Class of fireplace Conditions Conditions Conditions
Fireline FXi 5kW, Fireline FPi 5kW, Fireline FX5 and Fireline FP5. Manufactured by Charlton & Jenrick Ltd., Unit D, Stafford Park 2, Telford, Shropshire, TF3 3AR. Instruction manual reference “Issue 03” dated March 2010. The appliance must be fitted with a system that prevents the closure of the secondary air control beyond the 3.5mm open position. Instruction manual reference “Issue 03” dated March 2010. The appliance must be fitted with a system that prevents the closure of the secondary air control beyond the 3.5mm open position. Wood logs ⁽¹⁾.
Fireline Purevision 5kW Freestanding Wood burning Stove. Manufactured by Charlton & Jenrick Ltd, Unit D Stafford Park 2, Telford, Shropshire, TF3 3AR. Installation and operating instructions manual reference “Purevision Freestanding Issue 02” dated January 2014. The appliance must be fitted with a mechanical stop to prevent air supply closure beyond the 18mm open position. Installation and operating instructions manual reference “Purevision Freestanding Issue 02” dated January 2014. The appliance must be fitted with a mechanical stop to prevent air supply closure beyond the 18mm open position. Wood logs ⁽¹⁾.
Fireline Purevision 5kW i5 Inset Wood burning Stove. Manufactured by Charlton & Jenrick Ltd, Unit D Stafford Park 2, Telford, Shropshire, TF3 3AR. Installation and operating instructions manual reference “Purevision Inset Issue 02” dated January 2014. The appliance must be fitted with a mechanical stop to prevent air supply closure beyond the 18mm open position. Installation and operating instructions manual reference “Purevision Inset Issue 02” dated January 2014. The appliance must be fitted with a mechanical stop to prevent air supply closure beyond the 18mm open position. Wood logs ⁽¹⁾.
Fireline Purevision 5kW Wide Freestanding Wood burning Stove. Manufactured by Charlton & Jenrick Ltd, Unit D Stafford Park 2, Telford, Shropshire, TF3 3AR. Installation and operating instructions manual reference “Purevision Freestanding Issue 02” dated January 2014. The appliance must be fitted with a mechanical stop to prevent air supply closure beyond the 15mm open position. Installation and operating instructions manual reference “Purevision Freestanding Issue 02” dated January 2014. The appliance must be fitted with a mechanical stop to prevent air supply closure beyond the 15mm open position. Wood logs ⁽¹⁾.
Fireline Purevision 5kW i5 Wide Inset Wood burning Stove. Manufactured by Charlton & Jenrick Ltd, Unit D Stafford Park 2, Telford, Shropshire, TF3 3AR. Installation and operating instructions manual reference “Purevision Inset Issue 02” dated January 2014. The appliance must be fitted with a mechanical stop to prevent air supply closure beyond the 15mm open position. Installation and operating instructions manual reference “Purevision Inset Issue 02” dated January 2014. The appliance must be fitted with a mechanical stop to prevent air supply closure beyond the 15mm open position. Wood logs ⁽¹⁾.
Fireline Purevision 8.5kW Freestanding Wood burning Stove. Manufactured by Charlton & Jenrick Ltd, Unit D Stafford Park 2, Telford, Shropshire, TF3 3AR. Installation and operating instructions manual reference “Purevision Freestanding Issue 02” dated January 2014. The appliance must be fitted with a mechanical stop to prevent air supply closure beyond the 22mm open position. Installation and operating instructions manual reference “Purevision Freestanding Issue 02” dated January 2014. The appliance must be fitted with a mechanical stop to prevent air supply closure beyond the 22mm open position. Wood logs ⁽¹⁾.
Fireline Purevision 8.5kW i8.5 Inset Wood burning Stove. Manufactured by Charlton & Jenrick Ltd, Unit D Stafford Park 2, Telford, Shropshire, TF3 3AR. Installation and operating instructions manual reference “Purevision Inset Issue 02” dated January 2014. The appliance must be fitted with a mechanical stop to prevent air supply closure beyond the 22mm open position. Installation and operating instructions manual reference “Purevision Inset Issue 02” dated January 2014. The appliance must be fitted with a mechanical stop to prevent air supply closure beyond the 22mm open position. Wood logs ⁽¹⁾.
Firematic 25, 50, 90 and 150. Manufactured by HERZ Armaturen Ges.m.b.H, Richard-Strauss-Straße 22,A-1230 Wien, Austria. Manufacturer’s instructions reference “Bedienungsanleitung Firematic V 1.1 ENG doc” dated June 2005. Manufacturer’s instructions reference “Bedienungsanleitung Firematic V 1.1 ENG doc” dated June 2005. Chipped wood, wood pellets, or planed wood shavings ⁽¹⁾.
Firematic 45 and 60. Manufactured by HERZ Armaturen Ges.m.b.H., Richard-Strauss-Straße 22,A-1230 Wien, Austria. Instruction manual reference “05.007 Operating Instructions – FM (1Ph) 20 35 45 60 v2.3” dated August 2009. Instruction manual reference “05.007 Operating Instructions – FM (1Ph) 20 35 45 60 v2.3” dated August 2009. Wood pellets conforming to ÖNORM M7135 with diameter of 6mm or wood chips up to a maximum size of 50mm and maximum water content 35% ⁽¹⁾.
Firematic FM 130, FM 151, FM 180 and FM 199. Manufactured by Herz Energietechnik GmbH, Herzstraße 1, 7423 Pinkafeld, Austria. Instruction manual reference “Operating Instructions Herz firematic 130 – 199 BioControl” version Betriebsanleitung firematic 20-201 BioControl Englisch V 3.1. Instruction manual reference “Operating Instructions Herz firematic 130 – 199 BioControl” version Betriebsanleitung firematic 20-201 BioControl Englisch V 3.1. Wood chips and wood pellets ⁽¹⁾.
Firenzo Aucklander stove. Manufactured by Firenzo Woodfires UK Ltd., 98 Niven Street, Napier 4142, New Zealand. Instruction manual reference “AL” dated 15th January 2013 and instruction manual reference “AU” dated 1st February 2013. The appliance must be fitted with a mechanical stop to prevent air control slots closure beyond the 6.5mm open position. Instruction manual reference “AL” dated 15th January 2013 and instruction manual reference “AU” dated 1st February 2013. The appliance must be fitted with a mechanical stop to prevent air control slots closure beyond the 6.5mm open position. Wood logs ⁽¹⁾.
