The Smoke Control Areas (Exempted Classes of Fireplace) (Wales) Order 2016
| Class of fireplace | Conditions | Conditions | Conditions |
|---|---|---|---|
| Saltfire ST2, Fireglow ST2, & Ultimo ST2 Wood Burning Stove. Manufactured by Saltfire Stoves Ltd, Station Works, Johns Road, Wareham, BH20 4BG. | Installation and Operating Instructions reference “Saltfire ST2, A.K.A Fireglow ST2, A.K.A. Ultimo ST2, Manual Version 1.1” dated 22nd January 2014. The appliance must be fitted with a mechanical stop to prevent air wash control closure beyond the 7mm open position and a stop to prevent tertiary air control closure beyond the 20% open position. | Installation and Operating Instructions reference “Saltfire ST2, A.K.A Fireglow ST2, A.K.A. Ultimo ST2, Manual Version 1.1” dated 22nd January 2014. The appliance must be fitted with a mechanical stop to prevent air wash control closure beyond the 7mm open position and a stop to prevent tertiary air control closure beyond the 20% open position. | Wood logs ⁽¹⁾. |
| Saltfire Sturminster Inset wood-burning stove. Manufactured by Saltfire Stoves Ltd., Station Works, Johns Road, Wareham, BH20 4BG. | Installation and Operating Instruction manual reference “Saltfire Sturminster Manual 1.0” dated 4th July 2013. | Installation and Operating Instruction manual reference “Saltfire Sturminster Manual 1.0” dated 4th July 2013. | Wood logs ⁽¹⁾. |
| San Remo 4SE stove. Manufactured by Heat Design, 30 Hawthorn Road, Western Industrial Estate, Naas Road, Dublin 12, Ireland. | Instruction manual reference “SR468SE” dated 25th July 2012. The appliance must be fitted with a system to prevent closure of the secondary air control beyond 5mm open. | Instruction manual reference “SR468SE” dated 25th July 2012. The appliance must be fitted with a system to prevent closure of the secondary air control beyond 5mm open. | Wood logs ⁽¹⁾. |
| San Remo 6SE stove. Manufactured by Heat Design, 30 Hawthorn Road, Western Industrial Estate, Naas Road, Dublin 12, Ireland. | Instruction manual reference “SR468SE” dated 25th July 2012. The appliance must be fitted with a system to prevent closure of the secondary air control beyond 75% from closed. | Instruction manual reference “SR468SE” dated 25th July 2012. The appliance must be fitted with a system to prevent closure of the secondary air control beyond 75% from closed. | Wood logs ⁽¹⁾. |
| San Remo 8SE stove. Manufactured by Heat Design, 30 Hawthorn Road, Western Industrial Estate, Naas Road, Dublin 12, Ireland. | Instruction manual reference “SR468SE” dated 25th July 2012. The appliance must be fitted with a system to prevent closure of the secondary air control beyond 25% from closed. | Instruction manual reference “SR468SE” dated 25th July 2012. The appliance must be fitted with a system to prevent closure of the secondary air control beyond 25% from closed. | Wood logs ⁽¹⁾. |
| San Remo SR5i Multi-fuel inset stove. Manufactured by Heat Design Ltd., 30 Hawthorn Road, Western Industrial Estate, Naas Road, Dublin 12, Ireland. | Installation and Operating Instruction manual reference “SR5i” dated 2nd May 2013. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 3.5mm open position. | Installation and Operating Instruction manual reference “SR5i” dated 2nd May 2013. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 3.5mm open position. | Wood logs ⁽¹⁾. |
| SASP 1000 675 kW Biomass Boiler when fitted with a multi-cyclone Manufactured by Topling d.o.o. Magistraini put BB, 78430 Prnjavor. The Republic of Srpska, Bosnia and Herzegovina. | Instruction manual assembly and operation manual reference “Version TOP/SASP/V.1.1” dated 12th December 2013. | Instruction manual assembly and operation manual reference “Version TOP/SASP/V.1.1” dated 12th December 2013. | Woodchips of maximum 25% moisture content ⁽¹⁾. |
| Scan Anderson 4-5. Manufactured by Krog Iversen 7 Co., A/S DK-5492 Vissenbjerg, Denmark. | Manufacturer’s instructions entitled “Scan Andersen 4-5” reference “09/05-GB” dated 15th November 2007. The appliance must be fitted with a permanent stop on the secondary air inlet to prevent closure beyond 20mm. | Manufacturer’s instructions entitled “Scan Andersen 4-5” reference “09/05-GB” dated 15th November 2007. The appliance must be fitted with a permanent stop on the secondary air inlet to prevent closure beyond 20mm. | Untreated dry wood ⁽¹⁾. |
| Scan Andersen 8-2 wood-burning 7 kW stove Manufactured by Jøtul A.S, P.O. Box 1411, N-1602 Fredrikstad, Norway. | Installation and operating instructions manual reference “10026402 -P01” dated October 2012 and addendum to installation and operating instructions manual reference “SMOKEA8-2” dated 5th June 2014. The appliance must be fitted with Smoke control kit SMOKEA8-2 to prevent closure of the air control beyond 25% open. | Installation and operating instructions manual reference “10026402 -P01” dated October 2012 and addendum to installation and operating instructions manual reference “SMOKEA8-2” dated 5th June 2014. The appliance must be fitted with Smoke control kit SMOKEA8-2 to prevent closure of the air control beyond 25% open. | Wood logs ⁽¹⁾. |
| Scan 58-1, Scan 58-1 Wall; Scan 58-2, Scan 58-2 Wall; Scan 58-3, Scan 58-3 Wall; Scan 58-4, Scan 58-4 Wall; Scan 58-5, Scan 58-5 Wall; Scan 58-6, Scan 58-6 Wall; Scan 58-7, Scan 58-7 High Top; Scan 58-8, Scan 58-8 High Top; Scan 58-9, Scan 58-9 High Top; Scan 58-10, Scan 58-10 High Top. Manufactured by Scan A/S, Glasvænget 3-9, 5492 Vissenbjerg, Denmark. | Instruction manual reference “GB 90358500-5” dated 24th March 2011 and supplementary instructions for UK Smoke Control Areas reference “SCAN58SCA” dated 1st March 2013. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 1/3rd open position. | Instruction manual reference “GB 90358500-5” dated 24th March 2011 and supplementary instructions for UK Smoke Control Areas reference “SCAN58SCA” dated 1st March 2013. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 1/3rd open position. | Wood logs ⁽¹⁾. |
