Commission Delegated Regulation (EU) 2020/411 of 19 November 2019 amending Directive 2009/45/EC of the European Parliament and the Council on safety rules and standards for passenger ships, as regards the safety requirements for passenger ships engaged on domestic voyages (Text with EEA relevance)

Type Delegated Regulation
Publication 2020-03-19
State In force
Text As published
Department European Commission, MOVE
Source EUR-Lex
articles 2

This is the act as published. Later amendments are not folded into the text below: each one is a separate act in this repository and an entry in this law's history.

Reform history JSON API
  • .1 the ship’s designs and arrangements, as a whole, complies with the relevant prescriptive requirements in this chapter;
  • .2 the ship’s designs and arrangements, as a whole, have been reviewed and approved in accordance with Part F of the revised Chapter II-2 of SOLAS 1974, as amended;
  • .3 part(s) of the ship’s designs and arrangements have been reviewed and approved in accordance with the above mentioned Part F of the revised SOLAS Chapter II-2 and the remaining parts of the ship comply with the relevant prescriptive requirements of this chapter.

Regulation II-2/A/3: Definitions

1. Accommodation spaces are those spaces used for public spaces, corridors, lavatories, cabins, offices, hospitals, cinemas, games and hobbies rooms, barber shops, pantries containing no cooking appliances and similar spaces.
--- --- ---
2. ‘A’ class divisions are those divisions formed by bulkheads and decks which comply with the following: .1 they shall be constructed of steel or other equivalent material; .2 they shall be suitably stiffened; .3 they shall be insulated with approved non-combustible materials such that the average temperature of the unexposed side will not rise more than 140 °C above the original temperature, nor will the temperature, at any one point, including any joint, rise more than 180 °C above the original temperature, within the time listed below: class ‘A-60’ 60 minutes class ‘A-30’ 30 minutes class ‘A-15’ 15 minutes class ‘A-0’ 0 minutes .4 they shall be so constructed as to be capable of preventing the passage of smoke and flame to the end of the one-hour standard fire test; .5 The Administration of the flag State shall require a test of a prototype bulkhead or deck to ensure that it meets the above requirements for integrity and temperature rise in accordance with the ‘Fire Test Procedures Code’.
--- --- ---
3. Atriums are public spaces within a single main vertical zone spanning three or more open decks.
--- --- ---
4. ‘B’ class divisions are those divisions formed by bulkheads, decks, ceilings or linings which comply with the following: .1 they shall be so constructed as to be capable of preventing the passage of flame to the end of the first half hour of the standard fire test; .2 they shall have an insulation value such that the average temperature of the unexposed side will not rise more than 140 °C above the original temperature, nor will the temperature at any one point, including any joint, rise more than 225 °C above the original temperature within the time listed below: class ‘B-15’ 15 min class ‘B-0’ 0 min .3 they shall be constructed of approved non-combustible materials and all materials entering into the construction and erection of ‘B’ class divisions shall be non-combustible, with the exception that combustible veneers may be permitted provided they meet other requirements of this chapter; .4 the Administration of the flag State shall require a test of a prototype division to ensure that it meets the above requirements for integrity and temperature rise in accordance with the ‘Fire Test Procedures Code’.
--- --- ---
8. Cargo spaces are all spaces used for cargo (including cargo oil tanks) and trunks to such spaces.
--- --- ---
9. Central control station is a control station in which the following control and indicator functions are centralised: .1 fixed fire detection and alarm systems; .2 automatic sprinklers, fire detection and alarm systems; .3 fire door indicator panels; .4 fire doors closures; .5 watertight door indicator panels; .6 watertight door closures; .7 ventilation fans; .8 general/fire alarms; .9 communication systems including telephones; and .10 microphones to public address systems.
--- --- ---
10. ‘C’ class divisions are divisions constructed of approved non-combustible materials. They need meet neither requirements relative to the passage of smoke and flame nor limitations relative to the temperature rise. Combustible veneers are permitted provided they meet other requirements of this chapter.
--- --- ---
12. Closed ro-ro cargo spaces are ro-ro cargo spaces which are neither open ro-ro cargo spaces nor weather decks.
--- --- ---
13. Closed vehicle spaces are vehicle spaces which are neither open vehicle spaces nor weather decks.
--- --- ---
16. Continuous ‘B’ class ceilings or linings are those ‘B’ class ceilings or linings which terminate only at an ‘A’ or ‘B’ class division.
--- --- ---
17. Continuously manned central control station is a central control station which is continuously manned by a responsible member of the crew.
--- --- ---
18. Control stations are those spaces in which the ship’s radio or main navigating equipment or the emergency source of power is located or where the fire recording or fire control equipment is centralised.
--- --- ---
20. Dangerous goods are those goods referred to in the IMDG Code, as defined in SOLAS VII/1.1.
--- --- ---
22. Fire Safety Systems Code means the International Code for Fire Safety Systems adopted by Resolution MSC.98(73), as amended.
--- --- ---
23. Fire Test Procedures Code means the International Code for Application of Fire Test Procedures, 2010, adopted by Resolution MSC.307(88), as amended.
--- --- ---
24. Flashpoint is the temperature in degrees Celsius (closed cup test) at which a product will give off enough flammable vapour to be ignited, as determined by an approved flashpoint apparatus.
--- --- ---
26. Helideck is a purpose-built helicopter landing area located on a ship including all structure, fire-fighting appliances and other equipment necessary for the safe operation of helicopters.
--- --- ---
29. Low flame spread means that the surface thus described will adequately restrict the spread of flame, this being determined in accordance with the Fire Test Procedures Code.
--- --- ---
30. Machinery spaces are all machinery spaces of category A and all other spaces containing propelling machinery, boilers, oil fuel units, steam and internal combustion engines, generators and major electrical machinery, oil filling stations, refrigerating, stabilising, ventilation and air conditioning machinery, and similar spaces, and trunks to such spaces.
--- --- ---
