  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — Do not use near domestic animals or livestock.

Application – mopping and wiping:

  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open). Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent providing a protection factor of 4 is mandatory if the product is used in rooms < 1 000 m3. At least a powered air purifying respirator with helmet, hood or mask (TH1 or TM1), or a half mask or full mask with gas filter is required.
  • — Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m3) or relevant lower national reference value.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

Application – pouring:

  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — Use only in rooms with a volume ≥ 1 000 m3.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

1 % in-use dilution

Application – spraying – trigger spray:

  • — Spraying is only allowed in the downward or horizontal direction.
  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

Application – spraying – Knapsack or backpack sprayer:

  • — Spraying is only allowed in the downward or horizontal direction.
  • — The flow rate of the backpack sprayer must not exceed 0,3 l/min.
  • — Use only in rooms with a volume ≥ 1 000 m3.
  • — No access of third parties during application or treatment.
  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — Do not use near domestic animals or livestock.

Application – mopping and wiping:

  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

Application – pouring:

  • — Ensure adequate ventilation (at least 3 air changes per hour) during application.
  • — Use only in rooms with a volume ≥ 1 000 m3.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

When means of protection are indicated, this is without prejudice to the application of Council Directive 98/24/EC and other Union legislation in the area of health and safety at work.

See section 6 for the full reference to this act and the European standards.

4.4.3.   Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment

See General directions for use of the meta SPC.

4.4.4.   Where specific to the use, the instructions for safe disposal of the product and its packaging

Keep only in original container. Empty container completely. Keep labels on container. Dispose the container in accordance with the regulations issued by the appropriate authorities.

4.4.5.   Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage

See storage condition in section General direction for use of the meta SPC.

4.5.   Use description

Table 5
Disinfection of surfaces in accomodations and adjacent rooms for animals
Product type PT03: Veterinary hygiene
Where relevant, an exact description of the authorised use —
Target organism(s) (including development stage) Scientific name: no data Common name: Bacteria Development stage: no data Scientific name: no data Common name: Yeasts Development stage: no data Scientific name: no data Common name: Mycobacteria Development stage: no data
Field(s) of use Indoor use Disinfection of hard non-porous surfaces in accommodations and adjacent rooms for animals.
Application method(s) Method: Manual application by pouring or spraying (trigger spray or knapsack sprayer). Manual application by pouring or spraying followed by wiping or mopping. Detailed description: —
Application rate(s) and frequency Application rate: Trigger spray: 0,030 - 0,060 litre/m2 Watering can: 0,19 - 1,92 litre/m2 Knapsack or backpack spray: 0,181 litre/m2 Pouring or spraying followed by wiping or mopping: 0,030 - 0,060 litre/m2 Dilution: 2 % - 6 % Number and timing of application: Apply in addition to daily cleaning; 10 applications per day shall not be exceeded.
Category(ies) of users Professional
Pack sizes and packaging material 1 L HDPE bottle with screw cap (outer cap HDPE, inner cap PPC, with LDPE or PE foam liner as pressure release valve) 5, 10 and 20 L HDPE cans with screw cap (HDPE) with inlay (PE foam) and pressure release membrane (PTFE) 220 L HDPE drums with HDPE screw cap (with pressure release membrane) 1 000 L HDPE IBC with HDPE screw cap (with pressure release vent) and outlet opening with butterfly valve.
4.5.1.   Use-specific instructions

Thoroughly clean the surfaces to be disinfected.

Remove a cleaning agent, if used, with clean water.

Remove excess of water.

Prepare a dilution of the product manually in a bucket, watering can, trigger spray or knapsack sprayer and apply this use dilution:

  • — for bacteria and yeasts: dilute the product to 2 % (v/v; 20 ml product, add water to 1 litre) and the surface should remain wet at least 5 minutes.
  • — for bacteria, mycobacteria and yeasts: dilute the product to 6 % (v/v; 60 ml product, add water to 1 litre) and the surface should remain wet at least 5 minutes.

or

Prepare a dilution of the product in a bucket, watering can, trigger spray or knapsack sprayer by means of an automated dosage system according the use instructions of the apparatus.

Subsequently pour the diluted product on the floor under feed troughs or apply the product with a trigger spray or knapsack sprayer. Make sure that the surface remains wet for at least 5 minutes.

The dilution is intended for immediate use.

Where gas filters (RPE) are required, training must be ensured for the users.

4.5.2.   Use-specific risk mitigation measures

Mixing and loading – Manual (undiluted):

  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — The use of eye protection (chemical goggles) consistent with EN 166 or equivalent during handling of the product is mandatory.
  • — Ensure adequate ventilation (at least 3 air changes per hour) during mixing and loading.
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent providing a protection factor of 10 is mandatory. At least a powered air purifying respirator with helmet, hood or mask (TH1 or TM1), or a half mask or full mask with gas filter is required.
  • — Wear a protective coverall (at least type 4, consistent with EN 14605 or equivalent) which is impermeable for the biocidal product (coverall material to be specified by the authorisation holder within the product information).

6 % in-use dilution

Application – spraying – trigger spray:

  • — Spraying is only allowed in the downward or horizontal direction.
  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent providing a protection factor of 10 is mandatory if the product is used in rooms < 100 m3 with a ventilation of < 3 air changes per hour. At least a powered air purifying respirator with helmet, hood or mask (TH1 or TM1), or a half mask or full mask with gas filter is required.
  • — Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m3) or relevant lower national reference value.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.
  • — Animals must be kept away from treated areas until surfaces are dry.

Application – spraying – Knapsack or backpack sprayer:

  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — The flow rate of the backpack sprayer must not exceed 0,3 l/min.
  • — Spraying is only allowed in the downward or horizontal direction.
  • — Use only in rooms with a volume ≥ 1 000 m3.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.
  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — Animals must be kept away from treated areas until surfaces are dry.

