and installation manual reference “SY315EVO P,C,B-COMBIFIRE 2 PB28/35/50 BOILERS Edition 1.7” dated January 2006. | Wood pellets following ÖNORM M7 135 or DIN plus (DIN 51731) [^f01000]. |
| Micromet MEG 7.5 (also known as the Sirius 750); Micromet MEG 4.5 (also known as the Sirius 450). Manufactured by Micromet, 125 Bridge St, Birkenhead, Merseyside, CH41 1BD. | Instruction manual reference “Micromet Solid Fuel Stoves Manual (24)” dated 16/06/2010. | Instruction manual reference “Micromet Solid Fuel Stoves Manual (24)” dated 16/06/2010. | Dry wood logs [^f01000]. |
| Milan Series 4. Manufactured by Chesneys Ltd., 194-200 Battersea Park Road, London, SW11 4ND. | Instruction manual reference “CH4K Milan-V2” dated 18/11/2010. The appliance must be fitted with a system to prevent closure of the air control beyond the 25mm open position. | Instruction manual reference “CH4K Milan-V2” dated 18/11/2010. The appliance must be fitted with a system to prevent closure of the air control beyond the 25mm open position. | Wood logs [^f01000]. |
| Milan Series 6. Manufactured by Chesneys Ltd., 194-200 Battersea Park Road, London, SW11 4ND. | Instruction manual reference “CH6K Milan-V2” dated 18/11/2010. The appliance must be fitted with a system to prevent closure of the air control beyond the 40mm open position. | Instruction manual reference “CH6K Milan-V2” dated 18/11/2010. The appliance must be fitted with a system to prevent closure of the air control beyond the 40mm open position. | Wood logs [^f01000]. |
| Monaco multifuel Stove, Staub Fonderie-Franco Belge model 1340605. Manufactured by Staub Fonderie-Franco Belge, Rue Orphee Variscotte, 59660, Merville, France. | Instruction manual reference “1303 - 1” dated 04/05/2010. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond 4mm from closed. | Instruction manual reference “1303 - 1” dated 04/05/2010. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond 4mm from closed. | Wood logs [^f01000]. |
| Mondo 1, Mondo 2 and Mondo Petite stoves. Manufactured by Lotus Heating Systems A/S, Agertoften 6, 5550 Langeskov, Denmark. | Instruction manual reference “Lotus-Mondo Series Stoves Version 1” dated 15/10/2012. The appliance must be fitted with a mechanical stop to prevent closure of the air dampers beyond the 8mm open position. | Instruction manual reference “Lotus-Mondo Series Stoves Version 1” dated 15/10/2012. The appliance must be fitted with a mechanical stop to prevent closure of the air dampers beyond the 8mm open position. | Wood logs [^f01000]. |
| Morsø-Ø4. Manufactured by Morsø Jernstoberi A/S, DK-7900 Nykobing, Mors, Denmark. | Instruction manual reference “Ø- Collection” dated 01/02/2010 and instruction manual reference “72000400” dated 01/02/2010. Applies to units manufactured after 01/02/2010. | Instruction manual reference “Ø- Collection” dated 01/02/2010 and instruction manual reference “72000400” dated 01/02/2010. Applies to units manufactured after 01/02/2010. | Wood logs [^f01000]. |
Reading this document does not replace reading the official text published on legislation.gov.uk. Contains public sector information licensed under the Open Government Licence v3.0. We assume no responsibility for any inaccuracies arising from the conversion of the original CLML XML to this format.
This text is published under legislation.gov.uk's own terms of reuse, not a Legalize or public-domain licence.
legislation.gov.uk
Open Government Licence v3.0 (attribution required)
© Crown and database right. Derived from content available under the Open Government Licence v3.0 from legislation.gov.uk.