31. Machinery spaces of category A are those spaces and trunks to such spaces which contain: .1 internal combustion machinery used for main propulsion; or .2 internal combustion machinery used for purposes other than main propulsion where such machinery has in the aggregate a total power output of not less than 375 kW; or .3 any oil-fired boiler or oil fuel unit, or any oil-fired equipment other than boilers, such as inert gas generators, incinerators, etc.
--- --- ---
32. Main vertical zones are those sections into which the hull, superstructure, and deckhouses are divided by ‘A’ class divisions, the mean length and width of which on any deck does not in general exceed 40 metres.
--- --- ---
33. Non-combustible material is a material which neither burns nor gives off flammable vapours in sufficient quantity for self-ignition when heated to approximately 750 °C, this being determined in accordance with the Fire Test Procedures Code. Any other material is a combustible material.
--- --- ---
34. Oil fuel unit is the equipment used for the preparation of oil fuel for delivery to an oil-fired boiler, or equipment used for the preparation for delivery of heated oil to an internal combustion engine, and includes any oil pressure pumps, filters and heaters dealing with oil at a pressure of more than 0,18 N/mm2.
--- --- ---
35. Open ro-ro cargo spaces are ro-ro cargo spaces either open at both ends, or open at one end and provided with adequate natural ventilation effective over the entire length through permanent openings in the side plating or deckhead, or from above, having a total area of at least 10 % of the total area of the space sides.
--- --- ---
36. Open vehicle spaces are those vehicle spaces either open at both ends or having an opening at one end and being provided with adequate natural ventilation effective over their entire length through permanent openings distributed in the side plating or deckhead or from above, having a total area of at least 10 % of the total area of the space sides.
--- --- ---
38. Prescriptive requirements mean the constructive characteristics, limiting dimensions or fire safety systems specified in this chapter.
--- --- ---
39. Public spaces are those portions of the accommodation which are used for halls, dining rooms, lounges and similar permanently enclosed spaces.
--- --- ---
40. Rooms containing furniture and furnishings of restricted fire risk are, for the purpose of Regulation II-2/C/9, those rooms containing furniture and furnishings of restricted fire risk (whether cabins, public spaces, offices or other types of accommodation) in which: .1 all case furniture such as desks, wardrobes, dressing tables, bureaux, dressers, is constructed entirely of approved non-combustible materials, except that a combustible veneer not exceeding 2 mm may be used on the working surface of such articles; .2 all free-standing furniture such as chairs, sofas, tables, is constructed with frames of non-combustible materials; .3 all draperies, curtains and other suspended textile materials have qualities of resistance to the propagation of flame not inferior to those of wool of mass 0,8 kg/m2, in accordance with the Fire Test Procedures Code; .4 all floor coverings have low flame spread characteristics; .5 all exposed surfaces of bulkheads, linings and ceilings have low flame-spread characteristics; and .6 all upholstered furniture has qualities of resistance to the ignition and propagation of flame in accordance with the Fire Test Procedures Code. .7 all bedding components have qualities of resistance to the ignition and propagation of flame, this being determined in accordance with the Fire Test Procedures Code.
--- --- ---
41. Ro-ro cargo spaces are spaces not normally subdivided in any way and extending to either a substantial length or the entire length of the ship in which motor vehicles with fuel in their tanks for their own propulsion and/or goods (packaged or in bulk, in or on rail or road cars, vehicles (including road and rail tankers), trailers, containers, pallets, dismountable tanks or in or on similar stowage units or other receptacles) can be loaded and unloaded normally in a horizontal direction.
--- --- ---
42. Ro-ro passenger ship means a passenger ship with ro-ro cargo spaces or special category spaces as defined in this Regulation II-2/A/3.
--- --- ---
45. Service spaces are those spaces used for galleys, pantries containing cooking appliances, lockers, mail and specie rooms, storerooms, workshops other than those forming part of the machinery spaces, and similar spaces and trunks to such spaces.
--- --- ---
46. Special category spaces are those enclosed vehicle spaces above or below the bulkhead deck, into and from which such vehicles can be driven and to which passengers have access. Special category spaces may be accommodated on more than one deck provided that the total overall clear height for vehicles does not exceed 10 metres.
--- --- ---
47. A standard fire test is the one defined in article 2 (zb) of Directive 2009/45/EC.
--- --- ---
49. Vehicle spaces are cargo spaces intended for the carriage of motor vehicles with fuel in their tanks for their own propulsion.
--- --- ---
50. Weather deck is a deck which is completely exposed to the weather from above and from at least two sides.
--- --- ---
53. Cabin balcony is an open deck space which is provided for the exclusive use of the occupants of a single cabin and has direct access from such a cabin.
--- --- ---
54. Fire damper means, for the purpose of implementing Regulation II-2/C/9, paragraph 7, a device installed in a ventilation duct which under normal conditions remains open allowing flow in the duct and is closed during a fire, preventing the flow in the duct to restrict the passage of fire. In using the above definition, the following terms may be associated: .1 automatic fire damper means a fire damper that closes independently in response to exposure to fire products; .2 manual fire damper means a fire damper that is intended to be opened or closed by the crew by hand at the damper itself; and .3 remotely operated fire damper means a fire damper that is closed by the crew through a control located at a distance away from the controlled damper.
--- --- ---
55. Smoke damper means, for the purpose of implementing Regulation II-2/C/9, paragraph 7, a device installed in a ventilation duct which under normal conditions remains open allowing flow in the duct and is closed during a fire, preventing the flow in the duct to restrict the passage of smoke and hot gases. A smoke damper is not expected to contribute to the integrity of a fire rated division penetrated by a ventilation duct. In using the above definition the following terms may be associated: .1 automatic smoke damper means a smoke damper that closes independently in response to exposure to smoke or hot gases; .2 manual smoke damper means a smoke damper intended to be opened or closed by the crew by hand at the damper itself; and .3 remotely operated smoke damper means a smoke damper that is closed by the crew through a control located at a distance away from the controlled damper.

