The Smoke Control Areas (Exempted Fireplaces) (England) Order 2015

Type Statutory-Instrument
Publication 2015-02-16
State In force
Department King's Printer of Acts of Parliament
PDF Download
articles Not indexed
Reform history JSON API
Fireplace Conditions Conditions Conditions
Talbott 500 Hot-air Heater (afterburn model) manufactured by Talbott’s Heating Limited The manufacturer’s instructions dated January 1st 1983, reference: A1000. The afterburn cycle must last not less than 25 minutes and must come into operation each time the loading door is opened. The manufacturer’s instructions dated January 1st 1983, reference: A1000. The afterburn cycle must last not less than 25 minutes and must come into operation each time the loading door is opened. Wood offcuts, woodwaste, pallets or chipboard[^f01000]
Talbott Pirojet P150 Heater manufactured by Talbott’s Heating Limited The manufacturer’s instructions dated February 1987, reference: No. P150-2-87. When the appliance is used to burn chipboard, an afterburner which is supplied with the appliance and which must be capable of continuously producing 20 megajoules of heat per hour must be used. The appliance must not be used to burn sawdust in bulk. The manufacturer’s instructions dated February 1987, reference: No. P150-2-87. When the appliance is used to burn chipboard, an afterburner which is supplied with the appliance and which must be capable of continuously producing 20 megajoules of heat per hour must be used. The appliance must not be used to burn sawdust in bulk. Hardwood offcuts, softwood offcuts or chipboard[^f01000]
Talbott Pirojet P300 Heater manufactured by Talbott’s Heating Limited The manufacturer’s instructions dated February 1987, reference: No. P300-2-87. When the appliance is used to burn chipboard, an afterburner which is supplied with the appliance and which must be capable of continuously producing 40 megajoules of heat per hour must be used. The appliance must not be used to burn sawdust in bulk. The manufacturer’s instructions dated February 1987, reference: No. P300-2-87. When the appliance is used to burn chipboard, an afterburner which is supplied with the appliance and which must be capable of continuously producing 40 megajoules of heat per hour must be used. The appliance must not be used to burn sawdust in bulk. Hardwood offcuts, softwood offcuts or chipboard[^f01000]
Talbott Pirojet P600 Heater manufactured by Talbott’s Heating Limited The manufacturer’s instructions dated December 1986, reference: No. P600-12-86. When the appliance is used to burn chipboard, an afterburner which is supplied with the appliance and which must be capable of continuously producing 75 megajoules of heat per hour must be used. The appliance must not be used to burn sawdust in bulk. The manufacturer’s instructions dated December 1986, reference: No. P600-12-86. When the appliance is used to burn chipboard, an afterburner which is supplied with the appliance and which must be capable of continuously producing 75 megajoules of heat per hour must be used. The appliance must not be used to burn sawdust in bulk. Hardwood offcuts, softwood offcuts or chipboard[^f01000]
Talbott’s Automatic Biomass Air Heaters models T1.5/A, T3/A, T5/A and TM/A formerly manufactured by Talbott’s Heating Ltd and now manufactured by Talbott’s Biomass Energy Systems Ltd, Tollgate Drive, Tollgate Industrial Estate, Stafford ST16 3HS The manufacturer’s instructions, reference: T/A JANUARY 1990 The manufacturer’s instructions, reference: T/A JANUARY 1990 Hardwood or softwood shavings or sawdust[^f01000]
Talbott’s Biomass Energy Models C1, C2, C3 and C4 formerly manufactured by Talbott’s Heating Ltd and now manufactured by Talbott’s Biomass Energy Systems Ltd, Tollgate Drive, Tollgate Industrial Estate, Stafford ST16 3HS The manufacturer’s instructions dated August 1995, reference: Issue C1000/C/Range The manufacturer’s instructions dated August 1995, reference: Issue C1000/C/Range Chipboard, wood shavings or forestry chips[^f01000]
Talbott’s combustion unit, models C1, C2, C3 and C4 manufactured by Talbott’s Heating Limited The manufacturer’s instructions dated August 1995, reference: Issue C1000/C/Range The manufacturer’s instructions dated August 1995, reference: Issue C1000/C/Range Chipboard, wood shavings or forestry chips[^f01000]
Talbott’s Combustion Units, models CM1, CM2, CM3 and CM4, manufactured by Talbott’s Heating Limited The manufacturer’s instructions dated August 1997, reference: Issue CM897 The manufacturer’s instructions dated August 1997, reference: Issue CM897 Woodwaste, pallets, medium density fibreboard or untreated and air-dried wood offcuts[^f01000]
Talbott’s Energy Saving Wood Waste Burning Automatic Hot Water Heaters, models T1.5/AB, T3/AB, T5/AB and TM/AB, manufactured by Talbott’s Heating Limited The manufacturer’s instructions dated October 1993, reference: Issue A1001 The manufacturer’s instructions dated October 1993, reference: Issue A1001 Hardwood shavings, softwood shavings or sawdust[^f01000]
Talbott’s Energy Saving Wood Waste Burning Automatic Warm Air Heaters, models T1.5/A, T3/A, T5/A and TM/A, manufactured by Talbott’s Heating Limited The manufacturer’s instructions dated January 1990, reference: T/A The manufacturer’s instructions dated January 1990, reference: T/A Hardwood shavings, softwood shavings or sawdust[^f01000]
Talbott’s Heating models D250B, D500B and D700B, manufactured by Talbott’s Heating Limited The manufacturer’s instructions dated 1st January 1995, reference: Gen/Tech. The manufacturer’s instructions dated 1st January 1995, reference: Gen/Tech. Hardwood offcuts, softwood offcuts or chipboard[^f01000]
Talbott’s model T75, T150, T300 Biomass Air Heaters formerly manufactured by Talbott’s Heating Ltd and now manufactured by Talbott’s Biomass Energy Systems Ltd, Tollgate Drive, Tollgate Industrial Estate, Stafford ST16 3HS The manufacturer’s instructions dated 1st January 1995, reference: models T75, T150 and T300 ‘gen/sttech’ The manufacturer’s instructions dated 1st January 1995, reference: models T75, T150 and T300 ‘gen/sttech’ Wood offcuts, wood waste pallets or chipboard[^f01000]
Talbott’s T500 Biomass Air Heater (afterburn model) formerly manufactured by Talbott’s Heating Ltd and now manufactured by Talbott’s Biomass Energy Systems Ltd, Tollgate Drive, Tollgate Industrial Estate, Stafford ST16 3HS The manufacturer’s instructions dated 1st January 1983, reference: A10000. The afterburn cycle shall last not less than 25 minutes and must come into operation each time the loading door is opened. The manufacturer’s instructions dated 1st January 1983, reference: A10000. The afterburn cycle shall last not less than 25 minutes and must come into operation each time the loading door is opened. Wood offcuts, wood waste, pellets or chipboard[^f01000]
Talbott’s Warm Air Heaters Down Firing Range, models D250, D500 and D700, manufactured by Talbott’s Heating Limited The manufacturer’s instructions dated May 1991, reference: No. D257 The manufacturer’s instructions dated May 1991, reference: No. D257 Hardwood offcuts, softwood offcuts or chipboard[^f01000]
Talbott T5-1M Automatic Heater manufactured by Talbott’s Heating Limited The manufacturer’s instructions dated January 1989, reference: T5-A-1-89. The manufacturer’s instructions dated January 1989, reference: T5-A-1-89. Hardwood shavings, softwood shavings or chipboard dust[^f01000]
Termatech TT20, TT20Bazic, TT20R, TT20S, TT20RS and TT20SA woodburning stoves manufactured by TermaTech A/S, Jegstrupvej 60, DK-8361 Hasselager, Denmark User and mounting manual dated July 2014, reference: 99-275 UK version. The damper control unit referenced in the manufacturer’s manual must be installed. User and mounting manual dated July 2014, reference: 99-275 UK version. The damper control unit referenced in the manufacturer’s manual must be installed. Wood logs[^f01000]