Firenzo Bronte stove. Manufactured by Firenzo Woodfires UK Ltd., 98 Niven Street, Napier 4142, New Zealand. Instruction manual reference “BI” dated 15th January 2013 and instruction manual reference “BU” dated 1st February 2013. The appliance must be fitted with a mechanical stop to prevent air control slots closure beyond the 6.5mm open position. Instruction manual reference “BI” dated 15th January 2013 and instruction manual reference “BU” dated 1st February 2013. The appliance must be fitted with a mechanical stop to prevent air control slots closure beyond the 6.5mm open position. Wood logs ⁽¹⁾.
Firenzo Contessa stove. Manufactured by Firenzo Woodfires UK Ltd., 98 Niven Street, Napier 4142, New Zealand. Instruction manual reference “CI” dated 15th January 2013 and instruction manual reference “CU” dated 1st February 2013. The appliance must be fitted with a mechanical stop to prevent air control slots closure beyond the 6mm open position. Instruction manual reference “CI” dated 15th January 2013 and instruction manual reference “CU” dated 1st February 2013. The appliance must be fitted with a mechanical stop to prevent air control slots closure beyond the 6mm open position. Wood logs ⁽¹⁾.
Firenzo Fires Hastings 4.8kW wood burning stove. Manufactured by Firenzo Fires, 98 Niven Street, Napier4142, New Zealand. User manual reference “HU 2014-10-16” dated 16th October 2014 and installation manual reference “HI 2014-10-16” dated 16th October 2014. The appliance must be fitted with a mechanical stop to prevent air control closure beyond the 6mm open position. User manual reference “HU 2014-10-16” dated 16th October 2014 and installation manual reference “HI 2014-10-16” dated 16th October 2014. The appliance must be fitted with a mechanical stop to prevent air control closure beyond the 6mm open position. Wood logs ⁽¹⁾.
Firenzo Lady Kitchener stove. Manufactured by Firenzo Woodfires UK Ltd., 98 Niven Street, Napier 4142, New Zealand. Instruction manual reference “LKI” dated 15th January 2013 and instruction manual reference “LKU” dated 1st February 2013. The appliance must be fitted with a mechanical stop to prevent air control slots closure beyond the 6.5mm open position. Instruction manual reference “LKI” dated 15th January 2013 and instruction manual reference “LKU” dated 1st February 2013. The appliance must be fitted with a mechanical stop to prevent air control slots closure beyond the 6.5mm open position. Wood logs ⁽¹⁾.
Firenzo Napier 4.8kW free standing wood burning stove. Manufactured by Hewitsons ltd, 98 Niven street, Onekawa, Napier, New Zealand. Installation manual reference “UKNapierInstall/4.8/v1 dated 24th January 2014 and instruction manual reference “UKNapierUser/4.8/v1 dated 24th January 2014. The appliance must be fitted with a permanent stop to prevent closure of the air slide beyond 7mm. Installation manual reference “UKNapierInstall/4.8/v1 dated 24th January 2014 and instruction manual reference “UKNapierUser/4.8/v1 dated 24th January 2014. The appliance must be fitted with a permanent stop to prevent closure of the air slide beyond 7mm. Dry wood logs ⁽¹⁾.
Firenzo Wellingtonian stove. Manufactured by Firenzo Woodfires UK Ltd., 98 Niven Street, Napier 4142, New Zealand. Instruction manual reference “WI” dated 15th January 2013 and instruction manual reference “WU” dated 1st February 2013. The appliance must be fitted with a mechanical stop to prevent air control slots closure beyond the 6.5mm open position. Instruction manual reference “WI” dated 15th January 2013 and instruction manual reference “WU” dated 1st February 2013. The appliance must be fitted with a mechanical stop to prevent air control slots closure beyond the 6.5mm open position. Wood logs ⁽¹⁾.
Firestorm 4.5 SE. Manufactured by The Heat Resistant Glass Company Ltd., Unit 2, Bracewell Avenue, Poulton Industrial Estate, Poulton Le Fylde, FY6 8JF. Instruction manual reference “4.5KW SE Issue (6928) 1” dated 28th April 2012. The appliance must be fitted with a stop that will only allow a minimum 3mm air gap between the air control plate and the appliance when the secondary air is turned down to its minimum position. Instruction manual reference “4.5KW SE Issue (6928) 1” dated 28th April 2012. The appliance must be fitted with a stop that will only allow a minimum 3mm air gap between the air control plate and the appliance when the secondary air is turned down to its minimum position. Wood logs ⁽¹⁾.
Firestorm 6.5 SE. Manufactured by The Heat Resistant Glass Company Ltd., Unit 2, Bracewell Avenue, Poulton Industrial Estate, Poulton Le Fylde, FY6 8JF. Instruction manual reference “6.5KW SE Issue (6928) 3” dated 28th April 2012. The appliance must be fitted with a stop that will only allow a minimum air gap 6mm between the air control plate and the appliance when the secondary air is turned down to its minimum position. Instruction manual reference “6.5KW SE Issue (6928) 3” dated 28th April 2012. The appliance must be fitted with a stop that will only allow a minimum air gap 6mm between the air control plate and the appliance when the secondary air is turned down to its minimum position. Wood logs ⁽¹⁾.
Firestorm 10 SE. Manufactured by The Heat Resistant Glass Company Ltd., Unit 2, Bracewell Avenue, Poulton Industrial Estate, Poulton Le Fylde, FY6 8JF. Instruction manual reference “10KW SE Issue (6928) 2” dated 28th April 2012. The appliance must be fitted with a stop that will only allow a minimum air gap 6mm between the air control plate and the appliance when the secondary air is turned down to its minimum position. Instruction manual reference “10KW SE Issue (6928) 2” dated 28th April 2012. The appliance must be fitted with a stop that will only allow a minimum air gap 6mm between the air control plate and the appliance when the secondary air is turned down to its minimum position. Wood logs ⁽¹⁾.
Firewarm 4SE stove. Manufactured by Heat Design, 30 Hawthorn Road, Western Industrial Estate, Naas Road, Dublin 12, Ireland. Instruction manual reference “FW468SE” dated 25th July 2012. The appliance must be fitted with a system to prevent closure of the secondary air control beyond 5mm open. Instruction manual reference “FW468SE” dated 25th July 2012. The appliance must be fitted with a system to prevent closure of the secondary air control beyond 5mm open. Wood logs ⁽¹⁾.
Firewarm 06C inset stove. Manufactured by Heat Design, 30 Hawthorn Road, Western Industrial Estate, Naas Road, Dublin 12, Ireland. Instruction manual reference “FW06C” dated 26th July 2012. The appliance must be fitted with a permanent stop to prevent closure of the secondary air control beyond 20% open. Instruction manual reference “FW06C” dated 26th July 2012. The appliance must be fitted with a permanent stop to prevent closure of the secondary air control beyond 20% open. Wood logs ⁽¹⁾.