| Scan 64-1 - with steel sides, Scan 64-2 - with steel sides and side windows, Scan 64-3 - with sides of natural stones/tiles, Scan 64-4 - with sides of natural stone/tile and side windows, Scan 64-7 - with stainless steel sides, Scan 64-8 - with stainless steel sides and side windows wood burning 6 kW Stoves. Manufactured by Scan A/S Glasvænget 3-9 5492 Vissenbjerg, Denmark | Assembly and Instructions manual dated 24.03.2015 reference “GB 90064500” Fitted with a mechanical stop to prevent secondary air control closure beyond the 59% open position. | Assembly and Instructions manual dated 24.03.2015 reference “GB 90064500” Fitted with a mechanical stop to prevent secondary air control closure beyond the 59% open position. | Wood logs ⁽¹⁾. |
| Scan 65-1 6kW wood-burning stove with sheet steel panels and top plate Scan 65-2 6kW wood-burning stove with side windows Scan 65-3 6kW wood-burning stove Clad with stone slabs Scan 65-4 - 6kW wood-burning stove clad with stone slabs and side windows Scan 65-5 – 6kW wood-burning stove with extended top and baking compartment Scan 65-6 - 6kW wood-burning stove with extended top and baking compartment and side windows Scan 65-7 – 6kW wood-burning stove with high stone clad and extended top Scan 65-8 - 6kW wood-burning stove with high stone clad and extended top and side windows Scan 65-9 - 6kW wood-burning stove with high sheet steel and extended top Scan 65-10 - 6kW wood-burning stove with high sheet steel and extended top and side windows. Manufactured by Scan A/S Glasvænget 3-9 5492 Vissenbjerg, Denmark | Assembly and Instructions manual dated 21/08/2015 reference “GB 90065500”. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 59% open position | Assembly and Instructions manual dated 21/08/2015 reference “GB 90065500”. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 59% open position | Wood logs⁽¹⁾. |
| Scan 66-1, 66-3, 66-4 stoves Manufactured by Scan A/S, Glasvaenget 3-9, 5492 Vissenbjerg, Denmark. | Assembly and instructions manual reference “GB 90066500” dated 27th October 2014. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 35mm open position. | Assembly and instructions manual reference “GB 90066500” dated 27th October 2014. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 35mm open position. | Wood logs ⁽¹⁾. |
| Scan 83-1 stove, Scan 83-2 stove, Scan 83-3 Maxi stove, Scan 83-4 Maxi stove, Scan 83-5 stove, Scan 83-6 stove, Scan 83-7 Maxi stove, Scan 83-8 Maxi stove. Manufactured by Scan A/S, Glasvaenget 3-9, 5492 Vissenbjerg, Denmark. | Instruction manual reference “UK 90583500” dated 15th January 2014. | Instruction manual reference “UK 90583500” dated 15th January 2014. | Wood logs ⁽¹⁾. |
| Scan DSA 7-5 wood-burning Inset roomheater. Manufactured by Scan A/S, Glasvænget 3-9, 5492 Vissenbjerg, Denmark. | Instruction manual “Instructions for installation and use: SCAN DSA 6 & DSA 7-5” reference “Edition 17.09.2010 – GB”, supplement “DSA 7-5 – UK smoke control areas” reference “DSA 7-5 SMOKE” dated 1st January 2012 and instructions for installation (including directions for use and stoking) reference “Edition 05.10.2010 – GB” dated 5th October 2010. The appliance must be fitted with a mechanical stop to prevent closure of the air wash control lever beyond the 50% open position. | Instruction manual “Instructions for installation and use: SCAN DSA 6 & DSA 7-5” reference “Edition 17.09.2010 – GB”, supplement “DSA 7-5 – UK smoke control areas” reference “DSA 7-5 SMOKE” dated 1st January 2012 and instructions for installation (including directions for use and stoking) reference “Edition 05.10.2010 – GB” dated 5th October 2010. The appliance must be fitted with a mechanical stop to prevent closure of the air wash control lever beyond the 50% open position. | Wood logs ⁽¹⁾. |
| Scan ILD 7 and ILD 8 wood-burning stoves Manufactured by Color Emajl d.o.o. Alaginci 87/a, HR-34000 Pozega, Croatia. | Instruction manual reference “Manual version. No. 13-1 GB 01.07.13” dated 1st July 2013. The appliance must be fitted with a permanent stop to fix the secondary air control 7.5% open in the fully closed position. | Instruction manual reference “Manual version. No. 13-1 GB 01.07.13” dated 1st July 2013. The appliance must be fitted with a permanent stop to fix the secondary air control 7.5% open in the fully closed position. | Wood logs ⁽¹⁾. |
| Scandian 5MF Traditional, Scandian 5MF Modern, Scandian 8MF Traditional and Scandian 8MF Modern multifuel stoves. Manufactured by Capital Fireplaces Ltd., 12-17 Henlow Trading Estate, Henlow Camp, Hitchin, SG16 6DS. | Installation and operating instructions manual reference “Scandian MF&WD Version 1” dated June 2013. The appliance must be fitted with the manufacturer’s smoke control kit. | Installation and operating instructions manual reference “Scandian MF&WD Version 1” dated June 2013. The appliance must be fitted with the manufacturer’s smoke control kit. | Wood logs ⁽¹⁾. |
| Scandian 5WD Traditional and Scandian 5WD Modern wood-burning stoves. Manufactured by Capital Fireplaces Ltd., 12-17 Henlow Trading Estate, Henlow Camp, Hitchin, SG16 6DS. | Installation and operating instructions manual reference “Scandian MF&WD Version 1” dated June 2013. | Installation and operating instructions manual reference “Scandian MF&WD Version 1” dated June 2013. | Wood logs ⁽¹⁾. |
| Scandian 8WD Traditional and Scandian 8WD Modern wood-burning stoves. Manufactured by Capital Fireplaces Ltd., 12-17 Henlow Trading Estate, Henlow Camp, Hitchin, SG16 6DS. | Installation and operating instructions manual reference “Scandian MF&WD Version 1” dated June 2013. The appliance must be fitted with the manufacturer’s smoke control kit. | Installation and operating instructions manual reference “Scandian MF&WD Version 1” dated June 2013. The appliance must be fitted with the manufacturer’s smoke control kit. | Wood logs ⁽¹⁾. |
| Schmid UTSK 180, 240, 300, 360, 450, 550, 700, 900, 1200, 1600kW. Manufactured by Schmid AG Woodfiring Systems, PO Box 42, CH-8380 Eschikon, Switzerland. | Manufacturer’s instruction manual reference “UTSK-ABC.22-AME-S-PPU” dated 25/09/2008 (where ABC is model number i.e. 180, 240, 300, 360, 450, 550, 700, 900, 1200, 1600). | Manufacturer’s instruction manual reference “UTSK-ABC.22-AME-S-PPU” dated 25/09/2008 (where ABC is model number i.e. 180, 240, 300, 360, 450, 550, 700, 900, 1200, 1600). | Wood pellets or wood chips following CEN/TS 14961:2005⁽¹⁾. |