Termatech TT22 and TT22S convection wood-burning stoves manufactured by TermaTech A/S, Jegstrupvej 60, DK-8361 Hasselager, Denmark User and mounting manual for stove models TT22 and TT22S dated July 2014, reference: 99-234 UK version. The appliance must be fitted with a smoke control kit to prevent closure of the primary and secondary air controls beyond the 25% open position. User and mounting manual for stove models TT22 and TT22S dated July 2014, reference: 99-234 UK version. The appliance must be fitted with a smoke control kit to prevent closure of the primary and secondary air controls beyond the 25% open position. Wood logs[^f01000]
Termosuprema Compact DSA manufactured by La Nordica S.p.A., Via Summano, 104 – 36030, Montecchio Precalcino, Vicenza, Italy Instruction manual dated 1st January 2011, reference: 7095802 Rev. 06 Instruction manual dated 1st January 2011, reference: 7095802 Rev. 06
Therminator II 22 and Therminator II 30 Boiler manufactured by Solarfocus, Werkstrasse 1, 4451 St.Ulrich, Steyr, Austria Installation instructions dated July 2006, reference: Version 11/08/06. Operating manual dated September 2009, reference: V8.051. Maintenance instructions dated 2006, reference: Ver 1st September 2006 Installation instructions dated July 2006, reference: Version 11/08/06. Operating manual dated September 2009, reference: V8.051. Maintenance instructions dated 2006, reference: Ver 1st September 2006 Wood pellets[^f01000]
Therminator II 27 and Therminator II 36 Boiler manufactured by Solarfocus, Werkstrasse 1, 4451 St.Ulrich, Steyr, Austria Installation instructions dated July 2006, reference: Version 11/08/06. Operating manual dated September 2009, reference: V8.051. Maintenance instructions dated 2006, reference: Ver 1st September 2006. Installation instructions dated July 2006, reference: Version 11/08/06. Operating manual dated September 2009, reference: V8.051. Maintenance instructions dated 2006, reference: Ver 1st September 2006. Wood logs[^f01000]
Therminator II 40 Boiler manufactured by Solarfocus, Werkstrasse 1, 4451 St.Ulrich, Steyr, Austria Installation instructions dated July 2006, reference: Version 11/08/06. Operating manual dated September 2009, reference: V8.051. Maintenance instructions dated 2006, reference: Ver 1st September 2006. Installation instructions dated July 2006, reference: Version 11/08/06. Operating manual dated September 2009, reference: V8.051. Maintenance instructions dated 2006, reference: Ver 1st September 2006. Wood pellets or wood chips[^f01000]
Therminator II 49 and Therminator II 60 Boiler manufactured by Solarfocus, Werkstrasse 1, 4451 St.Ulrich, Steyr, Austria Installation instructions dated July 2006, reference: Version 11/08/06. Operating manual dated September 2009, reference: V8.051. Maintenance instructions dated 2006, reference: Ver 1st September 2006. Installation instructions dated July 2006, reference: Version 11/08/06. Operating manual dated September 2009, reference: V8.051. Maintenance instructions dated 2006, reference: Ver 1st September 2006. Wood logs or wood pellets or wood chips[^f01000]
Thornhill T3 small manufactured by Thornhill Eco Design Ltd 58/60 Winsheap, Canterbury, Kent CT1 3RS Instruction manual dated January 2011, reference: ED/11/05. The appliance must be fitted with an air plate that prevents the teriary air controller from closing more than 17 mm and opening more than 45 mm. Instruction manual dated January 2011, reference: ED/11/05. The appliance must be fitted with an air plate that prevents the teriary air controller from closing more than 17 mm and opening more than 45 mm. Wood logs[^f01000]
Tiger GH-T Insert Stove manufactured by Hughes Design Limited, Denver House, Winster, Derbyshire, DE4 2DH Instruction manual dated 22nd January 2014, reference: Tiger solid fuel heating stoves inset multi-fuel models incorporating GH-T Firebox. Solid Fuel Stoves Manual v12. Advice sheet dated 22nd January 2014, reference: Soliftec Smoke Advice Sheet no 1. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 5mm open position. Instruction manual dated 22nd January 2014, reference: Tiger solid fuel heating stoves inset multi-fuel models incorporating GH-T Firebox. Solid Fuel Stoves Manual v12. Advice sheet dated 22nd January 2014, reference: Soliftec Smoke Advice Sheet no 1. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 5mm open position. Wood logs[^f01000]
Tiger SuperClean stove manufactured by Tiger stoves, Focus Arts & Crafts Co, Industrial Area Gao Zhuangzi Village, Xin Zhuang Town, Jin Nan District, Tianjin, P.R.China 300350 Instruction manual dated April 2010, reference: INSTALLATION AND OPERATING INSTRUCTIONS document v. 148 Instruction manual dated April 2010, reference: INSTALLATION AND OPERATING INSTRUCTIONS document v. 148 Wood logs[^f01000]
Trash X Incinerator, models TX25, TX35, TX50, TX35L and TX50L, manufactured by Roscoe Fabrications Limited The manufacturer’s instructions dated 1998, reference: TX/1998 The manufacturer’s instructions dated 1998, reference: TX/1998 Untreated dry wood
Trianco “Coal King” Boiler manufactured by Trianco Redfyre Limited Installation instructions dated May 1983, reference: 47664. User instructions dated May 1983, reference: 47665. Installation instructions dated May 1983, reference: 47664. User instructions dated May 1983, reference: 47665. Selected washed coal doubles or Union Coal Briketts manufactured by Rheinbraun AG of Germany and comprising lignite compressed into briquettes of approximately 15 centimetres in length with square ends and with a sulphur content not exceeding 1%.
Trianco Greenflame 15 wood pellet boiler manufactured by T.R. Engineering Ltd, Unit 7, Newton Chambers Way, Thorncliffe Industrial Estate, Chapeltown, Sheffield, S35 2PH Instruction manual dated 25th June 2012, reference: Item No. 400001 Iss. 2. Instruction manual dated 25th June 2012, reference: Item No. 400001 Iss. 2. 6 mm wood pellets[^f01000]
Trianco Greenflame 18 Slim Wood Pellet Boiler manufactured by T.R Engineering Ltd, Unit 7 Newton Chambers Way, Thorncliffe Industrial Estate, Chapeltown, Sheffield, S35 2PH Installation and Operation manual for Greenflame 18 Slim Wood Pellet Boiler dated June 2014, reference: V.1.1 Installation and Operation manual for Greenflame 18 Slim Wood Pellet Boiler dated June 2014, reference: V.1.1 Wood pellets[^f01000]
Trianco Greenflame 55, 85, 100, 125 and 199 Wood Pellet Boilers manufactured by Wood Energy Solutions Limited, Donaskeigh, Tipperary, Co. Tipperary, Ireland Installation, operation and servicing instructions dated May 2012, reference: Manual Edition: Greenflame Commercial Services Installation, operation and servicing instructions dated May 2012, reference: Manual Edition: Greenflame Commercial Services Wood pellets[^f01000]
Trianco TGB 17 manufactured by Trianco Limited The manufacturer’s instructions The manufacturer’s instructions Selected washed coal singles and doubles
Triancomatic 140 boiler manufactured by Trianco Redfyre Limited Installation instructions dated November 1986, reference: No. 48375. User instructions dated November 1986, reference: No. 48374. Installation instructions dated November 1986, reference: No. 48375. User instructions dated November 1986, reference: No. 48374. Washed coals recommended in user instructions, reference No. 48374
Triancomatic 45 boiler manufactured by Trianco Redfyre Limited Installation instructions dated September 1989, reference: No. 44359. User instructions dated September 1989, reference: No.44358. Installation instructions dated September 1989, reference: No. 44359. User instructions dated September 1989, reference: No.44358. The washed coals recommended in user instructions reference No. 44358
Triancomatic 60 boiler manufactured by Trianco Redfyre Limited Installation instructions dated 24th July 1985, reference: 45576. User instructions dated 24th July 1985, reference: 45574. Installation instructions dated 24th July 1985, reference: 45576. User instructions dated 24th July 1985, reference: 45574. Washed coals recommended in user instructions reference 45574
Triancomatic 90 boiler manufactured by Trianco Redfyre Limited Installation instructions dated July 1987, reference: No. 46576. User instructions dated July 1987, reference: No. 46574. Installation instructions dated July 1987, reference: No. 46576. User instructions dated July 1987, reference: No. 46574. Washed coals recommended in user instructions reference 46574