Application – mopping and wiping:

  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent providing a protection factor of 10 is mandatory if the product is used in rooms < 1 000 m3. At least a powered air purifying respirator with helmet, hood or mask (TH1 or TM1), or a half mask or full mask with gas filter is required.
  • — Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m3) or relevant lower national reference value.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.
  • — Animals must be kept away from treated areas until surfaces are dry.

Application – pouring:

  • — Pouring application should take place under feed troughs.
  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — Ensure adequate ventilation (at least 3 air changes per hour) during application.
  • — Use only in rooms with a volume ≥ 1 000 m3.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.
  • — Animals must be kept away from treated areas until surfaces are dry.

2 % in-use dilution

Application – spraying – trigger spray:

  • — Spraying is only allowed in the downward or horizontal direction.
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent providing a protection factor of 4 is mandatory if the product is used in rooms < 100 m3 with a ventilation of < 3 air changes per hour. At least a powered air purifying respirator with helmet, hood or mask (TH1 or TM1), or a half mask or full mask with gas filter is required.
  • — Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m3) or relevant lower national reference value.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.
  • — Animals must be kept away from treated areas until surfaces are dry.

Application – spraying – Knapsack/backpack sprayer:

  • — Spraying is only allowed in the downward or horizontal direction.
  • — The flow rate of the backpack sprayer must not exceed 0,3 l/min.
  • — Use only in rooms with a volume ≥ 1 000 m3.
  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.
  • — Animals must be kept away from treated areas until surfaces are dry.

Application – mopping and wiping:

  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent providing a protection factor of 4 is mandatory if the product is used in rooms < 1 000 m3. At least a powered air purifying respirator with helmet, hood or mask (TH1 or TM1), or a half mask or full mask with gas filter is required.
  • — Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m3) or relevant lower national reference value.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.
  • — Animals must be kept away from treated areas until surfaces are dry.

Application – pouring:

  • — Pouring application should take place under feed troughs.
  • — Ensure adequate ventilation (at least 3 air changes per hour) during application.
  • — Use only in rooms with a volume ≥ 1 000 m3.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.
  • — Animals must be kept away from treated areas until surfaces are dry.

When means of protection are indicated, this is without prejudice to the application of Council Directive 98/24/EC and other Union legislation in the area of health and safety at work.

See section 6 for the full reference to this act and the European standards.

4.5.3.   Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment

See General directions for use of the meta SPC.

4.5.4.   Where specific to the use, the instructions for safe disposal of the product and its packaging

Keep only in original container. Empty container completely. Keep labels on container. Dispose the container in accordance with the regulations issued by the appropriate authorities.

4.5.5.   Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage

See storage conditions in section General directions for use of the meta SPC.

4.6.   Use description

Table 6
Disinfection of surfaces in the food industry
Product type PT04: Food and feed area
Where relevant, an exact description of the authorised use —
Target organism(s) (including development stage) Scientific name: no data Common name: Bacteria Development stage: no data Scientific name: no data Common name: Yeasts Development stage: no data Scientific name: no data Common name: Fungi Development stage: no data Scientific name: no data Common name: Mycobacteria Development stage: no data Scientific name: no data Common name: Viruses Development stage: no data
Field(s) of use Indoor use Disinfection of hard non-porous surfaces in the food industry.
Application method(s) Method: Manual application by pouring or spraying (trigger spray or knapsack sprayer). Manual application by pouring or spraying followed by wiping or mopping. Detailed description: —
Application rate(s) and frequency Application rate: Trigger spray: 0,030 - 0,060 litre/m2 Watering can: 0,19 - 1,92 litre/m2 Knapsack or backpack spray: 0,181 litre/m2 Pouring or spraying followed by wiping or mopping: 0,030 - 0,060 litre/m2 Dilution: 1 % - 7 % Number and timing of application: Apply in addition to daily cleaning; 3 applications per day shall not be exceeded. Temperature: room temperature.
Category(ies) of users Professional
Pack sizes and packaging material 1 L HDPE bottle with screw cap (outer cap HDPE, inner cap PPC, with LDPE or PE foam liner as pressure release valve) 5, 10 and 20 L HDPE cans with screw cap (HDPE) with inlay (PE foam) and pressure release membrane (PTFE) 220 L HDPE drums with HDPE screw cap (with pressure release membrane) 1 000 L HDPE IBC with HDPE screw cap (with pressure release vent) and outlet opening with butterfly valve.
4.6.1.   Use-specific instructions

Thoroughly clean the surfaces to be disinfected.

Remove a cleaning agent, if used, with clean water.

Remove excess of water.

Prepare a dilution of the product manually in a bucket, watering can, trigger spray or knapsack sprayer:

  • — for bacteria, yeasts, and viruses: dilute the product to 1 % (v/v; 10 ml product, add water to 1 litre).
  • — for bacteria, yeasts, fungi, and viruses: dilute the product to 4 % (v/v; 40 ml product, add water to 1 litre).
  • — for bacteria, mycobacteria, yeasts, fungi, and viruses: dilute the product to 7 % (v/v; 70 ml product, add water to 1 litre).

or

Prepare a dilution of the product in a bucket, watering can, trigger spray or knapsack sprayer by means of an automated dosage system according to the use instructions of the apparatus.

Subsequently pour the diluted product on the floor or apply the product with a trigger spray or knapsack sprayer. Make sure that the surface remains wet for at least 5 minutes.

The dilution is intended for immediate use.

Where gas filters (RPE) are required, training must be ensured for the users.

