Commission Delegated Regulation (EU) 2020/411 of 19 November 2019 amending Directive 2009/45/EC of the European Parliament and the Council on safety rules and standards for passenger ships, as regards the safety requirements for passenger ships engaged on domestic voyages (Text with EEA relevance)
This is the act as published. Later amendments are not folded into the text below: each one is a separate act in this repository and an entry in this law's history.
- (ii) if the ship is equipped with means for recharging the air cylinders with full pressure with air, free from contamination, the spare storage capacity of the fully charged spare cylinders of each breathing apparatus shall be at least 1 200 litres of free air, and the total spare storage capacity of free air provided in the ship shall not be required to exceed 4 800 litres.
- .2 For each breathing apparatus a fireproof lifeline of sufficient length and strength shall be provided capable of being attached by means of a snaphook to the harness of the apparatus or to a separate belt in order to prevent the breathing apparatus becoming detached when the lifeline is operated.
- .3 New class B and existing class B ships and new class C and D ships of 40 metres in length and above shall carry at least two firefighter’s outfits.
- .1 In ships of 60 metres in length and above, in addition there shall be provided, if the aggregate of the lengths of all passenger spaces and service spaces on the deck which carries such spaces is more than 80 metres, or, if there is more than one such deck, on the deck which has the largest aggregate of such lengths, two firefighter’s outfits and two sets of personal equipment for every 80 metres, or part thereof, of such aggregate of lengths.
In ships carrying more than 36 passengers, two additional firefighter’s outfits shall be provided for each main vertical zone, except for stairway enclosures which constitute individual main vertical zones and for main vertical zones of limited length in the fore and aft end of a ship which do not include accommodation spaces, machinery spaces or main galleys.
- .2 In ships of 40 metres in length and above but less than 60 metres, two firefighter’s outfits have to be provided.
- .3 In new class B and existing class B ships of less than 40 metres in length, also two firefighter’s outfits have to be provided, but with only one spare air charge for self-contained breathing apparatus.
- .4 In class C and D ships of less than 40 metres in length, no firefighter’s outfit has to be provided.
- .4a Fire-fighter’s communication:
| For ships required to carry on board at least one fire-fighter outfit and constructed on or after 1 January 2018, a minimum of two two-way portable radiotelephone apparatus for each fire party for fire-fighter’s communication shall be carried on board. For LNG fuelled ships or Ro-Ro passenger ships with closed Ro-Ro spaces or special category spaces, those two-way portable radiotelephone apparatus shall be of an explosion-proof type or intrinsically safe. Ships constructed before 1 January 2018 shall comply with the requirements of this Regulation II-2/A/11 not later than the first survey after 1 July 2019. |
- .5 The firefighter’s outfits or sets of personal equipment shall be so stored as to be easily accessible and ready for use and, where more than one fire-fighter’s outfit or more than one set of personal equipment is carried, they shall be stored in widely separated positions. At least one firefighter’s outfit and one set of personal equipment shall be available at any one such position.
- .6 When the Administration of a flag State considers that the carriage provisions in this Regulation II-2/A/11 are unreasonable and/or technically unsuitable on board a ship, such ship may, in compliance with the provisions in Article 9(3) of Directive 2009/45/EC, be exempted from one or more of the requirements in this Regulation II-2/A/11.
12. Regulation II-2/A/12: Miscellaneous items (R 18)
NEW CLASS B, C AND D AND EXISTING CLASS B SHIPS:
- .1 Where class ‘A’ divisions are penetrated for the passage of electric cables, pipes, trunks, ducts etc., or for girders, beams or other structural members, arrangements shall be made to ensure that the fire resistance is not impaired in so far as is reasonable and practicable.
For ships which are constructed on or after 1 January 2003, where ‘A’ class divisions are penetrated, such penetrations shall be tested in accordance with the Fire Test Procedures Code, to ensure that the fire resistance of the divisions is not impaired.
In the case of ventilation ducts, Regulation II-2/B/9, subparagraph.1.4; Regulation II-2/B/9, subparagraph.2.2a; Regulation II-2/B/9, subparagraph.2.2b; Regulation II-2/B/9, point.3; Regulation II-2/B/9a, subparagraph.1.2; and Regulation II-2/B/9a, subparagraph.3.1 apply as appropriate.
However, where a pipe penetration is made of steel or equivalent material having a thickness of 3 mm or greater and a length of not less than 900 mm (preferably 450 mm on each side of the division) and no openings, testing is not required.
Such penetrations shall be suitably insulated by extension of the insulation at the same level of the division.
- .2 Where class ‘B’ divisions are penetrated for the passage of electric cables, pipes, trunks, ducts etc., or for the fitting of ventilation terminals, lighting fixtures and similar devises, arrangements shall be made to ensure that the fire resistance is not impaired in so far as is reasonable and practicable. In ships which are constructed on or after 1 January 2003 for such penetrations arrangements shall be made to ensure that the fire resistance of the divisions is not impaired.
Pipes other than steel or copper that penetrate ‘B’ class divisions shall be protected by either:
- .1 a fire tested penetration device, suitable for the fire resistance of the division pierced and the type of the pipe used; or
- .2 a steel sleeve, having a thickness of not less than 1,8 mm and a length of not less than 900 mm for pipe diameters of 150 mm or more and not less than 600 mm for pipe diameters of less than 150 mm (preferably equally divided to each side of the division).
The pipe shall be connected to the ends of the sleeve by flanges or couplings or the clearance between the sleeve and the pipe shall not exceed 2,5 mm or any clearance between pipe and sleeve shall be made tight by means of non-combustible or other suitable material.
- .3 Pipes penetrating ‘A’ or ‘B’ class divisions shall be of approved materials having regard to the temperature such divisions are required to withstand.
In ships constructed on or after 1 January 2003, non-insulated metallic pipes penetrating ‘A’ or ‘B’ class divisions shall be of materials having a melting temperature which exceeds 950 °C for ‘A-0’ and 850 °C for ‘B-0’ class divisions.
- .4 In accommodation spaces, service spaces or control stations, pipes intended to convey oil or other flammable liquids shall be of a suitable material and construction having regard to the fire risk.
- .5 Materials readily rendered ineffective by heat shall not be used for over board scuppers, sanitary discharges, and other outlets which are close to the waterline and where the failure of the material in the event of fire would give rise to danger of flooding.
- .6 Electric radiators, if used, shall be fixed in position and so constructed as to reduce fire risks to a minimum. No such radiators shall be fitted with an element so exposed that clothing, curtains, or other similar materials can be scorched or set on fire by heat from the element.
- .7 All waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom.
- .8 In spaces where penetration of oil products is possible, the surface of insulation shall be impervious to oil or oil vapours.
NEW CLASS A, B, C AND D SHIPS: In spaces in which there is a risk of oils splashing or oil vapour, e.g. in machinery spaces of category A, the surface of the insulating material shall be impermeable by oil and oil vapour. Where there is covering by non-perforated steel plate or other non-combustible materials (not aluminium) which is the ultimate physical surface, this covering may be joined by seaming, riveting, etc.
- .9 Paint lockers and flammable liquid lockers shall be protected by an approved fire-extinguishing arrangement, enabling the crew to extinguish a fire without entering the space.
In ships which are constructed on or after 1 January 2003:
- .1 Paint lockers shall be protected by one of the following systems:
- .1.1 a carbon dioxide system, designed to give a minimum volume of free gas equal to 40 % of the gross volume of the protected space;
- .1.2 a dry powder system, designed for at least 0,5 kg powder/m3;
- .1.3 a waterspraying or sprinkler system, designed for 5 litres/m2 min. Water spraying systems may be connected to the fire main of the ship; or
- .1.4 a system providing equivalent protection, as determined by the Administration of the flag State.
In any case the system shall be operable from outside the protected space.
- .2 Flammable liquid lockers shall be protected by an appropriate fire extinguishing arrangement approved by the Administration of the flag State.
- .3 For lockers of a deck area of less than 4 m2, which do not give access to accommodation spaces, a carbon dioxide portable extinguisher sized to provide a minimum volume of free gas equal to 40 % of the gross volume of the space may be accepted in lieu of a fixed system.
