The Smoke Control Areas (Exempted Fireplaces) (England) Order 2015

Type Statutory-Instrument
Publication 2015-02-16
State In force
Department King's Printer of Acts of Parliament
PDF Download
articles Not indexed
Reform history JSON API
Fireplace Conditions Conditions Conditions
Camelot 4 stove manufactured by Hunter Stoves Ltd, Trevilla Park, Slaughterbridge, Camelford, Cornwall, PL32 9TT Instruction manual dated 24th April 2012, reference: JINCAM04 Rev B. The appliance must be fitted with a permanent stop that prevents closure of the secondary air slider beyond 30% open. Instruction manual dated 24th April 2012, reference: JINCAM04 Rev B. The appliance must be fitted with a permanent stop that prevents closure of the secondary air slider beyond 30% open. Wood logs[^f01000]
Camelot 5 Compact stove manufactured by Hunter Stoves Ltd, Trevilla Park, Slaughterbridge, Camelford, Cornwall, PL32 9TT Instruction manual dated 14th June 2012, reference: JINCAC05 Rev B. The appliance must be fitted with a permanent stop that prevents closure of the secondary air slider beyond 30% open. Instruction manual dated 14th June 2012, reference: JINCAC05 Rev B. The appliance must be fitted with a permanent stop that prevents closure of the secondary air slider beyond 30% open. Wood logs[^f01000]
Camelot 5 slimline stove manufactured by Hunter Stoves Ltd, Trevilla Park, Slaughterbridge, Camelford, Cornwall, PL32 9TT Instruction manual dated 15th June 2012, reference: JINCAS05 Rev B Instruction manual dated 15th June 2012, reference: JINCAS05 Rev B Wood logs[^f01000]
Camelot 6 stove manufactured by Hunter Stoves Ltd, Trevilla Park, Slaughterbridge, Camelford, Cornwall, PL32 9TT Instruction manual dated 24th April 2012, reference: JINCAM06 Rev B Instruction manual dated 24th April 2012, reference: JINCAM06 Rev B Wood logs[^f01000]
Camelot slimline 8 stove manufactured by Hunter Stoves Ltd, Trevilla Park, Slaughterbridge, Camelford, Cornwall, PL32 9TT Instruction manual dated 27th June 2012, reference: JINCAS08 Rev B Instruction manual dated 27th June 2012, reference: JINCAS08 Rev B Wood logs[^f01000]
Carillon 16:9 Crystal manufactured by La Nordica S.p.A., Via Summano, 104 – 36030, Montecchio Precalcino, Vicenza, Italy Instruction manual dated 22nd December 2010, reference: 7196755-Rev 09. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 40% open position. Instruction manual dated 22nd December 2010, reference: 7196755-Rev 09. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 40% open position. Wood logs[^f01000]
Carillon 4:3 manufactured by La Nordica S.p.A., Via Summano, 104 – 36030, Montecchio Precalcino, Vicenza, Italy Instruction manual dated 22nd December 2010, reference: 7196755-Rev 09. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 40% open position. Instruction manual dated 22nd December 2010, reference: 7196755-Rev 09. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 40% open position. Wood logs[^f01000]
Carron 11 kW SE Stove manufactured by JIG UK Ltd, Hurlingham Business Park, Fulbeck Heath, Grantham, Lincolnshire, NG32 3HL Instruction manual reference: Carron 11 kW Stove model September 2012 (Smoke Exempt). A modification to the secondary air control preventing closure beyond 4 mm open must be implemented. Instruction manual reference: Carron 11 kW Stove model September 2012 (Smoke Exempt). A modification to the secondary air control preventing closure beyond 4 mm open must be implemented. Wood logs[^f01000]
Carron Dante SE manufactured by Jig UK Limited, Hurlingham Business Park, Fulbeck Heath, Grantham, Lincolnshire, NG32 3HL Instruction manual dated 12th January 2011, reference: BHC401-406. The appliance must be fitted with a system preventing the closure of the secondary air control openings beyond 14 mm. Instruction manual dated 12th January 2011, reference: BHC401-406. The appliance must be fitted with a system preventing the closure of the secondary air control openings beyond 14 mm. Wood logs[^f01000]
Carron Stove manufactured by Jig UK Limited, Hurlingham Business Park, Fulbeck Heath, Grantham, Lincolnshire, NG32 3HL Instruction manual dated July 2009, reference: 91-62351 Instruction manual dated July 2009, reference: 91-62351 Dry and split wood logs of a maximum length of 23 cm[^f01000]
Carron Stove SE manufactured by Jig UK Limited Hurlingham Business Park, Fulbeck Heath, Grantham, Lincolnshire, NG32 3HL Instruction manual dated 12th January 2011, reference: BHC501-506. The appliance must be fitted with a system preventing the closure of the secondary air control openings beyond 3 mm. Instruction manual dated 12th January 2011, reference: BHC501-506. The appliance must be fitted with a system preventing the closure of the secondary air control openings beyond 3 mm. Wood logs[^f01000]
Cast Tec Arbeia Juno freestanding wood-burning stove manufactured by Charlton & Jenrick Limited, Unit D Stafford Park 2, Telford, Shropshire, TF3 3AR Installation and operating instructions dated June 2013, reference: Juno & Vulcan Issue 01. The appliance must be fitted with a system that prevents closure of the secondary air control slots beyond the 7 mm open position. Installation and operating instructions dated June 2013, reference: Juno & Vulcan Issue 01. The appliance must be fitted with a system that prevents closure of the secondary air control slots beyond the 7 mm open position. Wood logs[^f01000]
Cast Tec Arbeia Titus wood-burning inset stove manufactured by Charlton & Jenrick Limited, Unit D Stafford Park 2, Telford, Shropshire, TF3 3AR Installation and operating instructions dated June 2013, reference: Trajan & Titus Issue 01. The appliance must be fitted with a system that prevents closure of the secondary air control slots beyond the 9 mm open position. Installation and operating instructions dated June 2013, reference: Trajan & Titus Issue 01. The appliance must be fitted with a system that prevents closure of the secondary air control slots beyond the 9 mm open position. Wood logs[^f01000]