4.6.2.   Use-specific risk mitigation measures

Mixing and loading – Manual (undiluted):

  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — The use of eye protection (chemical goggles) consistent with EN 166 or equivalent during handling of the product is mandatory.
  • — Ensure adequate ventilation (at least 3 air changes per hour) during mixing and loading.
  • — Use of respiratory protective equipment (RPE) providing a protection factor of 10 is mandatory. At least a powered air purifying respirator with helmet, hood, or mask (TH1 or TM1), or a half mask or full mask with gas filter is required. consistent with EN 12941 or equivalent
  • — Wear a protective coverall (at least type 4, consistent with EN 14605 or equivalent) which is impermeable for the biocidal product (coverall material to be specified by the authorisation holder within the product information).

7 % in-use dilution

Mixing and loading – Manual:

  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — The use of eye protection (chemical goggles) consistent with EN 166 or equivalent during handling of the product is mandatory.
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent is mandatory.

Application – spraying – trigger spray:

  • — Spraying is only allowed in the downward or horizontal direction.
  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — The use of eye protection (chemical goggles) consistent with EN 166 or equivalent during handling of the product is mandatory.
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent is mandatory. If the product is used in rooms =< 100 m3 with a ventilation of =< 3 air changes per hour a protection factor of 10 is mandatory At least a powered air purifying respirator with helmet, hood, or mask (TH1 or TM1), or a half mask or full mask with gas filter is required.
  • — Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m3) or relevant lower national reference value.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

Application – spraying – Knapsack or backpack sprayer:

  • — Spraying is only allowed in the downward or horizontal direction with a lance sprayer.
  • — The flow rate of the backpack sprayer must not exceed 0,3 l/min.
  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — The use of eye protection (chemical goggles) consistent with EN 166 or equivalent during handling of the product is mandatory.
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent is mandatory.
  • — Wear chemical resistant boots consistent with EN 13832 or equivalent during product handling phase.
  • — Wear a protective coverall (at least type 4, consistent with EN 14605 or equivalent) which is impermeable for the biocidal product (coverall material to be specified by the authorisation holder within the product information).
  • — Use only in rooms with a volume ≥ 1 000 m3
  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — Do not use near domestic animals or livestock.

Application – mopping and wiping:

  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — The use of eye protection (chemical goggles) consistent with EN 166 or equivalent during handling of the product is mandatory.
  • — Wear chemical resistant boots consistent with EN 13832 or equivalent during product handling phase.
  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent is mandatory. If the product is used in rooms < 1 000 m3 a protection factor of 10 is mandatory. At least a powered air purifying respirator with helmet, hood or mask (TH1 or TM1), or a half mask or full mask with gas filter is required.
  • — Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m3) or relevant lower national reference value.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

Application – pouring:

  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — The use of eye protection (chemical goggles) consistent with EN 166 or equivalent during handling of the product is mandatory.
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent is mandatory.
  • — Wear chemical resistant boots consistent with EN 13832 or equivalent during product handling phase.
  • — Ensure adequate ventilation (at least 3 air changes per hour) during application.
  • — Use only in rooms with a volume ≥ 1 000 m3
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

6 % in-use dilution

Application – spraying – trigger spray:

  • — Spraying is only allowed in the downward or horizontal direction.
  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent providing a protection factor of 10 is mandatory if the product is used in rooms < 100 m3 with a ventilation of < 3 air changes per hour. At least a powered air purifying respirator with helmet, hood, or mask (TH1 or TM1), or a half mask or full mask with gas filter is required.
  • — Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m3) or relevant lower national reference value.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

Application – spraying – Knapsack or backpack sprayer:

  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — The flow rate of the backpack sprayer must not exceed 0,3 l/min.
  • — Spraying is only allowed in the downward or horizontal direction.
  • — Use only in rooms with a volume ≥ 1 000 m3.
  • — No access of third parties during application or treatment.
  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).>
  • — Do not use near domestic animals or livestock.

Application – mopping and wiping:

  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent providing a protection factor of 10 is mandatory if the product is used in rooms < 1 000 m3. At least a powered air purifying respirator with helmet, hood or mask (TH1 or TM1), or a half mask or full mask with gas filter is required.
  • — Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m3) or relevant lower national reference value.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

Application – pouring:

  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — Ensure adequate ventilation (at least 3 air changes per hour) during application.
  • — Use only in rooms with a volume ≥ 1 000 m3.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

4 % in-use dilution

Application – spraying – trigger spray:

  • — Spraying is only allowed in the downward or horizontal direction.
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent providing a protection factor of 4 is mandatory if the product is used in rooms < 100 m3 with a ventilation of < 3 air changes per hour. At least a powered air purifying respirator with helmet, hood, or mask (TH1 or TM1), or a half mask or full mask with gas filter is required.
  • — Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m3) or relevant lower national reference value.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

Application – spraying – Knapsack or backpack sprayer:

  • — Spraying is only allowed in the downward or horizontal direction.
  • — The flow rate of the backpack sprayer must not exceed 0,3 l/min.
  • — Use only in rooms with a volume ≥ 1 000 m3.
  • — No access of third parties during application or treatment.
  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — Do not use near domestic animals or livestock.

Application – mopping and wiping:

  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open). Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent providing a protection factor of 4 is mandatory if the product is used in rooms < 1 000 m3. At least a powered air purifying respirator with helmet, hood or mask (TH1 or TM1), or a half mask or full mask with gas filter is required.
  • — Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m3) or relevant lower national reference value.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

Application – pouring:

  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — Use only in rooms with a volume ≥ 1 000 m3.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

1 % in-use dilution

Application – spraying – trigger spray:

  • — Spraying is only allowed in the downward or horizontal direction.
  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

Application – spraying – Knapsack/backpack sprayer:

  • — Spraying is only allowed in the downward or horizontal direction.
  • — The flow rate of the backpack sprayer must not exceed 0,3 l/min.
  • — Use only in rooms with a volume ≥ 1 000 m3.
  • — No access of third parties during application or treatment.
  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — Do not use near domestic animals or livestock.