| Schmid UTSL 30, 40, 50, 65, 80, 110, 150kW. Manufactured by Schmid AG Woodfiring Systems, PO Box 42, CH-8380 Eschikon, Switzerland. | Manufacturer’s instruction manual reference “Operating Manual Wooden Chips and Pellets Plant. Lignumat UTSL” dated 23rd December 2004. | Manufacturer’s instruction manual reference “Operating Manual Wooden Chips and Pellets Plant. Lignumat UTSL” dated 23rd December 2004. | Wood pellets or wood chips following CEN/TS 14961:2005⁽¹⁾. |
| Schmid UTSP 180, 240, 300kW. Manufactured by Schmid AG Woodfiring Systems, PO Box 42, CH-8380 Eschikon, Switzerland. | Manufacturer’s instruction manual reference “UTSK – ABC22-AME-S-PPU” (where ABC is model number i.e. 180, 240, 300) dated 25th September 2008. | Manufacturer’s instruction manual reference “UTSK – ABC22-AME-S-PPU” (where ABC is model number i.e. 180, 240, 300) dated 25th September 2008. | Wood pellets following CEN/TS 14961:2005⁽¹⁾. |
| Schmid UTSR 150, 180, 240, 300, 360, 450, 550, 700, 900kW. Manufactured by Schmid AG Woodfiring Systems, PO Box 42, CH-8380 Eschikon, Switzerland. | Manufacturer’s instruction manual reference “UTSR – ABC22-AME-S-PPV”(where ABC is model number i.e. 150, 180, 240, 300, 360, 450, 550, 700, 900) dated 25th September 2008. | Manufacturer’s instruction manual reference “UTSR – ABC22-AME-S-PPV”(where ABC is model number i.e. 150, 180, 240, 300, 360, 450, 550, 700, 900) dated 25th September 2008. | Wood pellets or wood chips following CEN/TS 14961:2005⁽¹⁾. |
| Schmid UTSR 1200. Manufactured by Schmid AG Energy Solutions, PO Box 42, CH-8380 Eschikon, Switzerland. | Instruction manual reference “60110797.doc” dated 24th April 2012. | Instruction manual reference “60110797.doc” dated 24th April 2012. | Wood chips and wood pellets ⁽¹⁾. |
| Schmid UTSW 900.32. Manufactured by Schmid AG Woodfiring Systems, PO Box 42, CH-8380 Eschikon, Switzerland. | Instruction manual reference “Instruction manual. Wood chip furnace with boiler type Schmid Pyrotroinc Modular issue 1” dated 7th January 2013 and instruction manual reference “PersonalTouch Version 2010 EVO10 V531\PT_2010_C3.” dated 2010. | Instruction manual reference “Instruction manual. Wood chip furnace with boiler type Schmid Pyrotroinc Modular issue 1” dated 7th January 2013 and instruction manual reference “PersonalTouch Version 2010 EVO10 V531\PT_2010_C3.” dated 2010. | Wood chips and wood pellets ⁽¹⁾. |
| Seguin Jade wood-burning stove. Manufactured by Groupe Seguin, Cheminees Seguin Duteriez, Zone Industrielle de Lhérat, 63310 France. | Instruction manual reference “Wood Stoves Manual Installation – Use 1/1/2013 Characteristics of the Stove” dated 1st January 2013. The appliance must be fitted with a permanent stop to prevent closure of the secondary air control beyond the 40% open position. | Instruction manual reference “Wood Stoves Manual Installation – Use 1/1/2013 Characteristics of the Stove” dated 1st January 2013. The appliance must be fitted with a permanent stop to prevent closure of the secondary air control beyond the 40% open position. | Wood logs ⁽¹⁾. |
| Seguin Saphir wood-burning stove. Manufactured by Groupe Seguin, Cheminees Seguin Duteriez, Zone Industrielle de Lhérat, 63310 France. | Instruction manual reference “Wood Stoves Manual Installation – Use 1/1/2013 Characteristics of the Stove” dated 1st January 2013. The appliance must be fitted with a permanent stop to prevent closure of the secondary air control beyond the 15mm open position. | Instruction manual reference “Wood Stoves Manual Installation – Use 1/1/2013 Characteristics of the Stove” dated 1st January 2013. The appliance must be fitted with a permanent stop to prevent closure of the secondary air control beyond the 15mm open position. | Wood logs ⁽¹⁾. |
| Senza UK w/o sideglass and Senza UK w/ sideglass 5kW wood burning stoves Manufactured by Jydepejsen A/S, Ahornsvinget 3-7, Nr. Felding, DK-7500 Holstebro, Denmark. | Instruction manual reference “User’s manual Revision 1, 27.11.2014” dated 27th November 2014. The appliance must be fitted with a modification to fix the secondary air control to 1300mm² in its minimum position. | Instruction manual reference “User’s manual Revision 1, 27.11.2014” dated 27th November 2014. The appliance must be fitted with a modification to fix the secondary air control to 1300mm² in its minimum position. | Wood logs ⁽¹⁾. |
| Serenity 40 FS, Serenity 40 LS and Serenity 40 FW stoves. Manufactured by Pevex Enterprises Ltd., Unit 16, Seven Acres Business Park, Newbourne Road, Waldringfield, Nr Woodbridge, IP12 4PS. | Instruction manual reference “Pevex1014/AH/ver1” dated January 2013. The appliance must be fitted with permanent stops that ensure the secondary and tertiary air controls do not close beyond 1.1cm open and 2cm open positions respectively. | Instruction manual reference “Pevex1014/AH/ver1” dated January 2013. The appliance must be fitted with permanent stops that ensure the secondary and tertiary air controls do not close beyond 1.1cm open and 2cm open positions respectively. | Wood logs ⁽¹⁾. |
| Serenity 45, 5.5kW multifuel inset roomheater. Manufactured by Pevex Enterprises Ltd, Unit MP7, Kirrawah Business Park, Newbourne Road, Nr Woodbridge, IP12 4PR | Installation and Operating Instructions for Serenity 45 inset dated June 2015 reference “Pevex1030/AH/ver1” The appliance must be fitted with a permanent stop that ensures the air control cannot close beyond 19mm open (position 2). | Installation and Operating Instructions for Serenity 45 inset dated June 2015 reference “Pevex1030/AH/ver1” The appliance must be fitted with a permanent stop that ensures the air control cannot close beyond 19mm open (position 2). | Wood Logs ⁽¹⁾. |
| Serenity 50FS, Serenity 50LS, Serenity 50FW, Serenity 50 Ped and Serenity 50 Inset stoves. Manufactured by Pevex Enterprises Ltd., Unit 16, Seven Acres Business Park, Newbourne Road, Waldringfield, Nr Woodbridge, IP12 4PS. | Instruction manual reference “Pevex1014/AH/ver1” dated January 2013. The secondary air slider must have a built in stop to prevent the slider from being shut off completely and remains open by 40% of its full travel. The tertiary air control must not have a slider and it must be factory designed with a 2cm open slot that remains 100% open. | Instruction manual reference “Pevex1014/AH/ver1” dated January 2013. The secondary air slider must have a built in stop to prevent the slider from being shut off completely and remains open by 40% of its full travel. The tertiary air control must not have a slider and it must be factory designed with a 2cm open slot that remains 100% open. | Wood logs ⁽¹⁾. |