Cast Tec Arbeia Trajan wood-burning Inset Stove manufactured by Charlton & Jenrick Limited, Unit D Stafford Park 2, Telford, Shropshire, TF3 3AR Installation and operating instructions dated June 2013, reference: Trajan & Titus Issue 01. The appliance must be fitted with a system that prevents closure of the secondary air control slots beyond the 3.5 mm open position. Installation and operating instructions dated June 2013, reference: Trajan & Titus Issue 01. The appliance must be fitted with a system that prevents closure of the secondary air control slots beyond the 3.5 mm open position. Wood logs[^f01000]
Cast Tec Arbeia Vulcan freestanding wood-burning stove manufactured by Charlton & Jenrick Limited, Unit D Stafford Park 2, Telford, Shropshire, TF3 3AR Installation and operating instructions dated June 2013, reference: Juno & Vulcan Issue 01. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 5 mm open position. Installation and operating instructions dated June 2013, reference: Juno & Vulcan Issue 01. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 5 mm open position. Wood logs[^f01000]
Cast Tec Cougar 4.7kW multi-fuel stove manufactured by Arbeia Trading Ltd, Unit 3A East Side, Tyne Dock, South Shields, Tyne And Wear, NE33 5SP Instruction manual dated 22nd April 2014, reference: T1202 v 1. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 25% open position. The appliance must be fitted with a mechanical stop to fix the tertiary air control in the fully open position. Instruction manual dated 22nd April 2014, reference: T1202 v 1. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 25% open position. The appliance must be fitted with a mechanical stop to fix the tertiary air control in the fully open position. Wood logs[^f01000]
CB800 Skagen manufactured by Hunter Stoves Limited, Trevilla Park, Slaughterbridge, Camelford, Cornwall, PL32 9TT Instruction manual dated 6th December 2011, reference: JINHCE08 rev E. Instruction manual dated 6th December 2011, reference: JINHCE08SCK rev B. The appliance must be fitted with smoke control area kit JHCE080. Instruction manual dated 6th December 2011, reference: JINHCE08 rev E. Instruction manual dated 6th December 2011, reference: JINHCE08SCK rev B. The appliance must be fitted with smoke control area kit JHCE080. Wood logs[^f01000]
CBR Flexifuel Heater, models 150 and 200 manufactured by CBR Fabrications Limited The manufacturer’s instructions, reference: FF/CBR Flexifuel 150/200 1989. The appliance must not be used to burn sawdust in bulk. The manufacturer’s instructions, reference: FF/CBR Flexifuel 150/200 1989. The appliance must not be used to burn sawdust in bulk. Hardwood offcuts, softwood offcuts or chipboard[^f01000]
CBR Flexifuel Heater, models 300, 400 and 600, manufactured by CBR Fabrications Limited The manufacturer’s instructions, reference: FF/CBR Flexifuel 87. The appliance must not be used to burn sawdust in bulk. The manufacturer’s instructions, reference: FF/CBR Flexifuel 87. The appliance must not be used to burn sawdust in bulk. Hardwood offcuts, softwood offcuts or chipboard[^f01000]
CBR Turbo Heat, models 200, 300, 400, 500, 600 and 800 manufactured by CBR Fabrications Limited The manufacturer’s instructions, reference FF/CBR Turbo Heat 88. The appliance must not be used to burn sawdust in bulk. The manufacturer’s instructions, reference FF/CBR Turbo Heat 88. The appliance must not be used to burn sawdust in bulk. Hardwood offcuts, softwood offcuts or chipboard[^f01000]
Charnwood Bay 5 wood burning inset stove manufactured by A.J. Wells and Sons Limited, Bishops Way, Newport, Isle of Wight, PO30 5WS Charnwood Bay 5 Operating & Installation Instructions dated January 2014, reference: BAY 5 v3 Charnwood Bay 5 Operating & Installation Instructions dated January 2014, reference: BAY 5 v3 Wood logs[^f01000]
Charnwood Bay 5GT 5.8kW wood burning inset stove manufactured by A.J. Wells and Sons Limited, Bishops Way, Newport, Isle of Wight, PO30 5WS Charnwood Bay 5 Operating & Installation Instructions dated April 2014, reference: Bay 5,5GT v3. Charnwood Bay 5 Operating & Installation Instructions dated April 2014, reference: Bay 5,5GT v3. Wood logs[^f01000]
Charnwood C-Eight Wood Burning Stove manufactured by A.J. Wells and Sons Limited, Bishops Way, Newport, Isle of Wight, PO30 5WS Instruction manual dated September 2012, reference: C-series v2. The appliance must be fitted with a mechanical stop to prevent air control opening closure beyond the 64 mm open position. Instruction manual dated September 2012, reference: C-series v2. The appliance must be fitted with a mechanical stop to prevent air control opening closure beyond the 64 mm open position. Wood logs[^f01000]
Charnwood C-Five Wood Burning Stove manufactured by A.J. Wells and Sons Limited, Bishops Way, Newport, Isle of Wight, PO30 5WS Instruction manual dated September 2012, reference: C-series v2. The appliance must be fitted with a mechanical stop to prevent air control opening closure beyond the 58 mm open position. Instruction manual dated September 2012, reference: C-series v2. The appliance must be fitted with a mechanical stop to prevent air control opening closure beyond the 58 mm open position. Wood logs[^f01000]
Charnwood C-Four stove manufactured by A.J Wells & Sons Ltd, Bishops Way, Newport, Isle of Wight, PO30 5WS Instruction manual dated August 2011, reference: CFOUR V1 Instruction manual dated August 2011, reference: CFOUR V1 Wood logs[^f01000]
Charnwood Country 4 wood burning stove manufactured by AJ Wells and Sons, Bishops Way, Newport, Isle of Wight, PO30 5WS Modification instruction manual dated January 2011, reference: TIS.95. Instruction manual dated January 2011, reference: Country 4 MKII. The appliance must be fitted with the manufacturer’s smoke reduction kit when used within a smoke control area to fix the minimum aperture of the secondary air inlets to a minimum of 21 mm open. Modification instruction manual dated January 2011, reference: TIS.95. Instruction manual dated January 2011, reference: Country 4 MKII. The appliance must be fitted with the manufacturer’s smoke reduction kit when used within a smoke control area to fix the minimum aperture of the secondary air inlets to a minimum of 21 mm open. Wood logs[^f01000]