PART B

PREVENTION OF FIRE AND EXPLOSION

Regulation II-2/B/4: Probability of ignition

1. Purpose

The purpose of this Regulation II-2/B/4 is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met:

  • .1 means shall be provided to control leaks of flammable liquids;
  • .2 means shall be provided to limit the accumulation of flammable vapours;
  • .3 the ignitability of combustible materials shall be restricted;
  • .4 ignition sources shall be restricted; and
  • .5 ignition sources shall be separated from combustible materials and flammable liquids.

2. Arrangements for oil fuel, lubricating oil and other flammable oils

2.1.   Limitations in the use of oil as fuel

The following limitations shall apply to the use of oil as fuel:

  • .1 Except as otherwise permitted by this paragraph, no oil fuel with a flashpoint of less than 60 °C shall be used.
  • .2 In emergency generators, oil fuel with a flashpoint of not less than 43 °C may be used.
  • .3 Subject to such additional precautions as it may consider necessary and on condition that the ambient temperature of the space in which such oil fuel is stored or used shall not be allowed to rise to within 10 °C below the flashpoint of the oil fuel, the Administration of the flag State may permit the use of oil fuel having a flashpoint of less than 60 °C but not less than 43 °C (e.g., for feeding the emergency fire pump’s engines and the auxiliary machines which are not located in the machinery spaces of category A), subject to the following:
  • .3.1 fuel oil tanks except those arranged in double bottom compartments shall be located outside of machinery spaces of category A;
  • .3.2 provisions for the measurement of oil temperature are provided on the suction pipe of the oil fuel pump;
  • .3.3 stop valves and/or cocks are provided on the inlet side and outlet side of the oil fuel strainers and;
  • .3.4 pipe joints of welded construction or of circular cone type or spherical type union joint are applied as much as possible.