| Serrano 5, York Midi; Monterrey 6 Stoves. Manufactured by Broseley Ltd., Knights Way, Battlefield Enterprise Park, Shrewsbury, Shropshire, SY1 3AB. | Instruction manual reference “09TJD” dated January 2010. The appliance must be fitted with a system that prevents the closure of the secondary air flaps to less than 8mm open position. | Instruction manual reference “09TJD” dated January 2010. The appliance must be fitted with a system that prevents the closure of the secondary air flaps to less than 8mm open position. | Wood logs ⁽¹⁾. |
| Serrano 5 Multi Fuel and Monterrey 6 Multi Fuel Stoves. Manufactured by Broseley Fires Ltd., Knights Way, Battlefield Enterprise Park, Shrewsbury, Shropshire, SY1 3AB. | Instruction manual reference “TJ09C” dated 21st December 2009. The appliance must be fitted with a system that prevents the closure of the secondary air flaps to less than 8mm open position. | Instruction manual reference “TJ09C” dated 21st December 2009. The appliance must be fitted with a system that prevents the closure of the secondary air flaps to less than 8mm open position. | Wood logs ⁽¹⁾. |
| Serrano 7 Multi Fuel stove. Manufactured by Broseley Fires Ltd., Knights Way, Battlefield Enterprise Park, Shrewsbury, Shropshire, SY1 3AB. | Instruction manual reference “TJ09C” dated 21st December 2009. The appliance must be fitted with a system that prevents the closure of the secondary air flaps to less than 10mm open position. | Instruction manual reference “TJ09C” dated 21st December 2009. The appliance must be fitted with a system that prevents the closure of the secondary air flaps to less than 10mm open position. | Wood logs ⁽¹⁾. |
| Sherborne SE NS-3C, Chesham SE NS-3B, Burford SE NS-3A 4.9kW multi-fuel stoves. Manufactured by Newman Fireplaces Ltd Units 6 & 7 Rawreth Barns, Dollymans Farm, Doublegate Lane, Rawreth, Wickford, Essex, SS11 8UD | Installation and user instruction manual dated 4th June 2014, reference “ NS-3A - NS-3B - NS-3C “ The appliance must be fitted with mechanical stops to prevent closure of the secondary air control beyond the 30% open position | Installation and user instruction manual dated 4th June 2014, reference “ NS-3A - NS-3B - NS-3C “ The appliance must be fitted with mechanical stops to prevent closure of the secondary air control beyond the 30% open position | Wood logs ⁽¹⁾. |
| Short Penguin and Penguin 8 multifuel stoves. Manufactured by Chilli Penguin Stoves Limited, Castell Bach, Mynydd Nefyn, Pwllheli, LL53 6TL. | Instruction manual reference “Penguin Manual Version 1 Issue 1” dated 17th December 2013. The appliance must be fitted with a modification to fix the secondary air control to 1cm open in the fully closed position. | Instruction manual reference “Penguin Manual Version 1 Issue 1” dated 17th December 2013. The appliance must be fitted with a modification to fix the secondary air control to 1cm open in the fully closed position. | Wood logs ⁽¹⁾. |
| SHT TDA Thermodual 15 and 25 log and pellet burning boilers. Manufactured by Lohberger Heiztechnik GmbH, Rechtes Salzachufer 40, A-5020 Salzburg, Austria. | Installation servicing instructions reference “In1233 Edition 1a” dated January 2014, operating instructions reference “M21/HB M27/GB” dated 28th January 2014 and supplementary installation instructions reference “IN1241 Edition 1a” dated January 2014. | Installation servicing instructions reference “In1233 Edition 1a” dated January 2014, operating instructions reference “M21/HB M27/GB” dated 28th January 2014 and supplementary installation instructions reference “IN1241 Edition 1a” dated January 2014. | Wood logs or wood pellets ⁽¹⁾. |
| SHT TDA Thermodual 30 and 40 log and pellet burning boilers. Manufactured by Lohberger Heiztechnik GmbH, Rechtes Salzachufer 40, A-5020 Salzburg, Austria. | Installation servicing instructions reference “In2015 Edition 1” dated January 2014, operating instructions reference “M21/HB M27/GB dated 28th January 2014 and supplementary installation instructions reference “IN1241 Edition 1a” dated January 2014. | Installation servicing instructions reference “In2015 Edition 1” dated January 2014, operating instructions reference “M21/HB M27/GB dated 28th January 2014 and supplementary installation instructions reference “IN1241 Edition 1a” dated January 2014. | Wood logs or wood pellets ⁽¹⁾. |
| Sigma UK 7kW inset roomheater. Manufactured by Jydepejsen A/S, Ahornsvinget 3-7, Nr. Felding, DK-7500 Holstebro, Denmark | User’s manual dated March 2015 reference “Sigma & Sigma Titan. User’s manual. Revision 1, 25.03.2015” The appliance must be fitted with a mechanical stop to prevent closure of the air control valve beyond the 28% open position | User’s manual dated March 2015 reference “Sigma & Sigma Titan. User’s manual. Revision 1, 25.03.2015” The appliance must be fitted with a mechanical stop to prevent closure of the air control valve beyond the 28% open position | Wood logs⁽¹⁾. |
| Silverdale 5SE, Amalia 5, Oppdal 5 and Hestia 5 multifuel stoves Manufactured by Broseley Fires, Knights Way, Battlefield Enterprise Park, Shrewsbury, SY1 3AB. NB: these are the same as the wood burning versions, with an alternative grate to allow use of other authorised fuels. | Instruction manual reference “GB14A-issue 5” dated December 2014. The appliance must be fitted with a permanent stop to fix the secondary air slide at a minimum of 23mm open. | Instruction manual reference “GB14A-issue 5” dated December 2014. The appliance must be fitted with a permanent stop to fix the secondary air slide at a minimum of 23mm open. | Wood logs ⁽¹⁾. |