Application – mopping and wiping:

  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

Application – pouring:

  • — Ensure adequate ventilation (at least 3 air changes per hour) during application.
  • — Use only in rooms with a volume ≥ 1 000 m3.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

When means of protection are indicated, this is without prejudice to the application of Council Directive 98/24/EC and other Union legislation in the area of health and safety at work.

See section 6 for the full reference to this act and the European standards.

4.6.3.   Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment

See General directions for use of the meta SPC.

4.6.4.   Where specific to the use, the instructions for safe disposal of the product and its packaging

Keep only in original container. Empty container completely. Keep labels on container. Dispose the container in accordance with the regulations issued by the appropriate authorities.

4.6.5.   Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage

See storage conditions in section General directions for use of the meta SPC.

4.7.   Use description

Table 7
Disinfection of inner surfaces of installations coming into contact with water (potable water systems for humans and animals and proces water)
Product type PT04: Food and feed area
Where relevant, an exact description of the authorised use —
Target organism(s) (including development stage) Scientific name: no data Common name: Bacteria including Legionella spp Development stage: no data
Field(s) of use Indoor use Disinfection of inner surfaces of installations coming into contact with water that are temporarily not in use during disinfection (potable water systems for humans and animals and process water).
Application method(s) Method: other filling of water system with dilution of product. Detailed description: —
Application rate(s) and frequency Application rate: — Dilution: 0,88 % Number and timing of application: Apply when the microbiological contamination of the water in or supplied by the system exceeds defined values. These values may vary for the different areas where and for which applications the water is used and may be subject to local regulations. Microbiological contamination is assessed by culturing the micro-organisms in water samples and is expressed as the number of colony forming units (CFU’s) per volume of water. Temperature: room temperature.
Category(ies) of users Professional
Pack sizes and packaging material 1 L HDPE bottle with screw cap (outer cap HDPE, inner cap PPC, with LDPE or PE foam liner as pressure release valve) 5, 10 and 20 L HDPE cans with screw cap (HDPE) with inlay (PE foam) and pressure release membrane (PTFE) 220 L HDPE drums with HDPE screw cap (with pressure release membrane) 1 000 L HDPE IBC with HDPE screw cap (with pressure release vent) and outlet opening with butterfly valve.
4.7.1.   Use-specific instructions

Clean the inner surfaces of the system.

Remove a cleaning agent, if used, with clean water.

Remove excess of water.

Prepare a 0,88 % product dilution (v/v) of the product by means of an automated dosing system attached to the water system. Fill the system with the diluted product and let the use solution remain in the water system for at least 5 minutes. Subsequently remove the working solution and flush the system with clean water until the concentration of active substances is below the accepted limit values (to be measured by means of peroxide test strips).

4.7.2.   Use-specific risk mitigation measures

During treatment the water cannot be used for consumption.

4.7.3.   Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment

See General directions for use of the meta SPC.

4.7.4.   Where specific to the use, the instructions for safe disposal of the product and its packaging

Keep only in original container. Empty container completely. Keep labels on container. Dispose the container in accordance with the regulations issued by the appropriate authorities.

4.7.5.   Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage

See storage conditions in section General directions for the use of meta SPC.

5. GENERAL DIRECTIONS FOR USE OF THE META SPC 1

5.1.   Instructions for use

See use specific instructions for use.

5.2.   Risk mitigation measures

See risk mitigation measures for specific uses.

5.3.   Particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment

IF SWALLOWED: Immediately rinse mouth. Give something to drink, if exposed person is able to swallow. Do NOT induce vomiting. Call 112 or an ambulance for medical assistance.

IF ON SKIN: Immediately wash skin with plenty of water. Thereafter take off all contaminated clothing and wash it before reuse. Continue to wash the skin with water for 15 minutes. Call a POISON CENTRE or a doctor.

IF IN EYES: Immediately rinse with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing for at least 15 minutes. Call 112 or an ambulance for medical assistance.

IF INHALED: Move to fresh air and keep at rest in a position comfortable for breathing. If symptoms: Call 112 or an ambulance for medical assistance. If no symptoms: Call a POISON CENTRE or a doctor.

Avoid release of the product into the environment.

5.4.   Instructions for safe disposal of the product and its packaging

Keep only in original container. Empty container completely. Keep labels on container. Dispose the container in accordance with the regulations issued by the appropriate authorities.

5.5.   Conditions of storage and shelf-life of the product under normal conditions of storage

Shelf life: 3 months.

Store in the original container at room temperature. Store away from light. Protect from frost.

6. OTHER INFORMATION

Professionals (including industrial, professionals) mean trained professional if this is required by national legislation.

The full titles of the EN standards referenced in the Risk mitigation measures are:

EN 13832 – Footwear protecting against chemicals

EN ISO 374 – Protective gloves against dangerous chemicals and micro-organisms

EN 12941 – Respiratory protective devices – Powered filtering devices incorporating a loose fitting respiratory interface

EN 166 – Eye protection against chemicals

EN 14605 – Protective clothing against liquid chemicals – Performance requirements for clothing with liquid-tight (Type 3) or spray-tight (Type 4) connections, including items providing protection to parts of the body only (Types PB [3] and PB [4]).

Council Directive 98/24/EC of 7 April 1998 on the protection of the health and safety of workers from the risks related to chemical agents at work (fourteenth individual Directive within the meaning of Article 16(1) of Directive 89/391/EEC) (OJ L 131, 5.5.1998, p. 11).