Firewarm 6SE stove. Manufactured by Heat Design, 30 Hawthorn Road, Western Industrial Estate, Naas Road, Dublin 12, Ireland. Instruction manual reference “FW468SE” dated 25th July 2012. The appliance must be fitted with a system to prevent closure of the secondary air control beyond 75% from closed. Instruction manual reference “FW468SE” dated 25th July 2012. The appliance must be fitted with a system to prevent closure of the secondary air control beyond 75% from closed. Wood logs ⁽¹⁾.
Firewarm 8SE stove. Manufactured by Heat Design, 30 Hawthorn Road, Western Industrial Estate, Naas Road, Dublin 12, Ireland. Instruction manual reference “FW468SE” dated 25th July 2012. The appliance must be fitted with a system to prevent closure of the secondary air control beyond 25% from closed. Instruction manual reference “FW468SE” dated 25th July 2012. The appliance must be fitted with a system to prevent closure of the secondary air control beyond 25% from closed. Wood logs ⁽¹⁾.
Firewarm 11C Inset stove. Manufactured by Heat Design, 30 Hawthorn Road, Western Industrial Estate, Naas Road, Dublin 12, Ireland. Instruction manual reference “FW11C” dated 26th July 2012. The appliance must be fitted with a permanent stop to prevent closure of the secondary air control beyond 20% open. Instruction manual reference “FW11C” dated 26th July 2012. The appliance must be fitted with a permanent stop to prevent closure of the secondary air control beyond 20% open. Wood logs ⁽¹⁾.
Firewarm FW5i Multi-fuel inset stove. Manufactured by Heat Design Ltd., 30 Hawthorn Road, Western Industrial Estate, Naas Road, Dublin 12, Ireland. Installation and operating instructions reference “FW5i” dated 2nd May 2013. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond 3.5mm open. Installation and operating instructions reference “FW5i” dated 2nd May 2013. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond 3.5mm open. Wood logs ⁽¹⁾.
Flatford 5K, Barrington 5K and Hampstead 5K wood burning stoves. Manufactured by Chesneys Ltd., 194-200 Battersea Park Road, London, SW11 4ND. Instruction manual reference “CH5K – V1” dated 14th March 2012. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 18mm open position. Instruction manual reference “CH5K – V1” dated 14th March 2012. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 18mm open position. Wood logs ⁽¹⁾.
Flavel Arundel FCMSB 4.9kW Multifuel Stove. Manufactured by BFM Europe Limited, Trentham Lakes North, Stoke-on-Trent, Staffordshire, ST4 4TJ Manufacturers Installation and Operating Instructions dated 19th November 2014 reference “B-176820” Fitted with the smoke control stop (part number F-176950) to prevent secondary air control closure beyond the 30% open position when sold into smoke control areas Manufacturers Installation and Operating Instructions dated 19th November 2014 reference “B-176820” Fitted with the smoke control stop (part number F-176950) to prevent secondary air control closure beyond the 30% open position when sold into smoke control areas Wood logs ⁽¹⁾.
Flavel Rochester FCSSB 7kW Multifuel Stove. Manufactured by BFM Europe Limited, Trentham Lakes North, Stoke-on-Trent, Staffordshire, ST4 4TJ Installation and Operating Instructions dated 29/02/2016 reference “B-181940 Issue 5”. Installation and Operating Instructions dated 29/02/2016 reference “B-181940 Issue 5”. Wood logs⁽¹⁾.
Fogo Montanha Versatile S600SE, Versatile S600 SE Table, Versatile S600 SE Spider, Versatile S600 SE Square, Versatile S600 SE Cube, Versatile S600 SE 2X Cube and Versatile S600 SE Round wood-burning stoves manufactured by Fogo Montanha (Solzaima, S.A.) Rua dos Outarelos, 111 3750-362 Belazamia do Chao, Portugal. Instruction manual reference “S600 –UK V1” dated 2014. The appliance must be fitted with a permanent stop or other measure to prevent closure of the air control beyond the 40% open position. Instruction manual reference “S600 –UK V1” dated 2014. The appliance must be fitted with a permanent stop or other measure to prevent closure of the air control beyond the 40% open position. Wood pellets ⁽¹⁾.
Franco Belge Model 134 08 11 Savoy EA (8kW output) wood burning stove. Manufactured by Franco Belge, Staub Fonderie SA, Rue Orphée Variscotte, 59660, Merville, France. Instructions manual reference “1290-1” dated 9th July 2009. Instructions manual reference “1290-1” dated 9th July 2009. Wood logs ⁽¹⁾.
Franco Belge Model 134 08 09 Savoy Mk II Elegance multifuel stove with KEA 13408 smoke control kit. Manufactured by Franco Belge, Staub Fonderie SA, Rue Orphée Variscotte, 59660, Merville, France. Instructions manual reference “1290-1” dated 9th July 2009. Instructions manual reference “1290-1” dated 9th July 2009. Wood logs ⁽¹⁾.
Franco Belge Montfort MK2 wood burning stove. Manufactured by Franco Belge, Staub Fonderie SA, Rue Orphée Variscotte, 59660, Merville, France. Instruction manual reference “1295-3” dated 17th November 2009. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 25% open position. Instruction manual reference “1295-3” dated 17th November 2009. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 25% open position. Wood logs ⁽¹⁾.
Fröling Lambdamat commercial wood chip boiler models 500, 750 and 1000. Manufactured by Fröling Heizkessel-und Behälterbau Ges.m.b.H., Industriestraße 12, A-4710 Grieskirchen, Austria. Operating and installation manual reference “B 069 01 04” dated February 2004. Operating and installation manual reference “B 069 01 04” dated February 2004. Wood chips ⁽¹⁾.
Froling P1 7, 10, 15 and 20 pellet boilers. Manufactured by Froling Heizkessel und Behalterbau GmbH, A-4710 Grieskirchen, Industriestrasse 12, Austria. Operating instructions manual reference “B1000013_en Edition 15/07/2014” dated 15th July 2014. Operating instructions manual reference “B1000013_en Edition 15/07/2014” dated 15th July 2014. Wood pellets ⁽¹⁾.
Froling P4 45 pellet boiler. Manufactured by Froling Heizkessel und Behalterbau GmbH, A-4710 Grieskirchen, Industriestrasse 12, Austria. Operating instructions manual reference “BO870114_en Edition 18/07/2014” dated 18th July 2014. Operating instructions manual reference “BO870114_en Edition 18/07/2014” dated 18th July 2014. Wood pellets ⁽¹⁾.