Charnwood Cove 1SR stove manufactured by A.J. Wells and Sons Ltd, Bishops Way, Newport, Isle of Wight, PO30 5WS Installation and use instruction manual reference: COVE1SR01.10 Issue A. An adjustment of the air control such that the minimum closure of the air control is equivalent to that found with the control pushed in 15 mm from the fully open position must be made. Installation and use instruction manual reference: COVE1SR01.10 Issue A. An adjustment of the air control such that the minimum closure of the air control is equivalent to that found with the control pushed in 15 mm from the fully open position must be made. Wood logs[^f01000]
Charnwood C-Seven Wood Burning Stove manufactured by A.J. Wells and Sons Limited, Bishops Way, Newport, Isle of Wight, PO30 5WS Instruction manual dated September 2012, reference: C-series v2. The appliance must be fitted with a mechanical stop to prevent air control opening closure beyond 64 mm open position. Instruction manual dated September 2012, reference: C-series v2. The appliance must be fitted with a mechanical stop to prevent air control opening closure beyond 64 mm open position. Wood logs[^f01000]
Charnwood C-Six stove manufactured by A.J. Wells & Sons Ltd, Bishops Way, Newport, Isle of Wight, PO30 5WS Instruction manual dated March 2012, reference: Ref. C-4 C-6 v1. The fitting of a system that prevents the closure of the air control opening beyond 58 mm of the open position must be implemented. Instruction manual dated March 2012, reference: Ref. C-4 C-6 v1. The fitting of a system that prevents the closure of the air control opening beyond 58 mm of the open position must be implemented. Wood logs[^f01000]
Charnwood Island 1 stove manufactured by AJ Wells and Sons, Bishops Way, Newport, Isle of Wight, PO30 5WS Instruction manual dated December 2010, reference: Island I.II.III 12.10 Issue B. The appliance must be fitted with a stop bracket (kit no. 010/AY83/S) to prevent the airwash flaps at the back of the stove from being closed beyond 2 mm. Instruction manual dated December 2010, reference: Island I.II.III 12.10 Issue B. The appliance must be fitted with a stop bracket (kit no. 010/AY83/S) to prevent the airwash flaps at the back of the stove from being closed beyond 2 mm. Wood logs[^f01000]
Charnwood Island 2 stove manufactured by AJ Wells and Sons, Bishops Way, Newport, Isle of Wight, PO30 5WS Instruction manual dated December 2010, reference: Island I.II.III 12.10 Issue B. The appliance must be fitted with a stop bracket (kit no. 010/BY83/S) to prevent the airwash flaps at the back of the stove from being closed beyond 2 mm. Instruction manual dated December 2010, reference: Island I.II.III 12.10 Issue B. The appliance must be fitted with a stop bracket (kit no. 010/BY83/S) to prevent the airwash flaps at the back of the stove from being closed beyond 2 mm. Wood logs[^f01000]
Charnwood Island 3 stove manufactured by AJ Wells and Sons, Bishops Way, Newport, Isle of Wight, PO30 5WS Instruction manual dated December 2010, reference: Island I.II.III 12.10 Issue B. The appliance must be fitted with a stop bracket (kit no. 010/CY83/S) to prevent the airwash flaps at the back of the stove from being closed beyond 2 mm. Instruction manual dated December 2010, reference: Island I.II.III 12.10 Issue B. The appliance must be fitted with a stop bracket (kit no. 010/CY83/S) to prevent the airwash flaps at the back of the stove from being closed beyond 2 mm. Wood logs[^f01000]
Charnwood Tor Pico stove manufactured by AJ Wells and Son Ltd, Bishops Way, Newport, Isle of Wight, PO30 5WS Instruction manual dated December 2010, reference: Tor and Tor Pico 12.10 Issue B Instruction manual dated December 2010, reference: Tor and Tor Pico 12.10 Issue B Wood logs[^f01000]
Charnwood Tor stove manufactured by A.J Wells and Sons Ltd, Bishops Way, Newport, Isle of Wight, PO30 5WS Installation and Use Instruction manual reference: Tor 02.10 Issue A Installation and Use Instruction manual reference: Tor 02.10 Issue A Wood logs[^f01000]
Chelsea SE 4.7kW multifuel inset roomheater manufactured by Newman Fireplaces Ltd, Units 6 and 7 Rawreth Barns, Dollymans Farm, Doublegate Lane, Rawreth, Wickford, Essex, SS11 8UD Installation and user instructions manual dated 8th January 2014, reference: NS-4. Issue 1. The appliance must be fitted with a permanent stop to prevent closure of the secondary air supply control beyond the 7 mm open position. Installation and user instructions manual dated 8th January 2014, reference: NS-4. Issue 1. The appliance must be fitted with a permanent stop to prevent closure of the secondary air supply control beyond the 7 mm open position. Wood logs[^f01000]
Chesneys 4 Series (4.6 kW) Stoves: Flatford 4, Hampstead 4, Alpine 4 also sold as: Sunbeam 4, Dakota 4, Providence 4. Pacific 4 also sold as: Murano 4, Apollo 4. Chelsea 4 also sold as: Wellington 4, Guernsey 4, Belgravia 4 manufactured by Chesneys,194-200 Battersea Park Road, London, SW11 4ND Chesneys 4 series Instruction manual dated 7th December 2009, reference: CH4K-V4. The appliance must be fitted with a mechanical stop to prevent closure of the air control beyond the 34 mm open position. Chesneys 4 series Instruction manual dated 7th December 2009, reference: CH4K-V4. The appliance must be fitted with a mechanical stop to prevent closure of the air control beyond the 34 mm open position. Wood logs[^f01000]