Triancomatic T80 manufactured by Trianco Limited The manufacturer’s instructions. The manufacturer’s instructions. Selected washed coal singles and doubles
Tripp TR5i Multi-fuel inset stove manufactured by Heat Design Limited, 30-60 Hawthorn Road, Western Industrial Estate, Naas Road, Dublin 12, Ireland Installation and operating instruction manual dated 2nd May 2013, reference: TR5i, The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 3.5 mm open position. Installation and operating instruction manual dated 2nd May 2013, reference: TR5i, The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 3.5 mm open position. Wood logs[^f01000]
Turbhogar Alfa 80T and 65T, Turbhogar Beta 80T, Turbhogar Delta 80T and 65T, Turbhogar Lamda 80T and 65T, Turbhogar Sigma 80T and 65T, Turbhogar Omega 80T and Turbhogar Tau 80T and 65T fireplace inserts manufactured by Rofer and Rodi UK Ltd, Unit 10, Millennium Road, Airedale Business Centre, Skipton, North Yorkshire BD23 2TZ Manual of assembly and use dated 20th September 2010, reference: RR 100920, and supplementary instruction manual of the same date, reference: UK 100920. The appliance must be fitted with a system that prevents the full closure of the air control opening so that the air openings remain 3 mm (30%) open at the minimum setting. Manual of assembly and use dated 20th September 2010, reference: RR 100920, and supplementary instruction manual of the same date, reference: UK 100920. The appliance must be fitted with a system that prevents the full closure of the air control opening so that the air openings remain 3 mm (30%) open at the minimum setting. Wood logs[^f01000]
Turbo Heat, models 1000 and 1200, manufactured by CBR Engineers Limited The manufacturer’s instructions, reference: CBR “TURBO” HEAT 1000 to 1200 1990 The manufacturer’s instructions, reference: CBR “TURBO” HEAT 1000 to 1200 1990 Hardwood offcuts, softwood offcuts or chipboard[^f01000]
Turco Woodsman 18 Slim Wood Pellet Boiler manufactured by Wood Energy Solutions Limited, Donaskeigh, Tipperary, Co. Tipperary, Ireland Installation & Operation manual for Woodsman 18 Slim Wood Pellet Boiler dated June 2014 reference: V.1.1 Installation & Operation manual for Woodsman 18 Slim Wood Pellet Boiler dated June 2014 reference: V.1.1 Wood pellets[^f01000]
Turkington Engineering Woodlander 28 Wood Pellet Boiler manufactured by Wood Energy Solutions Limited, Donaskeigh, Tipperary, Co. Tipperary, Ireland Installation and Operation manual dated July 2013, reference: Version 2.1 Installation and Operation manual dated July 2013, reference: Version 2.1 Wood pellets[^f01000]
Turkington Engineering Woodlander 55, 85, 100, 125 and 199 Wood Pellet Boilers manufactured by Wood Energy Solutions Limited, Donaskeigh, Tipperary, Co. Tipperary, Ireland Installation, operation and servicing instructions dated July 2013, reference: Manual Edition: Woodlander Commercial Series Installation, operation and servicing instructions dated July 2013, reference: Manual Edition: Woodlander Commercial Series Wood pellets[^f01000]
Twin Heat CS150i manufactured by TWIN HEAT A/S, Nørrevangen 7, DK-9631 Gedsted, Denmark Operating instructions dated 17th December 2008, reference: Version 6.0.03 Operating instructions dated 17th December 2008, reference: Version 6.0.03 Wood pellets of a maximum length of 30 mm and diameter of 6 mm and conforming to CEN/TS 14961:2005[^f01000]
Uniconfort EOS 45, EOS 50, EOS 55, EOS 65, EOS 70, EOS 75, EOS 80, EOS 85 boilers fitted with a multi-cyclone manufactured by Uniconfort srl, Via dell’Industria, 21, 35018 San Martino di Lupari, PD, Italy Instruction manual dated May 2012, reference: Uniconfort EOS MANUAL: R1 Instruction manual dated May 2012, reference: Uniconfort EOS MANUAL: R1 Wood pellets[^f01000]
Uniconfort EOS 90 boiler fitted with a multi-cyclone manufactured by Uniconfort srl, Via dell’Industria, 21, 35018 San Martino di Lupari, PD, Italy Instruction manual dated May 2012, reference: Uniconfort EOS MANUAL: R1 Instruction manual dated May 2012, reference: Uniconfort EOS MANUAL: R1 Wood pellets or wood chips[^f01000]
Varde Aura Ovne 1 (VD-AURA1), 2 (VD-AURA2), 3 (VD-AURA3) and 11 (VD-AURA11) wood burning 5 kW stoves manufactured by Varde Ovne A/S, Kongevej 246, DK-6510 Gram, Denmark Installation and user guide dated 26th July 2010, reference: FOR-177 GB 2 edition. Additional Installation and user instructions for use in Smoke Control Areas dated July 2014, reference: Varde Aura 2. edition FOR-177 GB PM1053 Issue 2. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 50% open position. Installation and user guide dated 26th July 2010, reference: FOR-177 GB 2 edition. Additional Installation and user instructions for use in Smoke Control Areas dated July 2014, reference: Varde Aura 2. edition FOR-177 GB PM1053 Issue 2. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 50% open position. Wood logs[^f01000]
Varde Ovne Fuego 1 (VD-FUEGO1) and 2 (VD-FUEGO1) wood burning 5 kW stoves manufactured by Varde Ovne A/S, Kongevej 246, DK-6510 Gram, Denmark Installation and user guide dated 15th May 2013, reference: Varde Fuego Revision 2. Additional Installation and user Instructions for use in Smoke Control Areas dated July 2014, reference: Varde Fuego - Revision 02 Installation and User Guide PM1062 Issue 2. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 50% open position. Installation and user guide dated 15th May 2013, reference: Varde Fuego Revision 2. Additional Installation and user Instructions for use in Smoke Control Areas dated July 2014, reference: Varde Fuego - Revision 02 Installation and User Guide PM1062 Issue 2. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 50% open position. Wood logs[^f01000]
Varde Ovne Shape 1 (VD-SHAPE1B) and 2 (VD-SHAPE2B) wood burning 5 kW stoves manufactured by Varde Ovne A/S, Kongevej 246, DK-6510 Gram, Denmark Installation and user guide dated 18th June 2009, reference: FOR-176 GB 1 edition. Additional Installation and user Instructions for use in Smoke Control Areas dated July 2014, reference: Varde Shape 1. edition FOR-176 GB PM1054 Issue 2. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 37.5% open position. Installation and user guide dated 18th June 2009, reference: FOR-176 GB 1 edition. Additional Installation and user Instructions for use in Smoke Control Areas dated July 2014, reference: Varde Shape 1. edition FOR-176 GB PM1054 Issue 2. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 37.5% open position. Wood logs[^f01000]
Varde Ovne Uniq 1 (VD-UNIQ1) wood burning 5.4 kW stove manufactured by Varde Ovne A/S, Kongevej 246, DK-6510 Gram, Denmark Installation and user guide dated 3rd June 2014, reference: Revision 6. Additional Installation and user Instructions for use in Smoke Control Areas dated July 2014, reference: Varde Uniq - Revision 4 Installation and User Guide PM1055 Issue 2. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 30% open position. Installation and user guide dated 3rd June 2014, reference: Revision 6. Additional Installation and user Instructions for use in Smoke Control Areas dated July 2014, reference: Varde Uniq - Revision 4 Installation and User Guide PM1055 Issue 2. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 30% open position. Wood logs[^f01000]
VarioWIN VA 12 kW wood pellet boiler manufactured by Windhager Zentralheizung GmbH, Anton-Windhager Str.20, A-5201 Seerkirchen bei Salzburg, Austria Installation instruction manual dated January 2010, reference: 092947/00. Operating instruction manual dated January 2010, reference: 092945/00 Installation instruction manual dated January 2010, reference: 092947/00. Operating instruction manual dated January 2010, reference: 092945/00 Wood pellets[^f01000], 6 mm diameter, length 80% between 15-30 mm and a density of at least 1.1kg.dm3
Vecto D and Vecto M 6kW free standing wood-burning stoves manufactured by Dan Skan GmbH, Burgwedeler Str. 7-8, D-30657 Hannover, Germany Instruction manual dated November 2014, reference: DSB2-Defra/UK-NI-ROI/V1.11.14. The appliance must be modified to prevent closure of the air flow control valve below position 2. Instruction manual dated November 2014, reference: DSB2-Defra/UK-NI-ROI/V1.11.14. The appliance must be modified to prevent closure of the air flow control valve below position 2. Wood logs[^f01000]