A discharge port shall be arranged in the locker to allow the discharge of the extinguisher without having to enter into the protected space. The required portable fire extinguisher shall be stowed adjacent to the port. Alternatively, a port or hose connection may be provided to facilitate the use of fire main water.
NEW CLASS A, B, C AND D SHIPS AND EXISTING CLASS B SHIPS:
- .10 Deep-fat friers, boiling and roasting apparatus:
When deep-fat friers, boiling and roasting apparatus are installed and used in spaces outside the main galley, the Administration of the flag State shall impose additional safety measures with regard to the specific fire hazards associated with the use of this type of equipment.
In ships which are constructed on or after 1 January 2003, deep-fat cooking equipment shall be fitted with the following:
- .1 an automatic or manual extinguishing system tested to an international standard in accordance with Publication ISO 15371:2000 on fire-extinguishing systems for protection of galley deep-fat cooking equipment;
- .2 a primary and backup thermostat with an alarm to alert the operator in the event of failure of either thermostat;
- .3 arrangements for automatically shutting off the electrical power upon activation of the extinguishing system;
- .4 an alarm for indicating operation of the extinguishing system in the galley where the equipment is installed; and
- .5 controls for manual operation of the extinguishing system, which are clearly labelled for ready use of the crew.
In ships which are constructed before 1 January 2003, new installations for deep-fat cooking equipment shall comply with the requirements of this paragraph.
NEW CLASS A, B, C AND D SHIPS:
- .11 Heat bridges:
In the implementation of fire proofing measures, steps shall be undertaken by the Administration of the flag State to prevent heat transfer through heat bridges, e.g. between decks and bulkheads.
In ships which are constructed on or after 1 January 2003, the insulation of a deck or bulkhead shall be carried past the penetration, intersection or terminal point for a distance of at least 450 mm in the case of steel and aluminium structures. If a space is divided with a deck or a bulkhead of ‘A’ class standard having insulation of different values, the insulation with the higher value shall continue on the deck or bulkhead with the insulation of the lesser value for a distance of at least 450 mm.
NEW CLASS A, B, C AND D SHIPS AND EXISTING CLASS B SHIPS:
- .12 Pressurised gas containers:
All portable containers for gases which are compressed, liquefied or broken down under pressure, which may feed a possible fire, shall immediately after use be put in a suitable place above the bulkhead deck, from which there is direct access to open deck.
13. Regulation II-2/A/13: Fire control plans (R 20)
NEW CLASS B, C AND D AND EXISTING CLASS B SHIPS:
- .1 In all ships general arrangement plans shall be permanently exhibited for the guidance of the ship’s officers, showing clearly for each deck the control stations, the various fire sections enclosed by ‘A’ class divisions, the sections enclosed by ‘B’ class divisions together with particulars of the fire detection and fire alarm systems, the sprinkler installation, the fire-extinguishing appliances, means of access to different compartments, decks, etc. and the ventilating system including particulars of the fan control positions, the position of dampers and identification numbers of the ventilating fans serving each section. Alternatively, the aforementioned details may be set out in a booklet, a copy of which shall be supplied to each officer, and one copy shall at all times be available on board in an accessible position. Plans and booklets shall be kept up to date, any alterations being recorded thereon as soon as practicable. Description in such plans and booklets shall be in the official language of the flag State. If the language is neither English nor French, a translation into one of these languages shall be included. In the case the ship is engaged on domestic voyages in another Member State, a translation into the official language of that port State, if this language is neither English nor French, shall be included.
For new class B, C and D ships constructed on or after 1 January 2003, the information to be provided with the required fire control plans and booklets and the graphical symbols to be used for the fire control plans shall be in accordance with the IMO Resolutions A.756(18) and A.952(23).
- .2 A duplicate set of fire control plans or a booklet containing such plans shall be permanently stored in a prominently marked weather tight enclosure outside the deckhouse for the assistance of shore side fire-fighting personnel.
14. Regulation II-2/A/14: Operational readiness and maintenance
NEW CLASS B, C AND D AND EXISTING CLASS B SHIPS:
- .1 General requirements
At all times while the ship is in service, the fire protection systems and fire-fighting systems and appliances shall be maintained ready for use.
A ship is not in service when:
- .1 it is in for repairs or lay-up (either at anchor or at port) or in dry-dock;
- .2 it is declared not in service by the owner or the owner’s representative; and
- .3 if there are no passengers on board.
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs:
- .1.1 Operational readiness
- .1 structural fire protection including fire resisting divisions and protection of openings and penetrations in these divisions;
- .2 fire detection and fire alarm systems; and
- .3 means of escape systems and appliances.
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Portable extinguishers which have been discharged shall be immediately recharged or replaced with an equivalent unit.
- .1.2 Maintenance, testing and inspections
Maintenance, testing and inspections shall be carried out based on the guidelines in IMO MSC/Circ.850 and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. A maintenance plan shall be kept on board the ship and shall be available for inspection, whenever required by the Administration of the flag State.
The maintenance plan shall include at least the following fire protection systems and fire-fighting systems and appliances, where installed:
- .1 fire mains, fire pumps and hydrants including hoses and nozzles;
- .2 fixed fire detection and fire alarm systems;
- .3 fixed fire-extinguishing systems and other fire-extinguishing appliances;
- .4 automatic sprinkler, fire detection and fire alarm systems;
- .5 ventilation systems including fire and smoke dampers, fans and their controls;
- .6 emergency shut down of fuel supply;
- .7 fire doors including their controls;
- .8 general emergency alarm systems;
- .9 emergency escape breathing devices;
- .10 portable fire extinguishers including spare charges; and
- .11 firefighter’s outfits.
The maintenance programme may be computer-based.
- .2 Additional requirements
For new class B, C and D ships constructed on or after 1 January 2003 carrying more than 36 passengers, a maintenance plan for low-location lighting and public address systems shall be developed in addition to the maintenance plan mentioned under paragraph.1.2.
15. Regulation II-2/A/15: Instructions, on-board training and drills
NEW CLASS B, C AND D AND EXISTING CLASS B SHIPS:
- .1 Instructions, duties and organisation
- .1 Crew members shall receive instructions on fire safety on-board the ship.
- .2 Crew members shall receive instructions on their assigned duties.
- .3 Parties responsible for fire extinguishing shall be organised. These parties shall have the capability to complete their duties at all times while the ship is in service.
- .2 On-board training and drills
- .1 Crew members shall be trained to be familiar with the arrangements of the ship as well as the location and operation of any fire-fighting systems and appliances that they may be called upon to use.
- .2 Training in the use of the emergency escape breathing devices shall be considered as a part of on-board training.
- .3 Performance of crew members assigned fire-fighting duties shall be periodically evaluated by conducting on-board training and drills to identify areas in need of improvement, to ensure competency in fire-fighting skills is maintained and to ensure the operational readiness of the fire-fighting organisation.
- .4 On-board training in the use of the ship’s fire-extinguishing systems and appliances shall be planned and conducted in accordance with provisions of Regulation III/19.4.1 of SOLAS 1974, as amended.
- .5 Fire drills shall be conducted and recorded in accordance with the provisions of Regulations III/19.3.5, III/19.5 and III/30 of SOLAS 1974, as amended.
- .6 In ships subject to Regulation II-2/A/11, breathing apparatus cylinders used during drills shall be refilled or replaced before departure.
- .3 Training manuals
A training manual shall be provided in each crew mess room and recreation room or in each crew cabin. The training manual shall be written in the working language of the ship. The training manual, which may comprise several volumes, shall contain the instructions and the information required in this paragraph in easily understood terms and illustrated wherever possible. Any part of such information may be provided in the form of audiovisual aides in lieu of the manual. The training manual shall explain the following in detail:
- .1 general fire safety practice and precautions related to the dangers of smoking, electrical hazards, flammable liquids and similar common shipboard hazards;
- .2 general instructions on fire-fighting activities and fire-fighting procedures including procedures for notification of a fire and use of manually operated call points;
- .3 meanings of ship’s alarms;
- .4 operation and use of fire-fighting systems and appliances;
- .5 operation and use of fire doors;
- .6 operation and use of fire and smoke dampers; and
- .7 escape systems and appliances.