Chesneys 6 Series (7 kW) Stoves: Flatford 6, Barrington 6, Petworth 6, Hampstead 6, Alpine 6 also sold as: Sunbeam 6, Dakota 6, Providence 6 and the Chelsea 6 also sold as: Wellington 6, Guernsey 6, Belgravia 6 manufactured by Chesneys, 194-200 Battersea Park Road, London, SW11 4ND Chesneys 6 series Instruction manual dated 7th December 2009, reference: CH6K-V4. The appliance must be fitted with a mechanical stop to prevent closure of the air control beyond the 10 mm open position. Chesneys 6 series Instruction manual dated 7th December 2009, reference: CH6K-V4. The appliance must be fitted with a mechanical stop to prevent closure of the air control beyond the 10 mm open position. Wood logs[^f01000]
Classic model 25, 35, 40, 49, and 60 wood pellet boilers manufactured by Hargassner GmbH, Gunderding 8, A-4952, Weng, Austria The manufacturer’s installation manual for the Classic Pellet Boilers reference: No. 22, Pellet Boilers, Type Classic 25, 31, 35, 40, 49, 60, reference: BA Classic 25L-60L Nr 21 0508 The manufacturer’s installation manual for the Classic Pellet Boilers reference: No. 22, Pellet Boilers, Type Classic 25, 31, 35, 40, 49, 60, reference: BA Classic 25L-60L Nr 21 0508 Wood pellets[^f01000]
Clean Air Systems CAS 200, 400 and 600 handfed airheaters manufactured by Inventair Ltd, Lancaster Road, Carnaby Industrial Estate, Bridlington, East Yorkshire, YO15 3QY To be operated in accordance with the Handbook for CAS hand fired airheater range dated January 2011, reference: 24600H version 1 To be operated in accordance with the Handbook for CAS hand fired airheater range dated January 2011, reference: 24600H version 1 Softwood, hardwood, medium density fibreboard (MDF) or chipboard offcuts[^f01000]
Clean Air Systems CAS 300 Max airheater and cyclone manufactured by Inventair Ltd, Lancaster Road, Carnaby Industrial Estate, Bridlington, East Yorkshire, YO15 3QY To be operated in accordance with the Handbook for CAS 300 Max airheater range dated January 2011, reference: 300A version 1 To be operated in accordance with the Handbook for CAS 300 Max airheater range dated January 2011, reference: 300A version 1 Softwood, hardwood, medium density fibreboard (MDF) or chipboard offcuts[^f01000]
Cleanburn CB900 Inset & Cleanburn CB900 Sønderskoven Inset, Wood burning stoves manufactured by Hunter Stoves Limited, Trevilla Park, Slaughterbridge, Camelford, Cornwall, PL32 9TT Instruction manual dated 17th January 2012, reference: JINHCN09 Slider Stop Rev A. Instruction manual dated 24th January 2012, reference: JINHCN09 Rev F. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 20% open position. Instruction manual dated 17th January 2012, reference: JINHCN09 Slider Stop Rev A. Instruction manual dated 24th January 2012, reference: JINHCN09 Rev F. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 20% open position. Wood logs⁽¹⁾
Cleanburn Inset Sønderskoven 8 multi-fuel inset stove manufactured by Hunter Stoves Limited Trevilla Park, Slaughterbridge, Camelford, Cornwall, PL32 9TT Installation and Operating Instructions manual dated 20th March 2012, reference: JINCN09 RevF. Modification instructions dated 25th September 2013, reference: JINHCN09 Slider Stop Rev B. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 20% open position. Installation and Operating Instructions manual dated 20th March 2012, reference: JINCN09 RevF. Modification instructions dated 25th September 2013, reference: JINHCN09 Slider Stop Rev B. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 20% open position. Wood logs[^f01000]
Cleanburn R4 manufactured by Hunter Stoves Limited, Trevilla Park, Slaughterbridge, Camelford, Cornwall, PL32 9TT Instruction manual dated 2nd December 2011, reference: JINCLR04 Rev E. Instruction manual dated 5th December 2011, reference: JINCLR04SCK rev B. The appliance must be fitted with smoke control area kit JCLR0401. Instruction manual dated 2nd December 2011, reference: JINCLR04 Rev E. Instruction manual dated 5th December 2011, reference: JINCLR04SCK rev B. The appliance must be fitted with smoke control area kit JCLR0401. Wood logs[^f01000]
Cleanburn R5 inset stove manufactured by Hunter Stoves Ltd, Trevilla Park, Slaughterbridge, Camelford, Cornwall, PL32 9TT Instruction manual dated 10th December 2012, reference: JINCLR05 Rev B. Instruction manual dated 6th July 2012, reference: JINCLR05SCK rev A. The appliance must be fitted with smoke control area kit JCLR0501. Instruction manual dated 10th December 2012, reference: JINCLR05 Rev B. Instruction manual dated 6th July 2012, reference: JINCLR05SCK rev A. The appliance must be fitted with smoke control area kit JCLR0501. Wood logs[^f01000]
Cleanburn R6 inset stove manufactured by Hunter Stoves Ltd, Trevilla Park, Slaughterbridge, Camelford, Cornwall, PL32 9TT Instruction manual dated 10th December 2012, reference: JINCLR06 rev B. Instruction manual dated 6th July 2012, reference: JINCLR05SCK rev A. The appliance must be fitted with smoke control area kit JCLR0501. Instruction manual dated 10th December 2012, reference: JINCLR06 rev B. Instruction manual dated 6th July 2012, reference: JINCLR05SCK rev A. The appliance must be fitted with smoke control area kit JCLR0501. Wood logs[^f01000]
Cleanburn Sonderskoven 5 inset stove manufactured by Hunter Stoves Ltd, Trevilla Park, Slaughterbridge, Camelford, Cornwall, PL32 9TT Instruction manual dated 4th October 2012, reference: JINHCN05 Rev B. The valve plate adjusted by the secondary air control must contain six 5 mm holes. Instruction manual dated 4th October 2012, reference: JINHCN05 Rev B. The valve plate adjusted by the secondary air control must contain six 5 mm holes. Wood logs[^f01000]
Clearburn Junior SE stove manufactured by Dean Forge Limited, Dean Prior, Buckfastleigh, Devon, TQ11 0LS Instruction manual dated March 2012, reference: JRSE Issue 1. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond 83 mm open position. Instruction manual dated March 2012, reference: JRSE Issue 1. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond 83 mm open position. Wood logs[^f01000]