Vega 100 Clean Burn II stove manufactured by Percy Doughty & Co Limited, Imperial Point, Express Trading Estate, Stone Hill Road, Farnworth, Bolton, BL4 9TN Instruction manual dated January 2013, reference: Vega 100 Clean Burn II Installation and Operation Instructions REV: D. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 50% open position. Instruction manual dated January 2013, reference: Vega 100 Clean Burn II Installation and Operation Instructions REV: D. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 50% open position. Wood logs[^f01000]
Vega 200 Clean Burn stove manufactured by Percy Doughty & Co Limited, Imperial Point, Express Trading Estate, Stone Hill Road, Farnworth, Bolton, BL4 9TN Instruction manual dated January 2013, reference: Vega 200 Clean Burn Installation and Operation Instructions REV: D. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 50% open position. Instruction manual dated January 2013, reference: Vega 200 Clean Burn Installation and Operation Instructions REV: D. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 50% open position. Wood logs[^f01000]
Vega Amor 100 4.9kW multi-fuel stove manufactured by Percy Doughty & Co Limited, Imperial Point, Express Trading Estate, Stone Hill Road, Farnworth, Bolton, BL4 9TN Instruction manual dated December 2014, reference: AMOR100 REV:B. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 50% open position. Instruction manual dated December 2014, reference: AMOR100 REV:B. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 50% open position. Wood logs[^f01000]
Vega Edge 100 4.9kW multi-fuel stove manufactured by Percy Doughty & Co Limited, Imperial Point, Express Trading Estate, Stone Hill Road, Farnworth, Bolton, BL4 9TN Instruction manual dated December 2014, reference: VEGA EDGE 100 INSTRUCTION – REV.B. The appliance must be fitted with a permanent stop to modify the secondary air control closure to a minimum of 7mm open. Instruction manual dated December 2014, reference: VEGA EDGE 100 INSTRUCTION – REV.B. The appliance must be fitted with a permanent stop to modify the secondary air control closure to a minimum of 7mm open. Wood logs[^f01000]
Vermont Castings Defiant model 1975 catalytic wood-burning stove manufactured by Vermont Castings Group, 62 Vermont Castings Road, Bethel, Vermont, 05032, United States of America Homeowner’s installation and operating manual dated July 2013, reference: 30005554 7/13 Rev. 10. The appliance must be operated with the catalyst and fitted with a system that prevents closure of the air control lever beyond the 25 mm (5 o’clock) open position. Homeowner’s installation and operating manual dated July 2013, reference: 30005554 7/13 Rev. 10. The appliance must be operated with the catalyst and fitted with a system that prevents closure of the air control lever beyond the 25 mm (5 o’clock) open position. Wood logs[^f01000]
Vermont Castings Encore model 2040 catalytic wood-burning stove manufactured by Vermont Castings Group, 62 Vermont Castings Road, Bethel, Vermont, 05032, United States of America Homeowner’s installation and operating manual dated July 2013, reference: 30005552 7/13 Rev. 9. The appliance must be operated with the catalyst. Homeowner’s installation and operating manual dated July 2013, reference: 30005552 7/13 Rev. 9. The appliance must be operated with the catalyst. Wood logs[^f01000]
Vesuvio 400 kW automatic pizza oven manufactured by CLM Bakery System srl, Via Monteli, 3 - 33092 Meduno (PN), Italy and previously manufactured by CLM srl, Via I Maggio 35, 31043, Fontanelle (Treviso), Italy CLM Vesuvio oven instruction manual dated 29th November 2011, reference: Instruction and maintenance manual ENGLISH version Review 0.1 CLM Vesuvio oven instruction manual dated 29th November 2011, reference: Instruction and maintenance manual ENGLISH version Review 0.1 ‘CalorPan’ 100% beech briquette, octagonal section, length 260-300 mm, width and height 75-90 mm. manufactured from dried beech sawdust[^f01000]
View 3 (3.8 kW) and View 5 (4.9 kW) multifuel stoves manufactured by Stovax Limited, Falcon Road, Sowton Industrial Estate, Exeter, Devon, EX2 7LF Instruction manual dated June 2010, reference: PM485 Issue 1. Smoke control kit instruction manual dated June 2010, reference: PM490 Issue 1. A permanent stop must be positioned to prevent closure of the secondary air control below the 50% open position. Instruction manual dated June 2010, reference: PM485 Issue 1. Smoke control kit instruction manual dated June 2010, reference: PM490 Issue 1. A permanent stop must be positioned to prevent closure of the secondary air control below the 50% open position. Wood logs[^f01000]
View 5 (4.9 kW) wood stove manufactured by Stovax Limited, Falcon Road, Sowton Industrial Estate, Exeter, Devon, EX2 7LF Instruction manual dated June 2010, reference: PM485 Issue 1. Smoke control kit instruction manual dated June 2010, reference: PM490 Issue 1. A permanent stop must be positioned to prevent closure of the secondary air control below the 50% open position Instruction manual dated June 2010, reference: PM485 Issue 1. Smoke control kit instruction manual dated June 2010, reference: PM490 Issue 1. A permanent stop must be positioned to prevent closure of the secondary air control below the 50% open position Wood logs[^f01000]
View 7 (7 kW) inset appliance Product code VW-7NMF manufactured by Stovax Limited, Falcon Road, Sowton Industrial Estate, Exeter, Devon, EX2 7LF Instruction manual dated June 2011, reference: PM552 - Issue 1. Smoke control kit instruction manual dated July 2011, reference: PM490 Issue 2. A permanent stop must be in place on the secondary air inlet to prevent closure beyond the 50% open position. Instruction manual dated June 2011, reference: PM552 - Issue 1. Smoke control kit instruction manual dated July 2011, reference: PM490 Issue 2. A permanent stop must be in place on the secondary air inlet to prevent closure beyond the 50% open position. Wood logs[^f01000]
Vista Magnifico SE and Vista Perfetto SE 4.9 kW Wood Burning Stove manufactured by Newman Fireplaces, Ltd, Units 6 and 7 Rawreth Barns, Dollymans Farm, Doublegate Lane, Rawreth, Wickford, Essex, SS11 8UD Newman Fireplaces Limited’s Instruction manual dated 24th October 2011, reference: 1-2. The appliance must be fitted with mechanical stops to prevent closure of the secondary air control beyond the 30% open position and the tertiary air beyond the 50% open position. Newman Fireplaces Limited’s Instruction manual dated 24th October 2011, reference: 1-2. The appliance must be fitted with mechanical stops to prevent closure of the secondary air control beyond the 30% open position and the tertiary air beyond the 50% open position. Wood logs[^f01000]
Vista Magnifico SE NS-1 and Vista Perfetto SE NS-2 4.9kW multi-fuel stoves manufactured by Newman Fireplaces Ltd, Units 6 and 7 Rawreth Barns, Dollymans Farm, Doublegate Lane, Rawreth, Wickford, Essex, SS11 8UD Installation and user instruction manual dated 3rd June 2014, reference: NS-1, NS-2 Edition: 2. The appliance must be fitted with mechanical stops to prevent closure of the secondary air control beyond the 30% open position and the tertiary air beyond the 50% open position. Installation and user instruction manual dated 3rd June 2014, reference: NS-1, NS-2 Edition: 2. The appliance must be fitted with mechanical stops to prevent closure of the secondary air control beyond the 30% open position and the tertiary air beyond the 50% open position. Wood logs[^f01000]
Vitae 06C inset stove manufactured by Heat Design, 30 Hawthorn Road, Western Industrial Estate, Naas Road, Dublin 12, Ireland Instruction manual dated 26th July 2012, reference: VIT06C. A permanent stop to prevent closure of the secondary air control beyond 20% open must be implemented Instruction manual dated 26th July 2012, reference: VIT06C. A permanent stop to prevent closure of the secondary air control beyond 20% open must be implemented Wood logs[^f01000]