7. THIRD INFORMATION LEVEL: INDIVIDUAL PRODUCTS IN THE META SPC 1

7.1.   Trade name(s), authorisation number and specific composition of each individual product

Trade name(s) Trade name(s) Trade name(s) Tevan Panox® Tevan Panox® Market area: EU Market area: EU Market area: EU
Trade name(s) Trade name(s) Trade name(s) Aquanorm Aquanorm Market area: EU Market area: EU Market area: EU
Authorisation number Authorisation number Authorisation number EU-0032875-0001 1-1 EU-0032875-0001 1-1 EU-0032875-0001 1-1
Common name IUPAC name Function Function CAS number CAS number EC number Content (%)
Peracetic acid active substance active substance 79-21-0 79-21-0 201-186-8 1,7 % (w/w)
Hydrogen peroxide dihydrogen dioxide non-active substance non-active substance 7722-84-1 7722-84-1 231-765-0 47,25 % (w/w)
Polyphosphoric acid Polyphosphoric acids non-active substance non-active substance 8017-16-1 8017-16-1 232-417-0 1,992 % (w/w)
Acetic acid ethanoic acid non-active substance non-active substance 64-19-7 64-19-7 200-580-7 0,7286 % (w/w)

1. META SPC 2 ADMINISTRATIVE INFORMATION

1.1.   Meta SPC 2 identifier

Identifier Meta SPC: Tevan Panox 1816

1.2.   Suffix to the authorisation number

Number 1-2

1.3.   Product type(s)

Product type(s) PT02: Disinfectants and algaecides not intended for direct application to humans or animals PT03: Veterinary hygiene PT04: Food and feed area

2. META SPC 2 COMPOSITION

2.1.   Qualitative and quantitative information on the composition of the meta SPC 2

Common name IUPAC name Function CAS number EC number Content (%)
Peracetic acid active substance 79-21-0 201-186-8 0,5667 - 0,5667 % (w/w)
Hydrogen peroxide dihydrogen dioxide non-active substance 7722-84-1 231-765-0 15,75 - 15,75 % (w/w)
Polyphosphoric acid Polyphosphoric acids non-active substance 8017-16-1 232-417-0 0,664 - 0,664 % (w/w)
Acetic acid ethanoic acid non-active substance 64-19-7 200-580-7 0,2429 - 0,2429 % (w/w)

2.2.   Type(s) of formulation of the meta SPC 2

Formulation type(s) SL Soluble concentrate

3. HAZARD AND PRECAUTIONARY STATEMENTS OF THE META SPC 2

Hazard statements H272: May intensify fire; oxidiser. H290: May be corrosive to metals. H314: Causes severe skin burns and eye damage. H411: Toxic to aquatic life with long lasting effects. EUH071: Corrosive to the respiratory tract.
Precautionary statements P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P220: Keep away from clothing or other combustible materials. P234: Keep only in original packaging. P273: Avoid release to the environment. P390: Absorb spillage to prevent material damage. P391: Collect spillage. P260: Do not breathe vapours. P280: Wear protective gloves. P280: Wear protective clothing. P280: Wear eye protection. P280: Wear face protection. P301+P330+P331: IF SWALLOWED: rinse mouth. Do NOT induce vomiting. P310: Immediately call a doctor. P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower]. P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P363: Wash contaminated clothing before reuse. P405: Store locked up. P501: Dispose of container to a disposal facility in accordance with local regulations.

4. AUTHORISED USE(S) OF THE META SPC

4.1.   Use description

Table 1
Disinfection of hard surfaces in hospitals and other health care institutions
Product type PT02: Disinfectants and algaecides not intended for direct application to humans or animals
Where relevant, an exact description of the authorised use —
Target organism(s) (including development stage) Scientific name: no data Common name: Bacteria Development stage: no data Scientific name: no data Common name: Yeasts Development stage: no data Scientific name: no data Common name: Fungi Development stage: no data Scientific name: no data Common name: Mycobacteria Development stage: no data Scientific name: no data Common name: Viruses Development stage: no data
Field(s) of use Indoor use Disinfection of hard non-porous surfaces in hospitals and other health care institutions.
Application method(s) Method: Manual application by pouring or spraying (trigger spray or knapsack sprayer). Manual application by pouring or spraying followed by wiping or mopping. Detailed description: —
Application rate(s) and frequency Application rate: Trigger spray: 0,030 - 0,060 litre/m2 Watering can: 0,19 - 1,92 litre/m2 Knapsack or backpack spray: 0,181 litre/m2 Pouring or spraying followed by wiping or mopping: 0,030 - 0,060 litre/m2 Dilution: 3 % - 21 % Number and timing of application: Apply in addition to daily cleaning; 10 applications per day shall not be exceeded. Temperature: room temperature.
Category(ies) of users Professional
Pack sizes and packaging material 1 L HDPE bottle with screw cap (outer cap HDPE, inner cap PPC, with LDPE or PE foam liner as pressure release valve) 5, 10 and 20 L HDPE cans with screw cap (HDPE) with inlay (PE foam) and pressure release membrane (PTFE) 220 L HDPE drums with HDPE screw cap (with pressure release membrane); 1 000 L HDPE IBC with HDPE screw cap (with pressure release vent) and outlet opening with butterfly valve.
4.1.1.   Use-specific instructions

Thoroughly clean the surfaces to be disinfected.

Remove a cleaning agent, if used, with clean water.

Remove excess of water.

