The Smoke Control Areas (Exempted Fireplaces) (England) Order 2015
| Fireplace | Conditions | Conditions | Conditions |
|---|---|---|---|
| Saltfire Aquaburn 20 wood burning stoves manufactured by Saltfire Stoves Ltd, Station Works, Johns Road, Wareham, BH20 4BG | Installation and Operating Instructions dated 22nd January 2014, reference: Saltfire Aquaburn 20 Boiler Wood Version, Manual Version 1.1. The appliance must be fitted with a mechanical stop to prevent air wash control closure beyond the 25 mm open position and a stop preventing manual primary air control closure beyond the 2 mm open position. | Installation and Operating Instructions dated 22nd January 2014, reference: Saltfire Aquaburn 20 Boiler Wood Version, Manual Version 1.1. The appliance must be fitted with a mechanical stop to prevent air wash control closure beyond the 25 mm open position and a stop preventing manual primary air control closure beyond the 2 mm open position. | Wood logs[^f01000] |
| Saltfire Aquaburn 30 wood burning stove manufactured by Saltfire Stoves Ltd, Station Works, Johns Road, Wareham, BH20 4BG | Installation and Operating Instructions dated 22nd January 2014, reference: Saltfire Aquaburn 30 Boiler Wood Version, Manual Version 1.1. The appliance must be fitted with a mechanical stop to prevent air wash control closure beyond the 30 mm open position and a stop preventing manual primary air control closure beyond the 2 mm open position. | Installation and Operating Instructions dated 22nd January 2014, reference: Saltfire Aquaburn 30 Boiler Wood Version, Manual Version 1.1. The appliance must be fitted with a mechanical stop to prevent air wash control closure beyond the 30 mm open position and a stop preventing manual primary air control closure beyond the 2 mm open position. | Wood logs[^f01000] |
| Saltfire Double Sided DS1 wood-burning stove manufactured by Saltfire Stoves Ltd, Station Works, Johns Road, Wareham, BH20 4BG | Installation and operating instruction manual dated 4th July 2013, reference: Saltfire Double Sided DS1 Manual 1.0. The appliance must be modified to prevent closure of the primary and secondary air controls beyond the 3.5 mm open position. A tertiary air control system comprising two 7 mm holes on each side of the appliance and a fixed opening of 4 cm² on the underside of the stove must be implemented. | Installation and operating instruction manual dated 4th July 2013, reference: Saltfire Double Sided DS1 Manual 1.0. The appliance must be modified to prevent closure of the primary and secondary air controls beyond the 3.5 mm open position. A tertiary air control system comprising two 7 mm holes on each side of the appliance and a fixed opening of 4 cm² on the underside of the stove must be implemented. | Wood logs[^f01000] |
| Saltfire Ecoview 12, Fireglow Eco 12, and Ecowarm Crystal 12 stoves (also known as Ekol Crystal 12) manufactured by Saltfire Stoves Limited, Station Works, John’s Road, Wareham, BH20 4BG | Instruction manual dated 15th December 2011, reference: Evoview12 Manual 1.0. The appliance must be fitted with a mechanical stop to prevent closure of the tertiary air control beyond the 4 mm open position. | Instruction manual dated 15th December 2011, reference: Evoview12 Manual 1.0. The appliance must be fitted with a mechanical stop to prevent closure of the tertiary air control beyond the 4 mm open position. | Wood logs[^f01000] |
| Saltfire Ecoview 5, Fireglow Eco 5, and Ecowarm Crystal 5 stoves (also known as Ekol Crystal 5) manufactured by Saltfire Stoves Limited, Station Works, John’s Road, Wareham, BH20 4BG | Instruction manual dated 15th December 2011, reference: Evoview5 Manual 1.0. The appliance must be fitted with a mechanical stop to prevent closure of the tertiary air beyond the 4 mm open position. | Instruction manual dated 15th December 2011, reference: Evoview5 Manual 1.0. The appliance must be fitted with a mechanical stop to prevent closure of the tertiary air beyond the 4 mm open position. | Wood logs[^f01000] |
| Saltfire Oslo-Eco manufactured by Saltfire Stoves Ltd, Station Works, John’s Road, Wareham, BH20 4BG | Instruction manual dated 24th January 2011, reference: ECO7 operation-Revision 2A | Instruction manual dated 24th January 2011, reference: ECO7 operation-Revision 2A | Wood logs[^f01000] |
| Saltfire ST1, Fireglow ST1, and Ultimo ST1 wood burning stoves manufactured by Saltfire Stoves Ltd, Station Works, Johns Road, Wareham, BH20 4BG | Installation and Operating Instructions dated 22nd January 2014, reference: Saltfire ST1, A.K.A Fireglow ST1, A.K.A. Ultimo ST1, Manual Version 1.1. The appliance must be fitted with mechanical stop to prevent air wash control closure beyond the 22 mm open position and a stop to prevent secondary air control closure beyond the 50% open position. | Installation and Operating Instructions dated 22nd January 2014, reference: Saltfire ST1, A.K.A Fireglow ST1, A.K.A. Ultimo ST1, Manual Version 1.1. The appliance must be fitted with mechanical stop to prevent air wash control closure beyond the 22 mm open position and a stop to prevent secondary air control closure beyond the 50% open position. | Wood logs[^f01000] |
| Saltfire ST2, Fireglow ST2, and Ultimo ST2 wood burning stoves manufactured by Saltfire Stoves Ltd, Station Works, Johns Road, Wareham, BH20 4BG | Installation and Operating Instructions dated 22nd January 2014, reference: Saltfire ST2, A.K.A Fireglow ST2, A.K.A. Ultimo ST2, Manual Version 1.1. The appliance must be fitted with a mechanical stop to prevent air wash control closure beyond the 7 mm open position and a stop to prevent tertiary air control closure beyond the 20% open position. | Installation and Operating Instructions dated 22nd January 2014, reference: Saltfire ST2, A.K.A Fireglow ST2, A.K.A. Ultimo ST2, Manual Version 1.1. The appliance must be fitted with a mechanical stop to prevent air wash control closure beyond the 7 mm open position and a stop to prevent tertiary air control closure beyond the 20% open position. | Wood logs[^f01000] |