The flashpoint of oils shall be determined by an approved closed cup method.

  • .5 In ships, to which part G of chapter II-1 is applicable, the use of oil fuel having a lower flashpoint than otherwise specified in subparagraph 2.1.1 is permitted.

2.2.   Arrangements for oil fuel

In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilisation of the oil fuel shall be such as to ensure the safety of the ship and persons on board and shall at least comply with the following provisions:

2.2.1.   Location of oil fuel systems

As far as practicable, parts of the oil fuel system containing heated oil under pressure exceeding 0,18 N/mm2 shall not be placed in a concealed position such that defects and leakage cannot readily be observed. The machinery spaces in way of such parts of the oil fuel system shall be adequately illuminated. By heated oil is meant oil the temperature of which after heating is higher than 60 °C or higher than the current flashpoint of the oil, if this is lower than 60 °C.

2.2.2.   Ventilation of machinery spaces

The ventilation of machinery spaces shall be sufficient under all normal conditions to prevent accumulation of oil vapour.

2.2.3.   Oil fuel tanks
2.2.3.1. Fuel oil, lubrication oil and other flammable oils shall not be carried in forepeak tanks.
--- --- ---
2.2.3.2. As far as practicable, oil fuel tanks shall be part of the ship’s structure and shall be located outside machinery spaces. Where oil fuel tanks, other than double bottom tanks, are necessarily located adjacent to or within machinery spaces, at least one of their vertical sides shall be contiguous to the machinery space boundaries, and shall preferably have a common boundary with the double bottom tanks, and the area of the tank boundary common with the machinery spaces shall be kept to a minimum. Where such tanks are situated within the boundaries of machinery spaces they shall not contain oil fuel having a flashpoint of less than 60 °C. The use of freestanding oil fuel tanks shall be avoided and shall be prohibited in machinery spaces.
--- --- ---
2.2.3.3. No oil fuel tank shall be situated where spillage or leakage therefrom can constitute a hazard by falling on heated surfaces.
--- --- ---
2.2.3.4. Every oil fuel pipe, which, if damaged, would allow oil to escape from a storage, settling or daily service tank, having a capacity of 500 litres or above, situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space in which such tanks are situated. In the special case of deep tanks situated in any shaft or pipe tunnel or similar space, valves on the tank shall be fitted but control in the event of fire may be effected by means of an additional valve on the pipe or pipes outside the tunnel or similar space. If such additional valve is fitted in the machinery space it shall be operated from a position outside this space. The controls for remote operation of the valve for the emergency generator fuel tank shall be in a separate location from the controls for remote operation of other valves located in machinery spaces.
--- --- ---
2.2.3.4a In ships having a gross tonnage of less than 500, fuel tanks above the double bottom shall be fitted with a cock or valve.
--- --- ---
2.2.3.5. Safe and efficient means of ascertaining the amount of oil fuel contained in any oil fuel tank shall be provided.
--- --- ---
2.2.3.5.1 Sounding pipes shall not terminate in any space where the risk of ignition of spillage from the sounding pipe might arise. In particular, they shall not terminate in passenger or crew spaces. As a general rule, sounding pipes shall not terminate in machinery spaces. However, where the Administration of the flag State considers that these latter requirements are impracticable, it may permit termination of sounding pipes in machinery spaces on condition that all the following requirements are met: .1 in addition, an oil-level gauge is provided meeting the requirements of subparagraph 2.2.3.5.2; .2 the sounding pipes terminate in locations remote from ignition hazards unless precautions are taken, such as the fitting of effective screens, to prevent the oil fuel in the case of spillage through the terminations of the sounding pipes from coming into contact with a source of ignition; .3 the termination of sounding pipes are fitted with self-closing blanking devices and with a small-diameter self-closing control cock located below the blanking device for the purpose of ascertaining before the blanking device is opened that oil fuel is not present. Provision shall be made as to ensure that any spillage of oil fuel through the control cock involves no ignition hazard.
--- --- ---
2.2.3.5.2 Other means of ascertaining the amount of oil fuel contained in any oil fuel tank may be permitted if such means do not require penetration below the top of the tank, and providing their failure or overfilling of the tanks will not permit release of fuel.
--- --- ---
2.2.3.5.3 Means prescribed in subparagraph 2.2.3.5.2 shall be maintained in the proper condition to ensure their continued accurate functioning in service.
2.2.4.   Prevention of overpressure

Provisions shall be made to prevent overpressure in any oil tank or in any part of the oil fuel system, including the filling pipes served by pumps on board. Any relief valves and air or overflow pipes shall discharge to a position where there is no risk of fire or explosion from the emergence of oils and vapour and shall not lead into crew spaces, passenger spaces nor into special category spaces, closed ro-ro cargo spaces, machinery spaces or similar spaces.