Prepare a dilution of the product manually in a bucket, watering can, trigger spray or knapsack sprayer:

  • — for bacteria and yeasts: dilute the product to 3 % (v/v; 30 ml product, add water to 1 litre).
  • — for bacteria, yeasts and fungi: dilute the product to 12 % (v/v; 120 ml product, add water to 1 litre).
  • — for bacteria, yeasts, fungi and viruses: dilute the product to 18 % (v/v; 180 ml product, add water to 1 litre).
  • — for bacteria, mycobacteria, yeasts, fungi and viruses: dilute the product to 21 % (v/v; 210 ml product, add water to 1 litre).

or

Prepare a dilution of the product in a bucket, watering can, trigger spray or knapsack sprayer by means of an automated dosage system according to the use instructions of the apparatus.

Subsequently pour the diluted product on the floor or apply the product with a trigger spray or knapsack sprayer. Make sure that the surface remains wet for at least 5 minutes.

The dilution is intended for immediate use.

Where gas filters (RPE) are required, training must be ensured for the users.

4.1.2.   Use-specific risk mitigation measures

Mixing and loading – Manual (undiluted):

  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — The use of eye protection (chemical goggles) consistent with EN 166 or equivalent during handling of the product is mandatory.
  • — Ensure adequate ventilation (at least 3 air changes per hour) during mixing and loading.
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent providing a protection factor of 4 is mandatory. At least a powered air purifying respirator with helmet, hood, or mask (TH1 or TM1), or a half mask or full mask with gas filter is required.
  • — Wear a protective coverall (at least type 4, consistent with EN 14605 or equivalent) which is impermeable for the biocidal product (coverall material to be specified by the authorisation holder within the product information).

21 % in-use dilution

Mixing and loading – Manual:

  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — The use of eye protection (chemical goggles) consistent with EN 166 or equivalent during handling of the product is mandatory.
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent is mandatory.

Application – spraying – trigger spray (21 % dilution):

  • — Spraying is only allowed in the downward or horizontal direction.
  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — The use of eye protection (chemical goggles) consistent with EN 166 or equivalent during handling of the product is mandatory.
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent is mandatory. If the product is used in rooms < 100 m3 with a ventilation of < 3 air changes per hour a protection factor of 10 is mandatory. At least a powered air purifying respirator with helmet, hood, or mask (TH1 or TM1), or a half mask or full mask with gas filter is required.
  • — Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m3) or relevant lower national reference value.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

Application – spraying – Knapsack or backpack sprayer:

  • — Spraying is only allowed in the downward or horizontal direction with a lance sprayer.
  • — The flow rate of the backpack sprayer must not exceed 0,3 l/min.
  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — The use of eye protection (chemical goggles) consistent with EN 166 or equivalent during handling of the product is mandatory.
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent is mandatory.
  • — Wear chemical resistant boots consistent with EN 13832 or equivalent during product handling phase.
  • — Wear a protective coverall (at least type 4, consistent with EN 14605 or equivalent) which is impermeable for the biocidal product (coverall material to be specified by the authorisation holder within the product information).
  • — Use only in rooms with a volume ≥ 1 000 m3.
  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

Application – mopping and wiping:

  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — The use of eye protection (chemical goggles) consistent with EN 166 or equivalent during handling of the product is mandatory.
  • — Wear chemical resistant boots consistent with EN 13832 or equivalent during product handling phase.
  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent is mandatory. If the product is used in rooms < 1 000 m3, a protection factor of 10 is mandatory. At least a powered air purifying respirator with helmet, hood or mask (TH1 or TM1), or a half mask or full mask with gas filter is required.
  • — Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m3) or relevant lower national reference value.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

Application – pouring:

  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — The use of eye protection (chemical goggles) consistent with EN 166 or equivalent during handling of the product is mandatory.
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent is mandatory.
  • — Wear chemical resistant boots consistent with EN 13832 or equivalent during product handling phase.
  • — Ensure adequate ventilation (at least 3 air changes per hour) during application.
  • — Use only in rooms with a volume ≥ 1 000 m3.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

18 % in-use dilution

Application – spraying – trigger spray:

  • — Spraying is only allowed in the downward or horizontal direction.
  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent providing a protection factor of 10 is mandatory if the product is used in rooms < 100 m3 with a ventilation of < 3 air changes per hour. At least a powered air purifying respirator with helmet, hood, or mask (TH1 or TM1), or a half mask or full mask with gas filter is required.
  • — Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m3) or relevant lower national reference value.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

Application – spraying – Knapsack or backpack sprayer:

  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — The flow rate of the backpack sprayer must not exceed 0,3 l/min.
  • — Spraying is only allowed in the downward or horizontal direction.
  • — Use only in rooms with a volume ≥ 1 000 m3.
  • — No access of third parties during application or treatment.
  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — Do not use near domestic animals or livestock.

Application – mopping and wiping:

  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent providing a protection factor of 10 is mandatory if the product is used in rooms < 1 000 m3. At least a powered air purifying respirator with helmet, hood or mask (TH1 or TM1), or a half mask or full mask with gas filter is required.
  • — Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m3) or relevant lower national reference value.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

Application – pouring:

  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — Ensure adequate ventilation (at least 3 air changes per hour) during application.
  • — Use only in rooms with a volume ≥ 1 000 m3.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

12 % in-use dilution

Application – spraying – trigger spray:

  • — Spraying is only allowed in the downward or horizontal direction.
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent providing a protection factor of 4 is mandatory if the product is used in rooms < 100 m3 with a ventilation of < 3 air changes per hour. At least a powered air purifying respirator with helmet, hood, or mask (TH1 or TM1), or a half mask or full mask with gas filter is required.
  • — Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m3) or relevant lower national reference value.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

Application – spraying – Knapsack or backpack sprayer:

  • — Spraying is only allowed in the downward or horizontal direction.
  • — The flow rate of the backpack sprayer must not exceed 0,3 l/min.
  • — Use only in rooms with a volume ≥ 1 000 m3.
  • — No access of third parties during application or treatment.
  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — Do not use near domestic animals or livestock.