| Silverdale 7SE, Amalia 7, Oppdal 7 and Hestia 7 multifuel stoves Manufactured by Broseley Fires, Knights Way, Battlefield Enterprise Park, Shrewsbury, SY1 3AB. NB: these are the same as the wood burning versions, with an alternative grate to allow use of other authorised fuels. | Instruction manual reference “GB14A-issue 5” dated December 2014. The appliance must be fitted with a permanent stop to fix the secondary air slide at a minimum of 50mm open. | Instruction manual reference “GB14A-issue 5” dated December 2014. The appliance must be fitted with a permanent stop to fix the secondary air slide at a minimum of 50mm open. | Wood logs ⁽¹⁾. |
| Sirius 490 Sigma MF, Sirius 490 Scene MF, Sirius 790 Sigma MF and Sirius 790 Scene MF multifuel stoves. Manufactured by Capital Fireplaces Ltd., 12-17 Henlow Trading Estate, Henlow Camp, Hitchin, SG16 6DS. | Installation and Operating Instructions manual reference “Sirius MF&WD Version 1” dated May 2013. The appliance must be fitted with the manufacturer’s smoke control kit. | Installation and Operating Instructions manual reference “Sirius MF&WD Version 1” dated May 2013. The appliance must be fitted with the manufacturer’s smoke control kit. | Wood logs ⁽¹⁾. |
| Sirius 490 Sigma WD and Sirius 490 Scene WD wood-burning stoves. Manufactured by Capital Fireplaces Ltd., 12-17 Henlow Trading Estate, Henlow Camp, Hitchin, SG16 6DS. | Installation and operating Instructions manual reference “Sirius MF&WD Version 1” dated May 2013. | Installation and operating Instructions manual reference “Sirius MF&WD Version 1” dated May 2013. | Wood logs ⁽¹⁾. |
| Sirius 790 Sigma WD and Sirius 790 Scene WD wood-burning stoves. Manufactured by Capital Fireplaces Ltd., 12-17 Henlow Trading Estate, Henlow Camp, Hitchin, SG16 6DS. | Installation and operating instructions manual reference “Sirius MF&WD Version 1” dated May 2013. The appliance must be fitted with the manufacturer’s smoke control kit. | Installation and operating instructions manual reference “Sirius MF&WD Version 1” dated May 2013. The appliance must be fitted with the manufacturer’s smoke control kit. | Wood logs ⁽¹⁾. |
| Sirius Imperial, Principal, Qadrical,& Essence 4.9kW multifuel stoves. Manufactured by Capital Fireplaces Ltd, Units 12-17, Henlow Trading Estate, Henlow Camp, SG16 6DS | Installation & Operating Instructions dated 26th June 2015 reference “15JUN08/EQIP/V1.3” Fitted with a mechanical stop to prevent secondary air control closure beyond the 50% open position. | Installation & Operating Instructions dated 26th June 2015 reference “15JUN08/EQIP/V1.3” Fitted with a mechanical stop to prevent secondary air control closure beyond the 50% open position. | Wood logs ⁽¹⁾. |
| Sirius Traditional Stove. Manufactured by Tianjin Focus Arts & Crafts Co, Industrial Area Gao Zhuangzi Village, Xin Zhuang Town, Jin Nan District, Tianjin, P.R. China 300350. | Instruction and operating instruction manual reference “v173 of 09/11/2010” dated 9th November 2010. | Instruction and operating instruction manual reference “v173 of 09/11/2010” dated 9th November 2010. | Wood logs ⁽¹⁾. |
| Smart 150, Smart 199, Smart 250, Smart 300, Smart 350, Smart 400, Smart 450 and Smart 500 boilers all fitted with cyclones. Manufactured by Smart Heating Technology s.r.o, U Statku 653/24, 717 00 Ostrava-Bartovice, Czech Republic. | Operation manual reference “BO4CD35 Issue No: 02” dated January 2014. | Operation manual reference “BO4CD35 Issue No: 02” dated January 2014. | 6mm wood pellets or 30mm wood chips at maximum 30% moisture ⁽¹⁾. |
| Spartherm Arte U-50h – P3, U-90h – P3 and U-70h – P3 insert stoves Manufactured by Spartherm Feuerungstechnik GmbH Maschweg 38, Melle, Germany. | Instruction manual reference “Version 06/2014” dated June 2014. | Instruction manual reference “Version 06/2014” dated June 2014. | Wood logs ⁽¹⁾. |
| Spartherm Linear Cassette XS500-P3 insert stove Manufactured by Spartherm Feuerungstechnik GmbH Maschweg 38, Melle, Germany. | Instruction manual reference “Version 06/2014” dated June 2014. | Instruction manual reference “Version 06/2014” dated June 2014. | Wood logs ⁽¹⁾. |
| Spartherm Linear cassette model S 600 P3 inset stove. Manufactured by Spartherm Feuerungstechnik GmbH, Maschweg 38,Melle, Germany. | Installation and operating instructions reference “Spatherm_AA_BA_Kaminkassette_Linear_GB_Stand 01-2014” dated January 2014. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 25% open position. | Installation and operating instructions reference “Spatherm_AA_BA_Kaminkassette_Linear_GB_Stand 01-2014” dated January 2014. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 25% open position. | Dry wood logs ⁽¹⁾. |
| Spartherm Mini 2LRh-4S P3, Mini 2L-4S P3 and Mini 2R-4S P3 wood-burning inset roomheaters Manufactured by Spartherm Feuerungstechnik GmbH Maschweg 38, Melle, 49324, Germany. | Instruction manual reference “Instruction Manual Fireplace Inserts Version 06/2014” dated June 2014. The appliance must be fitted with a system to prevent closure of the air controls beyond the 3mm open position. | Instruction manual reference “Instruction Manual Fireplace Inserts Version 06/2014” dated June 2014. The appliance must be fitted with a system to prevent closure of the air controls beyond the 3mm open position. | Wood logs ⁽¹⁾. |
| Spartherm Passo S-P3, Spartherm Passo M-P3 and Spartherm Passo L-P3 10kW wood-burning stoves. Manufactured by Spartherm Feuerungstechnik GmbH, Maschweg 38, D-49324 Melle, Germany | Installation and Operating instructions for Stoves Selection manual dated July 2015 reference “Version 07/2015” A permanent stop must be in place on the secondary air inlet to prevent closure beyond the 3mm open position | Installation and Operating instructions for Stoves Selection manual dated July 2015 reference “Version 07/2015” A permanent stop must be in place on the secondary air inlet to prevent closure beyond the 3mm open position | Wood logs ⁽¹⁾. |
| Spartherm Stovo S, M, & L Wood burning stoves. Manufactured by Spartherm, Feuerungstechnik GmbH, Maschweg 38, Melle, Germany. | Installation and operating instructions reference “Version 07/2013” dated July 2013. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 13% open position. | Installation and operating instructions reference “Version 07/2013” dated July 2013. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 13% open position. | Wood logs ⁽¹⁾. |