Vitae 11C inset stove manufactured by Heat Design, 30 Hawthorn Road, Western Industrial Estate, Naas Road, Dublin 12, Ireland Instruction manual dated 26th July 2012, reference: VIT11C. A permanent stop to prevent closure of the secondary air control beyond 20% open must be implemented. Instruction manual dated 26th July 2012, reference: VIT11C. A permanent stop to prevent closure of the secondary air control beyond 20% open must be implemented. Wood logs[^f01000]
Vitoligno 300-P models 12, 18, 24, 32, 40 and 48 pellet boilers manufactured by Viessmann Limited, Hortonwood 30, Telford, TF1 7YP Vitoligno 300-P operating instructions dated January 2014 reference: 5592 617 GB. Vitoligno 300-P Technical guide dated January 2014, reference: 5414 644 GB Vitoligno 300-P operating instructions dated January 2014 reference: 5592 617 GB. Vitoligno 300-P Technical guide dated January 2014, reference: 5414 644 GB Wood pellets[^f01000]
Warmflow WS18 and WP18 Pellet Boilers manufactured by Warmflow Engineering Co Limited, Lissue Industrial Estate, Moira Road, Lisburn Northern Ireland, BT28 2RF Boiler Manual for Wood Pellet Boiler WS18/WP18 dated May 2014, reference: CODE 4220 Issue 1 Boiler Manual for Wood Pellet Boiler WS18/WP18 dated May 2014, reference: CODE 4220 Issue 1 Wood pellets[^f01000]
Westcott 5SE manufactured by Dimplex, GDC Group Ltd, Millbrook House, Grange Drive, Hedge End, Southampton SO30 2DF Instruction manual dated 7th September 2010, reference: 08/51351/0 – Issue 0 Instruction manual dated 7th September 2010, reference: 08/51351/0 – Issue 0 Wood logs[^f01000]
Westfire Series One stove and Westfire Series Two stove manufactured by Westfire, Tømrervej 3, DK-6800 Varde, Denmark Westfire WF One and Two series installation manual and operating instructions and supplementary instruction manual dated 1st June 2011, reference: Westfire supplementary instructions June 2011/Version 1. The appliance must be fitted with a permanent stop to prevent closure of the secondary air control less than 50% open. Westfire WF One and Two series installation manual and operating instructions and supplementary instruction manual dated 1st June 2011, reference: Westfire supplementary instructions June 2011/Version 1. The appliance must be fitted with a permanent stop to prevent closure of the secondary air control less than 50% open. Wood logs[^f01000]
Westfire Uniq 15, 16 and 20 (also known as WF UNIQ 15, 16 and 20) manufactured by Westfire Tømrervej 3 DK-6800 Varde, Denmark Installation and operating instructions dated 2007, reference: WF15–WF16–WF20, together with supplementary instructions dated 2007, reference: 01wfuk.2007. A permanent stop must be in place on the secondary air inlet to prevent closure beyond 50 mm. Installation and operating instructions dated 2007, reference: WF15–WF16–WF20, together with supplementary instructions dated 2007, reference: 01wfuk.2007. A permanent stop must be in place on the secondary air inlet to prevent closure beyond 50 mm. Untreated dry wood
Westfire Uniq 18 Westfire Uniq 17 Westfire Uniq 19 Westfire Uniq 23 Westfire Uniq 23 side Glass Westfire Uniq 23 Inset stoves manufactured by Westfire APS Tømrervej 3 DK-6800 Varde Denmark Instruction manual reference: WESTFIRE SUPPLEMENTARY INSTRUCTIONS JUNE 2010. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air slide beyond the 30 mm open position. Instruction manual reference: WESTFIRE SUPPLEMENTARY INSTRUCTIONS JUNE 2010. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air slide beyond the 30 mm open position. Wood logs[^f01000]
Westfire Uniq 21 stove, Westfire Uniq 21 pedestal stove and Westfire Uniq 21 wall hung stove manufactured by Westfire, Tømrervej 3, DK-6800 Varde, Denmark Westfire WF21 installation manual and operating instructions and supplementary instruction manual dated 1st June 2011, reference: Westfire supplementary instructions June 2011/Version 1. The appliance must be fitted with a permanent stop to prevent closure of the secondary air control less than 60% open. Westfire WF21 installation manual and operating instructions and supplementary instruction manual dated 1st June 2011, reference: Westfire supplementary instructions June 2011/Version 1. The appliance must be fitted with a permanent stop to prevent closure of the secondary air control less than 60% open. Wood logs[^f01000]
Westfire Uniq 26 stove, Westfire Uniq 27 stove and Westfire Uniq 28 stove manufactured by Westfire, Tømrervej 3, DK-6800 Varde, Denmark Westfire WF26, WF27, WF28 installation manual and operating instructions and supplementary instruction manual dated 1st June 2011, reference: Westfire supplementary instructions June 2011/Version 1. The appliance must be fitted with a permanent stop to the secondary air slider control to prevent closure more than 20 mm from the fully closed position. Westfire WF26, WF27, WF28 installation manual and operating instructions and supplementary instruction manual dated 1st June 2011, reference: Westfire supplementary instructions June 2011/Version 1. The appliance must be fitted with a permanent stop to the secondary air slider control to prevent closure more than 20 mm from the fully closed position. Wood logs[^f01000]
Westfire Uniq 32 Inset stove and Westfire Uniq 32 Freestanding stove manufactured by Westfire, Tømrervej 3, DK-6800 Varde, Denmark Westfire WF23/Uniq23, WF32/Uniq 32 inset stove installation manual and operating instructions and supplementary Instruction manual dated 1st June 2011, reference: Westfire supplementary instructions June 2011/Version 1. The appliance must be fitted with a permanent stop to prevent closure of the secondary air control less than 50% open. Westfire WF23/Uniq23, WF32/Uniq 32 inset stove installation manual and operating instructions and supplementary Instruction manual dated 1st June 2011, reference: Westfire supplementary instructions June 2011/Version 1. The appliance must be fitted with a permanent stop to prevent closure of the secondary air control less than 50% open. Wood logs[^f01000]
Westfire Uniq 33 SE, Westfire Uniq 33 side glass SE, Westfire Uniq 34 SE, and Westfire Uniq 34 side glass SE multi-fuel 6.1 kW stoves manufactured by Westfire, Tømrervej 3, VARDE, DK-6800, Denmark Installation manual and operating instructions dated 2012, reference: UNIQ33/34V1 Installation manual and operating instructions dated 2012, reference: UNIQ33/34V1 Wood logs[^f01000]
Westfire Uniq 35 SE Freestanding multi-fuel 4.3 kW stove, Westfire Uniq 35 SE Pedestal multi-fuel 4.3kW stove, Westfire Uniq 35 SE Inset with 3 sided frame multi-fuel 4.3kW stove, and Westfire Uniq 35 SE Inset with 4 sided frame multi-fuel 4.3kW stove manufactured by Westfire, Tomrervej 3, VARDE, DK-6800, Denmark Installation manual and operating instructions dated 2013, reference: WF35. The appliance must be fitted with the manufacturer’s smoke reduction kit to prevent closure of the secondary air control beyond the 25% open position. Installation manual and operating instructions dated 2013, reference: WF35. The appliance must be fitted with the manufacturer’s smoke reduction kit to prevent closure of the secondary air control beyond the 25% open position. Wood logs[^f01000]
Windhager BioWin 100, 150, 210 and 260 boilers manufactured by Windhager Zentralheizung GmbH, Anton-Windhager- Str. 20, A-5201 Seerkirchen bei Salzburg, Austria The manufacturer’s instruction manual dated May 2008, reference: 0916197/00 The manufacturer’s instruction manual dated May 2008, reference: 0916197/00 Wood pellets[^f01000]
Windhager BioWIN 350, 450 and 600 35, 45 and 60 kW pellet boilers manufactured by Windhager Zentralheizung GmbH, Anton-Windhager-Str. 20, A-5201 Seerkirchen bei Salzburg, Austria BioWIN operating manual dated July 2013, reference: 093209/02. BioWIN installation instruction manual dated July 2013, reference: 093212/04. BioWIN operating manual dated July 2013, reference: 093209/02. BioWIN installation instruction manual dated July 2013, reference: 093212/04. Wood pellets[^f01000]
Windhager FireWIN 90 and 120 manufactured by Windhager Zentralheizung GmbH, Anton-Windhager- Str. 20, A-5201 Seerkirchen bei Salzburg, Austria The manufacturer’s instruction manual dated August 2008, reference: 092125/00 The manufacturer’s instruction manual dated August 2008, reference: 092125/00 Wood pellets[^f01000]