Clearview models 650 and 750 manufactured by Clearview Stoves of More Works, Bishops Castle, Shropshire, SY9 5HH The manufacturer’s instructions dated 1st January 1993, reference: 1/42 The manufacturer’s instructions dated 1st January 1993, reference: 1/42 Wood logs which have been split, stacked and air-dried[^f01000]
Clearview Pioneer 400, Solution 400 and Pioneer Oven wood burning stoves manufactured by Clearview Stoves of More Works, Bishops Castle, Shropshire, SY9 5HH The manufacturer’s instructions entitled “Operating Instructions Clearview Vision/Vision Inset/Pioneer & Solution” dated 1st July 2006, reference: V1/42 stamped and signed “Smoke Control”. The applicance must be fitted with a tamperproof mechanical stop on the air slide/damper The manufacturer’s instructions entitled “Operating Instructions Clearview Vision/Vision Inset/Pioneer & Solution” dated 1st July 2006, reference: V1/42 stamped and signed “Smoke Control”. The applicance must be fitted with a tamperproof mechanical stop on the air slide/damper Air-dried wood logs[^f01000]
Clearview Vision 500 manufactured by Clearview Stoves of More Works, Bishops Castle, Shropshire, SY9 5HH The manufacturer’s instructions dated 1st January 1993, reference: V1/42 The manufacturer’s instructions dated 1st January 1993, reference: V1/42 Wood logs which have been split, stacked and air-dried[^f01000]
CLM Vesuvio 400kW stone wood-fired automatic pizza oven manufactured by CLM Bakery System srl, Via Monteli, 3 – 33092 Meduno (PN), Italy and previously known as the Vesuvio 400kW automatic pizza oven manufactured by CLM srl, Via I Maggio 35, 31043 Fontanelle (Treviso), Italy Instruction manual dated 25th July 2013 with reference “Manual English Review 2.1”. Instruction manual dated 25th July 2013 with reference “Manual English Review 2.1”. ‘CalorPan’ 100% beech briquette, octagonal section, length 260-300 mm, width and height 75-90 mm manufactured from dried beech sawdust[^f01000] or ‘Eden Beech Wood Briquettes’ that are cylindrical and of length 247-273 mm and have a diameter of 95 mm manufactured from dried beech sawdust[^f01000]
Contura 510, Contura 520T, Contura 550, Contura 550A, Contura 550W, Contura 560T, Contura 560K, Contura 570, Contura 580, Contura 585, Contura 590, Contura T, all manufactured by Nibe AB, Box 134, SE-285 23 Markaryd, Sweden Installation instruction reference: IAV SE/EX 0726-6 611821 Lighting instruction BAV SE/EX 0717-2 611820. A permanent stop must be in place on the air inlet to prevent closure beyond the 20% open position. Installation instruction reference: IAV SE/EX 0726-6 611821 Lighting instruction BAV SE/EX 0717-2 611820. A permanent stop must be in place on the air inlet to prevent closure beyond the 20% open position. Untreated dry wood with a maximum moisture content of 20%
Contura 556 wood-burning stove manufactured by Nibe AB, Box 134, SE-285 23 Markaryd, Sweden User manual dated 20th October 2011, reference: 611 820 BAV C500 SE/EX – 6. Installation instruction manual dated 14th November 2012, reference: 811116 IAV SE-EX C556 – 2. Supplementary instruction manual dated August 2011, reference: 811142 BAV GB – 3. The appliance must be fitted with a system to prevent closure of the air control vent beyond the 20% open position. User manual dated 20th October 2011, reference: 611 820 BAV C500 SE/EX – 6. Installation instruction manual dated 14th November 2012, reference: 811116 IAV SE-EX C556 – 2. Supplementary instruction manual dated August 2011, reference: 811142 BAV GB – 3. The appliance must be fitted with a system to prevent closure of the air control vent beyond the 20% open position. Wood logs[^f01000]
Contura 580W manufactured by Nibe AB, Box 134, SE-285 23 Markaryd, Sweden Installation instruction reference: IAV SE/EX 0740-1 511911. A permanent stop must be in place on the air inlet to prevent closure beyond the 20% open position. Installation instruction reference: IAV SE/EX 0740-1 511911. A permanent stop must be in place on the air inlet to prevent closure beyond the 20% open position. Untreated dry wood with a maximum moisture content of 20%
Contura 586 wood-burning stove manufactured by Nibe AB, Box 134, SE-285 23 Markaryd, Sweden User manual dated 20th October 2011, reference: 611 820 BAV C500 SE/EX – 6. Installation instruction manual dated 15th November 2012, reference: 811117 1AV SE-EX C586 – 2. Supplementary instruction manual dated August 2011, reference: 811142 BAV GB – 3. The appliance must be fitted with a system to prevent closure of the air control vent beyond the 20% open position. User manual dated 20th October 2011, reference: 611 820 BAV C500 SE/EX – 6. Installation instruction manual dated 15th November 2012, reference: 811117 1AV SE-EX C586 – 2. Supplementary instruction manual dated August 2011, reference: 811142 BAV GB – 3. The appliance must be fitted with a system to prevent closure of the air control vent beyond the 20% open position. Wood logs[^f01000]
Contura 750 manufactured by Nibe AB, Box 134, SE-285 23 Markaryd, Sweden Instruction manual reference: 811064 BAV SE-EX C750/780-1. The appliance must be fitted with a mechanical stop to prevent closure beyond the 28% open position. Instruction manual reference: 811064 BAV SE-EX C750/780-1. The appliance must be fitted with a mechanical stop to prevent closure beyond the 28% open position. Wood logs[^f01000]
Contura 750A manufactured by Nibe AB, Box 134, SE-285 23 Markaryd, Sweden Instruction manual reference: 811064 BAV SE-EX C750/780-1. The appliance must be fitted with a mechanical stop to prevent closure beyond the 28% open position. Instruction manual reference: 811064 BAV SE-EX C750/780-1. The appliance must be fitted with a mechanical stop to prevent closure beyond the 28% open position. Wood logs[^f01000]
Contura 780 manufactured by Nibe AB, Box 134, SE-285 23 Markaryd, Sweden Instruction manual reference: 811064 BAV SE-EX C750/780-1. The appliance must be fitted with a mechanical stop to prevent closure beyond the 28% open position. Instruction manual reference: 811064 BAV SE-EX C750/780-1. The appliance must be fitted with a mechanical stop to prevent closure beyond the 28% open position. Wood logs[^f01000]