- .4 Fire control plans
Fire control plans have to comply with the requirements of Regulation II-2/A/13.
16. Regulation II-2/A/16: Operations
NEW CLASS B, C, D AND EXISTING CLASS B SHIPS:
- .1 To provide information and instruction for proper ship and cargo handling operations in relation to fire safety, operational booklets shall be provided on board.
- .2 The required fire operational booklet shall contain the necessary information and instructions for the safe operation of the ship and cargo handling operations in relation to fire safety. The booklet shall include information concerning the crew’s responsibilities for the general fire safety of the ship while loading and discharging cargo and while underway. For ships carrying dangerous goods, the fire safety booklet shall provide reference to the pertinent fire-fighting and emergency cargo handling instructions contained in the International Maritime Dangerous Goods Code.
- .3 The fire safety operational booklet shall be written in the working language of the ship.
- .4 The fire safety operational booklet may be combined with the training manuals required in Regulation II-2/A/15, paragraph.3.
PART B
FIRE SAFETY MEASURES
1. Regulation II-2/B/1: Structure (R 23)
NEW CLASS B, C AND D AND EXISTING CLASS B SHIPS:
- .1 The hull, superstructures, structural bulkheads, decks and deckhouses shall be constructed of steel or other equivalent material. For the purpose of applying the definition of other equivalent material as given in article 2 (za) of Directive 2009/45/EC, the ‘applicable fire exposure’ shall be according to the integrity and insulation standards given in the tables of Regulations II-2/B/4 and II-2/B/5. For example, where divisions such as decks or sides and ends of deckhouses are permitted to have ‘B-0’ fire integrity, the ‘applicable fire exposure’ shall be half an hour.
- .2 However, in cases where any part of the structure is of aluminium alloy, the following shall apply:
- .1 The insulation of aluminium alloy components of ‘A’ or ‘B’ class divisions, except structure which is non-load-bearing, shall be such that the temperature of the structural core does not rise more than 200 °C above the ambient temperature at any time during the applicable fire exposure to the standard fire test.
- .2 Special attention shall be given to the insulation of aluminium alloy components of columns, stanchions and other structural members required to support lifeboat and life-raft stowage, launching and embarkation areas, and ‘A’ and ‘B’ class divisions to ensure:
- .1 that for such members supporting lifeboat and life-raft areas and ‘A’ class divisions, the temperature rise limitation specified in paragraph.2.1 shall apply at the end of one hour; and
- .2 that for such members required to support ‘B’ class divisions, the temperature rise limitation specified in paragraph.2.1 shall apply at the end of half an hour.
- .3 Crowns and casings of category A machinery spaces shall be of steel construction adequately insulated and openings therein, if any, shall be suitably arranged and protected to prevent the spread of fire.
2. Regulation II-2/B/2: Main vertical zones and horizontal zones (R 24)
NEW CLASS B, C AND D SHIPS:
- .1.1 In ships carrying more than 36 passengers, the hull, superstructure and deckhouses shall be subdivided into main vertical zones by A-60 class divisions.
Steps and recesses shall be kept to a minimum but, where they are necessary, they shall also be A-60 class divisions.
Where an open deck space, a sanitary or similar space or a tank including a fuel oil tank, void space or auxiliary machinery space having little or no fire risk, is on one side or where fuel oil tanks are on both sides of the division, the standard may be reduced to A-0.
NEW CLASS B, C AND D AND EXISTING CLASS B SHIPS:
- .1.2 For new class B, C and D ships carrying not more than 36 passengers and for existing class B ships carrying more than 36 passengers, the hull, superstructure and deckhouses in way of accommodation and service spaces shall be subdivided into main vertical zones by ‘A’ class divisions. These divisions shall have insulation values in accordance with the tables in Regulation II-2/B/5.
NEW CLASS B, C AND D SHIPS:
- .2 As far as practicable, the bulkheads forming the boundaries of the main vertical zones above the bulkhead deck shall be in line with watertight subdivision bulkheads situated immediately below the bulkhead deck. The length and width of main vertical zones may be extended to a maximum of 48 metres in order to bring the ends of main vertical zones to coincide with subdivision watertight bulkheads or in order to accommodate a large public space extending for the whole length of the main vertical zone provided that the total area of the main vertical zone is not greater than 1 600 m2 on any deck. The length or width of a main vertical zone is the maximum distance between the furthermost points of the bulkheads bounding it.
NEW CLASS B, C AND D SHIPS AND EXISTING CLASS B SHIPS CARRYING MORE THAN 36 PASSENGERS:
- .3 Such bulkheads shall extend from deck to deck and to the shell or other boundaries.
- .4 Where a main vertical zone is subdivided by horizontal ‘A’ class divisions into horizontal zones for the purpose of providing an appropriate barrier between sprinkled and non-sprinklered zones of the ship, the divisions shall extend between adjacent main vertical zone bulkheads and to the shell or exterior boundaries of the ship and shall be insulated in accordance with the fire insulation and integrity values given in table 4.2 for new ships carrying more than 36 passengers, and existing class B ships carrying more than 36 passengers.
- .5 - .1 On ships designed for special purposes, such as automobile or railroad car ferries where the provision of main vertical zone bulkheads would defeat the purpose for which the ship is intended, equivalent protection shall be obtained by dividing space in horizontal zones.
- .2 However, in a ship with special category spaces, any such space shall comply with the applicable provisions of Regulation II-2/B/14 and in so far as such compliance would be inconsistent with compliance with other requirements of this part, the requirements of Regulation II-2/B/14 shall prevail.
3. Regulation II-2/B/3: Bulkheads within a main vertical zone (R 25)
NEW CLASS B, C AND D SHIPS CARRYING MORE THAN 36 PASSENGERS:
- .1.1 For new ships carrying more than 36 passengers all bulkheads which are not required to be ‘A’ class divisions shall be at least ‘B’ class or ‘C’ class divisions as prescribed in the tables in Regulation II-2/B/4. All such divisions may be faced with combustible materials in accordance with the provisions of Regulation II-2/B/11.
NEW CLASS B, C AND D SHIPS CARRYING NOT MORE THAN 36 PASSENGERS AND EXISTING CLASS B SHIPS CARRYING MORE THAN 36 PASSENGERS:
- .1.2 For new ships carrying not more than 36 passengers and existing class B ships carrying more than 36 passengers all bulkheads within accommodation and service spaces which are not required to be ‘A’ class divisions shall be at least ‘B’ class or ‘C’ class divisions as prescribed in the tables in Regulation II-2/B/5.
All such divisions may be faced with combustible materials in accordance with the provisions of Regulation II-2/B/11.
NEW CLASS B, C AND D AND EXISTING CLASS B SHIPS:
- .2 In new class B, C and D ships carrying not more than 36 passengers and in existing class B ships carrying more than 36 passengers all corridor bulkheads, where not required to be ‘A’ class, shall be ‘B’ class divisions which shall extend from deck to deck except:
- .1 when continuous ‘B’ class ceilings or linings are fitted on both sides of the bulkhead, the portion of the bulkhead behind the continuous ceiling or lining shall be of material which, in thickness and composition, is acceptable in the construction of ‘B’ class divisions, but which shall be required to meet ‘B’ class integrity standards only in so far as is reasonable and practicable;
- .2 in the case of a ship protected by an automatic sprinkler system complying with the provisions of Regulation II-2/A/8, the corridor bulkheads of ‘B’ class materials may terminate at a ceiling in the corridor provided such ceiling is of material which, in thickness and composition, is acceptable in the construction of ‘B’ class divisions.
Notwithstanding the requirements of Regulations II-2/B/4 and II-2/B/5, such bulkheads and ceilings shall be required to meet ‘B’ class integrity standards only in so far as is reasonable and practicable. All doors and frames in such bulkheads shall be of non-combustible materials and shall be so constructed and erected as to provide substantial fire resistance.