| Saltfire Sturminster Inset wood-burning stove manufactured by Saltfire Stoves Ltd, Station Works, Johns Road, Wareham, BH20 4BG | Installation and operating instruction manual dated 4th July 2013, reference: Saltfire Sturminster Manual 1.0 | Installation and operating instruction manual dated 4th July 2013, reference: Saltfire Sturminster Manual 1.0 | Wood logs[^f01000] |
| San Remo 4SE stove manufactured by Heat Design, 30 Hawthorn Road, Western Industrial Estate, Naas Road, Dublin 12, Ireland | Instruction manual dated 25th July 2012, reference: SR468SE. The fitting of a system to prevent closure of the secondary air control beyond 5 mm open must be implemented | Instruction manual dated 25th July 2012, reference: SR468SE. The fitting of a system to prevent closure of the secondary air control beyond 5 mm open must be implemented | Wood logs[^f01000] |
| San Remo 6SE stove manufactured by Heat Design, 30 Hawthorn Road, Western Industrial Estate, Naas Road, Dublin 12, Ireland | Instruction manual dated 25th July 2012, reference: SR468SE. The fitting of a system to prevent closure of the secondary air control beyond 75% from closed must be implemented. | Instruction manual dated 25th July 2012, reference: SR468SE. The fitting of a system to prevent closure of the secondary air control beyond 75% from closed must be implemented. | Wood logs[^f01000] |
| San Remo 8SE stove manufactured by Heat Design, 30 Hawthorn Road, Western Industrial Estate, Naas Road, Dublin 12, Ireland | Instruction manual dated 25th July 2012, reference: SR468SE. The fitting of a system to prevent closure of the secondary air control beyond 25% from closed must be implemented. | Instruction manual dated 25th July 2012, reference: SR468SE. The fitting of a system to prevent closure of the secondary air control beyond 25% from closed must be implemented. | Wood logs[^f01000] |
| San Remo SR5i Multi-fuel inset stove manufactured by Heat Design Limited, 30-60 Hawthorn Road, Western Industrial Estate, Naas Road, Dublin 12, Ireland | Installation and operating instruction manual dated 2nd May 2013, reference: SR5i. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 3.5 mm open position. | Installation and operating instruction manual dated 2nd May 2013, reference: SR5i. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 3.5 mm open position. | Wood logs[^f01000] |
| SASP 1000 675kW Biomass Boiler manufactured by Topling d.o.o, Magistralni put BB, 78430 Prnjavor, The Republic of Srpska, Bosnia and Herzegovina | Instruction manual Assembly and Operation Manual dated 12th December 2013, reference: Version TOP/SASP/V.1.1 The appliance must be fitted with the manufacturer’s multi-cyclone. | Instruction manual Assembly and Operation Manual dated 12th December 2013, reference: Version TOP/SASP/V.1.1 The appliance must be fitted with the manufacturer’s multi-cyclone. | Wood chips, which have a moisture content not exceeding 25% of the total weight[^f01000] |
| Scan 58-1, Scan 58-1 Wall, Scan 58-2, Scan 58-2 Wall, Scan 58-3, Scan 58-3 Wall, Scan 58-4, Scan 58-4 Wall, Scan 58-5, Scan 58-5 Wall, Scan 58-6, Scan 58-6 Wall, Scan 58-7, Scan 58-7 High Top, Scan 58-8, Scan 58-8 High Top, Scan 58-9, Scan 58-9 High Top, and Scan 58-10, Scan 58-10 High Top wood-burning stoves manufactured by Scan A/S. Glasvaenget 3-9, 5492 Vissenbjerg, Denmark | Scan 58 assembly and instruction manual dated 24th March 2011, reference: GB 90358500-5. Scan 58 Series supplementary instructions for UK Smoke Control Areas dated 1st March 2013, reference: SCAN58SCA. A mechanical stop to prevent closure of the secondary air control beyond the one-third open position must be implemented. | Scan 58 assembly and instruction manual dated 24th March 2011, reference: GB 90358500-5. Scan 58 Series supplementary instructions for UK Smoke Control Areas dated 1st March 2013, reference: SCAN58SCA. A mechanical stop to prevent closure of the secondary air control beyond the one-third open position must be implemented. | Wood logs[^f01000] |
| Scan 66 Series stove manufactured by Scan A/S Glasvaenget 3-9, 5492 Vissenbjerg, Denmark | Assembly and Instructions manual dated 27th October 2014, reference: GB 90066500. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 35mm open position. | Assembly and Instructions manual dated 27th October 2014, reference: GB 90066500. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 35mm open position. | Wood logs[^f01000] |
| Scan 83-1 stove, Scan 83-2 stove, Scan 83-3 Maxi stove, Scan 83-4 Maxi stove, Scan 83-5 stove, Scan 83-6 stove, Scan 83-7 Maxi stove, and Scan 83-8 Maxi stove manufactured by Scan A/S, Glasvaenget 3-9, 5492 Vissenbjerg, Denmark | Instruction manual dated 15th January 2014, reference: UK 90583500 | Instruction manual dated 15th January 2014, reference: UK 90583500 | Wood logs[^f01000] |
| Scan Andersen 4-5 manufactured by Krog Iversen & Co. A/S DK-5492 Vissenbjerg, Denmark | The manufacturer’s instruction manual dated 15th November 2007 entitled “Scan Andersen 4-5”, reference: Edition 09/05-GB. A permanent stop must be in place on the secondary air inlet to prevent closure beyond 20 mm | The manufacturer’s instruction manual dated 15th November 2007 entitled “Scan Andersen 4-5”, reference: Edition 09/05-GB. A permanent stop must be in place on the secondary air inlet to prevent closure beyond 20 mm | Untreated dry wood |
| Scan Andersen 8-2 wood-burning 7kW stove manufactured by Jøtul A.S, P.O. Box 1411, N-1602 Fredrikstad, Norway | Installation and operating Instructions manual dated October 2012, reference: 10026402 -P01. Addendum to installation and operating instructions manual dated 5th June 2014, reference: SMOKEA8-2. Smoke control kit SMOKEA8-2 must be fitted to prevent closure of the air control beyond the 25% open position. | Installation and operating Instructions manual dated October 2012, reference: 10026402 -P01. Addendum to installation and operating instructions manual dated 5th June 2014, reference: SMOKEA8-2. Smoke control kit SMOKEA8-2 must be fitted to prevent closure of the air control beyond the 25% open position. | Wood logs[^f01000] |