| Spatherm Varia ASh2L – P3, Varia ASh2R – p3, Varia ASh2LX – P3, Varia Ash2R X – P3 wood burning inset roomheaters. Manufactured by Spatherm Feuerungstechnik GmbH, Maschweg 38, D-49324 Melle, Germany. | Instruction manual reference ‘Instruction Manual Fireplace Inserts Version 06/2014’ dated June 2014. A system to prevent closure of the air controls beyond the 7mm open position must be implemented. | Instruction manual reference ‘Instruction Manual Fireplace Inserts Version 06/2014’ dated June 2014. A system to prevent closure of the air controls beyond the 7mm open position must be implemented. | Wood logs ⁽¹⁾. |
| Stockton 3 flat top (product code 7118), Stockton 4 flat top (product code 7101 and 7102), Stockton 5 flat top (product code 7127), Stockton 5 midline (product code 7130), Stockton 6 flat top (product codes 7100 and 7162), Stockton 6 Highline (product code 7117), and Stockton 7 flat top (product codes 7120 and 7163). Manufactured by Stovax Ltd., Falcon Road, Sowton Industrial Estate, Exeter, Devon, EX2 7LF. | Instruction manual reference “PM227 ENG Issue 2” dated July 2008 and instruction manual reference “PM271 Issue 2” dated January 2009. The appliance must be fitted with a permanent stop on the secondary air inlet to prevent closure beyond the 50% open position. | Instruction manual reference “PM227 ENG Issue 2” dated July 2008 and instruction manual reference “PM271 Issue 2” dated January 2009. The appliance must be fitted with a permanent stop on the secondary air inlet to prevent closure beyond the 50% open position. | Untreated dry wood ⁽¹⁾. |
| Stockton 5 flat top (model number 7119), Stockton 5 Canopy (model number 7160), and Stockton 5 Midline (model number 7133). Manufactured by Stovax Ltd., Falcon Road, Sowton Industrial Estate, Exeter, Devon, EX2 7LF. | Manufacturer’s instructions reference “PM176 – issue 4”. The appliance must be fitted with a permanent stop on the secondary air inlet to prevent closure beyond the 50% open position. | Manufacturer’s instructions reference “PM176 – issue 4”. The appliance must be fitted with a permanent stop on the secondary air inlet to prevent closure beyond the 50% open position. | Untreated dry wood ⁽¹⁾. |
| Stockton 7 Inset Convector (product codes 7125F and 7125C). Manufactured by Stovax Ltd., Falcon Road, Sowton Industrial Estate, Exeter, Devon, EX2 7LF. | Manufacturer’s instruction manual reference “PM230 Issue 1” dated May 2008 and instruction manual reference “PM281 Issue 1” dated January 2009. The appliance must be fitted with a permanent stop on the secondary air inlet to prevent closure beyond the 50% open position. | Manufacturer’s instruction manual reference “PM230 Issue 1” dated May 2008 and instruction manual reference “PM281 Issue 1” dated January 2009. The appliance must be fitted with a permanent stop on the secondary air inlet to prevent closure beyond the 50% open position. | Untreated dry wood ⁽¹⁾. |
| Stockton Milner (4.6kW) inset stove – smoke control version. Manufactured by Stovax Ltd., Falcon Road, Sowton Industrial Estate, Exeter, Devon, EX2 7LF. | Instruction manual reference “PM416 Issue 1” dated June 2010 and smoke control kit instruction manual reference “PM501 Issue 1” dated June 2010. The appliance must be fitted with a permanent stop to prevent closure of the secondary air control below the 50% open position. | Instruction manual reference “PM416 Issue 1” dated June 2010 and smoke control kit instruction manual reference “PM501 Issue 1” dated June 2010. The appliance must be fitted with a permanent stop to prevent closure of the secondary air control below the 50% open position. | Wood logs ⁽¹⁾. |
| The Stone Bake Oven Company Mezzo 76 Go and Mezzo 76 Kit wood-burning pizza ovens. Manufactured by Gozney Ltd, Units 18 & 19, Radar Way, Christchurch Business Park, The Runway, Christchurch, BH23 4JE. | Oven Assembly and Operation Manual dated May 2015 reference “Mezzo_Oven_Manual/Version 1.1” | Oven Assembly and Operation Manual dated May 2015 reference “Mezzo_Oven_Manual/Version 1.1” | Wood logs⁽¹⁾. |
| The Stone Bake Oven Company Vento 100 wood-burning pizza ovens. Manufactured by Gozney Ltd, Units 18 & 19, Radar Way, Christchurch Business Park, The Runway, Christchurch, BH23 4JE. | Vento 100 Oven Assembly and Operation Manual dated May 2015 reference “Vento_Oven_Manual/Version 1.1” | Vento 100 Oven Assembly and Operation Manual dated May 2015 reference “Vento_Oven_Manual/Version 1.1” | Wood logs ⁽¹⁾. |
| The Stone Bake Oven Company Gusto 120 wood-burning pizza ovens. Manufactured by Gozney Ltd, Units 18 & 19, Radar Way, Christchurch Business Park, The Runway, Christchurch, BH23 4JE. | Gusto 120 Oven Assembly and Operation Manual dated May 2015 reference “Gusto_Oven_Manual/Version 1.1” | Gusto 120 Oven Assembly and Operation Manual dated May 2015 reference “Gusto_Oven_Manual/Version 1.1” | Wood logs ⁽¹⁾. |
| Stoven Mayfair SE & Stoven Kensington SE 5kW Wood Burning Stoves. Manufactured by Ciang Stoves Ltd., South Chuangye Road, (Hanling Industrial Estate), Beiguan Section, Anyang City, Henan Provence, China 455000. | Instruction manual reference “3-4” dated 27th November 2011. The appliance must be fitted with mechanical stops to prevent closure of the secondary air control beyond the 25% open position and the tertiary air beyond the 1mm open position. | Instruction manual reference “3-4” dated 27th November 2011. The appliance must be fitted with mechanical stops to prevent closure of the secondary air control beyond the 25% open position and the tertiary air beyond the 1mm open position. | Wood logs ⁽¹⁾. |
| Stovo S-plus – P3 and Stovo L-plus – P3 4.7kW wood burning stoves. Manufactured by Spartherm Feuerungstechnik GmbH Maschweg 38, 49324 Melle Germany | Installation and Operating instructions for Stoves Selection manual dated July 2015 reference “Version 07/2015” The appliance must be fitted with a mechanical stop to prevent closure of the air control beyond the 5mm open position | Installation and Operating instructions for Stoves Selection manual dated July 2015 reference “Version 07/2015” The appliance must be fitted with a mechanical stop to prevent closure of the air control beyond the 5mm open position | Wood Logs ⁽¹⁾. |