Wood Chip Fired Air Heater manufactured by Air Plants Limited The manufacturer’s instructions as to operation (if any) The manufacturer’s instructions as to operation (if any) Wood waste[^f01000]
Wood Energy Solutions E-Compact 15 Slim and 18 Slim Wood Pellet Boilers manufactured by Wood Energy Solutions Limited, Donaskeigh, Tipperary, Co. Tipperary, Ireland Installation and Operation manual for E-Compact 15/18 Slim Wood Pellet Boiler dated June 2014, reference: V.1.1 Installation and Operation manual for E-Compact 15/18 Slim Wood Pellet Boiler dated June 2014, reference: V.1.1 Wood pellets[^f01000]
Wood Energy Solutions E-Compact 55 Wood Pellet Boiler manufactured by Wood Energy Solutions Limited, Donaskeigh, Tipperary, Co. Tipperary, Ireland Installation and operating manual dated December 2012, reference: Manual Edition : E-COMPACT 55_December 2012 Issue 1 Installation and operating manual dated December 2012, reference: Manual Edition : E-COMPACT 55_December 2012 Issue 1 Wood pellets[^f01000]
Wood Energy Solutions E-Compact 85, 100 and 125 Wood Pellet Boilers manufactured by Wood Energy Solutions Limited, Donaskeigh, Tipperary, Co. Tipperary, Ireland Installation and operating manual dated May 2012, reference: Manual Edition : E-COMPACT Commercial Series_85-125 Installation and operating manual dated May 2012, reference: Manual Edition : E-COMPACT Commercial Series_85-125 Wood pellets[^f01000]
Wood Energy Solutions E-Compact 199 Wood Pellet Boiler manufactured by Wood Energy Solutions Limited, Donaskeigh, Tipperary, Co. Tipperary, Ireland Installation and operating manual dated May 2012, reference: Manual Edition : E-COMPACT Commercial Series_199 Installation and operating manual dated May 2012, reference: Manual Edition : E-COMPACT Commercial Series_199 Wood pellets[^f01000]
Wood Fired Ovens by Jamie Oliver Ltd’s GR Valoriani Ristorante 100 and OT Valoriani Ristorante 100 manufactured by Valoriani of Via Caselli alla Fornace 213, 50066 Reggello, Firenze, Italy Instruction manual dated January 2011, reference: OOLinst.8 GR 100 and OT 100 v2 Instruction manual dated January 2011, reference: OOLinst.8 GR 100 and OT 100 v2 Untreated dry wood with a maximum moisture content of 20%
Wood Fired Ovens by Jamie Oliver Ltd’s GR Valoriani Ristorante 120 and OT Valoriani Ristorante 120 manufactured by Valoriani of Via Caselli alla Fornace 213, 50066 Reggello, Firenze, Italy Instruction manual dated January 2011, reference: OOLinst.9 GR 120 and OT 120 v2 Instruction manual dated January 2011, reference: OOLinst.9 GR 120 and OT 120 v2 Untreated dry wood with a maximum moisture content of 20%
Wood Fired Ovens by Jamie Oliver Ltd’s GR Valoriani Ristorante 120x160 and OT Valoriani Ristorante 120x160 manufactured by Valoriani of Via Caselli alla Fornace 213, 50066 Reggello, Firenze, Italy Instruction manual dated January 2011, reference: OOLinst.11 GR 120x160 and OT 120x160 v2 Instruction manual dated January 2011, reference: OOLinst.11 GR 120x160 and OT 120x160 v2 Untreated dry wood with a maximum moisture content of 20%
Wood Fired Ovens by Jamie Oliver Ltd’s GR Valoriani Ristorante 140 and OT Valoriani Ristorante 140 manufactured by Valoriani of Via Caselli alla Fornace 213, 50066 Reggello, Firenze, Italy Instruction manual dated January 2011, reference: OOLinst.10 GR 140 and OT 140 v2 Instruction manual dated January 2011, reference: OOLinst.10 GR 140 and OT 140 v2 Untreated dry wood with a maximum moisture content of 20%
Wood Fired Ovens by Jamie Oliver Ltd’s GR Valoriani Ristorante 140x160 and OT Valoriani Ristorante 140x160 manufactured by Valoriani of Via Caselli alla Fornace 213, 50066 Reggello, Firenze, Italy Instruction manual dated January 2011, reference: OOLinst.12 GR 140x160 and OT 140x160 v2 Instruction manual dated January 2011, reference: OOLinst.12 GR 140x160 and OT 140x160 v2 Untreated dry wood with a maximum moisture content of 20%
Wood Fired Ovens by Jamie Oliver Ltd’s GR Valoriani Ristorante 140x180 and OT Valoriani Ristorante 140x180 manufactured by Valoriani of Via Caselli alla Fornace 213, 50066 Reggello, Firenze, Italy Instruction manual dated January 2011, reference: OOLinst.13 GR 140x180 and OT 140x180 v2 Instruction manual dated January 2011, reference: OOLinst.13 GR 140x180 and OT 140x180 v2 Untreated dry wood with a maximum moisture content of 20%
Wood Fired Ovens by Jamie Oliver Ltd’s GR Valoriani Ristorante 180 and OT Valoriani Ristorante 180 manufactured by Valoriani of Via Caselli alla Fornace 213, 50066 Reggello, Firenze, Italy Instruction manual dated January 2011, reference: OOLinst.14 GR 180 and OT 180 v2 Instruction manual dated January 2011, reference: OOLinst.14 GR 180 and OT 180 v2 Untreated dry wood with a maximum moisture content of 20%
Wood Fired Ovens by Jamie Oliver Ltd’s Valoriani Casa 100 manufactured by Valoriani of Via Caselli alla Fornace 213, 50066 Reggello, Firenze, Italy Instruction manual dated January 2011, reference: OOLinst.2 FVR 100 v2 Instruction manual dated January 2011, reference: OOLinst.2 FVR 100 v2 Untreated dry wood with a maximum moisture content of 20%
Wood Fired Ovens by Jamie Oliver Ltd’s Valoriani Casa 110 manufactured by Valoriani of Via Caselli alla Fornace 213, 50066 Reggello, Firenze, Italy Instruction manual dated January 2011, reference: OOLinst.3 FVR 110 v2 Instruction manual dated January 2011, reference: OOLinst.3 FVR 110 v2 Untreated dry wood with a maximum moisture content of 20%
Wood Fired Ovens by Jamie Oliver Ltd’s Valoriani Casa 110x160 manufactured by Valoriani of Via Caselli alla Fornace 213, 50066 Reggello, Firenze, Italy Instruction manual dated January 2011, reference: OOLinst.5 FVR 110x160 v2 Instruction manual dated January 2011, reference: OOLinst.5 FVR 110x160 v2 Untreated dry wood with a maximum moisture content of 20%
Wood Fired Ovens by Jamie Oliver Ltd’s Valoriani Casa 120 manufactured by Valoriani of Via Caselli alla Fornace 213, 50066 Reggello, Firenze, Italy Instruction manual dated January 2011, reference: OOLinst.4 FVR 120 v2 Instruction manual dated January 2011, reference: OOLinst.4 FVR 120 v2 Untreated dry wood with a maximum moisture content of 20%
Wood Fired Ovens by Jamie Oliver Ltd’s Valoriani Casa 80 manufactured by Valoriani of Via Caselli alla Fornace 213, 50066 Reggello, Firenze, Italy Instruction manual dated January 2011, reference: OOLinst.1 FVR 80 v2 Instruction manual dated January 2011, reference: OOLinst.1 FVR 80 v2 Untreated dry wood with a maximum moisture content of 20%
Wood Fired Ovens by Jamie Oliver Ltd’s Valoriani Piccolo manufactured by Valoriani of Via Caselli alla Fornace 213, 50066 Reggello, Firenze, Italy Instruction manual dated January 2011, reference: OOLinst.15 Valoriani Piccolo v2 Instruction manual dated January 2011, reference: OOLinst.15 Valoriani Piccolo v2 Untreated dry wood with a maximum moisture content of 20%
Fireplace Conditions Conditions Conditions
Wood Fired Ovens by Jamie Oliver Ltd’s Valoriani Villa 100 manufactured by Valoriani of Via Caselli alla Fornace 213, 50066 Reggello, Firenze, Italy Instruction manual dated January 2011, reference: OOLinst.6 TOP 100 v2 Instruction manual dated January 2011, reference: OOLinst.6 TOP 100 v2 Untreated dry wood with a maximum moisture content of 20%
Wood Fired Ovens by Jamie Oliver Ltd’s Valoriani Villa 120 manufactured by Valoriani of Via Caselli alla Fornace 213, 50066 Reggello, Firenze, Italy Instruction manual dated January 2011, reference: OOLinst.7 TOP 120 v2 Instruction manual dated January 2011, reference: OOLinst.7 TOP 120 v2 Untreated dry wood with a maximum moisture content of 20%
Wood Stone Ovens, models WS-MS-4-W (Mt. Chuckanut), WS-MS-5-W (Mt. Adams), WS-MS-6-W (Mt. Baker) and WS-MS-7-W (Mt. Rainier), manufactured by the Wood Stone Corporation, USA The manufacturer’s instructions dated 8th September 1998, reference: BPWS version 1 The manufacturer’s instructions dated 8th September 1998, reference: BPWS version 1 Untreated dry wood logs