| Scan DSA 7-5 wood-burning Inset roomheater manufactured by Scan A/S, Glasvaenget 3-9, 5492 Vissenbjerg, Denmark | Instruction manual entitled “Instructions for installation and use: SCAN DSA 6 & DSA 7-5”, reference: Edition 17.09.2010. Instruction manual entitled “DSA 7-5 – UK smoke control areas” dated 1 January 2012, reference: DSA 7-5 SMOKE. Instruction manual entitled “Instructions for installation (including directions for use and stoking)”, reference: Edition 05.10.2010 – GB. The appliance must be fitted with a mechanical stop to prevent closure of the air wash control lever beyond the 50% open position. | Instruction manual entitled “Instructions for installation and use: SCAN DSA 6 & DSA 7-5”, reference: Edition 17.09.2010. Instruction manual entitled “DSA 7-5 – UK smoke control areas” dated 1 January 2012, reference: DSA 7-5 SMOKE. Instruction manual entitled “Instructions for installation (including directions for use and stoking)”, reference: Edition 05.10.2010 – GB. The appliance must be fitted with a mechanical stop to prevent closure of the air wash control lever beyond the 50% open position. | Wood logs[^f01000] |
| Scan Ild 1 and 4 stoves manufactured by Scan A/S, Glasvaenget 3-9, 5492 Vissenbjerg, Denmark | Instruction manual dated February 2012, reference: 11.1c. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 83 mm open position. | Instruction manual dated February 2012, reference: 11.1c. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 83 mm open position. | Wood logs[^f01000] |
| Scan Ild 2 and 5 stoves manufactured by Scan A/S, Glasvaenget 3-9, 5492 Vissenbjerg, Denmark | Instruction manual dated February 2012, reference: 11-1d. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 83 mm open position. | Instruction manual dated February 2012, reference: 11-1d. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 83 mm open position. | Wood logs[^f01000] |
| Scan ILD 6 Insert stove manufactured by Scan A/S Glasvaenget 3-9, 5492 Vissenbjerg, Denmark | ILD 6 Insert stove instruction manual dated 25th February 2013, reference: 12-1b GB. The appliance must be fitted with a permanent stop preventing closure of the secondary air control beyond the 18% open position. | ILD 6 Insert stove instruction manual dated 25th February 2013, reference: 12-1b GB. The appliance must be fitted with a permanent stop preventing closure of the secondary air control beyond the 18% open position. | Wood logs[^f01000] |
| Scan ILD 7 and ILD 8 wood-burning stoves manufactured by Scan A/S Glasvaenget 3-9, 5492 Vissenbjerg, Denmark | Instruction manual dated 1st July 2013, reference: Manual version. No. 13-1 GB 01.07.13. The appliance must be fitted with a permanent stop to prevent secondary air control closure beyond the 7.5% open position. | Instruction manual dated 1st July 2013, reference: Manual version. No. 13-1 GB 01.07.13. The appliance must be fitted with a permanent stop to prevent secondary air control closure beyond the 7.5% open position. | Wood logs[^f01000] |
| Scan Warm 1 and 4 stoves manufactured by Scan A/S, Glasvaenget 3-9, 5492 Vissenbjerg, Denmark | Instruction manual dated February 2012, reference: 11-1a. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 83 mm open position. | Instruction manual dated February 2012, reference: 11-1a. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 83 mm open position. | Wood logs⁽¹⁾ |
| Scan Warm 2 and 5 stoves manufactured by Scan A/S, Glasvaenget 3-9, 5492 Vissenbjerg, Denmark | Instruction manual dated February 2012, reference: 11-1b. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 83 mm open position. | Instruction manual dated February 2012, reference: 11-1b. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 83 mm open position. | Wood logs[^f01000] |
| Scandian 5MF Traditional, Scandian 5MF Modern, Scandian 8MF Traditional and Scandian 8MF Modern multifuel stoves manufactured by Capital Fireplaces Limited, 12-17 Henlow Trading Estate, Henlow Camp, Hitchen, SG16 6DS | Installation and operating instruction manual dated June 2013, reference: Scandian MF&WD Version 1. The appliance must be fitted with the manufacturer’s smoke control kit. | Installation and operating instruction manual dated June 2013, reference: Scandian MF&WD Version 1. The appliance must be fitted with the manufacturer’s smoke control kit. | Wood logs[^f01000] |
| Scandian 5WD Traditional and Scandian 5WD Modern wood-burning stoves manufactured by Capital Fireplaces Limited, 12-17 Henlow Trading Estate, Henlow Camp, Hitchin, SG16 6DS | Installation and operating instruction manual dated June 2013, reference: Scandian MF&WD Version 1. | Installation and operating instruction manual dated June 2013, reference: Scandian MF&WD Version 1. | Wood logs[^f01000] |
| Scandian 8WD Traditional and Scandian 8WD Modern wood-burning stoves manufactured by Capital Fireplaces Limited, 12-17 Henlow Trading Estate, Henlow Camp, Hitchin, SG16 6DS | Installation and operating instruction manual dated June 2013, reference: Scandian MF&WD Version 1. The appliance must be fitted with the manufacturer’s smoke control kit. | Installation and operating instruction manual dated June 2013, reference: Scandian MF&WD Version 1. The appliance must be fitted with the manufacturer’s smoke control kit. | Wood logs[^f01000] |
| Schmid UTSK 180, 240, 300, 360, 450, 550, 700, 900, 1200, 1600 kw manufactured by Schmid AG Wood Firing Systems, PO Box 42, CH-8380, Eschlikon, Switzerland | Instruction manual dated 25th September 2008, reference: Instruction manual UTSK – ABC.22 – AME – S- PPU (where ABC is Model Number i.e. 180, 240, 300, 360, 450, 550, 700, 900, 1200, 1600) | Instruction manual dated 25th September 2008, reference: Instruction manual UTSK – ABC.22 – AME – S- PPU (where ABC is Model Number i.e. 180, 240, 300, 360, 450, 550, 700, 900, 1200, 1600) | Wood pellets or wood chips following CEN/TS 14961:2005[^f01000] |
| Schmid UTSL 30, 40, 50, 65, 80, 110, 150 kW manufactured by Schmid AG Wood Firing Systems, PO Box 42, CH-8380 Eschlikon, Switzerland | Instruction manual dated 23rd December 2004, reference: Operating Manual Wooden Chips and Pellets Plant. Lignumat UTSL | Instruction manual dated 23rd December 2004, reference: Operating Manual Wooden Chips and Pellets Plant. Lignumat UTSL | Wood pellets or wood chips following CEN/TS 14961:2005[^f01000] |