- .3 All bulkheads required to be ‘B’ class division, except corridor bulkheads prescribed in paragraph.2, shall extend from deck to deck and to the shell or other boundaries unless the continuous ‘B’ class ceilings or linings fitted on both sides of the bulkheads are at least of the same fire resistance as the bulkhead, in which case the bulkhead may terminate at the continuous ceiling or lining.
4. Regulation II-2/B/4: Fire integrity of bulkheads and decks in new ships carrying more than 36 passengers (R 26)
NEW CLASS B, C AND D SHIPS:
- .1 In addition to complying with the specific provisions for fire integrity of bulkheads and decks mentioned elsewhere in this part, the minimum fire integrity of all bulkheads and decks shall be as prescribed in tables 4.1 and 4.2.
- .2 The following requirements shall govern the application of the tables:
- .1 Table 4.1 shall apply to bulkheads not bounding either main vertical zones or horizontal zones.
Table 4.2 shall apply to decks not forming steps in main vertical zones nor bounding horizontal zones.
- .2 For determining the appropriate fire integrity standards to be applied to boundaries between adjacent spaces, such spaces are classified according to their fire risk as shown in categories (1) to (14). Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this Regulation II-2/B/4, it shall be treated as a space within the relevant category having the most stringent boundary requirements. The title of each category is intended to be typical rather than restrictive. The number in parentheses preceding each category refers to the applicable column or row in the tables.
- (1) Control stations:
- — spaces containing emergency sources of power and lighting,
- — wheelhouse and chartroom,
- — spaces containing the ship’s radio equipment,
- — fire-extinguishing rooms, fire control rooms and fire-recording stations,
- — control room for propulsion machinery when located outside the propulsion machinery space,
- — spaces containing centralised fire alarm equipment,
- — spaces containing centralised emergency public address system stations and equipment.
- (2) Stairways:
- — interior stairways, lifts and escalators (other than those wholly contained within the machinery spaces) for passengers and crew and enclosures thereto;
- — in this connection a stairway which is enclosed at only one level shall be regarded as part of the space from which it is not separated by a fire door.
- (3) Corridors:
- — passenger and crew corridors.
- (4) Evacuation stations and external escape routes:
- — survival craft stowage area,
- — open deck spaces and enclosed promenades forming lifeboat and life-raft embarkation and lowering stations,
- — assembly stations, internal and external,
- — external stairs and open decks used for escape routes,
- — the ship’s side to the waterline in the lightest seagoing condition, superstructure and deckhouse sides situated below and adjacent to the life-rafts and evacuation slide’s embarkation areas.
- (5) Open deck spaces:
- — open deck spaces and enclosed promenades clear of lifeboat and life-raft embarkation and lowering stations,
- — air spaces (the space outside superstructures and deckhouses).
- (6) Accommodation spaces of minor fire risk:
- — cabins containing furniture and furnishing of restricted fire risk,
- — offices and dispensaries containing furniture and furnishings of restricted fire risk,
- — public spaces containing furniture and furnishings of restricted fire risk and having a deck area of less than 50 m2.
- (7) Accommodation spaces of moderate fire risk:
- — spaces as in category (6) above but containing furniture and furnishing of other than restricted fire risk,
- — public spaces containing furniture and furnishing of restricted fire risk and having a deck area of 50 m2 or more,
- — isolated lockers and small storerooms in accommodation spaces having areas less than 4 m2 (in which flammable liquids are not stowed),
- — sale shops,
- — motion picture projection and film stowage rooms,
- — diet kitchens (containing no open flame),
- — cleaning gear lockers (in which flammable liquids are not stowed),
- — laboratories (in which flammable liquids are not stowed),
- — pharmacies,
- — small drying rooms (having a deck area of 4 m2 or less),
- — specie rooms,
- — operating rooms.
- (8) Accommodation spaces of greater fire risk:
- — public spaces containing furniture and furnishing of other than restricted fire risk and having a deck area of 50 m2 or more,
- — barber shops and beauty parlours.
- (9) Sanitary and similar spaces:
- — communal sanitary facilities, shower, baths, water closets, etc.,
- — small laundry rooms,
- — indoor swimming pool area,
- — isolated pantries containing no cooking appliances in accommodation spaces,
- — private sanitary facilities shall be considered a portion of the space in which they are located.
- (10) Tanks, voids and auxiliary machinery spaces having little or no fire risk:
- — water tanks forming part of the ship’s structure;
- — voids and cofferdams;
- — auxiliary machinery spaces which do not contain machinery having a pressure lubrication system and where storage of combustibles is prohibited, such as;
- — ventilation and air-conditioning rooms; windlass room; steering gear room; stabiliser equipment room; electrical propulsion motor room; rooms containing section switchboards and purely electrical equipment other than oil-filled electrical transformers (above 10 kVA); shaft alleys and pipe tunnels; spaces for pumps and refrigeration machinery (not handling or using flammable liquids),
- — closed trunks serving the spaces listed above,
- — other closed trunks such as pipe and cable trunks.
- (11) Auxiliary machinery spaces, cargo spaces, cargo and other oil tanks and other similar spaces of moderate fire risk:
- — cargo oil tanks,
- — cargo holds, trunkways and hatchways,
- — refrigerated chambers,
- — oil fuel tanks (where installed in a separate space with no machinery),
- — shaft alleys and pipe tunnels allowing storage of combustibles,
- — auxiliary machinery spaces as in category (10) which contain machinery having a pressure lubrication system or where storage of combustibles is permitted,
- — oil fuel filling stations,
- — spaces containing oil-filled electrical transformers (above 10 kVA),
- — spaces containing small internal combustion engines of power output up to 110 kW driving generators, sprinkler, drencher or fire pumps, bilge pumps, etc.,
- — closed trunks serving the spaces listed above.
- (12) Machinery spaces and main galleys:
- — main propulsion machinery rooms (other than electric propulsion motor rooms) and boiler rooms,
- — auxiliary machinery spaces other than those in categories (10) and (11) which contain internal combustion machinery or other oil burning, heating or pumping units,
- — main galleys and annexes,
- — trunks and casings to the spaces listed above.
- (13) Store-rooms, workshops, pantries, etc.:
- — main pantries not annexed to galleys,
- — main laundry,
- — large drying rooms (having a deck area of more than 4 m2),
- — miscellaneous stores,
- — mail and baggage rooms,
- — garbage rooms,
- — workshops (not part of machinery spaces, galleys, etc.),
- — lockers and storerooms having areas greater than 4 m2, other than those spaces that have provisions for the storage of flammable liquids.
- (14) Other spaces in which flammable liquids are stowed:
- — paint lockers,
- — store-rooms containing flammable liquids (including dyes, medicines, etc.),
- — laboratories (in which flammable liquids are stowed).
- .3 Where a single value is shown for the fire integrity of a boundary between two spaces, that value shall apply in all cases.
- .4 There are no special requirements for material or integrity of boundaries where only a dash appears in the tables.
- .5 The Administration of the flag State shall determine in respect of category (5) spaces whether the insulation values in table 4.1 shall apply to ends of deckhouses and superstructures, and whether the insulation values in table 4.2 shall apply to weather decks. In no case shall the requirements of category (5) of table 4.1 or 4.2 necessitate enclosure of spaces which in the opinion of the Administration of the flag State need not be enclosed.
- .3 Continuous ‘B’ class ceiling or linings, in association with the relevant decks or bulkheads, may be accepted as contributing wholly or in part, to the required insulation and integrity of a division.
- .4 In approving structural fire protection details the Administration of the flag State shall have regard to the risk of heat transmission at intersections and terminal points of required thermal barriers.