Fröling P4 8, 15, 20, 25, 32, 38, 48 and 60 pellet boilers. Manufactured by Fröling Heizkessel-und Behälterbau Ges.m.b.H., Industriestraße 12, A-4710 Grieskirchen, Austria. Instruction manual reference “BO430408 _en” dated July 2009. Instruction manual reference “BO430408 _en” dated July 2009. Wood pellets with a diameter of 6mm ⁽¹⁾.
Fröling P4 80 and P4 100 wood pellet boilers. Manufactured by Fröling Heizkessel-und Behälterbau Ges.m.b.H., Industriestraße 12, A-4710 Grieskirchen, Austria. Instruction manual reference “B043 – Version 8” dated May 2012. Instruction manual reference “B043 – Version 8” dated May 2012. Wood pellets ⁽¹⁾.
Froling S4 Turbo 15 15kW; Froling S4 Turbo 22 22kW; Froling S4 Turbo 28 28kW; Froling S4 Turbo 34 34kW; Froling S4 Turbo 40 40kW; Froling S4 Turbo 50 50kW; and Froling S4 Turbo 60 60kW. Manufactured by Fröling Heizkessel-und Behälterbau Ges.m.b.H., Industriestraße 12, A-4710 Grieskirchen, Austria. Assembly instruction manual reference “M0970208” dated November 2008 and operating instruction manual reference “B0510108” dated November 2008. Assembly instruction manual reference “M0970208” dated November 2008 and operating instruction manual reference “B0510108” dated November 2008. Wood logs ⁽¹⁾.
Froling T4 130 and 150 wood chip and pellet boilers. Manufactured by Froling Heizkessel und Behalterbau GmbH, A-4710 Grieskirchen, Industriestrasse 12, Austria. Operating instructions manual reference “BO830113_en Edition 06/11/2013” dated 6th November 2013. Operating instructions manual reference “BO830113_en Edition 06/11/2013” dated 6th November 2013. Wood pellets or wood chips ⁽¹⁾.
Fröling T4 24, 30, 40, 50, 60, 75, 90, 100 and 110kW boilers. Manufactured by Fröling Heizkessel-und Behälterbau Ges.m.b.H., Industriestraße 12, A-4710 Grieskirchen, Austria. Instruction manual reference “B071 - Version 05” dated May 2012. Instruction manual reference “B071 - Version 05” dated May 2012. Wood pellets or wood chips ⁽¹⁾.
Fröling Turbomatic 28, 35, 48 and 55. Manufactured by Fröling Heizkessel-und Behälterbau Ges.m.b.H., Industriestraße 12, A-4710 Grieskirchen, Austria. Installation instructions reference “M 060 01 03” dated November 2003 and operating instructions reference “99229a” dated August 2002. Installation instructions reference “M 060 01 03” dated November 2003 and operating instructions reference “99229a” dated August 2002. Wood chips with less than 35% moisture content that meet ÖNORM (a) M 7133: 1998 size class G30 or wood pellets of 6mm diameter and a moisture content below 10% ⁽¹⁾.
Fröling Turbomatic 85, 100 and 110. Manufactured by Fröling Heizkessel-und Behälterbau Ges.m.b.H., Industriestraße 12, A-4710 Grieskirchen, Austria. Installation instructions reference “M 060 01 03” dated November 2003 and operating instructions reference “99229a” dated August 2002. Installation instructions reference “M 060 01 03” dated November 2003 and operating instructions reference “99229a” dated August 2002. Wood chips with less than 35% moisture content that meet ÖNORM (a) M 7133; 1998 size class G30 or G50, wood pellets of 6mm diameter and a moisture content below 10% ⁽¹⁾.
Fröling Turbomat 150 and 220. Manufactured by Fröling Heizkessel-und Behälterbau Ges.m.b.H., Industriestraße 12, A-4710 Grieskirchen, Austria. Manufacturer’s instructions reference “BO310003” dated August 2003. Manufacturer’s instructions reference “BO310003” dated August 2003. Wood pellets, or wood chips ⁽¹⁾.
Fröling Turbomat 320 and 500. Manufactured by Fröling Heizkessel-und Behälterbau Ges.m.b.H., Industriestraße 12, A-4710 Grieskirchen, Austria. Manufacturer’s instructions reference “B0340004” dated November 2004. Manufacturer’s instructions reference “B0340004” dated November 2004. Wood pellets, or wood chips ⁽¹⁾.
Fröling TX150 150kW boiler with Exhaust Gas Recirculation device. Manufactured by Fröling Heizkessel-und Behälterbau Ges.m.b.H., Industriestraße 12, A-4710 Grieskirchen, Austria. Installation instruction manual reference “M1130009” dated September 2010 and operating instruction manual reference “B 067 00 09” dated September 2010. Installation instruction manual reference “M1130009” dated September 2010 and operating instruction manual reference “B 067 00 09” dated September 2010. Wood chips with a moisture content ≤30% and a maximum cross sectional area of 5cm2 or wood pellets with a moisture content of ≤10% and a maximum diameter of 10mm ⁽¹⁾.
Fröling TX 200 199kW and TX 250 250kW boilers with Exhaust Gas Recirculation device. Manufactured by Fröling Heizkessel-und Behälterbau Ges.m.b.H., Industriestraße 12, A-4710 Grieskirchen, Austria. Instruction manual reference “B067 – Version 03” dated May 2012. Instruction manual reference “B067 – Version 03” dated May 2012. Wood pellets or wood chips ⁽¹⁾.
Fröling: SP Dual 15kW boiler; SP Dual 22kW boiler; SP Dual 28kW boiler; SP Dual 34kW boiler; and SP Dual 40kW boiler. Manufactured by Fröling Heizkessel-und Behälterbau Ges.m.b.H., Industriestraße 12, A-4710 Grieskirchen, Austria. Operating instructions reference “B0760212_en Edition 09/10/2012” dated 9th October 2012. Operating instructions reference “B0760212_en Edition 09/10/2012” dated 9th October 2012. Wood logs or wood pellets ⁽¹⁾.
Future Fires Panoramic FX1. Manufactured by Gen-Fab Ltd., Swinton Bridge Industrial Estate, Whitelee Rd, Swinton, S64 8BH. Instruction manual reference “PANFXREV2” dated 31st October 2012. Instruction manual reference “PANFXREV2” dated 31st October 2012. Wood logs ⁽¹⁾.
Gilles HPK-RA 13kW, 15kW, 20kW, 25kW, 30kW, 35kW, 40kW, 45kW, 49kW, 60kW, 70kW, 75kW, 85kW, 95kW, 100kW, 120kW, and 145kW. Manufactured by Gilles Energie – und Umwelttechnik Gmbh, Koaserbauer Str. 16A-4810 Gmunden, Austria. Manufacturer’s instructions reference “Gilles/0-145/1” dated January 2007. Manufacturer’s instructions reference “Gilles/0-145/1” dated January 2007. Wood pellets, or wood chips ⁽¹⁾.