| Strebel Biotec 25 and 40 boilers Manufactured by Topling d.o.o. Magistralni put BB, 78430 Prnjavor, The Republic of Srpska, Bosnia and Herzegovina. | Instruction manual reference “Version BIOTEC 122013” dated December 2013. | Instruction manual reference “Version BIOTEC 122013” dated December 2013. | Wood pellets ⁽¹⁾. |
| Strebel SRP TR 90, 90kW output pellet boiler. Manufactured by Strebel Ltd., 1F Albany Park Industrial Estate, Frimley Road, Camberley, Surrey, GU15 7P. | Installation manual reference “Installation and operation instructions for special pellet-furnace version 09:2010”. | Installation manual reference “Installation and operation instructions for special pellet-furnace version 09:2010”. | 6mm diameter wood pellets ⁽¹⁾. |
| Strebel Taurus XL 145, Strebel Taurus XL 190, Strebel Taurus XL 240 and Strebel Taurus XL 290 boilers. Manufactured by KSM Stoker, Naessundvej 440, 7960 Karby, Denmark. | Instruction manual reference “Manual Version XL145 to 290” dated December 2013. | Instruction manual reference “Manual Version XL145 to 290” dated December 2013. | Wood pellets and wood chips ⁽¹⁾. |
| Stretton Insert Smoke Exempt Wood Fuel Stove (Stretton Stove SE). Manufactured by Aga, Station Road, Ketley Telford, Shropshire, TF1 5AQ. | Instruction manual reference “N00530AXX REV:001” dated 12th July 2011. | Instruction manual reference “N00530AXX REV:001” dated 12th July 2011. | Dry wood logs ⁽¹⁾. |
| STU 195 and STU 975. Manufactured by Hoval Ltd., Northgate, Newark, Nottinghamshire, NG24 1JN. | Instruction manual reference “Installation, Operation and Maintenance Instructions. STU wood-pellet fired hot water boiler skid assembly STUman CAA (SM)” dated May 2011. | Instruction manual reference “Installation, Operation and Maintenance Instructions. STU wood-pellet fired hot water boiler skid assembly STUman CAA (SM)” dated May 2011. | Wood pellets ⁽¹⁾. |
| Stûv Micromega 11kW Wood-Burning Stove. Manufactured by Stûv SA Rue Jules Borbouse 4, 5170 Bois-de-Villers, Belgium | Directions for use Stûv μM manual dated September 2015 reference “SN 122141” Fitted with a mechanical stop to prevent air control closure beyond the 28% open position | Directions for use Stûv μM manual dated September 2015 reference “SN 122141” Fitted with a mechanical stop to prevent air control closure beyond the 28% open position | Wood Logs ⁽¹⁾. |
| Stuv 30 Compact H. Manufactured by Stuv Sa, Rue Jules Borbouse 4, B-5170 Bois-de-Villers, Belgium. | Instruction manual reference “SN 131766” dated January 2013 and installation instruction manual reference “SN 131766” dated January 2013. The appliance must be fitted with a mechanical stop to prevent air control closure beyond the positions between settings 3 and 4. | Instruction manual reference “SN 131766” dated January 2013 and installation instruction manual reference “SN 131766” dated January 2013. The appliance must be fitted with a mechanical stop to prevent air control closure beyond the positions between settings 3 and 4. | Wood logs ⁽¹⁾. |
| Stuv 30 Compact IN and Stuv 30 Compact R. Manufactured by Stuv Sa, Rue Jules Borbouse 4, B-5170 Bois-de-Villers, Belgium. | Instruction manual reference “SN 112787” dated January 2013 and installation instruction manual reference “112787” dated January 2013. The appliance must be fitted with a mechanical stop to prevent air control closure beyond the positions between settings 3 and 4. | Instruction manual reference “SN 112787” dated January 2013 and installation instruction manual reference “112787” dated January 2013. The appliance must be fitted with a mechanical stop to prevent air control closure beyond the positions between settings 3 and 4. | Wood logs ⁽¹⁾. |
| Stuv 30 Compact. Manufactured by Stuv Sa, Rue Jules Borbouse 4, B-5170 Bois-de-Villers, Belgium. | Instruction manual reference “SN 94770” dated January 2013 and installation instruction manual reference “SN 94770” dated January 2013. The appliance must be fitted with a mechanical stop to prevent air control closure beyond the positions between settings 3 and 4. | Instruction manual reference “SN 94770” dated January 2013 and installation instruction manual reference “SN 94770” dated January 2013. The appliance must be fitted with a mechanical stop to prevent air control closure beyond the positions between settings 3 and 4. | Wood logs ⁽¹⁾. |
| Suprema, Mamy and Italy Hard Top. Manufactured by La Nordica Spa, Via Summano 104 M. Precalcino, 36030, Vicenza, Italy. | Instruction manual reference “7095701 Rev.09” dated 13th December 2010. | Instruction manual reference “7095701 Rev.09” dated 13th December 2010. | Wood logs ⁽¹⁾. |
| Talbott 150-CMH 150kW output Biomass Air Heater. Manufactured by Talbott’s Biomass Energy Systems Ltd., Tollgate Drive, Tollgate Industrial Estate, Stafford, ST16 3HS. | Instruction manual reference “OM-150-CMH version.1” dated January 2011. | Instruction manual reference “OM-150-CMH version.1” dated January 2011. | Softwood, hardwood, medium density fibreboard (MDF) or chipboard offcuts ⁽¹⁾. |
| Talbott’s Automatic Biomass Air Heaters, models T1.5/A, T3/A, T5/A and TM/A. Formerly manufactured by Talbott’s Heating Ltd., and now manufactured by Talbott’s Biomass Energy Systems Ltd., Tollgate Drive, Tollgate Industrial Estate, Stafford, ST16 3HS. | Manufacturer’s instructions reference “T/A JANUARY 1990”. | Manufacturer’s instructions reference “T/A JANUARY 1990”. | Hardwood or softwood shavings or sawdust ⁽¹⁾. |
| Talbott’s Biomass Energy Models C1, C2, C3 and C4. Formerly manufactured by Talbott’s Heating Ltd., and now manufactured by Talbott’s Biomass Energy Systems Ltd., Tollgate Drive, Tollgate Industrial Estate, Stafford, ST16 3HS. | Manufacturer’s instructions reference “Issue C1000/C/Range” dated August 1995. | Manufacturer’s instructions reference “Issue C1000/C/Range” dated August 1995. | Chipboard or wood shavings, forestry chips⁽¹⁾. |
| Talbott’s model T75, T150, T300 Biomass Air Heaters. Formerly manufactured by Talbott’s Heating Ltd., and now manufactured by Talbott’s Biomass Energy Systems Ltd., Tollgate Drive, Tollgate Industrial Estate, Stafford, ST16 3HS. | Manufacturer’s instructions reference “models T75, T150 and T300: “gen/sttech”“ dated 1st January 1995. | Manufacturer’s instructions reference “models T75, T150 and T300: “gen/sttech”“ dated 1st January 1995. | Wood offcuts, wood-waste, pellets, chipboard ⁽¹⁾. |