| Schmid UTSP 180, 240, 300 kW manufactured by Schmid AG, Wood Firing Systems, PO Box 42, CH-8380 Eschlikon, Switzerland | Instruction manual dated 25th September 2008, reference: Instruction manual UTSK – ABC.22 – AME – S- PPU (where ABC is Model Number i.e. 180, 240, 300) | Instruction manual dated 25th September 2008, reference: Instruction manual UTSK – ABC.22 – AME – S- PPU (where ABC is Model Number i.e. 180, 240, 300) | Wood pellets following CEN/TS 14961:2005[^f01000] |
| Schmid UTSR, 150, 180, 240, 300, 360, 450, 550, 700, 900 kW manufactured by Schmid AG, Wood Firing Systems, PO Box 42, CH-8380 Eschlikon, Switzerland | Instruction manual dated 25th September 2008, reference: Instruction manual UTSR – ABC.22 – AME – S-PPV (where ABC is Model Number i.e. 150, 180, 240, 300, 360, 450, 550, 700, 900) | Instruction manual dated 25th September 2008, reference: Instruction manual UTSR – ABC.22 – AME – S-PPV (where ABC is Model Number i.e. 150, 180, 240, 300, 360, 450, 550, 700, 900) | Wood pellets or wood chips following CEN/TS 14961:2005[^f01000] |
| Schmid UTSR 1200 manufactured by Schmid AG, Energy Solutions, Hörnlistrasse 12, Postfach 42, CH-8360 Eschlikon, Switzerland | Instruction manual for wood chip furnace with boiler type Schmid Pyrotronic Modular dated 24th April 2012, reference: 60110797.doc | Instruction manual for wood chip furnace with boiler type Schmid Pyrotronic Modular dated 24th April 2012, reference: 60110797.doc | Wood chips[^f01000] and wood pellets[^f01000] |
| Schmid UTSW 900.32 boiler manufactured by Schmid AG – woodfiring systems, Hörnlistrasse 12, CH-8360 Eschlikon, Switzerland | Instruction manual dated 7th January 2013, reference: Instruction manual. Wood chip furnace with boiler type Schmid Pyrotroinc Modular issue 1. Instruction manual dated 2010, reference: PersonalTouch Version 2010. EVO10V531\PT_2010_C3 | Instruction manual dated 7th January 2013, reference: Instruction manual. Wood chip furnace with boiler type Schmid Pyrotroinc Modular issue 1. Instruction manual dated 2010, reference: PersonalTouch Version 2010. EVO10V531\PT_2010_C3 | Wood chips and wood pellets[^f01000] |
| SE 60 Coalburner Stove manufactured by Jetmaster Fires Limited | Installation instructions, reference: SE60/1 8/84. Operating and maintenance instructions, reference: SE60/2 8/84. | Installation instructions, reference: SE60/1 8/84. Operating and maintenance instructions, reference: SE60/2 8/84. | Union Coal Bricketts, manufactured by Rheinbraun AG of Germany and comprising lignite compressed into briquettes of approximately 15 centimetres in length with square ends and with a sulphur content not exceeding 1% |
| Seguin Jade wood-burning stove manufactured by Groupe Seguin, Cheminees Seguin Duteriez, Zone Industrielle de Lhérat, 63310 France | Jade Instruction manual dated 1st January 2013, reference: WOOD STOVES MANUAL INSTALLATION – USE 1/1/2013 CHARACTERISTICS OF THE STOVE. The appliance must be fitted with a permanent stop to prevent closure of the secondary air control beyond the 40% open position. | Jade Instruction manual dated 1st January 2013, reference: WOOD STOVES MANUAL INSTALLATION – USE 1/1/2013 CHARACTERISTICS OF THE STOVE. The appliance must be fitted with a permanent stop to prevent closure of the secondary air control beyond the 40% open position. | Wood logs[^f01000] |
| Seguin Saphir wood-burning stove manufactured by Groupe Seguin, Cheminees Seguin Duteriez, Zone Industrielle de Lhérat, 63310 France | Saphir Instruction manual dated 1st January 2013, reference: WOOD STOVES MANUAL INSTALLATION – USE 1/1/2013 CHARACTERISTICS OF THE STOVE. The appliance must be fitted with a permanent stop to prevent closure of the secondary air control beyond the 15 mm open position. | Saphir Instruction manual dated 1st January 2013, reference: WOOD STOVES MANUAL INSTALLATION – USE 1/1/2013 CHARACTERISTICS OF THE STOVE. The appliance must be fitted with a permanent stop to prevent closure of the secondary air control beyond the 15 mm open position. | Wood logs[^f01000] |
| Senza UK w/o sideglass and Senza UK w/o sideglass 5kW wood-burning stoves manufactured by Jydepejsen A/S, Ahornsvinget 3-7, Nr Felding, DK-7500, Holstebro, Denmark | Instruction manual dated 27th November 2014, reference: User’s manual Revision 1, 27.11.2014. The appliance must be modified to fix the secondary air control to 1300mm² in its minimum position. | Instruction manual dated 27th November 2014, reference: User’s manual Revision 1, 27.11.2014. The appliance must be modified to fix the secondary air control to 1300mm² in its minimum position. | Wood logs[^f01000] |
| Serenity 40 FS, Serenity 40 LS, Serenity 40 FW stoves manufactured by Pevex Enterprises Ltd, Unit 16, Seven Acres, Waldringfield, Suffolk, IP12 4PS | Instruction manual dated January 2013, reference: Pevex1014/AH/ver1. The appliance must be fitted with permanent stops that ensure the secondary and tertiary air controls do not close beyond 1.1 cm open and 2 cm open positions respectively. | Instruction manual dated January 2013, reference: Pevex1014/AH/ver1. The appliance must be fitted with permanent stops that ensure the secondary and tertiary air controls do not close beyond 1.1 cm open and 2 cm open positions respectively. | Wood logs[^f01000] |
| Serenity 50FS, Serenity 50LS, Serenity 50FW and Serenity 50 Ped stoves manufactured by Pevex Enterprises Ltd, Unit 16 Seven Acres, Waldringfield, Suffolk, IP12 4PS | Instruction manual dated January 2013, reference: Pevex1014/AH/ver1. The secondary air slider must have a built-in stop to prevent the slider from shutting off completely and must remain open by at least 40% of its full travel. The tertiary air control must be factory designed with a 2 cm open slot that remains 100% open. | Instruction manual dated January 2013, reference: Pevex1014/AH/ver1. The secondary air slider must have a built-in stop to prevent the slider from shutting off completely and must remain open by at least 40% of its full travel. The tertiary air control must be factory designed with a 2 cm open slot that remains 100% open. | Wood logs[^f01000] |