Table 4.1
Bulkheads not bounding either main vertical zones or horizontal zones
| Spaces | Spaces | (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | (10) | (11) | (12) | (13) | (14) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Control stations | (1) | B-0 (a) | A-0 | A-0 | A-0 | A-0 | A-60 | A-60 | A-60 | A-0 | A-0 | A-60 | A-60 | A-60 | A-60 |
| Stairways | (2) | A-0 (a) | A-0 | A-0 | A-0 | A-0 | A-15 | A-15 | A-0 (c) | A-0 | A-15 | A-30 | A-15 | A-30 | |
| Corridors | (3) | B-15 | A-60 | A-0 | B-15 | B-15 | B-15 | B-15 | A-0 | A-15 | A-30 | A-0 | A-30 | ||
| Evacuation stations and external escape routes | (4) | A-0 | A-60 (b,d) | A-60 (b,d) | A-60 (b,d) | A-0 (d) | A-0 | A-60 (b) | A-60 (b) | A-60 (b) | A-60 (b) | ||||
| Open deck spaces | (5) | — | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | ||||
| Accommodation spaces of minor fire risk | (6) | B-0 | B-0 | B-0 | C | A-0 | A-0 | A-30 | A-0 | A-30 | |||||
| Accommodation spaces of moderate fire risk | (7) | B-0 | B-0 | C | A-0 | A-15 | A-60 | A-15 | A-60 | ||||||
| Accommodation spaces of greater fire risk | (8) | B-0 | C | A-0 | A-30 | A-60 | A-15 | A-60 | |||||||
| Sanitary and similar spaces | (9) | C | A-0 | A-0 | A-0 | A-0 | A-0 | ||||||||
| Tanks, voids and auxiliary machinery spaces having little or no fire risk | (10) | A-0 (a) | A-0 | A-0 | A-0 | A-0 | |||||||||
| Auxiliary machinery spaces, cargo spaces, cargo and other oil tanks and other similar spaces of moderate fire risk | (11) | A-0 (a) | A-0 | A-0 | A-15 | ||||||||||
| Machinery spaces and main galleys | (12) | A-0 (a) | A-0 | A-60 | |||||||||||
| Storerooms, workshops, pantries, etc. | (13) | A-0 (a) | A-0 | ||||||||||||
| Other spaces in which flammable liquids are stowed | (14) | A-30 |
Table 4.2
Decks neither forming steps in main vertical zones nor bounding horizontal zones
| Space below↓ Space above→ | Space below↓ Space above→ | (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | (10) | (11) | (12) | (13) | (14) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Control stations | (1) | A-30 | A-30 | A-15 | A-0 | A-0 | A-0 | A-15 | A-30 | A-0 | A-0 | A-0 | A-60 | A-0 | A-60 |
| Stairways | (2) | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-30 | A-0 | A-30 |
| Corridors | (3) | A-15 | A-0 | A-0 (a) | A-60 | A-0 | A-0 | A-15 | A-15 | A-0 | A-0 | A-0 | A-30 | A-0 | A-30 |
| Evacuation stations and external escape routes | (4) | A-0 | A-0 | A-0 | A-0 | — | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 |
| Open deck spaces | (5) | A-0 | A-0 | A-0 | A-0 | — | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 |
| Accommodation spaces of minor fire risk | (6) | A-60 | A-15 | A-0 | A-60 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 |
| Accommodation spaces of moderate fire risk | (7) | A-60 | A-15 | A-15 | A-60 | A-0 | A-0 | A-15 | A-15 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 |
| Accommodation spaces of greater fire risk | (8) | A-60 | A-15 | A-15 | A-60 | A-0 | A-15 | A-15 | A-30 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 |
| Sanitary and similar spaces | (9) | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 |
| Tanks, voids and auxiliary machinery spaces having little or no fire risk | (10) | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 (a) | A-0 | A-0 | A-0 | A-0 |
| Auxiliary machinery spaces, cargo spaces, cargo and other oil tanks and other similar spaces of moderate fire risk | (11) | A-60 | A-60 | A-60 | A-60 | A-0 | A-0 | A-15 | A-30 | A-0 | A-0 | A-0 (a) | A-0 | A-0 | A-30 |
| Machinery spaces and main galleys | (12) | A-60 | A-60 | A-60 | A-60 | A-0 | A-60 | A-60 | A-60 | A-0 | A-0 | A-30 | A-30 (a) | A-0 | A-60 |
| Storerooms, workshops, pantries, etc. | (13) | A-60 | A-30 | A-15 | A-60 | A-0 | A-15 | A-30 | A-30 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 |
| Other spaces in which flammable liquids are stowed | (14) | A-60 | A-60 | A-60 | A-60 | A-0 | A-30 | A-60 | A-60 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 |
Notes to be applied to tables 4.1 and 4.2
- (a) Where adjacent spaces are in the same numerical category and superscript ‘a’ appears, a bulkhead or deck between such spaces need not to be fitted if deemed unnecessary by the Administration of the flag State. For example, in category (12) a bulkhead need not be required between a galley and its annexed pantries provided the pantry bulkhead and decks maintain the integrity of the galley boundaries. A bulkhead is, however, required between a galley and a machinery space even though both spaces are in category (12).
- (b) The ship’s side, to the waterline in the lightest seagoing condition, superstructure and deckhouse sides situated below and adjacent to the life-rafts and evacuation slides may be reduced to ‘A-30’.
- (c) Where public toilets are installed completely within the stairway enclosure, the public toilet bulkhead within the stairway enclosure can be of ‘B’ class integrity.
- (d) Where spaces of categories (6), (7), (8) and (9) are located completely within the outer perimeter of the assembly station, the bulkheads of these spaces are allowed to be of ‘B-0’ class integrity. Control positions for audio, video and light installations may be considered as part of the assembly station.
5. Regulation II-2/B/5: Fire integrity of bulkheads and decks in new ships carrying not more than 36 passengers and existing class B ships carrying more than 36 passengers (R 27)
NEW CLASS B, C, AND D SHIPS CARRYING NOT MORE THAN 36 PASSENGERS AND EXISTING CLASS B SHIPS CARRYING MORE THAN 36 PASSENGERS:
- .1 In addition to complying with the specific provisions for fire integrity of bulkheads and decks mentioned elsewhere in this part, the minimum fire integrity of bulkheads and decks shall be as prescribed in tables 5.1 or 5.1(a), and 5.2 or 5.2(a), as appropriate.
When approving structural precautions for fire protection in new ships, account shall be taken of the risk of heat transfer between heat bridges at intersection points and of where the thermal barring devices terminate.
- .2 The following requirements shall govern application of the tables:
- .1 Tables 5.1 and 5.2 shall apply respectively to the bulkheads and decks separating adjacent spaces.
- .2 For determining the appropriate fire integrity standards to be applied to divisions between adjacent spaces, such spaces are classified according to their fire risk as shown in categories (1) to (11) below. The title of each category is intended to be typical rather than restrictive. The number in parentheses preceding each category refers to the applicable column or row in the tables.
- (1) Control stations:
- — spaces containing emergency sources of power and lighting,
- — wheelhouse and chartroom,
- — spaces containing the ship’s radio equipment,
- — fire-extinguishing rooms, fire control rooms and fire-recording stations,
- — control room for propulsion machinery when located outside the propulsion machinery space,
- — spaces containing centralised fire alarm equipment.
- (2) Corridors:
- — passenger and crew corridors and lobbies.
- (3) Accommodation spaces:
- — spaces as defined in Regulation II-2/A/2, paragraph.10 excluding corridors.
- (4) Stairways:
- — interior stairways, lifts and escalators (other than those wholly contained within the machinery spaces) and enclosures thereto,
- — in this connection, a stairway which is enclosed only at one level shall be regarded as part of the space from which it is not separated by a fire door.
- (5) Service spaces (low risk):
- — lockers and storerooms not having provisions for the storage of flammable liquids and having areas less than 4 m2 and drying rooms and laundries.
- (6) Machinery spaces of category A:
- — spaces as defined in Regulation II-2/A/2, subparagraph.19.1.
- (7) Other machinery spaces:
- — spaces as defined in Regulation II-2/A/2, subparagraph.19.2, excluding machinery spaces of category A.
- (8) Cargo spaces:
- — all spaces used for cargo (including cargo oil tanks) and trunkways and hatchways to such spaces, other than special category spaces.
- (9) Service spaces (high risk):
- — galleys, pantries containing cooking appliances, paint and lamp rooms, lockers and storerooms having areas of 4 m2 or more, spaces for the storage of flammable liquids, and workshops other than those forming part of the machinery spaces.