Gilles HPK-RA 160. Manufactured by Gilles Energie – und Umwelttechnik Gmbh, Koaserbauer Str. 16A-4810 Gmunden, Austria. Instruction and operating manuals reference “BD-200-01a-01” dated November 2008, “BD-200-01a-02” dated November 2008, “BD-200-01a-03” dated November 2008, “BD-200-01a-04” dated November 2008, “BD-200-01a-06” dated November 2008, “BD-200-03a-07” dated November 2008, and “BD-200-03a-09” dated November 2008. Instruction and operating manuals reference “BD-200-01a-01” dated November 2008, “BD-200-01a-02” dated November 2008, “BD-200-01a-03” dated November 2008, “BD-200-01a-04” dated November 2008, “BD-200-01a-06” dated November 2008, “BD-200-03a-07” dated November 2008, and “BD-200-03a-09” dated November 2008. Wood chips and wood pellets ⁽¹⁾.
Gilles HPK USK 150kW, 180kW, 240kW and 300kW. Manufactured by Gilles Energie – und Umwelttechnik Gmbh, Koaserbauer Str. 16A-4810 Gmunden, Austria. Manufacturer’s instructions reference “Gilles/150-300/1” dated January 2007. Manufacturer’s instructions reference “Gilles/150-300/1” dated January 2007. Wood pellets, or wood chips ⁽¹⁾.
Gilles HPK USK 360kW. Manufactured by Gilles Energie – und Umwelttechnik Gmbh, Koaserbauer Str. 16A-4810 Gmunden, Austria. Manufacturer’s operating instructions reference “Gilles 360/1” dated January 2008. Manufacturer’s operating instructions reference “Gilles 360/1” dated January 2008. Wood pellets or wood chips ⁽¹⁾.
Gilles HPKI-K 180, 195, 240, 300, 360, 450, 550, 700, 900, 995, 1200 and 1600. Manufactured by Gilles Energie – und Umwelttechnik Gmbh, Koaserbauer Str. 16A-4810 Gmunden, Austria. Instruction manual reference “Operating Instruction HPKI-K Underfeed Stoking. 1-general-hpki-k underfeed stoking” dated November 2008. Instruction manual reference “Operating Instruction HPKI-K Underfeed Stoking. 1-general-hpki-k underfeed stoking” dated November 2008. Wood chips and pellets ⁽¹⁾.
Gilles HPKI-R 999 kW biomass boiler manufactured by Gilles Energie und Umwelttechnik GmbH & Co KG Limited, Koaserbauerstraβe, A-4180 Gmuden, Austria. Installation, operation and maintenance manual reference “BD-HPKI-R-999-01.1 Version 02/2014” dated 23rd July 2014. The appliance must be fitted with cyclone dust arrestment. Installation, operation and maintenance manual reference “BD-HPKI-R-999-01.1 Version 02/2014” dated 23rd July 2014. The appliance must be fitted with cyclone dust arrestment. Wood chips ⁽¹⁾.
Gilles UTSK 450kW, 550kW, 700kW, 900kW, 1200kW, and 1600kW Boilers. Manufactured by Gilles Energie – und Umwelttechnik Gmbh, Koaserbauer Str. 16A-4810 Gmunden, Austria. Manufacturer’s operating instructions reference “Gilles 360/1” dated January 2008. Manufacturer’s operating instructions reference “Gilles 360/1” dated January 2008. Wood pellets or wood chips ⁽¹⁾.
Gozney G1200/W, G1400/W, G1600/W and G1800/W wood-burning pizza ovens. Manufactured by Gozney Ltd., Units 18 & 19, Radar Way, Christchurch Business Park, The Runway, Christchurch, BH23 4JE. Operational manual reference “Version 1.1” dated July 2013. Operational manual reference “Version 1.1” dated July 2013. Wood logs ⁽¹⁾.
Grant Spira Condensing Wood Pellet Boiler 6-26kW model number WPS626 and 9-36kW model number WPS936. Manufactured by Grant UK Ltd., Hopton House, Hopton Industrial Estate, Devizes, Wiltshire, SN10 2EU. Instruction manual reference “IRL NO.012 Rev; 1” dated April 2012. Instruction manual reference “IRL NO.012 Rev; 1” dated April 2012. 6mm wood pellets ⁽¹⁾.
Grant Vectra 4-16 16kW condensing wood pellet boiler. Manufactured by Grant(UK) Limited, Hopton House, Hopton Industrial Estate, Devizes, Wiltshire, SN10 2EU Installation & Servicing Instructions manual dated July 2015 reference “Part No. DOC.47 Rev.06 13/07/15” Installation & Servicing Instructions manual dated July 2015 reference “Part No. DOC.47 Rev.06 13/07/15” Wood Pellets ⁽¹⁾.
Graphite 5 model number GR905 4.9 kW multifuel stove. Manufactured by Hi-Flame Fireplace UK Limited, Unit 5A, Holmes Chapel Business Park, Manor Lane, Holmes Chapel, Cheshire CW4 8AF. Instruction manual reference “GR905/UK/NI/ROI/V3 18-07-14” dated July 2014. The appliance must be fitted with a mechanical stop to prevent closure of the main air control beyond the 50% open position. Instruction manual reference “GR905/UK/NI/ROI/V3 18-07-14” dated July 2014. The appliance must be fitted with a mechanical stop to prevent closure of the main air control beyond the 50% open position. Wood logs ⁽¹⁾.
Graphite 8 model number GR908 8kW multifuel stove. Manufactured by Hi-Flame Fireplace UK Limited, Unit 5A, Holmes Chapel Business Park, Manor Lane, Holmes Chapel, Cheshire CW4 8AF. Instruction manual reference “GR908/UK/NI/ROI/V4-D 18-07-14” dated July 2014. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 20% open position, and a 70mm opening of the door rope seal. Instruction manual reference “GR908/UK/NI/ROI/V4-D 18-07-14” dated July 2014. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 20% open position, and a 70mm opening of the door rope seal. Wood logs ⁽¹⁾.
Greencast 5MF Traditional, Greencast 5MF Modern, Greencast 8MF Traditional and Greencast 8MF Modern multifuel stoves. Manufactured by Capital Fireplaces Ltd., 12-17 Henlow Trading Estate, Henlow Camp, Hitchin, SG16 6DS. Installation and operating instructions manual reference “Greencast MF&WD Version 1” dated June 2013. The appliance must be fitted with the manufacturer’s smoke control kit. Installation and operating instructions manual reference “Greencast MF&WD Version 1” dated June 2013. The appliance must be fitted with the manufacturer’s smoke control kit. Wood logs ⁽¹⁾.