Contura 810, 820 T, 850, 860 T, and 880 manufactured by Nibe AB, Box 134, SE-285 23 Markaryd, Sweden Instruction manual dated 28th June 2011, reference: 811118 BAV SE-EX C800-1. Supplementary operating instructions dated June 2011, reference: 811142 BAV GB-2. The appliance must be fitted with a mechanical stop to prevent air control closure beyond the 38% open position. Instruction manual dated 28th June 2011, reference: 811118 BAV SE-EX C800-1. Supplementary operating instructions dated June 2011, reference: 811142 BAV GB-2. The appliance must be fitted with a mechanical stop to prevent air control closure beyond the 38% open position. Wood logs[^f01000]
Contura i4 FS Classic and Modern multi-fuel stoves manufactured by Nibe AB, Box 134, SE-285 23 Markaryd, Sweden Instruction manual dated 3rd February 2012, reference 811164 BAV C i4 SE-EX-1. Installation instruction manual dated 3rd June 2013, reference: 811191 IAV Ci4 FS GB-1. Supplementary operating instruction manual dated August 2011, reference: 811142 BAV GB – 4. The appliance must be fitted with a system to prevent closure of the air control vent beyond the 30% open position. Instruction manual dated 3rd February 2012, reference 811164 BAV C i4 SE-EX-1. Installation instruction manual dated 3rd June 2013, reference: 811191 IAV Ci4 FS GB-1. Supplementary operating instruction manual dated August 2011, reference: 811142 BAV GB – 4. The appliance must be fitted with a system to prevent closure of the air control vent beyond the 30% open position. Wood logs[^f01000]
Contura i4 Modern and Contura i4 Classic manufactured by Nibe AB, Box 134, SE-285 23 Markaryd, Sweden Instruction manual dated 4th July 2011, reference: 811136 BAV C i4 GB-1. Supplementary operating instructions dated June 2011, reference: 811142 BAV GB-2. The appliance must be fitted with a mechanical stop to prevent closure beyond the 28% open position. Instruction manual dated 4th July 2011, reference: 811136 BAV C i4 GB-1. Supplementary operating instructions dated June 2011, reference: 811142 BAV GB-2. The appliance must be fitted with a mechanical stop to prevent closure beyond the 28% open position. Dry wood logs[^f01000]
Contura i5 Panorama and i5 Double Door wood-burning insert stoves manufactured by Nibe AB, Box 134, SE-285 23 Markaryd, Sweden Installation and lighting instruction manual dated November 2012, reference: 811175 IAC SE-EX Ci5-5. Additional installation instruction manual dated 14th September 2012, reference: 811188 Kompletteranda IAV Ci5 – 2. Supplementary instruction manual dated August 2011, reference: 811142 BAV GB – 4. The appliance must be fitted with a system to prevent closure of the air control vent beyond the 30% open position. Installation and lighting instruction manual dated November 2012, reference: 811175 IAC SE-EX Ci5-5. Additional installation instruction manual dated 14th September 2012, reference: 811188 Kompletteranda IAV Ci5 – 2. Supplementary instruction manual dated August 2011, reference: 811142 BAV GB – 4. The appliance must be fitted with a system to prevent closure of the air control vent beyond the 30% open position. Wood logs[^f01000]
Contura i30, i31, i40, i41 wood burning inset appliances manufactured by Nibe AB, Box 134, SE-285 23 Markaryd, Sweden Instruction manual dated 14th June 2013, reference: 811212 BAV SE-EX Ci30/Ci40-1. Supplementary operating instruction manual dated January 2014, reference: 811142 BAV GB–5. The appliance must be fitted with a mechanical stop to prevent air control closure beyond the 27% open position. Instruction manual dated 14th June 2013, reference: 811212 BAV SE-EX Ci30/Ci40-1. Supplementary operating instruction manual dated January 2014, reference: 811142 BAV GB–5. The appliance must be fitted with a mechanical stop to prevent air control closure beyond the 27% open position. Wood logs[^f01000]
Corsair 300HW, 500HW and 750HW boilers, manufactured by Erithglen Limited The manufacturer’s instructions, reference: 001 August 1985. The manufacturer’s instructions, reference: 001 August 1985. Any fuel specified in the manufacturer’s instructions
Coseyfire CF001SE manufactured by Stove World UK Limited, Unit 24 Folly Farm, Ramsdell, Tadley, RG26 5RJ Installation and Operating Instructions dated April 2014, reference: Version 1.0. The appliance must be fitted with a modified secondary air supply that is fixed in the fully open position. Installation and Operating Instructions dated April 2014, reference: Version 1.0. The appliance must be fitted with a modified secondary air supply that is fixed in the fully open position. Wood logs[^f01000]
Country Hearth EC1100 wood-burning stove manufactured by United States Stove Company, 227 Industrial Park Rd, South Pittsburg, TN 37380, USA Instruction manual dated October 2014, reference: 852290. The appliance must be fitted with a mechanical stop to prevent air control closure beyond the 12mm open position. Instruction manual dated October 2014, reference: 852290. The appliance must be fitted with a mechanical stop to prevent air control closure beyond the 12mm open position. Wood logs[^f01000]
Country Hearth EC410 wood- burning stove manufactured by United States Stove Company, 227 Industrial Park Rd, South Pittsburg, TN 37380, USA Instruction manual dated October 2014, reference: 852292 Instruction manual dated October 2014, reference: 852292 Wood logs[^f01000]
Cove 2 SR manufactured by A.J.Wells & Sons Ltd of Bishops Way, Newport, Isle of Wight, PO30 5WS Instruction manual dated July 2009, reference: Cove2SR 07.09 Iss B. A permanent stop must be in place on air control to prevent closure beyond 14 mm from the fully closed position. Instruction manual dated July 2009, reference: Cove2SR 07.09 Iss B. A permanent stop must be in place on air control to prevent closure beyond 14 mm from the fully closed position. Dry and split wood logs of a maximum length of 23 cm[^f01000]