| Serenity 50 Inset stove manufactured by Pevex Enterprises Ltd, Unit 16, Seven Acres, Waldringfield, Suffolk, IP12 4PS | Instruction manual dated January 2013, reference: Pevex1014/AH/ver1. The secondary air slider must have a built-in stop to prevent the slider from shutting off completely and must remain open by at least 40% of its full travel. The tertiary air control must be factory designed with a 2 cm open slot that remains 100% open. | Instruction manual dated January 2013, reference: Pevex1014/AH/ver1. The secondary air slider must have a built-in stop to prevent the slider from shutting off completely and must remain open by at least 40% of its full travel. The tertiary air control must be factory designed with a 2 cm open slot that remains 100% open. | Wood logs[^f01000] |
| Serrano 5 and Monterrey 6 Multi Fuel Stoves manufactured by Broseley Fires Ltd, First Floor, Unit B Knights Court, Archers Way, Battlefield Enterprise Park, Shrewsbury, Shropshire, SY1 3GA | Instruction manual dated 21st December 2009, reference: TJ09C. The appliance must be fitted with a system that prevents the closure of the secondary air flaps beyond the 8 mm open position. | Instruction manual dated 21st December 2009, reference: TJ09C. The appliance must be fitted with a system that prevents the closure of the secondary air flaps beyond the 8 mm open position. | Wood logs[^f01000] |
| Serrano 7 Multi Fuel Stove manufactured by Broseley Fires Ltd, First Floor, Unit B Knights Court, Archers Way, Battlefield Enterprise Park, Shrewsbury, Shropshire, SY1 3GA | Instruction manual dated 21st December 2009, reference: TJ09C. The appliance must be fitted with a system that prevents the closure of the secondary air flaps beyond the 10 mm open position. | Instruction manual dated 21st December 2009, reference: TJ09C. The appliance must be fitted with a system that prevents the closure of the secondary air flaps beyond the 10 mm open position. | Wood logs[^f01000] |
| Sherborne SE NS-3C, Chesham SE NS-3B and Burford SE NS-3A 4.9kW multi-fuel stoves manufactured by Newman Fireplaces Ltd Units 6 and 7 Rawreth Barns, Dollymans Farm, Doublegate Lane, Rawreth, Wickford, Essex, SS11 8UD | Installation and user instruction manual dated 4th June 2014, reference: NS-3A - NS-3B - NS-3C. The appliance must be fitted with mechanical stops to prevent closure of the secondary air control beyond the 30% open position and the tertiary air control beyond the 50% open position. | Installation and user instruction manual dated 4th June 2014, reference: NS-3A - NS-3B - NS-3C. The appliance must be fitted with mechanical stops to prevent closure of the secondary air control beyond the 30% open position and the tertiary air control beyond the 50% open position. | Wood logs[^f01000] |
| Short Penguin and Penguin 8 multifuel stoves manufactured by Chilli Penguin Stoves Limited, Castell Bach, Mynydd Nefyn, Pwllheli, LL53 6TL | Instruction manual dated 17th December 2013, reference: Penguin Manual Version 1 Issue 1. The appliance must be modified to prevent closure of the secondary air control beyond the 1 cm open position. | Instruction manual dated 17th December 2013, reference: Penguin Manual Version 1 Issue 1. The appliance must be modified to prevent closure of the secondary air control beyond the 1 cm open position. | Wood logs[^f01000] |
| SHT TDA Thermodual 15 and 25 log and pellet burning boilers manufactured by Lohberger Heiztechnik GmbH, Rechtes Salzachufer 40, A-5020, Salzburg, Austria | Installation servicing instructions dated January 2014, reference: In1233 Edition 1a. Operating instructions dated 28th January 2014, reference: Version M21/HB M27/GB. Supplementary installation instructions dated January 2014, reference: IN1241 Edition 1a. | Installation servicing instructions dated January 2014, reference: In1233 Edition 1a. Operating instructions dated 28th January 2014, reference: Version M21/HB M27/GB. Supplementary installation instructions dated January 2014, reference: IN1241 Edition 1a. | Wood logs or wood pellets[^f01000] |
| SHT TDA Thermodual 30 and 40 log and pellet burning boilers manufactured by Lohberger Heiztechnik GmbH, Rechtes Salzachufer 40, A-5020, Salzburg, Austria | Installation servicing instructions dated January 2014, reference: In2015 Edition 1. Operating instructions dated 28th January 2014, reference: Version M21/HB M27/GB. Supplementary installation instructions dated January 2014, reference: IN1241 Edition 1a | Installation servicing instructions dated January 2014, reference: In2015 Edition 1. Operating instructions dated 28th January 2014, reference: Version M21/HB M27/GB. Supplementary installation instructions dated January 2014, reference: IN1241 Edition 1a | Wood logs or wood pellets[^f01000] |
| Silent Glow Incinerator models CCD 450, 600 and 750, manufactured by Silent Glow Incinerators Limited | The manufacturer’s instructions dated May 1989 | The manufacturer’s instructions dated May 1989 | Solid waste of the types specified in the instructions dated May 1989 |
| Silverdale 5 SE, Amalia 5 and Oppdal 5 wood-burning stoves manufactured by Broseley Fires Ltd, First Floor, Unit B Knights Court, Archers Way, Battlefield Enterprise Park, Shrewsbury, SY1 3GA | Instruction manual dated February 2013, reference: GB12A Version 1. The appliance must be fitted with a permanent stop to prevent closure of the secondary air slider beyond the 23 mm open position. | Instruction manual dated February 2013, reference: GB12A Version 1. The appliance must be fitted with a permanent stop to prevent closure of the secondary air slider beyond the 23 mm open position. | Wood logs[^f01000] |
| Silverdale 5 SE, Amalia 5, Oppdal 5 and Hestia 5 nultifuel stoves manufactured by Broseley Fires Limited, First Floor, Unit B Knights Court, Archers Way, Battlefield Enterprise Park, Shrewsbury SY1 3GA | Instruction manual dated December 2014, reference: GB14A-issue5. The appliance must be fitted with a permanent stop to fix the secondary air slide at a minimum of 23mm open | Instruction manual dated December 2014, reference: GB14A-issue5. The appliance must be fitted with a permanent stop to fix the secondary air slide at a minimum of 23mm open | Wood logs[^f01000] |