Wood Waste Technology Heater, models WT10 and WT15, manufactured by Wood Waste Technology Limited, Units 1 & 2, Drummond Road, Astonfields Industrial Estate, Stafford, Staffordshire ST16 3HJ The manufacturer’s instructions dated 19th January 2005, reference: WT10 and WT15 The manufacturer’s instructions dated 19th January 2005, reference: WT10 and WT15 Medium density fibreboard, chipboard and hard and softwood offcuts[^f01000]
Wood Waste Technology Ltd WT5 manufactured by Wood Waste Technology Limited, Units 1 & 2, Drummond Road, Astonfields Industrial Estate, Stafford, Staffordshire ST16 3HJ The manufacturer’s instructions dated 16th February 2009, reference: WT5_v2 The manufacturer’s instructions dated 16th February 2009, reference: WT5_v2 Medium density fibreboard, chipboard and hard and softwood offcuts [^f01000]
Wood Waste Technology WW199 (199kW output) biomass boiler and cyclone manufactured by Wood Waste Technology Limited, Units 1, 2 and 3 Drummond Road, Astonfields Industrial Estate, Stafford, ST16 3HJ Instruction manual dated 11th July 2014, reference: “WW199 Biomass Water Heating O&M Manual” Revision C. Instruction manual dated 11th July 2014, reference: “WW199 Biomass Water Heating O&M Manual” Revision C. Chipboard, medium density fibreboard, softwood or hardwood, which has been chipped to a length not exceeding 15 mm, has a moisture content not exceeding 30% of the total weight and has a fines (sawdust) content not exceeding 50% of the total weight[^f01000]
Woodpecker 15, 25 and 45 wood pellet boilers manufactured by Woodpecker Energy UK, Abbey Manor Business Centre Preston Road. Yeovil. BA20 2EN. Previously manufactured by Garranlea Renewables Ltd of Barnard, Garranlea, New Inn, Cashel, Co. Tipperary, Ireland Instruction manual dated May 2012, reference: Installation and Operating Manual Issue 6 Instruction manual dated May 2012, reference: Installation and Operating Manual Issue 6 Wood pellets conforming to CEN/TS 14961[^f01000]
Woodpecker 50 kW wood pellet boilers manufactured by Woodpecker Energy UK, Abbey Manor Business Centre, Preston Road, Yeovil, Somerset. BA20 2EN Instruction manual dated May 2012, reference: Installation and Operating Manual Woodpecker 50 Model Wood Pellet Boiler System Version 2 Instruction manual dated May 2012, reference: Installation and Operating Manual Woodpecker 50 Model Wood Pellet Boiler System Version 2 Wood pellets conforming to CEN/TS 14961[^f01000]
Woodpecker Thermon 150 boiler manufactured by Woodpecker Energy UK, Abbey Manor Business Centre Preston Road. Yeovil. BA20 2EN Instruction manual dated February 2012, reference: Installation and Operating Manual Issue 2 Instruction manual dated February 2012, reference: Installation and Operating Manual Issue 2 6 mm wood pellets[^f01000]
Woodpecker Thermon 199 kW pellet boiler manufactured by Woodpecker Energy UK, Abbey Manor Business Centre Preston Road, Yeovil. BA20 2EN Instruction manual dated February 2012, reference: Issue 2.0 Instruction manual dated February 2012, reference: Issue 2.0 6 mm wood pellets[^f01000]
Woodpecker Thermon 200 boiler manufactured by Woodpecker Energy UK, Abbey Manor Business Centre Preston Road. Yeovil. BA20 2EN Instruction manual dated February 2012, reference: Installation and Operating Manual Issue 2 Instruction manual dated February 2012, reference: Installation and Operating Manual Issue 2 6 mm wood pellets[^f01000]
Woodpecker Thermon 250 boiler manufactured by Woodpecker Energy UK, Abbey Manor Business Centre, Preston Road. Yeovil. BA20 2EN Instruction manual dated February 2012, reference: Installation and Operating Manual Issue 2 Instruction manual dated February 2012, reference: Installation and Operating Manual Issue 2 6 mm wood pellets[^f01000]
Woodpecker Thermon 300 boiler manufactured by Woodpecker Energy UK, Abbey Manor Business Centre, Preston Road. Yeovil. BA20 2EN Instruction manual dated February 2012, reference: Installation and Operating Manual Issue 2 Instruction manual dated February 2012, reference: Installation and Operating Manual Issue 2 6 mm wood pellets[^f01000]
Woodwarm stoves Firebright SE multifuel insert stove manufactured by Metal Developments Ltd, The Workshop, Wheatcroft Farm, Cullompton, Devon, EX15 1RA The installation and operating instruction manual dated 1st June 2013, reference: Version INSSE. The appliance must be modified to prevent closure of the existing secondary air slide plate, located beneath the appliance, beyond the 3 mm open position. The installation and operating instruction manual dated 1st June 2013, reference: Version INSSE. The appliance must be modified to prevent closure of the existing secondary air slide plate, located beneath the appliance, beyond the 3 mm open position. Wood logs[^f01000]
Woodwarm stoves Firegem, Firewren and Fireblaze SE multifuel stoves manufactured by Metal Developments Ltd, The Workshop, Wheatcroft Farm, Cullompton, Devon, EX15 1RA The installation and operating instruction manual dated 1st June 2013, reference: Version FSSE. The appliance must be fitted with a system that prevents closure of the secondary air control beyond the 5 mm open position. The installation and operating instruction manual dated 1st June 2013, reference: Version FSSE. The appliance must be fitted with a system that prevents closure of the secondary air control beyond the 5 mm open position. Wood logs[^f01000]
Woodwarm stoves Foxfire SE woodburning stove manufactured by Metal Developments Ltd, The Workshop, Wheatcroft Farm, Cullompton, Devon, EX15 1RA The installation and operating instructions manual dated 1st June 2013, reference: Version FFSE. The appliance must be modified to prevent closure of the secondary air bleed hole beyond the 75% open position. The installation and operating instructions manual dated 1st June 2013, reference: Version FFSE. The appliance must be modified to prevent closure of the secondary air bleed hole beyond the 75% open position. Wood logs[^f01000]
Worcester Centair 40 Solid Fuel Warm Air Heater manufactured by Worcester Engineering Co. Limited Installation instructions dated July 1983, reference: BC40.1.2. Operating and maintenance instructions dated July 1983, reference: BC40.OM2. Installation instructions dated July 1983, reference: BC40.1.2. Operating and maintenance instructions dated July 1983, reference: BC40.OM2. Union Coal Briketts, manufactured by Rheinbraun AG of Germany and comprising lignite compressed into briquettes of approximately 15 centimetres in length with square ends and with a sulphur content not exceeding 1%
Worcester Coalstream 17.5kW underfeed stoker manufactured by Worcester Engineering Company Limited Installation instructions dated 1st August 1985, reference: ZKLIT 140. User instructions dated 1st August 1985, reference: ZKLIT 139. Installation instructions dated 1st August 1985, reference: ZKLIT 140. User instructions dated 1st August 1985, reference: ZKLIT 139. Washed coals recommended in the user instructions, reference ZKLIT 139
WTA WT Auto 200 kW Airheater manufactured by Wood Waste Technology Limited, Units 1, 2 & 3 Drummond Road, Astonfields Industrial Estate, Stafford, ST16 3HJ Instruction manual dated April 2011, reference: WTA Installation Operation & Maintenance Instructions WTA v1 Issue A Instruction manual dated April 2011, reference: WTA Installation Operation & Maintenance Instructions WTA v1 Issue A Chipboard, Medium Density Fibreboard, Softwood, Hardwood. All fuels to be chipped to a maximum size of 25 mm and a maximum moisture content of 20%. Maximum fines (sawdust) content 5%[^f01000]
WTH 150 and WTH 200 boilers manufactured by Hargassner GmbH, Gunderding 8, A-4952, Weng, Austria The manufacturer’s installation manual version 91 for Large Capacity Boiler WTH 150-200, reference: BA GK V90b 0309 The manufacturer’s installation manual version 91 for Large Capacity Boiler WTH 150-200, reference: BA GK V90b 0309 Wood logs or wood pellets[^f01000]
Xeoos 5 kW stove Versions - Natur, Style, Harmony, Pur, Classic, Elegance and Stone Xeoos 8 kW stove Versions - Basic, Pur, Classic, Elegance Stone and Air Instruction manual references manufactured by Specht Modulare Ofensysteme GmbH & Co, KG Projektmanagement Bahnhofstr. 2 D 35116 Hatzfeld, Germany Instruction manual entitled “Operating and Installation Instructions Xeoos 5 kW/ 8 kW Model 2008”, reference: Revisions – Index 01/08 Fassung Januar 2008 Instruction manual entitled “Operating and Installation Instructions Xeoos 5 kW/ 8 kW Model 2008”, reference: Revisions – Index 01/08 Fassung Januar 2008 Wood logs[^f01000] conforming to DIN 51731