- (10) Open decks:
- — open deck spaces and enclosed promenades having no fire risk. Air spaces (the space outside superstructures and deckhouses).
- (11) Special category spaces:
- — spaces as defined in Regulation II-2/A/2, paragraph.18.
- .3 In determining the applicable fire integrity standard of a boundary between two spaces within a main vertical zone or horizontal zone which is not protected by an automatic sprinkler system complying with the provisions of Regulation II-2/A/8 or between such zones neither of which is so protected, the higher of the two values given in the tables shall apply.
- .4 In determining the applicable fire integrity standard of a boundary between two spaces within a main vertical zone or horizontal zone which is protected by an automatic sprinkler system complying with the provisions of Regulation II-2/A/8 or between such zones both of which are so protected, the lesser of the two values given in the tables shall apply. Where a sprinklered zone and a non-sprinklered zone meet within accommodation and service spaces, the higher of the two values given in the tables shall apply to the division between the zones.
- .3 Continuous ‘B’ class ceilings or linings, in association with the relevant decks or bulkheads, may be accepted as contributing, wholly or in part, to the required insulation and integrity of a division.
- .4 External boundaries which are required in Regulation II-2/B/1, paragraph.1 to be of steel or other equivalent material may be pierced for the fitting of windows and sidescuttles provided that there is no requirement for such boundaries to have ‘A’ class integrity elsewhere in this part. Similarly, in such boundaries which are not required to have ‘A’ class integrity, doors may be of materials to the satisfaction of the Administration of the flag State.
Table 5.1
Fire integrity of bulkheads separating adjacent spaces
| Spaces | Spaces | (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | (10) | (11) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Control stations | (1) | A-0 (c) | A-0 | A-60 | A-0 | A-15 | A-60 | A-15 | A-60 | A-60 | (*) | A-60 |
| Corridors | (2) | C (e) | B-0(e) | A-0 (a) | B-0(e) | A-60 | A-0 | A-0 | A-15 | (*) | A-15 | |
| Corridors | (2) | B-0 (e) | A-0 (d) | |||||||||
| Accommodation spaces | (3) | C (e) | A-0 (a) | B-0 (e) | A-60 | A-0 | A-0 | A-15 | (*) | A-30 | ||
| Accommodation spaces | (3) | B-0 (e) | A-0 (d) | A-0 (d) | ||||||||
| Stairways | (4) | A-0 (a) | A-0 (a) | A-60 | A-0 | A-0 | A-15 | (*) | A-15 | |||
| Stairways | (4) | B-0 (e) | B-0 (e) | A-0 (d) | ||||||||
| Service spaces (low risk) | (5) | C (e) | A-60 | A-0 | A-0 | A-0 | (*) | A-0 | ||||
| Machinery spaces of category A | (6) | (*) | A-0 | A-0 | A-60 | (*) | A-60 | |||||
| Other machinery spaces | (7) | A-0 (b) | A-0 | A-0 | (*) | A-0 | ||||||
| Cargo spaces | (8) | (*) | A-0 | (*) | A-0 | |||||||
| Service spaces (high risk) | (9) | A-0 (b) | (*) | A-30 | ||||||||
| Open decks | (10) | A-0 | ||||||||||
| Special category spaces | (11) | A-0 |
The following table shall apply to ALL CLASS B, C and D SHIPS CONSTRUCTED ON OR AFTER 1 JANUARY 2018:
Table 5.1(a)
Fire integrity of bulkheads separating adjacent spaces
| Spaces | Spaces | (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | (10) | (11) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Control stations | (1) | A-0 (c) | A-0 | A-60 | A-0 | A-15 | A-60 | A-15 | A-60 | A-60 | (*) | A-60 |
| Corridors | (2) | C (e) | B-0(e) | A-0 (a) | B-0(e) | A-60 | A-0 | A-0 | A-15 | (*) | A-30 | |
| Corridors | (2) | B-0 (e) | A-0 (d) | |||||||||
| Accommodation spaces | (3) | C (e) | A-0 (a) | B-0 (e) | A-60 | A-0 | A-0 | A-15 | (*) | A-30 | ||
| Accommodation spaces | (3) | B-0 (e) | A-0 (d) | A-0 (d) | ||||||||
| Stairways | (4) | A-0 (a) | A-0 (a) | A-60 | A-0 | A-0 | A-15 | (*) | A-30 | |||
| Stairways | (4) | B-0 (e) | B-0 (e) | A-0 (d) | ||||||||
| Service spaces (low risk) | (5) | C (e) | A-60 | A-0 | A-0 | A-0 | (*) | A-0 | ||||
| Machinery spaces of category A | (6) | (*) | A-0 | A-0 | A-60 | (*) | A-60 | |||||
| Other machinery spaces | (7) | A-0 (b) | A-0 | A-0 | (*) | A-0 | ||||||
| Cargo spaces | (8) | (*) | A-0 | (*) | A-0 | |||||||
| Service spaces (high risk) | (9) | A-0 (b) | (*) | A-30 | ||||||||
| Open decks | (10) | A-0 | ||||||||||
| Special category spaces | (11) | A-30 |
Table 5.2
Fire integrity of decks separating adjacent spaces
| Space below↓ Space above→ | Space below↓ Space above→ | (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | (10) | (11) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Control stations | (1) | A-0 | A-0 | A-0 | A-0 | A-0 | A-60 | A-0 | A-0 | A-0 | (*) | A-30 |
| Corridors | (2) | A-0 | (*) | (*) | A-0 | (*) | A-60 | A-0 | A-0 | A-0 | (*) | A-0 |
| Accommodation spaces | (3) | A-60 | A-0 | (*) | A-0 | (*) | A-60 | A-0 | A-0 | A-0 | (*) | A-30 |
| Accommodation spaces | (3) | A-0 (d) | ||||||||||
| Stairways | (4) | A-0 | A-0 | A-0 | (*) | A-0 | A-60 | A-0 | A-0 | A-0 | (*) | A-0 |
| Service spaces (low risk) | (5) | A-15 | A-0 | A-0 | A-0 | (*) | A-60 | A-0 | A-0 | A-0 | (*) | A-0 |
| Machinery spaces of category A | (6) | A-60 | A-60 | A-60 | A-60 | A-60 | (*) | A-60 (f) | A-30 | A-60 | (*) | A-60 |
| Other machinery spaces | (7) | A-15 | A-0 | A-0 | A-0 | A-0 | A-0 | (*) | A-0 | A-0 | (*) | A-0 |
| Cargo spaces | (8) | A-60 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | (*) | A-0 | (*) | A-0 |
| Service spaces (high risk) | (9) | A-60 | A-30 | A-30 | A-30 | A-0 | A-60 | A-0 | A-0 | A-0 | (*) | A-30 |
| Service spaces (high risk) | (9) | A-0 (d) | A-0 (d) | A-0 (d) | ||||||||
| Open decks | (10) | (*) | (*) | (*) | (*) | (*) | (*) | (*) | (*) | (*) | — | A-0 |
| Special category spaces | (11) | A-60 | A-15 | A-30 | A-15 | A-0 | A-30 | A-0 | A-0 | A-30 | A-0 | A-0 |
| Special category spaces | (11) | A-0 (d) |
The following table shall apply to ALL CLASS B, C and D SHIPS CONSTRUCTED ON OR AFTER 1 JANUARY 2018:
Table 5.2(a)
Fire integrity of decks separating adjacent spaces
| Space below↓ Space above→ | Space below↓ Space above→ | (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | (10) | (11) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Control stations | (1) | A-0 | A-0 | A-0 | A-0 | A-0 | A-60 | A-0 | A-0 | A-0 | (*) | A-30 |
| Corridors | (2) | A-0 | (*) | (*) | A-0 | (*) | A-60 | A-0 | A-0 | A-0 | (*) | A-0 |
| Accommodation spaces | (3) | A-60 | A-0 | (*) | A-0 | (*) | A-60 | A-0 | A-0 | A-0 | (*) | A-30 |
| Accommodation spaces | (3) | A-0 (d) | ||||||||||
| Stairways | (4) | A-0 | A-0 | A-0 | (*) | A-0 | A-60 | A-0 | A-0 | A-0 | (*) | A-0 |
| Service spaces (low risk) | (5) | A-15 | A-0 | A-0 | A-0 | (*) | A-60 | A-0 | A-0 | A-0 | (*) | A-0 |
| Machinery spaces of category A | (6) | A-60 | A-60 | A-60 | A-60 | A-60 | (*) | A-60 (f) | A-30 | A-60 | (*) | A-60 |
| Other machinery spaces | (7) | A-15 | A-0 | A-0 | A-0 | A-0 | A-0 | (*) | A-0 | A-0 | (*) | A-0 |
| Cargo spaces | (8) | A-60 | A-0 | A-0 | A-0 | A-0 | A-0 | A-0 | (*) | A-0 | (*) | A-0 |
| Service spaces (high risk) | (9) | A-60 | A-30 | A-30 | A-30 | A-0 | A-60 | A-0 | A-0 | A-0 | (*) | A-30 |
| Service spaces (high risk) | (9) | A-0 (d) | A-0 (d) | A-0 (d) | ||||||||
| Open decks | (10) | (*) | (*) | (*) | (*) | (*) | (*) | (*) | (*) | (*) | — | A-0 |
| Special category spaces | (11) | A-60 | A-30 | A-30 | A-30 | A-0 | A-60 | A-0 | A-0 | A-30 | A-0 | A-30 |
| Special category spaces | (11) | A-0 (d) |
Notes to be applied to tables 5.1, 5.1(a), 5.2 and 5.2(a), as appropriate:
- (a) For clarification as to which applies, see Regulation II-2/B/3 and Regulation II-2/B/8.