| Silverdale 7 SE, Amalia 7 and Oppdal 7 wood-burning stoves manufactured by Broseley Fires Ltd, First Floor, Unit B Knights Court, Archers Way, Battlefield Enterprise Park, Shrewsbury, SY1 3GA | Instruction manual dated February 2013, reference: GB12A Version 1. The appliance must be fitted with a permanent stop to prevent closure of the secondary air slide beyond the 50 mm open position. | Instruction manual dated February 2013, reference: GB12A Version 1. The appliance must be fitted with a permanent stop to prevent closure of the secondary air slide beyond the 50 mm open position. | Wood logs[^f01000] |
| Silverdale 7 SE, Amalia 7, Oppdal 7 and Hestia 7 multi-fuel stoves manufactured by Broseley Fires Ltd, First Floor, Unit B Knights Court, Archers Way, Battlefield Enterprise Park, Shrewsbury, SY1 3GA | Instruction manual dated December 2014, reference: GB14A-issue5. The appliance must be fitted with a permanent stop to fix the secondary air slide at a minimum of 50mm open. | Instruction manual dated December 2014, reference: GB14A-issue5. The appliance must be fitted with a permanent stop to fix the secondary air slide at a minimum of 50mm open. | Wood logs[^f01000] |
| Sirius 450 – see Micromet MEG 4.5 and MEG 4.5 stove | |||
| Sirius 490 Sigma MF, Sirius 490 Scene MF, Sirius 790 Sigma MF and Sirius 790 Scene MF multifuel stoves manufactured by Capital Fireplaces Limited, 12-17 Henlow Trading Estate, Henlow Camp, Hitchin, SG16 6DS | Installation and Operating Instructions manual dated May 2013, reference: Sirius MF&WD Version 1. The appliance must be fitted with the manufacturer’s smoke control kit. | Installation and Operating Instructions manual dated May 2013, reference: Sirius MF&WD Version 1. The appliance must be fitted with the manufacturer’s smoke control kit. | Wood logs[^f01000] |
| Sirius 490 Sigma WD and Sirius 490 Scene WD wood-burning stoves manufactured by Capital Fireplaces Limited, 12-17 Henlow Trading Estate, Henlow Camp, Hitchin, SG16 6DS | Installation and operating instruction manual dated May 2013, reference: Sirius MF&WD Version 1 | Installation and operating instruction manual dated May 2013, reference: Sirius MF&WD Version 1 | Wood logs[^f01000] |
| Sirius 750 – see Micromet MEG 7.5 and MEG 7.5 stove | |||
| Sirius 790 Sigma WD and Sirius 790 Scene WD wood-burning stoves manufactured by Capital Fireplaces Limited, 12-17 Henlow Trading Estate, Henlow Camp, Hitchin, SG16 6DS | Installation and operating instructions manual dated May 2013, reference: Sirius MF&WD Version 1. The appliance must be fitted with the manufacturer’s smoke control kit. | Installation and operating instructions manual dated May 2013, reference: Sirius MF&WD Version 1. The appliance must be fitted with the manufacturer’s smoke control kit. | Wood logs[^f01000] |
| Sirius Traditional Stove manufactured by Tianjin Focus Arts & Crafts Co, Industrial Area Gao Zhuangzi Village, Xin Zhuang Town, Jin Nan District, Tianjin, P.R. China 300350 | Instruction and operating instruction manual dated 9th November 2010, reference: v173 of 09/11/2010 | Instruction and operating instruction manual dated 9th November 2010, reference: v173 of 09/11/2010 | Wood logs[^f01000] |
| Smart 150, Smart 199, Smart 250, Smart 300, Smart 350, Smart 400, Smart 450 and Smart 500 boilers all fitted with cyclones manufactured by Smart Heating Technology s.r.o, U Statku 653/24, 717 00 Ostrava-Bartovice, Czech Republic | Operation Manual for Boilers Smart 150-500kW dated January 2014, reference: BO4CD35 Issue No: 02 | Operation Manual for Boilers Smart 150-500kW dated January 2014, reference: BO4CD35 Issue No: 02 | 6mm wood pellets or 30mm wood chips, which have moisture content not exceeding 30% of the total weight[^f01000] |
| Solid Fuel Ductair Unit manufactured by Radiation Limited | The manufacturer’s instructions as to operation (if any) | The manufacturer’s instructions as to operation (if any) | Any fuel specified in the manufacturer’s instructions |
| Spacewarmer B200 manufactured by Clearair Limited | In relation to an appliance purchased before 31st December 1990, the manufacturer’s instructions, reference: B200/DEC ’83. In relation to an appliance purchased on or after 31st December 1990, the manufacturer’s instructions, reference: B200/DEC ’83 and the additional condition that the appliance must not be used to burn chipboard unless an afterburner, supplied by the manufacturer and capable of producing 50 megajoules of heat per hour, has been fitted to the appliance. | In relation to an appliance purchased before 31st December 1990, the manufacturer’s instructions, reference: B200/DEC ’83. In relation to an appliance purchased on or after 31st December 1990, the manufacturer’s instructions, reference: B200/DEC ’83 and the additional condition that the appliance must not be used to burn chipboard unless an afterburner, supplied by the manufacturer and capable of producing 50 megajoules of heat per hour, has been fitted to the appliance. | In relation to an appliance purchased before 31st December 1990, any fuel specified in the manufacturer’s instructions, reference: B200/DEC ’83. In relation to an appliance purchased on or after 31st December 1990, hardwood offcuts, softwood offcuts, or a mixture of offcuts (hardwood or softwood) and sawdust with no more than 50% of the mixture being sawdust or chipboard offcuts[^f01000] |
| Spacewarmer B500 manufactured by Clearair Limited | The manufacturer’s instructions, reference: B500/DEC ‘83 | The manufacturer’s instructions, reference: B500/DEC ‘83 | In relation to an appliance purchased before 31st December 1990, any fuel specified in the manufacturer’s instructions, reference: B500/DEC ’83. In relation to an appliance purchased on or after 31st December 1990, hardwood or softwood offcuts[^f01000] |
| Spänex Wood Fired Air Heater (types UL50, UL75 and UL100 only) manufactured by Spänex Sander GmbH Co KG, Volpriehausen, Solling, Federal Republic of Germany | The manufacturer’s instructions dated May 1978, Issue No.1 | The manufacturer’s instructions dated May 1978, Issue No.1 | Wood waste containing not more than 5% sander dust[^f01000] |