| Talbott’s T500 Biomass Air heater (afterburn model). Formerly manufactured by Talbott’s Heating Ltd., and now manufactured by Talbott’s Biomass Energy Systems Ltd., Tollgate Drive, Tollgate Industrial Estate, Stafford, ST16 3HS. | Manufacturer’s instructions reference “A10000” dated 1st January 1983. The afterburn cycle must last not less than 25 minutes and must come into operation each time the loading door is opened. | Manufacturer’s instructions reference “A10000” dated 1st January 1983. The afterburn cycle must last not less than 25 minutes and must come into operation each time the loading door is opened. | Wood offcuts, wood-waste, pellets, chipboard ⁽¹⁾. |
| Termatech TT20, TT20Bazic, TT20R, TT20S, TT20RS and TT20SA woodburning stoves Manufactured by TermaTech A/S, Jegstrupvej 60, DK-8361 Hasselager, Denmark | User and mounting manual reference “99-275 UK version” dated July 2014. The appliance must be fitted with the damper control unit referenced in the manufacturer’s manual. | User and mounting manual reference “99-275 UK version” dated July 2014. The appliance must be fitted with the damper control unit referenced in the manufacturer’s manual. | Wood logs ⁽¹⁾. |
| Termatech TT22 and TT22S convection wood-burning stoves Manufactured by TermaTech A/S, Jegstrupvej 60, DK-8361 Hasselager, Denmark | User and mounting manual reference “99-234 UK version” dated July 2014. The appliance must be fitted with a smoke control kit to ensure the primary and secondary air controls are 25% open in their minimum position. | User and mounting manual reference “99-234 UK version” dated July 2014. The appliance must be fitted with a smoke control kit to ensure the primary and secondary air controls are 25% open in their minimum position. | Wood logs ⁽¹⁾. |
| Therminator II 22 and Therminator II 30 Boiler. Manufactured by Solarfocus Ltd., Werkstrasse 1, 4451 St.Ulrich, Steyr, Austria. | Installation instructions reference “Version: 11/08/06” dated July 2006, operating manual reference “V8.051” dated September 2009 and maintenance instructions reference “Ver.:01/09/06” dated 2006. | Installation instructions reference “Version: 11/08/06” dated July 2006, operating manual reference “V8.051” dated September 2009 and maintenance instructions reference “Ver.:01/09/06” dated 2006. | Wood pellets ⁽¹⁾. |
| Therminator II 27 and Therminator II 36 Boiler. Manufactured by Solarfocus Ltd., Werkstrasse 1, 4451 St.Ulrich, Steyr, Austria. | Installation instructions reference “Version:11/08/06” dated July 2006, operating manual reference “V8.051” dated September 2009 and maintenance instructions reference “Ver.:01/09/06” dated 2006. | Installation instructions reference “Version:11/08/06” dated July 2006, operating manual reference “V8.051” dated September 2009 and maintenance instructions reference “Ver.:01/09/06” dated 2006. | Wood logs ⁽¹⁾. |
| Therminator II 40 Boiler. Manufactured by Solarfocus Ltd., Werkstrasse 1, 4451 St.Ulrich, Steyr, Austria. | Installation instructions reference “Version: 11/08/06” dated July 2006, operating manual reference “V8.051” dated September 2009 and maintenance instructions reference “Ver.:01/09/06” dated 2006. | Installation instructions reference “Version: 11/08/06” dated July 2006, operating manual reference “V8.051” dated September 2009 and maintenance instructions reference “Ver.:01/09/06” dated 2006. | Wood pellets or wood chips ⁽¹⁾. |
| Therminator II 49 and Therminator II 60 Boiler. Manufactured by Solarfocus Ltd., Werkstrasse 1, 4451 St.Ulrich, Steyr, Austria. | Installation instructions reference “Version: 11/08/06” dated July 2006, operating manual reference “V8.051” dated September 2009 and maintenance instructions reference “Ver.:01/09/06” dated 2006. | Installation instructions reference “Version: 11/08/06” dated July 2006, operating manual reference “V8.051” dated September 2009 and maintenance instructions reference “Ver.:01/09/06” dated 2006. | Wood logs or wood pellets or wood chips ⁽¹⁾. |
| Thornhill T3 small. Manufactured by Thornhill Eco Design Ltd., 58-60 Wincheap, Canterbury, Kent, CT1 3RS. | Instruction manual reference “ED/11/05” dated January 2011. The appliance must be fitted with an air plate that prevents the tertiary air controller from closing more than 17mm and opening more than 45mm. | Instruction manual reference “ED/11/05” dated January 2011. The appliance must be fitted with an air plate that prevents the tertiary air controller from closing more than 17mm and opening more than 45mm. | Wood logs ⁽¹⁾. |
| Tiger GH-T Insert Stove. Manufactured by Hughes Design Limited, Denver House, Winster, Derbyshire, DE4 2DH. | Instruction manual reference “Tiger solid fuel heating stoves inset multi-fuel models incorporating GH-T Firebox. Solid Fuel Stoves Manual v12” dated 22nd January 2014 and “Soliftec Smoke Advice Sheet no1” dated 22nd January 2014. The appliance must be fitted with a mechanical stop to prevent closure beyond the 5mm closed position on the secondary air control. | Instruction manual reference “Tiger solid fuel heating stoves inset multi-fuel models incorporating GH-T Firebox. Solid Fuel Stoves Manual v12” dated 22nd January 2014 and “Soliftec Smoke Advice Sheet no1” dated 22nd January 2014. The appliance must be fitted with a mechanical stop to prevent closure beyond the 5mm closed position on the secondary air control. | Wood logs ⁽¹⁾. |
Reading this document does not replace reading the official text published on legislation.gov.uk. Contains public sector information licensed under the Open Government Licence v3.0. We assume no responsibility for any inaccuracies arising from the conversion of the original CLML XML to this format.
This text is published under legislation.gov.uk's own terms of reuse, not a Legalize or public-domain licence.
legislation.gov.uk
Open Government Licence v3.0 (attribution required)
© Crown and database right. Derived from content available under the Open Government Licence v3.0 from legislation.gov.uk.