Greencast 5WD Traditional and Greencast 5WD Modern woodburning stoves. Manufactured by Capital Fireplaces Ltd., 12-17 Henlow Trading Estate, Henlow Camp, Hitchin, SG16 6DS. Installation and operating instructions manual reference “Greencast MF&WD Version 1” dated June 2013. Installation and operating instructions manual reference “Greencast MF&WD Version 1” dated June 2013. Wood logs ⁽¹⁾.
Greencast 8WD Traditional and Greencast 8WD Modern wood-burning stoves. Manufactured by Capital Fireplaces Ltd., 12-17 Henlow Trading Estate, Henlow Camp, Hitchin, SG16 6DS. Installation and operating instructions manual reference “Greencast MF&WD Version 1” dated June 2013. The appliance must be fitted with the manufacturer’s smoke control kit. Installation and operating instructions manual reference “Greencast MF&WD Version 1” dated June 2013. The appliance must be fitted with the manufacturer’s smoke control kit. Wood logs ⁽¹⁾.
Green Energy Engineering PROPEL P70 and P100 Pellet Boilers. Manufactured by Kozlusan – Salih Kozlu, Kayalioilu Kasabasi, Akhisar, Manisa, PK 23, Turkey. Instruction manual reference “PROPEL Wood Pellet Boiler Models: P70 – P100 Version 2” dated 23rd September 2012. Instruction manual reference “PROPEL Wood Pellet Boiler Models: P70 – P100 Version 2” dated 23rd September 2012. Wood pellets ⁽¹⁾.
Green Energy Engineering PROPEL P25 and P40 wood pellet boilers. Manufactured by Kozlusan – Salih Kozlu, Kayalioilu Kasabasi, Akhisar, Manisa, PK 23, Turkey. Instruction manual reference “Owner’s Manual PROPEL Wood Pellet Boiler Version 2” dated 23rd September 2012. Instruction manual reference “Owner’s Manual PROPEL Wood Pellet Boiler Version 2” dated 23rd September 2012. Wood pellets ⁽¹⁾.
Green Energy Engineering SLIMPEL S25. Manufactured by Kozlusan – Salih Kozlu, Kayalioilu Kasabasi, Akhisar, Manisa, PK 23, Turkey. Instruction manual reference “Owner’s Manual SLIMPEL Wood Pellet Boiler Version 2” dated 23rd September 2013. Instruction manual reference “Owner’s Manual SLIMPEL Wood Pellet Boiler Version 2” dated 23rd September 2013. Wood pellets ⁽¹⁾.
Greenflame 28 Pellet Boiler. Manufactured by Trianco Ltd., Thorncliffe, Chapletown, Sheffield, S35 2PH. Instruction manual reference “Installation & Operation Manual V.2.1” dated July 2012. Instruction manual reference “Installation & Operation Manual V.2.1” dated July 2012. 6mm wood pellets ⁽¹⁾.
Greenflame Eco 10kW Model Number FG3730, FG3731, FG3790, FG3791 Greenflame Eco 15kW Model Number FG3732, FG3733, FG3792, FG3793 Greenflame Eco 25kW Model Number FG3734, FG3735, FG3794, FG3795 Greenflame Eco 40kW Model Number FG3736, FG3737, FG3796, FG3797 Greenflame Eco 60kW Model Number FG3738, FG3739, FG3743, FG3798, FG3799 manufactured by T.R. Engineering Ltd, Unit 7 Newton Chambers Way, Thornecliffe, Chapeltown, Sheffield, S35 2PH Greenflame Eco Wood Pellet Boiler 10-60 kW Installation, Operation and servicing Instructions manual dated April 2015 reference “400012” Greenflame Eco Wood Pellet Boiler 10-60 kW Installation, Operation and servicing Instructions manual dated April 2015 reference “400012” Wood pellets ⁽¹⁾.
Guntamatic Biocom and Powercorn 50 and 75. Manufactured by GUNTAMATIC Heiztechnik GmbH A-4722 PEUERBACH Bruck 7, Austria. Instruction manual reference “GUN/BIO/OP/ VI/0709” dated 29th July 2009. Instruction manual reference “GUN/BIO/OP/ VI/0709” dated 29th July 2009. Wood pellets with a diameter of 6mm and a length of between 10 and 30 mm ⁽¹⁾.
Guntamatic Biocom and Powercorn 100. Manufactured by GUNTAMATIC Heiztechnik GmbH A-4722 PEUERBACH Bruck 7, Austria. Instruction manual reference “GUN/BIO/OP/VI/0709” dated 29th July 2009. Instruction manual reference “GUN/BIO/OP/VI/0709” dated 29th July 2009. Wood pellets with a diameter of 6mm and a length of between 10 and 30 mm, or wood chip with less than 35% moisture content and meeting ÖNORM M 7133:1998 size class G30 ⁽¹⁾.
Guntamatic Powerchip 50 and 75. Manufactured by Guntamatic Heiztechnik GmbH A-4722 PEUERBACH Bruck 7, Austria. Instruction manual reference “GUN/POW/OP/VI/0709” dated 29th July 2009. Instruction manual reference “GUN/POW/OP/VI/0709” dated 29th July 2009. Wood pellets with a diameter of 6mm and a length of between 10 and 30 mm ⁽¹⁾.
Guntamatic Powerchip 100. Manufactured by GUNTAMATIC Heiztechnik GmbH A-4722 PEUERBACH Bruck 7, Austria. Instruction manual reference “GUN/POW/OP/VI/0709” dated 29th July 2009. Instruction manual reference “GUN/POW/OP/VI/0709” dated 29th July 2009. Wood pellets with a diameter of 6mm and a length of between 10 and 30 mm, or wood chip less with than 35% moisture content and meeting ÖNORM M 7133:1998 size class G30 ⁽¹⁾.
Guntamatic PRO 175, PRO 199, PRO 250. Manufactured by GUNTAMATIC Heiztechnik GmbH A – 4722 PEUERBACH, Bruck 7, Austria. Operating instructions and system log book reference “PRO-13-00-00-00-01-BADE” dated October 2013. Operating instructions and system log book reference “PRO-13-00-00-00-01-BADE” dated October 2013. Wood chips or wood pellets ⁽¹⁾.
Guntamatic PRO-Flex 175, PRO-Flex 199, PRO-Flex 250. Manufactured by GUNTAMATIC Heiztechnik GmbH A – 4722 PEUERBACH, Bruck 7, Austria. Operating instructions and system log book reference “PRO-Flex-A-00-00-00-01-BADE” dated October 2013. Operating instructions and system log book reference “PRO-Flex-A-00-00-00-01-BADE” dated October 2013. Wood pellets ⁽¹⁾.