- (b) Where spaces are of the same numerical category and superscript ‘b’ appears, a bulkhead or deck of the rating shown in the tables is only required when the adjacent spaces are for a different purpose, e.g. in category (9). A galley next to a galley does not require a bulkhead but a galley next to a paint room requires an ‘A-0’ bulkhead.
- (c) Bulkheads separating the wheelhouse and chartroom from each other may be ‘B-0’ rating.
- (d) See paragraph.2.3 and.2.4 of this Regulation II-2/B/5.
- (e) For the application of Regulation II-2/B/2, subparagraph.1.2, ‘B-0’ and ‘C’, where appearing in table 5.1 and 5.1(a), shall be read as ‘A-0’.
- (f) Fire insulation need not be fitted if the machinery space in category (7) has little or no fire risk.
- (*) Where an asterisk appears in the tables, the division is required to be of steel or other equivalent material but is not required to be of ‘A’ class standard. In ships, which are constructed on or after 1 January 2003, however, where a deck, except in a category (10) space, is penetrated for the passage of electric cables, pipes and ventilation ducts, such penetration shall be made tight to prevent the passage of flame and smoke. Divisions between control stations (emergency generators) and open decks may have air intake openings without means for closure, unless a fixed gas fire-fighting system is fitted. For the application of subparagraph.1.2. of Regulation II-2/B/2, an asterisk, where appearing in tables 5.2 and 5.2(a), except for categories (8) and (10), shall be read as ‘A-0’.
6. Regulation II-2/B/6: Means of escape (R 28)
NEW CLASS B, C AND D SHIPS AND EXISTING CLASS B SHIPS:
- .1 Stairways and ladders, corridors and doors shall be arranged to provide ready means of escape to the lifeboat and life-raft embarkation deck from all passenger and crew spaces and from spaces in which the crew is normally employed, other than machinery spaces. In particular, the following provisions shall be complied with:
- .1 Below the bulkhead deck, two means of escape, at least one of which shall be independent of watertight doors, shall be provided from each watertight compartment or similarly restricted space or group of spaces. Exceptionally one of the means of escape may be dispensed with, due regard being paid to the nature and location of spaces and to the number of persons who might be normally employed there.
In such a case the sole means of escape shall provide safe escape.
For ships which are constructed on or after 1 January 2003, the abovementioned dispensation may only be given for crew spaces that are entered only occasionally, in which case the required escape route shall be independent of watertight doors.
- .2 Above the bulkhead deck there shall be at least two means of escape from each main vertical zone or similarly restricted space or group of spaces, at least one of which shall give access to a stairway forming a vertical escape.
- .3 If a radiotelegraph station has no direct access to the open deck, two means of escape from or access to such station shall be provided, one of which may be a porthole or window of sufficient size or another means.
- .4 In existing class B ships, a corridor, or part of a corridor from which there is only one route of escape shall not exceed:
- .1 5 metres in length for ships constructed on or after 1 October 1994,
- .2 13 metres in length for ships constructed before 1 October 1994, carrying more than 36 passengers, and
- .3 7 metres in length for ships constructed before 1 October 1994, carrying not more than 36 passengers.
In new class A, B, C and D ships, a corridor, lobby or part of a corridor from which there is only one route of escape shall be prohibited.
Dead-end corridors used in service areas which are necessary for the practical utility of the ship, such as fuel oil stations and athwartship supply corridors, shall be permitted, provided such dead-end corridors are separated from crew accommodation areas and are inaccessible from passenger accommodation areas. A part of a corridor that has a depth not exceeding its width is considered a recess or local extension and is permitted.
NEW CLASS B, C AND D SHIPS CONSTRUCTED BEFORE 1 JANUARY 2003:
- .5 At least one of the means of escape required by paragraphs.1.1 and.1.2 shall consist of a readily accessible enclosed stairway, which shall provide continuous fire shelter from the level of its origin to the appropriate lifeboat and life-raft embarkation decks, or to the uppermost deck if the embarkation deck does not extend to the main vertical zone being considered.
In the latter case, direct access to the embarkation deck by way of external open stairways and passageways shall be provided and shall have emergency lighting in accordance with Regulation III/5, paragraph.3 and slip-free surfaces underfoot. Boundaries facing external open stairways and passageways forming part of an escape route shall be so protected that a fire in any enclosed space behind such boundaries would not impede escape to the embarkation stations.
The widths, number and continuity of escapes shall be as follows:
- .1 Stairways shall not be less than 900 mm in clear width, if reasonable and practicable to the satisfaction of the Member State, but shall in no case be less than 600 mm. Stairways shall be fitted with handrails on each side. The minimum clear width of stairways shall be increased by 10 mm for every one person provided for in excess of 90 persons. The maximum clear width between handrails where stairways are wider than 900 mm shall be 1 800 mm. The total number of persons to be evacuated by such stairways shall be assumed to be two thirds of the crew and the total number of passengers in the areas served by such stairways. The width of the stairways shall at least conform to the standard as given in IMO Resolution A.757(18).
- .2 All stairways sized for more than 90 persons shall be aligned before and after.
- .3 Doorways and corridors and intermediate landings included in means of escape shall be sized in the same manner as stairways.
- .4 Stairways shall not exceed 3,5 metres in vertical rise without the provision of a landing and shall not have an angle of inclination greater than 45°.
- .5 Landings at each deck level shall not be less than 2 m2 in area and shall increase by 1 m2 for every 10 persons provided for in excess of 20 persons but need not exceed 16 m2, except for those landings servicing public spaces having direct access onto the stairway enclosure.
CLASS B, C AND D SHIPS CONSTRUCTED ON OR AFTER 1 JANUARY 2003:
- .5a At least one of the means of escape required in the paragraphs.1.1 and.1.2 shall consist of a readily accessible enclosed stairway, which shall provide continuous fire shelter from the level of its origin to the appropriate lifeboat and life-raft embarkation decks, or to the uppermost weather deck if the embarkation deck does not extend to the main vertical zone being considered.
In the latter case, direct access to the embarkation deck by way of external open stairways and passageways shall be provided and shall have emergency lighting in accordance with Regulation III/5.3 and slip-free surfaces underfoot. Boundaries facing external open stairways and passageways forming part of an escape route and boundaries in such a position that their failure during a fire would impede escape to the embarkation deck shall have fire integrity, including insulation values, in accordance with tables 4.1 to 5.2, as appropriate.