Crator JS5500 multi-fuel stove manufactured by James Smellie Limited, Unit N, Leona Industrial Estate, Nimmings Road, Halesowen, West Midlands, B62 9JQ Instruction manual dated June 2012, reference: Crator multi-fuel stove instruction manual Issue 1 Instruction manual dated June 2012, reference: Crator multi-fuel stove instruction manual Issue 1 Wood logs[^f01000]
Cronspisen stove, using the five channel chimney system, manufactured by Cronspisen Produktion AB The manufacturer’s instructions dated January 1992, reference: Serial No. UM 351B The manufacturer’s instructions dated January 1992, reference: Serial No. UM 351B Wood logs which have been split, stacked and air-dried[^f01000]
CTC Ecoflex 15 and 20 manufactured by Enertech AB, Box 313, S-341 26 Ljungby, Sweden The manufacturer’s instructions dated 20th February 2007, reference: 161 505 27 06/1 The manufacturer’s instructions dated 20th February 2007, reference: 161 505 27 06/1 Wood pellets[^f01000]
D’Alessandro GSA 130 airheater manufactured by D’Alessandro Termomeccanica, Contrada Cerreto, 55, 66010 Miglianico, Chieti, Italy Instruction manual dated 26th June 2012, reference: 2.0-1-QGSA130XEN0612 Instruction manual dated 26th June 2012, reference: 2.0-1-QGSA130XEN0612 Wood chips[^f01000]
D’Alessandro Termomeccanica CS and CSA 130, 180, 230 and 300 manufactured by D’Alessandro Termomeccanica, Contrada Cerreto, 55, 66010 Miglianico, Chieti, Italy Instruction manual dated February 2009, reference: Ver. 2.0 - QCSA2000XEN0209 [UK SMOKE CONTROL] Instruction manual dated February 2009, reference: Ver. 2.0 - QCSA2000XEN0209 [UK SMOKE CONTROL] Wood pellets[^f01000]
D’Alessandro Termomeccanica CS and CSA 400, 500, 650, 800, 950, 1300, 1650 and 2000 kW manufactured by D’Alessandro Termomeccanica, Contrada Cerreto, 55, 66010 Miglianico, Chieti, Italy Instruction manual dated February 2009, reference: Ver. 2.0 - QCSA2000XEN0209 [UK SMOKE CONTROL]. The optional multi-cyclone must be fitted. Instruction manual dated February 2009, reference: Ver. 2.0 - QCSA2000XEN0209 [UK SMOKE CONTROL]. The optional multi-cyclone must be fitted. Wood pellets[^f01000]
D’Alessandro Termomeccanica CS and CSA boilers 40, 60, 80 and 100 kW manufactured by D’Alessandro Termomeccanica, Contrada Cerreto, 55, 66010 Miglianico, Chieti, Italy Instruction manual dated February 2009, reference: Ver. 2.0 - QCSA100XXIT0209 [UK SMOKE CONTROL] Instruction manual dated February 2009, reference: Ver. 2.0 - QCSA100XXIT0209 [UK SMOKE CONTROL] Wood pellets[^f01000]
D’Alessandro Termomeccanica CSI 20 kW manufactured by D’Alessandro Termomeccanica, Contrada Cerreto, 55, 66010 Miglianico, Chieti, Italy Instruction manual dated February 2009, reference: Ver. 2.0 - QCSA100XXIT0209 [UK SMOKE CONTROL] Instruction manual dated February 2009, reference: Ver. 2.0 - QCSA100XXIT0209 [UK SMOKE CONTROL] Wood pellets[^f01000]
Dean Stoves Clearburn Slimline 5 SE multifuel stove manufactured by Dean Forge Fabrication Ltd, Dean Prior, Buckfastleigh, Devon, TQ11 0LS Instruction manual dated 25th April 2014, reference: SL5SE issue 1. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 15 mm open position. Instruction manual dated 25th April 2014, reference: SL5SE issue 1. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 15 mm open position. Wood logs[^f01000]
Dean Stoves Clearburn Small SE multifuel stove manufactured by Dean Forge Fabrication Ltd, Dean Prior, Buckfastleigh, Devon, TQ11 0LS Instruction manual dated 25th April 2014, reference: CBS8SE issue 1. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 15 mm open position. Instruction manual dated 25th April 2014, reference: CBS8SE issue 1. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control beyond the 15 mm open position. Wood logs[^f01000]
Dean Stoves Dartmoor 5 SE stove manufactured by Dean Forge Limited, Dean Prior, Buckfastleigh, Devon, TQ11 0LS Instruction manual dated March 2012, reference: DM5 Issue 1. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 30% open position. Instruction manual dated March 2012, reference: DM5 Issue 1. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 30% open position. Wood logs⁽¹⁾
Dean Stoves Dartmoor 6 SE Wood Burning Stove manufactured by Dean Forge Limited, Dean Prior, Buckfastleigh, Devon, TQ11 0LS Operating instruction manual dated 2nd July 2013, reference: DM6 issue 1. The appliance must be fitted with a mechanical stop to prevent secondary air spin wheel control closure beyond the 40% open position. Operating instruction manual dated 2nd July 2013, reference: DM6 issue 1. The appliance must be fitted with a mechanical stop to prevent secondary air spin wheel control closure beyond the 40% open position. Wood logs[^f01000]
Dean Stoves Dartmoor W5 SE Wood Burning Stove manufactured by Dean Forge Limited, Dean Prior, Buckfastleigh, Devon, TQ11 0LS Operating instruction manual dated 2nd July 2013, reference: DMW5 issue 1. The appliance must be fitted with a mechanical stop to prevent secondary air spin wheel control closure beyond the 40% open position. Operating instruction manual dated 2nd July 2013, reference: DMW5 issue 1. The appliance must be fitted with a mechanical stop to prevent secondary air spin wheel control closure beyond the 40% open position. Wood logs[^f01000]
Dean Stoves Hembury 5 SE Wood Burning Stove manufactured by Dean Forge Limited, Dean Prior, Buckfastleigh, Devon, TQ11 0LS Operating instruction manual dated 2nd July 2013, reference: HEM5SE issue. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 83 mm open position. Operating instruction manual dated 2nd July 2013, reference: HEM5SE issue. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 83 mm open position. Wood logs[^f01000]
Dean Stoves Hembury 8 SE multifuel stove manufactured by Dean Forge Fabrication Ltd, Dean Prior, Buckfastleigh, Devon, TQ11 0LS Instruction manual dated 25th April 2014, reference: HEM8SE issue 1. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 8 mm open position. Instruction manual dated 25th April 2014, reference: HEM8SE issue 1. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 8 mm open position. Wood logs[^f01000]