Hamont CATfire 350 USZI pellet boiler fitted with CATfire 300 cyclone. Manufactured by Hamont Contracting and Trading, spol. s.r.o., Sedlište 227, postal code 739 36, district Frýdek-Mistek, Czech Republic. Operating instruction reference “Operating Manual for Boilers CATfire 150-500kW” dated 1st January 2008. Operating instruction reference “Operating Manual for Boilers CATfire 150-500kW” dated 1st January 2008. Wood pellets with a diameter of 6mm and a maximum length of 30 mm ⁽¹⁾.
Hampstead 8, Hampstead LS 8, Hampstead XLS 8, Belgravia 8, Barrington 8, Petworth 8 and Flatford 8 stoves. Manufactured by Chesneys Ltd., 194-200 Battersea Park Road, London, SW11 4ND. Instruction manual reference “CH8K - V12” dated 31st October 2011. The appliance must be fitted with a system that prevents closure of the air controls further than 40mm from open and with a permanent stop that prevents closure of the secondary air slider beyond 30% open. Instruction manual reference “CH8K - V12” dated 31st October 2011. The appliance must be fitted with a system that prevents closure of the air controls further than 40mm from open and with a permanent stop that prevents closure of the secondary air slider beyond 30% open. Wood logs ⁽¹⁾.
Handöl 31, Handöl 31A, Handöl 32, Handöl 32A, Handöl 33T, Handöl 34T, Handöl 35T,Varde Ovne Look 1, Varde Ovne Look 2, Varde Ovne Look 3. Manufactured by Nibe AB, Box 134, SE-285 23 Markaryd, Sweden. Installation instructions reference “IAV SE/EX 0811-4 511941” and lighting instructions reference “BAV SE/EX H30 511942”. The appliance must be fitted with a permanent stop on the air inlet to prevent closure beyond the 45% open position. Installation instructions reference “IAV SE/EX 0811-4 511941” and lighting instructions reference “BAV SE/EX H30 511942”. The appliance must be fitted with a permanent stop on the air inlet to prevent closure beyond the 45% open position. Untreated dry wood with less than 20% moisture ⁽¹⁾.
Handöl 50, Handöl 51, Handöl 52, Handöl 52T, Handöl 53, Handöl 54, Handöl 54T, Handöl 51L,Varde Ovne S1, Varde Ovne S2, Varde Ovne S3. Manufactured by Nibe AB, Box 134, SE-285 23 Markaryd, Sweden. Installation instructions reference “IAV SE/EX 0737-4 511866” and lighting instructions reference “BAV SE/EX 0717-1 511865”. The appliance must be fitted with a permanent stop on the air inlet to prevent closure beyond the 45% open position. Installation instructions reference “IAV SE/EX 0737-4 511866” and lighting instructions reference “BAV SE/EX 0717-1 511865”. The appliance must be fitted with a permanent stop on the air inlet to prevent closure beyond the 45% open position. Untreated dry wood with less than 20% moisture ⁽¹⁾.
Harrie Leenders Boxer Plus & Boxer Black Wood Burning Stoves. Manufactured by Harrie Leenders Industrieweg 25 5688 DP Oirschot Netherlands. Instruction manual reference “Boxer Plus manual Issue 1” dated January 2014. Instruction manual reference “Boxer Plus manual Issue 1” dated January 2014. Wood logs ⁽¹⁾.
Harrie Leenders Cylon; Harrie Leenders Doran 160; Harrie Leenders Doran 190; Harrie Leenders Fuga S; Harrie Leenders Fuga eL; Harrie Leenders Stor; Harrie Leenders Signa. Manufactured by Harrie Leenders, Industrieweg 25, 5688 DP Oirschot, The Netherlands. Instruction manual reference “Supplementary Instructions Amended June 2010” dated June 2010. The appliance must be fitted with a mechanical stop to prevent closure of the air slide beyond the 15mm open position. Instruction manual reference “Supplementary Instructions Amended June 2010” dated June 2010. The appliance must be fitted with a mechanical stop to prevent closure of the air slide beyond the 15mm open position. Wood logs ⁽¹⁾.
HDG Compact models 25/35 (25kW, 35kW) wood chip and pellet boilers. Manufactured by HDG Bavaria, Gesellschaft mit beschränkter Haftung (GmbH) Siemensstrasse 22, 84323 Massing, Germany. Operating instructions reference “HDG Compact Version V01” dated April 2009. Operating instructions reference “HDG Compact Version V01” dated April 2009. Wood chips or wood pellets ⁽¹⁾.
HDG Compact 45 (45 kW) boiler. Manufactured by HDG Bavaria Gesellschaft mit beschrankter Haftung (GmbH) Siemensstraße 22 D-84323 Massing, Germany. Manual reference “9980001529 V 05.1” dated April 2014 and additional supplementary installation instructions reference “IN1295” dated July 2014. Manual reference “9980001529 V 05.1” dated April 2014 and additional supplementary installation instructions reference “IN1295” dated July 2014. Wood chips or wood pellets ⁽¹⁾.
HDG Compact models 50/65 (50kW, 65kW) wood chip and pellet boilers. Manufactured by HDG Bavaria, Gesellschaft mit beschränkter Haftung (GmbH) Siemensstrasse 22, 84323 Massing, Germany. Operating instructions reference “HDG Compact Version V03” dated April 2009. Operating instructions reference “HDG Compact Version V03” dated April 2009. Wood chips or wood pellets ⁽¹⁾.
HDG Compact model 80 (80kW) wood chip and pellet boiler. Manufactured by HDG Bavaria, Gesellschaft mit beschränkter Haftung (GmbH) Siemensstrasse 22, 84323 Massing, Germany. Operating instructions reference “HDG Compact Version V03” dated April 2009. Operating instructions reference “HDG Compact Version V03” dated April 2009. Wood chips or wood pellets ⁽¹⁾.
HDG Compact 99 (99 kW), 194 (194 kW) and Compact 199 (199 kW) boilers with model HDG 3113 cyclone. Manufactured by HDG Bavaria Gesellschaft mit beschrankter Haftung (GmbH) Siemensstraße 22 D-84323 Massing, Germany. Manual reference “9980001520 V.03.01” dated March 2013 and additional supplementary installation instructions reference “IN1296” dated July 2014. Manual reference “9980001520 V.03.01” dated March 2013 and additional supplementary installation instructions reference “IN1296” dated July 2014. Wood chips or wood pellets ⁽¹⁾.