Application – mopping and wiping:

  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open). Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent providing a protection factor of 4 is mandatory if the product is used in rooms < 1 000 m3. At least a powered air purifying respirator with helmet, hood or mask (TH1 or TM1), or a half mask or full mask with gas filter is required.
  • — Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m3) or relevant lower national reference value.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

Application – pouring:

  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — Use only in rooms with a volume ≥ 1 000 m3.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

3 % in-use dilution

Application – spraying – trigger spray:

  • — Spraying is only allowed in the downward or horizontal direction.
  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

Application – spraying – Knapsack or backpack sprayer:

  • — Spraying is only allowed in the downward or horizontal direction.
  • — The flow rate of the backpack sprayer must not exceed 0,3 l/min.
  • — Use only in rooms with a volume ≥ 1 000 m3.
  • — No access of third parties during application or treatment.
  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — Do not use near domestic animals or livestock.

Application – mopping and wiping:

  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

Application – pouring:

  • — Ensure adequate ventilation (at least 3 air changes per hour) during application.
  • — Use only in rooms with a volume ≥ 1 000 m3.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

When means of protection are indicated, these measures are without prejudice to the application of Council Directive 98/24/EC and other Union legislation in the area of health and safety at work. See section 6 for the full references to this act and the EN standards.

4.1.3.   Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment

See General directions for use of the meta SPC.

4.1.4.   Where specific to the use, the instructions for safe disposal of the product and its packaging

Keep only in original container Empty container completely. Keep labels on container. Dispose the container in accordance with the regulations issued by the appropriate authorities.

4.1.5.   Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage

See storage conditions in section General directions for use of the meta SPC.

4.2.   Use description

Table 2
Disinfection of hard surfaces in non-food industry and laboratories
Product type PT02: Disinfectants and algaecides not intended for direct application to humans or animals
Where relevant, an exact description of the authorised use —
Target organism(s) (including development stage) Scientific name: no data Common name: Bacteria Development stage: no data Scientific name: no data Common name: Yeasts Development stage: no data Scientific name: no data Common name: Fungi Development stage: no data Scientific name: no data Common name: Mycobacteria Development stage: no data Scientific name: no data Common name: Viruses Development stage: no data
Field(s) of use Indoor use Disinfection of hard non-porous surfaces in non-food industry and laboratories.
Application method(s) Method: Manual application by pouring or spraying (trigger spray or knapsack sprayer). Manual application by pouring or spraying followed by wiping or mopping. Detailed description: —
Application rate(s) and frequency Application rate: Trigger spray: 0,030 - 0,060 litre/m2 Watering can: 0,19 - 1,92 litre/m2 Knapsack or backpack spray: 0,181 litre/m2 Pouring or spraying followed by wiping or mopping: 0,030 - 0,060 litre/m2 Dilution: 3 % - 21 % Number and timing of application: Apply in addition to daily cleaning; 10 applications per day shall not be exceeded. Temperature: room temperature.
Category(ies) of users Professional
Pack sizes and packaging material 1 L HDPE bottle with screw cap (outer cap HDPE, inner cap PPC, with LDPE or PE foam liner as pressure release valve) 5, 10 and 20 L HDPE cans with screw cap (HDPE) with inlay (PE foam) and pressure release membrane (PTFE) 220 L HDPE drums with HDPE screw cap (with pressure release membrane); 1 000 L HDPE IBC with HDPE screw cap (with pressure release vent) and outlet opening with butterfly valve.
4.2.1.   Use-specific instructions

Thoroughly clean the surfaces to be disinfected.

Remove a cleaning agent, if used, with clean water.

Remove excess of water.

Prepare a dilution of the product manually in a bucket, watering can, trigger spray or knapsack sprayer:

  • — for bacteria and yeasts: dilute the product to 3 % (v/v; 30 ml product, add water to 1 litre).
  • — for bacteria, yeasts, and fungi: dilute the product to 12 % (v/v; 120 ml product, add water to 1 litre).
  • — for bacteria, yeasts, fungi, and viruses: dilute the product to 18 % (v/v; 180 ml product, add water to 1 litre).
  • — for bacteria, mycobacteria, yeasts, fungi, and viruses: dilute the product to 21 % (v/v; 210 ml product, add water to 1 litre).

or

Prepare a dilution of the product in a bucket, watering can, trigger spray or knapsack sprayer by means of an automated dosage system according to the use instructions of the apparatus.

Subsequently pour the diluted product on the floor or apply the product with a trigger spray or knapsack sprayer. Make sure that the surface remains wet for at least 5 minutes.

The dilution is intended for immediate use.

Where gas filters (RPE) are required, training must be ensured for the users.

4.2.2.   Use-specific risk mitigation measures

Mixing and loading – Manual (undiluted):

  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — The use of eye protection (chemical goggles) consistent with EN 166 or equivalent during handling of the product is mandatory.
  • — Ensure adequate ventilation (at least 3 air changes per hour) during mixing and loading.
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent providing a protection factor of 4 is mandatory. At least a powered air purifying respirator with helmet, hood, or mask (TH1 or TM1), or a half mask or full mask with gas filter is required.
  • — Wear a protective coverall (at least type 4, consistent with EN 14605 or equivalent) which is impermeable for the biocidal product (coverall material to be specified by the authorisation holder within the product information).

21 % in-use dilution

Mixing and loading – Manual:

  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — The use of eye protection (chemical goggles) consistent with EN 166 or equivalent during handling of the product is mandatory.
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent is mandatory.