Dean Stoves Hembury Slimline 5 SE multifuel stove manufactured by Dean Forge Fabrication Ltd, Dean Prior, Buckfastleigh, Devon, TQ11 0LS Instruction manual dated 25th April 2014, reference: HEMSL5SE issue 1. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 8 mm open position. Instruction manual dated 25th April 2014, reference: HEMSL5SE issue 1. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 8 mm open position. Wood logs[^f01000]
Dean Stoves Junior 105 SE Wood Burning Stove manufactured by Dean Forge Limited, Dean Prior, Buckfastleigh, Devon, TQ11 0LS Operating instruction manual dated May 2013, reference: JR105SE Issue 1. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 83 mm open position. Operating instruction manual dated May 2013, reference: JR105SE Issue 1. The appliance must be fitted with a mechanical stop to prevent secondary air control closure beyond the 83 mm open position. Wood logs[^f01000]
Defiant Encore manufactured by VCW International Limited The manufacturer’s instructions dated November 1991, reference: 200—8632 The manufacturer’s instructions dated November 1991, reference: 200—8632 Wood logs which have been split, stacked and air-dried[^f01000]
Design 800 Green, Wood Burning Stove, manufactured by Bodart & Gonay Limited, Rue De Lambinon, 3 Harze, Belgium, 4920 Instruction manual dated November 2011, reference: 07DH8000A. The appliance must be fitted with a UK kit for smokeless areas Design 800. Instruction manual dated November 2011, reference: 07DH8000A. The appliance must be fitted with a UK kit for smokeless areas Design 800. Wood logs[^f01000]
Desire 5, Desire 5 LS, Desire 6, Desire 6 LS, Desire 7 and Desire 7 LS multi-fuel stoves, manufactured by Broseley Fires Limited, First Floor, Unit B Knights Court, Archers Way, Battlefield Enterprise Park, Shrewsbury, SY1 3GA Installation and Operating Instruction manual dated 3rd December 2014, reference: Mar 14/GB Issue 4. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control slide beyond the 10mm open position. Installation and Operating Instruction manual dated 3rd December 2014, reference: Mar 14/GB Issue 4. The appliance must be fitted with a mechanical stop to prevent closure of the secondary air control slide beyond the 10mm open position. Wood logs[^f01000]
Di Lusso R4 manufactured by Hunter Stoves Limited, Trevilla Park, Slaughterbridge, Camelford, Cornwall, PL32 9TT Instruction manual dated 2nd December 2011, reference: JINDLU04 Rev E. Instruction manual dated 5th December 2011, reference: JINDLU04SCK rev B. The appliance must be fitted with smoke control area kit JDLU0401. Instruction manual dated 2nd December 2011, reference: JINDLU04 Rev E. Instruction manual dated 5th December 2011, reference: JINDLU04SCK rev B. The appliance must be fitted with smoke control area kit JDLU0401. Wood logs[^f01000]
Di Lusso R5 inset stove manufactured by Hunter Stoves Ltd, Trevilla Park, Slaughterbridge, Camelford, Cornwall, PL32 9TT Instruction manual dated 10th December 2012, reference: JINDLU05 Rev B. Additional instruction manual dated 6th July 2012, reference: JINDLU05SCK Rev A. The appliance must be fitted with smoke control area kit JDLU0501. Instruction manual dated 10th December 2012, reference: JINDLU05 Rev B. Additional instruction manual dated 6th July 2012, reference: JINDLU05SCK Rev A. The appliance must be fitted with smoke control area kit JDLU0501. Wood logs[^f01000]
Di Lusso R6 inset stove manufactured by Hunter Stoves Ltd, Trevilla Park, Slaughterbridge Camelford, Cornwall, PL32 9TT Instruction manual dated 10th December 2012, reference: JINDLU06 rev B. Instruction manual dated 6th July 2012, reference: JINDLU05SCK rev A. The appliance must be fitted with smoke control area kit JDLU0501. Instruction manual dated 10th December 2012, reference: JINDLU06 rev B. Instruction manual dated 6th July 2012, reference: JINDLU05SCK rev A. The appliance must be fitted with smoke control area kit JDLU0501. Wood logs[^f01000]
Dik Geurts Instyle 500, Dik Geurts Prostyle 500, Dik Geurts Instyle 550, and Dik Geurts Prostyle 550 5 kW inset roomheaters manufactured by DRU Verwarming B.V, Postbus 1021, 6920 BA, Duiven, Ratio 8, 6921 RW Duiven, The Netherlands Installation instruction manual dated March 2014, reference: DRU392187-409050-NL-NL-0614-5. User manual dated 19th June 2014, reference: DRU180452-363097-nl-NL-0614-3 1 Installation instruction manual dated March 2014, reference: DRU392187-409050-NL-NL-0614-5. User manual dated 19th June 2014, reference: DRU180452-363097-nl-NL-0614-3 1 Wood logs[^f01000]
Dik Geurts Instyle 600 and Dik Geurts Prostyle 600 5 kW inset roomheaters, and Dik Geurts Instyle 650 and Dik Geurts Prostyle 650 6kW inset roomheaters manufactured by DRU Verwarming B.V, Postbus 1021, 6920 BA, Duiven, Ratio 8, 6921 RW Duiven, The Netherlands Installation Instruction manual dated June 2014, reference: DRU392187-410127-NL-NL-0614-3. User manual dated 19th June 2014, reference: DRU180452-363097-nl-NL-0614-3. 1. Installation Instruction manual dated June 2014, reference: DRU392187-410127-NL-NL-0614-3. User manual dated 19th June 2014, reference: DRU180452-363097-nl-NL-0614-3. 1. Wood logs[^f01000]

Reading this document does not replace reading the official text published on legislation.gov.uk. Contains public sector information licensed under the Open Government Licence v3.0. We assume no responsibility for any inaccuracies arising from the conversion of the original CLML XML to this format.

This text is published under legislation.gov.uk's own terms of reuse, not a Legalize or public-domain licence. legislation.gov.uk
Open Government Licence v3.0 (attribution required)
© Crown and database right. Derived from content available under the Open Government Licence v3.0 from legislation.gov.uk.