The widths, number and continuity of escapes shall be in accordance with the requirements of the Fire Safety Systems Code.
NEW CLASS B, C AND D CONSTRUCTED BEFORE 1 JANUARY 2003 AND EXISTING CLASS B SHIPS:
- .6 Satisfactory protection of access from the stairway enclosures to the lifeboat and life-raft embarkation areas shall be provided.
CLASS B, C AND D SHIPS CONSTRCTED ON OR AFTER 1 JANUARY 2003:
- .6a Protection of access from the stairway enclosures to the lifeboat and life-raft embarkation areas shall be provided either directly or through protected internal routes which have fire integrity and insulation values for stairway enclosures as determined by tables 4.1 to 5.2, as appropriate.
NEW CLASS B, C AND D SHIPS:
- .7 In addition to the emergency lighting required by Regulations II-1/D/3 and III/5.3, the means of escape including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 0,3 metres above the deck at all points of the escape route, including angles and intersections. The marking must enable passengers to identify all the routes of escape and readily identify the escape exits. If electric illumination is used, it shall be supplied by the emergency source of power and it shall be so arranged that the failure of any single light or cut in a lighting strip will not result in the marking being ineffective. Additionally, all escape route signs and fire equipment location markings shall be of photoluminescent material or marked by lighting. The Administration of the flag State shall ensure that such lighting or photoluminescent equipment have been evaluated, tested and applied in accordance with the guidelines as given in IMO Resolution A.752(18).
However, for new class B, C and D ships constructed on or after 1 January 2003 the Administration of the Flag State shall ensure that such lighting or photoluminescent equipment has been evaluated, tested and applied in accordance with the Fire Safety Systems Code.
CLASS B, C AND D SHIPS CONSTRUCTED ON OR AFTER 1 JANUARY 2003:
- .8 In ships carrying more than 36 passengers the requirements of paragraph.1.7 of this Regulation II-2/B/6 shall also apply to the crew accommodations.
- .9 Normally locked doors that form part of an escape route.
- .1 Cabin and stateroom doors shall not require keys to unlock them from inside the room.
Neither shall there be any doors along any designated escape route which require keys to unlock them when moving in the direction of escape.
- .2 Escape doors from public spaces that are normally latched shall be fitted with a means of quick release. Such means shall consist of a door-latching mechanism incorporating a device that releases the latch upon the application of a force in the direction of escape flow. Quick release mechanisms shall be designed and installed to the satisfaction of the Administration of the flag State and, in particular:
- .2.1 consist of bars or panels, the actuating portion of which extends across at least one half of the width of the door leaf, at least 760 mm and not more than 1 120 mm above the deck;
- .2.2 cause the door latch to release when a force not exceeding 67 N is applied; and
- .2.3 not be equipped with any locking device, set screw or other arrangement that prevents the release of the latch when pressure is applied to the releasing device.
NEW CLASS B, C AND D AND EXISTING CLASS B SHIPS:
- .2 - .1 In special category spaces the number and disposition of the means of escape both below and above the bulkhead deck shall be to the satisfaction of the Administration of the flag State and, in general, the safety of access to the embarkation deck shall be at least equivalent to that provided under paragraphs.1.1,.1.2,.1.5 and.1.6.
In new class B, C and D ships constructed on or after 1 January 2003, such spaces shall be provided with designated walkways to the means of escape with a breadth of at least 600 mm, and where practicable and reasonable those designated longitudinal walkways shall raise at least 150 mm above the deck surface. The parking arrangements for the vehicles shall maintain the walkways clear at all times.
- .2 One of the escape routes from the machinery spaces where the crew is normally employed shall avoid direct access to any special category space.
- .3 Hoistable drive-up/down ramps to platform decks must not be capable of blocking the approved escape routes when in lowered position.
- .3.1 Two means of escape shall be provided from each machinery space. In particular, the following provisions shall be complied with:
- .1 Where the space is below the bulkhead deck the two means of escape shall consist of either:
- .1 two sets of steel ladders as widely separated as possible, leading to doors in the upper part of the space similarly separated, and from which there is access to the appropriate lifeboat and life-raft embarkation decks. In new ships, one of these ladders shall provide continuous fire shelter from the lower part of the space to a safe position outside the space. In new class B, C and D ships constructed on or after 1 January 2003 that ladder shall be located within a protected enclosure that satisfies Regulation II-2/B/4, category (2) or II-2/B/5, category (4), as appropriate, from the lower part of the space it serves to a safe position outside the space. Self-closing fire doors of the same fire integrity standards shall be fitted in the enclosure. The ladder shall be fixed in such a way that heat is not transferred into the enclosure through non-insulated fixing points. The protected enclosure shall have minimum internal dimensions of at least 800 mm × 800 mm, and shall have emergency lighting provisions; or
- .2 one steel ladder leading to a door in the upper part of the space from which access is provided to the embarkation deck and additionally, in the lower part of the space and in a position well separated from the ladder referred to, a steel door capable of being operated from each side and which provides access to a safe escape route from the lower part of the space to the embarkation deck.
- .2 Where the space is above the bulkhead deck, the two means of escape shall be as widely separated as possible and the doors leading from such means of escape shall be a position from which access is provided to the appropriate lifeboat and life-raft embarkation decks. Where such means of escape require the use of ladders, these shall be of steel.
NEW CLASS A, B, C AND D SHIPS:
- .3 From spaces for monitoring of operation of machinery, and from work spaces, there shall be at least two means of escape, of which one shall be independent of the machinery space and give access to the embarkation deck.
- .4 The underside of stairs in machinery spaces shall be shielded.
NEW CLASS B, C AND D AND EXISTING CLASS B SHIPS:
- .3.2 The Administration of the flag State may dispense with one means of escape from any such space so long as either a door or a steel ladder provides a safe escape route to the embarkation deck, due regard being paid to the nature and location of the space and whether persons are normally employed in that space. In new class B, C and D ships constructed on or after 1 January 2003, a second means of escape shall be provided in the steering gear space when the emergency steering position is located in that space unless there is a direct access to the open deck.
- .3.3 Two means of escape shall be provided from a machinery control room located within a machinery space, at least one of which will provide continuous fire shelter to a safe position outside the machinery space.
CLASS B, C and D SHIPS CONSTRUCTED ON OR AFTER 1 JANUARY 2018
- .3.4 Two means of escape shall be provided from the main workshop within a machinery space. At least one of those escape routes shall provide a continuous fire shelter to a safe position outside the machinery space.
NEW CLASS B, C AND D AND EXISTING CLASS B SHIPS:
- .4 In no case shall lifts be considered as forming one of the required means of escape.
- .5 NEW CLASS B, C AND D AND EXISTING CLASS B SHIPS OF 40 METRES IN LENGTH AND ABOVE:
- .1 Emergency escape breathing devices shall be carried, complying with the Fire Safety Systems Code.
- .2 At least two emergency escape breathing devices shall be carried in each main vertical zone.
- .3 In ships carrying more than 36 passengers, two emergency escape breathing devices, in addition to those required in subparagraph.5.2 shall be carried in each main vertical zone.
- .4 However, subparagraphs.5.2 and.5.3 do not apply to stairway enclosures which constitute individual main vertical zones and for the main vertical zones in the fore or aft end of a ship, which do not contain spaces of categories (6), (7), (8) or (12) defined in Regulation II-2/B/4.
Reading this document does not replace reading the official text published in the Official Journal of the European Union. We assume no responsibility for any inaccuracies arising from the conversion of the original to this format.
This text is published under EUR-Lex's own terms of reuse, not a Legalize or public-domain licence.
EUR-Lex
Creative Commons Attribution 4.0 International (CC BY 4.0)
© European Union, https://eur-lex.europa.eu — Source: EUR-Lex (Publications Office of the European Union). Reused under the Creative Commons Attribution 4.0 International (CC BY 4.0) licence. Only EU legislation published in the printed Official Journal of the European Union is deemed authentic; consolidated texts are reproduced here for documentation purposes and have been reformatted to Markdown.