HDG Compact model 100 (100kW) wood chip and pellet boiler; HDG Compact model 150, 200 (150kW, 200kW) wood chip and pellet boiler with model HDG 3113 cyclone. Manufactured by HDG Bavaria, Gesellschaft mit beschränkter Haftung (GmbH) Siemensstrasse 22, 84323 Massing, Germany. Operating instructions reference “HDG Compact 100-200 Version V1” dated July 2008. Operating instructions reference “HDG Compact 100-200 Version V1” dated July 2008. Wood chips or wood pellets ⁽¹⁾.
HDG Euro models 30, 40 and 50 (30kW, 40kW and 50kW) wood log boilers. Manufactured by HDG Bavaria, Gesellschaft mit beschränkter Haftung (GmbH) Siemensstrasse 22, 84323 Massing, Germany. Operating instructions reference “HDG Euro V3.0 with HDG Lambda Control 1 Version V1” dated June 2008. Operating instructions reference “HDG Euro V3.0 with HDG Lambda Control 1 Version V1” dated June 2008. Split wood logs of 500 mm length and maximum edge length of 120 mm and a residual moisture content of 20% ⁽¹⁾.
HDG K10, K15, K21 and K26 pellet boilers. Manufactured by HDG Bavaria GmbH Heating systems for wood Siemensstraße 22 D-84323 Massing, Germany. Operation manual reference “Manual ref: 99800001036” dated November 2011 and additional supplementary installation instructions K and R Series reference “IN2014” dated January 2014. Operation manual reference “Manual ref: 99800001036” dated November 2011 and additional supplementary installation instructions K and R Series reference “IN2014” dated January 2014. Wood pellets ⁽¹⁾.
HDG Navaro models 20, 25 and 30 (20kW, 25kW and 30kW) wood log boilers. Manufactured by HDG Bavaria, Gesellschaft mit beschränkter Haftung (GmbH) Siemensstrasse 22, 84323 Massing, Germany. Operating instructions reference “HDG Navora 20/25/30 with HDG Lambda Control 1 Version V2” dated June 2008. Operating instructions reference “HDG Navora 20/25/30 with HDG Lambda Control 1 Version V2” dated June 2008. Split wood logs of 500 mm length and maximum edge length of 120 mm and a residual moisture content of 20% ⁽¹⁾.
HDG Pelletmaster model PM15, 15kW wood pellet boiler. Manufactured by HDG Bavaria Gesellschaft mit beschrankter Haftung (GmbH) Siemensstraße 22 D-84323 Massing, Germany. Operating instructions reference “HDG Pelletmaster Version 1” dated October 2006. Operating instructions reference “HDG Pelletmaster Version 1” dated October 2006. Wood pellets ⁽¹⁾.
HDG R20, R25 and R30 wood log boilers. Manufactured by HDG Bavaria GmbH Heating systems for wood, Siemensstraße 22, D-84323 Massing, Germany Manual reference “9980000819” dated August 2011 and additional supplementary installation instructions K and R Series reference “IN2014” dated January 2014. Manual reference “9980000819” dated August 2011 and additional supplementary installation instructions K and R Series reference “IN2014” dated January 2014. Wood logs ⁽¹⁾.
Heat Design TR5c inset stove. Manufactured by Charlton & Jenrick Ltd., Unit D Stafford Park 2, Telford, Shropshire, TF3 3AR. Instruction manual reference “TRc Issue 02” dated April 2012. The appliance must be fitted with a system that prevents closure of the secondary air control slots beyond the 3.5mm open position. Instruction manual reference “TRc Issue 02” dated April 2012. The appliance must be fitted with a system that prevents closure of the secondary air control slots beyond the 3.5mm open position. Wood logs ⁽¹⁾.
Heat Design TR5iT Taper inset stove. Manufactured by Charlton & Jenrick Ltd., Unit D, Stafford Park 2, Telford, Shropshire, TF3 3AR. Instruction manual reference “TRiT Issue 01” dated April 2012. The appliance must be fitted with a system that prevents closure of the secondary air control slots beyond the 5mm open position. Instruction manual reference “TRiT Issue 01” dated April 2012. The appliance must be fitted with a system that prevents closure of the secondary air control slots beyond the 5mm open position. Wood logs ⁽¹⁾.
Heat Design TR6c Wide inset stove. Manufactured by Charlton & Jenrick Ltd., Unit D, Stafford Park 2, Telford, Shropshire, TF3 3AR. Instruction manual reference “TRc Issue 02” dated April 2012. The appliance must be fitted with a system that prevents closure of the secondary air control slots beyond the 9mm open position. Instruction manual reference “TRc Issue 02” dated April 2012. The appliance must be fitted with a system that prevents closure of the secondary air control slots beyond the 9mm open position. Wood logs ⁽¹⁾.
Heat Design of Dublin TR8 Curved Freestanding Wood Burning Stove. Manufactured by Charlton & Jenrick Ltd., Unit D, Stafford Park 2, Telford, Shropshire, TF3 3AR. Instruction manual reference “HD TR Freestanding. Issue 01” dated January 2013. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 5mm open position. Instruction manual reference “HD TR Freestanding. Issue 01” dated January 2013. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 5mm open position. Wood logs ⁽¹⁾.
Heat Design of Dublin TR8c Cassette Inset Wood Burning Stove. Manufactured by Charlton & Jenrick Ltd., Unit D, Stafford Park 2, Telford, Shropshire, TF3 3AR. Instruction manual reference “TRc issue 03” dated July 2012. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 1mm open position. Instruction manual reference “TRc issue 03” dated July 2012. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 1mm open position. Wood logs ⁽¹⁾.
Helios 5 4.6kW multi-fuel stove manufactured by Percy Doughty & Co Limited, Imperial Point, Express Trading Estate, Stone Hill Road, Farnworth, Bolton, BL4 9TN Installation and Operating instructions dated 1st January 2016 reference “HELIOS INSTRUCTION - REV D”. Installation and Operating instructions dated 1st January 2016 reference “HELIOS INSTRUCTION - REV D”. Wood logs⁽¹⁾.
Henley Achill Wood Burning Stove. Manufactured by Henley Stoves Ltd., Ard Ri Marble, Curraheen, Tralee, Co. Kerry, Ireland. Instruction manual reference “Version 1” dated November 2012. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control slots beyond the 50% open position. Instruction manual reference “Version 1” dated November 2012. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control slots beyond the 50% open position. Wood logs ⁽¹⁾.

Reading this document does not replace reading the official text published on legislation.gov.uk. Contains public sector information licensed under the Open Government Licence v3.0. We assume no responsibility for any inaccuracies arising from the conversion of the original CLML XML to this format.

This text is published under legislation.gov.uk's own terms of reuse, not a Legalize or public-domain licence. legislation.gov.uk
Open Government Licence v3.0 (attribution required)