| Spartherm Arte U-50h – P3, Spartherm Arte U-90h – P3 and Spartherm Arte U-70h – P3 insert stoves manufactured by Spartherm Feuerungstechnik GmbH, Maschweg 38, D-49324 Melle, Germany | Instruction manual Fireplace Inserts dated June 2014, reference: Version 06/2014 | Instruction manual Fireplace Inserts dated June 2014, reference: Version 06/2014 | Wood logs[^f01000] |
| Spartherm Linear cassette model S 600 P3 inset stove manufactured by Spartherm Feuerungstechnik GmbH, Maschweg 38, D-49324 Melle, Germany | Installation and Operating Instructions Linear Fireplace Cassettes dated January 2014, reference: Spartherm_AA_BA_Kaminkassette_Linear_GB_Stand 01-2014. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air controls beyond the 25% open position. | Installation and Operating Instructions Linear Fireplace Cassettes dated January 2014, reference: Spartherm_AA_BA_Kaminkassette_Linear_GB_Stand 01-2014. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air controls beyond the 25% open position. | Wood logs[^f01000] |
| Spartherm Linear Cassette XS500 –P3 insert stove manufactured by Spartherm Feuerungstechnik GmbH, Maschweg 38, D-49324 Melle, Germany | Instruction manual Fireplace Inserts dated June 2014, reference: Version 06/2014 | Instruction manual Fireplace Inserts dated June 2014, reference: Version 06/2014 | Wood logs[^f01000] |
| Spartherm Mini 2LRh-4S P3, Spartherm Mini 2L-4S P3, and Spartherm Mini 2R-4S P3 wood-burning inset roomheaters manufactured by Spartherm Feuerungstechnik GmbH, Maschweg 38, S-49324 Melle, Germany | Instruction manual dated June 2014, reference: Instruction Manual Fireplace Inserts Version 06/2014. A system to prevent closure of the air controls beyond the 3 mm open position must be implemented. | Instruction manual dated June 2014, reference: Instruction Manual Fireplace Inserts Version 06/2014. A system to prevent closure of the air controls beyond the 3 mm open position must be implemented. | Wood logs[^f01000] |
| Spartherm Stovo S, M and L Wood burning stoves manufactured by Spartherm Feuerungstechnik GmbH, Maschweg 38, D-49324 Melle, Germany | Installation and operating instructions dated July 2012, reference: Version 07/2013. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 13% open position. | Installation and operating instructions dated July 2012, reference: Version 07/2013. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 13% open position. | Wood logs[^f01000] |
| Spartherm Varia ASh2L – P3, Spartherm Varia ASh2R – P3, Spartherm Varia ASh2L X – P3, and Spartherm Varia ASh2R X – P3 wood-burning inset roomheaters manufactured by Spartherm Feuerungstechnik GmbH, Maschweg 38, D-49324 Melle, Germany | Instruction manual dated June 2014, reference: Instruction Manual Fireplace Inserts Version 06/2014. A system to prevent closure of the air controls beyond the 7 mm open position must be implemented. | Instruction manual dated June 2014, reference: Instruction Manual Fireplace Inserts Version 06/2014. A system to prevent closure of the air controls beyond the 7 mm open position must be implemented. | Wood logs[^f01000] |
| SP Dual 15kW boiler, SP Dual 22kW boiler, SP Dual 28kW boiler, SP Dual 34kW boiler and SP Dual 40kW boiler manufactured by Fröhling Heizkessel und Behälterbau GmbH, Industriestraße 12, A–4710 Grieskirchen, Austria | Dual fuel Boiler SP Dual operating instructions dated 9th October 2012, reference: B0760212_en Edition 09/10/2012 | Dual fuel Boiler SP Dual operating instructions dated 9th October 2012, reference: B0760212_en Edition 09/10/2012 | Wood logs or wood pellets[^f01000] |
| Stockton 3 Flat top (product code 7118), Stockton 4 Flat top (product code 7101 and 7102), Stockton 5 Flat top (product code 7127) Stockton 5 midline (product code 7130), Stockton 6 Flat top (product codes 7100 and 7162), Stockton 6 Highline (product code 7117) and Stockton 7 Flat top (product codes 7120 and 7163) manufactured by Stovax Limited, Falcon Road, Sowton Industrial Estate, Exeter, Devon, EX2 7LF | The manufacturer’s instruction manual dated July 2008, reference: PM227 ENG Issue 2. The manufacturer’s instruction manual dated January 2009, reference: PM271 Issue 2. A permanent stop must be in place on the secondary air inlet to prevent closure beyond the 50% open position. | The manufacturer’s instruction manual dated July 2008, reference: PM227 ENG Issue 2. The manufacturer’s instruction manual dated January 2009, reference: PM271 Issue 2. A permanent stop must be in place on the secondary air inlet to prevent closure beyond the 50% open position. | Untreated dry wood |
| Stockton 5 Flat top (model number 7119), Stockton 5 Canopy (model number 7160) and Stockton 5 Midline (model number 7133) manufactured by Stovax Limited, Falcon Road, Sowton Industrial Estate, Exeter, Devon, EX2 7LF | The manufacturer’s instruction manual reference: PM 176 – Issue 4. A permanent stop must be in place on the secondary air inlet to prevent closure beyond the 50% open position. | The manufacturer’s instruction manual reference: PM 176 – Issue 4. A permanent stop must be in place on the secondary air inlet to prevent closure beyond the 50% open position. | Untreated dry wood |
| Stockton 7 Inset Convector (product codes 7125F and 7125C) manufactured by Stovax Limited, Falcon Road, Sowton Industrial Estate, Exeter, Devon, EX2 7LF | Manufacturer’s instruction manual dated May 2008, reference: PM230 Issue 1. Instruction manual dated January 2009, reference: PM281 Issue 1 | Manufacturer’s instruction manual dated May 2008, reference: PM230 Issue 1. Instruction manual dated January 2009, reference: PM281 Issue 1 | Untreated dry wood |
| Stockton 7 Inset Convector (product codes 7125F and 7125C) manufactured by Stovax Limited, Falcon Road, Sowton Industrial Estate, Exeter, Devon, EX2 7LF | A permanent stop must be in place on the secondary air inlet to prevent closure beyond the 50% open position | A permanent stop must be in place on the secondary air inlet to prevent closure beyond the 50% open position | Untreated dry wood |