Yeoman CL 7 (7 kW) inset appliance Product code YM-CL7NMF manufactured by Stovax Limited, Falcon Road, Sowton Industrial Estate, Exeter, Devon, EX2 7LF Instruction manual dated June 2011, reference: PM553 - Issue 1. Smoke control kit instruction manual dated June 2011, reference: PM491 Issue 2. A permanent stop must be in place on the secondary air inlet to prevent closure beyond the 50% open position. Instruction manual dated June 2011, reference: PM553 - Issue 1. Smoke control kit instruction manual dated June 2011, reference: PM491 Issue 2. A permanent stop must be in place on the secondary air inlet to prevent closure beyond the 50% open position. Wood logs[^f01000]
Yeoman CL Milner Stove Product code YM-CLMB manufactured by Stovax Limited, Falcon Road, Sowton Industrial Estate, Exeter, Devon, EX2 7LF Instruction manual dated June 2011, reference: PM559 - Issue 1. Smoke control kit instruction manual dated June 2011, reference: PM491 Issue 2. A permanent stop must be positioned to prevent closure of the secondary air control below the 50% open position. Instruction manual dated June 2011, reference: PM559 - Issue 1. Smoke control kit instruction manual dated June 2011, reference: PM491 Issue 2. A permanent stop must be positioned to prevent closure of the secondary air control below the 50% open position. Wood logs[^f01000]
Yeoman CL3 (3.8 kW) and CL5 (4.9 kW) multifuel stoves manufactured by Stovax Limited, Falcon Road, Sowton Industrial Estate, Exeter, Devon, EX2 7LF Instruction manual dated June 2010, reference: PM489 Issue 1. Smoke control kit instruction manual dated 5th April 2010, reference: PM491 Issue 1. A permanent stop must be positioned to prevent closure of the secondary air control below the 50% open position. Instruction manual dated June 2010, reference: PM489 Issue 1. Smoke control kit instruction manual dated 5th April 2010, reference: PM491 Issue 1. A permanent stop must be positioned to prevent closure of the secondary air control below the 50% open position. Wood logs[^f01000]
Yeoman CL5 (4.9 kW) wood Stove manufactured by Stovax Limited, Falcon Road, Sowton Industrial Estate, Exeter, Devon, EX2 7LF Instruction manual dated June 2010, reference: PM489 Issue 1. Smoke control kit instruction manual dated 5th April 2010, reference: PM491 Issue 1. A permanent stop must be positioned to prevent closure of the secondary air control below the 50% open position. Instruction manual dated June 2010, reference: PM489 Issue 1. Smoke control kit instruction manual dated 5th April 2010, reference: PM491 Issue 1. A permanent stop must be positioned to prevent closure of the secondary air control below the 50% open position. Wood logs[^f01000]
Yeoman Devon Multifuel Flat Top 1 Door, Flat Top 2 Door, Low Canopy 1 Door, Low Canopy 2 Door, High Canopy 1 Door and High Canopy 2 Door (9 kW) Stoves manufactured by Stovax Limited, Falcon Road, Sowton Industrial Estate, Exeter, Devon, EX2 7LF Instruction manual dated February 2008, reference: PM184 Issue 3. Smoke control kit instruction manual dated January 2010, reference: PM403 Issue 1. A permanent stop must be positioned to prevent closure of the secondary air control below the 50% open position and a system that ensures a gap of 1 mm for bleed of primary air when the spin wheels are rotated to their fully closed positions. Instruction manual dated February 2008, reference: PM184 Issue 3. Smoke control kit instruction manual dated January 2010, reference: PM403 Issue 1. A permanent stop must be positioned to prevent closure of the secondary air control below the 50% open position and a system that ensures a gap of 1 mm for bleed of primary air when the spin wheels are rotated to their fully closed positions. Wood logs[^f01000]
Yeoman Exe Multifuel Flat Top 1 Door, Flat Top 2 Door, Low Canopy 1 Door and Low Canopy 2 Door (4.9 kW) Stoves manufactured by Stovax Limited, Falcon Road, Sowton Industrial Estate, Exeter, Devon, EX2 7LF Instruction manual dated February 2008, reference: PM184 Issue 3. Smoke control kit instruction manual dated January 2010, reference: PM403 Issue 1. A permanent stop must be positioned to prevent closure of the secondary air control below the 60% open position and a system that prevents full closure of the primary air controls Instruction manual dated February 2008, reference: PM184 Issue 3. Smoke control kit instruction manual dated January 2010, reference: PM403 Issue 1. A permanent stop must be positioned to prevent closure of the secondary air control below the 60% open position and a system that prevents full closure of the primary air controls Wood logs[^f01000]
Yeoman Exmoor Multifuel Flat Top and Multifuel Low Canopy(4.9 kW) Stoves manufactured by Stovax Limited, Falcon Road, Sowton Industrial Estate, Exeter, Devon, EX2 7LF Instruction manual dated February 2008, reference: PM184 Issue 3. Smoke control kit instruction manual dated January 2010, reference: PM403 Issue 1. A permanent stop must be positioned to prevent closure of the secondary air control below the 60% open position and a system that prevents full closure of the primary air controls Instruction manual dated February 2008, reference: PM184 Issue 3. Smoke control kit instruction manual dated January 2010, reference: PM403 Issue 1. A permanent stop must be positioned to prevent closure of the secondary air control below the 60% open position and a system that prevents full closure of the primary air controls Wood logs[^f01000]
York Grande SE, Serrano 7 SE, Monterrey 7 SE and Monroe 7 SE multifuel stoves manufactured by Broseley Fires Ltd, First Floor, Unit B Knights Court, Archers Way, Battlefield Enterprise Park, Shrewsbury, Shropshire, SY1 3GA Instruction manual dated February 2013, reference: GB12A Version 1. The appliance must be fitted with a system that prevents the closure of the secondary air slider beyond the 10 mm open position. Instruction manual dated February 2013, reference: GB12A Version 1. The appliance must be fitted with a system that prevents the closure of the secondary air slider beyond the 10 mm open position. Wood logs[^f01000]
York Midi SE, Serrano 5 SE, Monterrey 5 SE and Monroe 5 SE multifuel stoves manufactured by Broseley Fires Ltd, First Floor, Unit B Knights Court, Archers Way, Battlefield Enterprise Park, Shrewsbury, Shropshire, SY1 3GA Instruction manual dated February 2013, reference: GB12A Version 1. The appliance must be fitted a system that prevents the closure of the secondary air slider beyond the 8 mm open position. Instruction manual dated February 2013, reference: GB12A Version 1. The appliance must be fitted a system that prevents the closure of the secondary air slider beyond the 8 mm open position. Wood logs[^f01000]

SCHEDULE 2 — Revocations

PART 1

PART 2

Signed

Dan Rogerson — Parliamentary Under Secretary of State — Department for Environment, Food and Rural Affairs — 16th February 2015

Explanatory note

(This note is not part of the Order)

EXPLANATORY NOTE

This Order, which applies in England, revokes and replaces the Smoke Control Areas (Exempted Fireplaces) (England) (No. 2) Order 2014 (S.I. 2014/2404) (“the 2014 Order”). It also revokes and replaces numerous earlier Orders relating to smoke control, in so far as they relate to England.

Reading this document does not replace reading the official text published on legislation.gov.uk. Contains public sector information licensed under the Open Government Licence v3.0. We assume no responsibility for any inaccuracies arising from the conversion of the original CLML XML to this format.

This text is published under legislation.gov.uk's own terms of reuse, not a Legalize or public-domain licence. legislation.gov.uk
Open Government Licence v3.0 (attribution required)
© Crown and database right. Derived from content available under the Open Government Licence v3.0 from legislation.gov.uk.