Application – spraying – trigger spray (21 % dilution):

  • — Spraying is only allowed in the downward or horizontal direction.
  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — The use of eye protection (chemical goggles) consistent with EN 166 or equivalent during handling of the product is mandatory.
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent is mandatory. If the product is used in rooms < 100 m3 with a ventilation of < 3 air changes per hour a protection factor of 10 is mandatory. At least a powered air purifying respirator with helmet, hood, or mask (TH1 or TM1), or a half mask or full mask with gas filter is required.
  • — Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m3) or relevant lower national reference value.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

Application – spraying – Knapsack or backpack sprayer:

  • — Spraying is only allowed in the downward or horizontal direction with a lance sprayer.
  • — The flow rate of the backpack sprayer must not exceed 0,3 l/min.
  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — The use of eye protection (chemical goggles) consistent with EN 166 or equivalent during handling of the product is mandatory.
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent is mandatory.
  • — Wear chemical resistant boots consistent with EN 13832 or equivalent during product handling phase.
  • — Wear a protective coverall (at least type 4, consistent with EN 14605 or equivalent) which is impermeable for the biocidal product (coverall material to be specified by the authorisation holder within the product information).
  • — Use only in rooms with a volume ≥ 1 000 m3.
  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

Application – mopping and wiping:

  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — The use of eye protection (chemical goggles) consistent with EN 166 or equivalent during handling of the product is mandatory.
  • — Wear chemical resistant boots consistent with EN 13832 or equivalent during product handling phase.
  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent is mandatory. If the product is used in rooms < 1 000 m3, a protection factor of 10 is mandatory. At least a powered air purifying respirator with helmet, hood or mask (TH1 or TM1), or a half mask or full mask with gas filter is required.
  • — Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m3) or relevant lower national reference value.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

Application – pouring:

  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — The use of eye protection (chemical goggles) consistent with EN 166 or equivalent during handling of the product is mandatory.
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent is mandatory.
  • — Wear chemical resistant boots consistent with EN 13832 or equivalent during product handling phase.
  • — Ensure adequate ventilation (at least 3 air changes per hour) during application.
  • — Use only in rooms with a volume ≥ 1 000 m3.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

18 % in-use dilution

Application – spraying – trigger spray:

  • — Spraying is only allowed in the downward or horizontal direction.
  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent providing a protection factor of 10 is mandatory if the product is used in rooms < 100 m3 with a ventilation of < 3 air changes per hour. At least a powered air purifying respirator with helmet, hood, or mask (TH1 or TM1), or a half mask or full mask with gas filter is required.
  • — Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m3) or relevant lower national reference value.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

Application – spraying – Knapsack or backpack sprayer:

  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — The flow rate of the backpack sprayer must not exceed 0,3 l/min.
  • — Spraying is only allowed in the downward or horizontal direction.
  • — Use only in rooms with a volume ≥ 1 000 m3.
  • — No access of third parties during application or treatment.
  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — Do not use near domestic animals or livestock.

Application – mopping and wiping:

  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent providing a protection factor of 10 is mandatory if the product is used in rooms < 1 000 m3. At least a powered air purifying respirator with helmet, hood or mask (TH1 or TM1), or a half mask or full mask with gas filter is required.
  • — Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m3) or relevant lower national reference value.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

Application – pouring:

  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — Ensure adequate ventilation (at least 3 air changes per hour) during application.
  • — Use only in rooms with a volume ≥ 1 000 m3.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

12 % in-use dilution

Application – spraying – trigger spray:

  • — Spraying is only allowed in the downward or horizontal direction.
  • — Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent providing a protection factor of 4 is mandatory if the product is used in rooms < 100 m3 with a ventilation of < 3 air changes per hour. At least a powered air purifying respirator with helmet, hood, or mask (TH1 or TM1), or a half mask or full mask with gas filter is required.
  • — Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m3) or relevant lower national reference value.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

Application – spraying – Knapsack or backpack sprayer:

  • — Spraying is only allowed in the downward or horizontal direction.
  • — The flow rate of the backpack sprayer must not exceed 0,3 l/min.
  • — Use only in rooms with a volume ≥ 1 000 m3.
  • — No access of third parties during application or treatment.
  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — Do not use near domestic animals or livestock.

Application – mopping and wiping:

  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).Use of respiratory protective equipment (RPE) consistent with EN 12941 or equivalent providing a protection factor of 4 is mandatory if the product is used in rooms < 1 000 m3. At least a powered air purifying respirator with helmet, hood or mask (TH1 or TM1), or a half mask or full mask with gas filter is required.
  • — Re-entry is only permitted once the air concentration for hydrogen peroxide has dropped below 0,9 ppm (1,25 mg/m3) or relevant lower national reference value.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

Application – pouring:

  • — Provide ventilation of 3 air changes per hour (industrial ventilation or keeping windows and doors open).
  • — Use only in rooms with a volume ≥ 1 000 m3.
  • — No access of third parties during application or treatment.
  • — Do not use near domestic animals or livestock.

3 % in-use dilution

Application – spraying – trigger spray:

  • — Spraying is only allowed in the downward or horizontal direction.
  • — Wear protective chemical resistant gloves consistent with EN ISO 374 or equivalent during product handling phase.
  • — No access of third parties during application or treatment.

Reading this document does not replace reading the official text published in the Official Journal of the European Union. We assume no responsibility for any inaccuracies arising from the conversion of the original to this format.

This text is published under EUR-Lex's own terms of reuse, not a Legalize or public-domain licence. EUR-Lex
Creative Commons Attribution 4.0 International (CC BY 4.0)
© European Union, https://eur-lex.europa.eu — Source: EUR-Lex (Publications Office of the European Union). Reused under the Creative Commons Attribution 4.0 International (CC BY 4.0) licence. Only EU legislation published in the printed Official Journal of the European Union is deemed authentic; consolidated texts are reproduced here for documentation purposes and have been reformatted to Markdown.