| Stockton Milner (4.6 kW) inset stove – smoke control version - manufactured by Stovax Limited, Falcon Road, Sowton Industrial Estate, Exeter, Devon, EX2 7LF | Instruction manual reference: PM416 Issue 1 (June 2010). Smoke control kit instruction manual reference: PM501 Issue 1 (June 2010). A permanent stop must be positioned to prevent closure of the secondary air control below the 50% open position. | Instruction manual reference: PM416 Issue 1 (June 2010). Smoke control kit instruction manual reference: PM501 Issue 1 (June 2010). A permanent stop must be positioned to prevent closure of the secondary air control below the 50% open position. | Wood logs[^f01000] |
| Stoven Mayfair SE and Stoven Kensington SE 5kW Wood Burning Stoves manufactured by Newman Fireplaces, Ltd, Units 6 and 7 Rawreth Barns, Dollymans Farm, Doublegate Lane, Rawreth, Wickford, Essex, SS11 8UD | Newman Fireplaces Limited’s Instruction manual dated 27th November 2011, reference: 3-4. The appliance must be fitted with mechanical stops to prevent closure of the secondary air control beyond the 25% open position and the tertiary air beyond the 1 mm open position. | Newman Fireplaces Limited’s Instruction manual dated 27th November 2011, reference: 3-4. The appliance must be fitted with mechanical stops to prevent closure of the secondary air control beyond the 25% open position and the tertiary air beyond the 1 mm open position. | Wood logs[^f01000] |
| Strebel Biotec 25 and 40 boilers manufactured by Topling d.o.o, Magistralni put BB, 78430 Prnjavor, The Republic of Srpska, Bosnia and Herzegovina | Instruction manual dated December 2013, reference: Version BIOTEC122013 | Instruction manual dated December 2013, reference: Version BIOTEC122013 | Wood pellets[^f01000] |
| Strebel SRP TR 90, 90 kW output pellet boiler manufactured by FIRE FOX Bioheizsysteme GmbH, Eisenstraße 54, 9330 Althofen, 1 Austria | The Strebel SRP TR 90 pellet boiler installation manual reference: “Installation and operation instructions for special pellet-furnace” version 09:2010. | The Strebel SRP TR 90 pellet boiler installation manual reference: “Installation and operation instructions for special pellet-furnace” version 09:2010. | 6mm diameter wood pellets[^f01000] |
| Strebel Taurus XL145, Strebel Taurus XL190, Strebel Taurus XL240 and Strebel Taurus XL290 boilers manufactured by KSM Stoker, Næssundvej 440 7960 Karby, Denmark | Instruction manual dated December 2013, reference: Manual Version XL145 to 290 | Instruction manual dated December 2013, reference: Manual Version XL145 to 290 | Wood pellets or wood chips[^f01000] |
| Stretton Insert Smoke Exempt Wood Fuel Stove (Stretton Stove SE) manufactured by Aga Station Road, Ketley Telford, Shropshire, TF1 5AQ | Instruction manual dated 12th July 2011, reference: N00530AXX REV:001 | Instruction manual dated 12th July 2011, reference: N00530AXX REV:001 | Dry wood logs[^f01000] |
| Stuv 30 Compact H stove manufactured by Stuv Sa, Rue Jules Borbouse 4, B-5170, Bois-de-Villers, Belgium | Instruction manual dated January 2013, reference: SN 131766. Installation instruction manual dated January 2013, reference: SN 131766. The appliance must be fitted with a mechanical stop to prevent air control closure beyond the positions between settings 3 and 4. | Instruction manual dated January 2013, reference: SN 131766. Installation instruction manual dated January 2013, reference: SN 131766. The appliance must be fitted with a mechanical stop to prevent air control closure beyond the positions between settings 3 and 4. | Wood logs[^f01000] |
| Stuv 30 Compact IN and Stuv 30 Compact R stoves manufactured by Stuv Sa, Rue Jules Borbouse 4, B-5170, Bois-de-Villers, Belgium | Instruction manual dated January 2013, reference: SN112787. Installation instruction manual dated January 2013, reference: 112787. The appliance must be fitted with a mechanical stop to prevent air control closure beyond the positions between settings 3 and 4. | Instruction manual dated January 2013, reference: SN112787. Installation instruction manual dated January 2013, reference: 112787. The appliance must be fitted with a mechanical stop to prevent air control closure beyond the positions between settings 3 and 4. | Wood logs[^f01000] |
| Stuv 30 Compact stove manufactured by Stuv Sa, Rue Jules Borbouse 4, B-5170, Bois-de-Villers, Belgium | Instruction manual dated January 2013, reference: SN 94770. Installation instruction manual dated January 2013, reference: SN 94770. The appliance must be fitted with a mechanical stop to prevent air control closure beyond the positions between settings 3 and 4. | Instruction manual dated January 2013, reference: SN 94770. Installation instruction manual dated January 2013, reference: SN 94770. The appliance must be fitted with a mechanical stop to prevent air control closure beyond the positions between settings 3 and 4. | Wood logs[^f01000] |
| Suprema, Mamy and Italy Hard Top manufactured by La Nordica S.p.A., Via Summano, 104 – 36030, Montecchio Precalcino, Vicenza, Italy | Instruction manual dated 13th December 2010, reference: 7095701 Rev.09 | Instruction manual dated 13th December 2010, reference: 7095701 Rev.09 | Wood logs[^f01000] |
| Talbott 150-CMH 150 kW output Biomass Air Heater manufactured by Talbott’s Biomass Energy Systems Ltd, Tollgate Drive, Tollgate Industrial Estate, Stafford ST16 3HS | Instruction manual for Talbott 150-CMH hand-fed Biomass Air Heater operating package dated January 2011, reference: OM-150-CMH version 1 | Instruction manual for Talbott 150-CMH hand-fed Biomass Air Heater operating package dated January 2011, reference: OM-150-CMH version 1 | Softwood, hardwood, medium density fibreboard (MDF) or chipboard offcuts[^f01000] |
Reading this document does not replace reading the official text published on legislation.gov.uk. Contains public sector information licensed under the Open Government Licence v3.0. We assume no responsibility for any inaccuracies arising from the conversion of the original CLML XML to this format.
This text is published under legislation.gov.uk's own terms of reuse, not a Legalize or public-domain licence.
legislation.gov.uk
Open Government Licence v3.0 (attribution required)
© Crown and database right. Derived from content available under the Open Government Licence v3.0 from legislation.gov.uk.