2.2.5.   Oil fuel piping
2.2.5.1. Oil fuel pipes and their valves and fittings shall be of steel or other approved material, except that restricted use of flexible pipes may be permitted. Such flexible pipes and end attachments shall be of approved fire-resisting materials of adequate strength. For valves, fitted to oil fuel tanks and which are under static pressure, steel or spheroidal-graphite cast iron may be accepted. However, ordinary cast iron valves may be used in piping systems, where the design pressure is lower than 7 bar and the design temperature is below 60 °C.
--- --- ---
2.2.5.2. All external high pressure fuel delivery lines between the high pressure fuel pumps and fuel injectors shall be protected with a jacketed piping system capable of containing fuel from a high pressure line failure. A jacketed pipe incorporates an outer pipe into which the high-pressure fuel pipe is placed forming a permanent assembly. The jacketed piping system shall include a means for collection of leakages and arrangements shall be provided for an alarm to be given in case of a fuel line failure.
--- --- ---
2.2.5.3. Oil fuel lines shall not be located immediately above or near units of high temperature including boilers, steam pipelines, exhaust manifolds, silencers or other equipment required to be insulated. As far as practicable, oil fuel lines shall be arranged far apart from hot surfaces, electrical installations or other sources of ignition and shall be screened or otherwise suitably protected to avoid oil spray or oil leakage onto the sources of ignition. The number of joints in such piping systems shall be kept to a minimum.
--- --- ---
2.2.5.4. Components of a diesel engine fuel system shall be designed considering the maximum peak pressure which will be experienced in service, including any high pressure pulses which are generated and transmitted back into fuel supply and spill lines by the action of fuel injection pumps. Connections within the fuel supply and spill lines shall be constructed having regard to their ability to prevent pressurised oil fuel leaks while in service and after maintenance.
--- --- ---
2.2.5.5. In multi-engine installations which are supplied from the same fuel source, means of isolating the fuel supply and spill piping to individual engines, shall be provided. The means of isolation shall not affect the operation of the other engines and shall be operable from a position not rendered inaccessible by a fire on any of the engines.
--- --- ---
2.2.5.6. Where the Administration of the flag State may permit the conveying of oil, combustible or other flammable liquids through accommodation, service spaces or control stations; the conveying pipes shall be of a material approved by the Administration having regard to the fire risk.
2.2.6.   Protection of high-temperature surfaces
2.2.6.1. All surfaces with temperatures above 220 °C which may be impinged as a result of a fuel system failure shall be properly insulated.
--- --- ---
2.2.6.2. Precautions shall be taken to prevent any oil that may escape under pressure from any pump, filter or heater from coming into contact with heated surfaces.

2.3.   Lubricating oil arrangements

2.3.1. The arrangements for the storage, distribution and utilisation of oil used in pressure lubrication systems shall be such as to ensure the safety of the ship and persons on board, and such arrangements in machinery spaces shall at least comply with the provisions of subparagraphs 2.2.1, 2.2.3.3, 2.2.3.4, 2.2.3.5, 2.2.4, 2.2.5.1, 2.2.5.3 and 2.2.6, except that: .1 this does not preclude the use of sight-flow glasses in lubricating systems provided that they are shown by test to have a suitable degree of fire resistance. If sight-flow glasses are used, the pipe shall be provided with valves in both ends. The valve at the lower end of the pipe shall be of a self-closing type; .2 sounding pipes may be authorised in machinery spaces; the requirements of subparagraphs 2.2.3.5.1.1 and 2.2.3.5.1.3 need not be applied on condition that the sounding pipes are fitted with appropriate means of closure.
--- --- ---
2.3.2. The provisions of subparagraph 2.2.3.4 shall also apply to lubricating oil tanks except those having a capacity less than 500 litres, storage tanks on which valves are closed during the normal operation of the ship or where it is determined that the unintended operation of a quick closing valve on the lubricating oil tank would endanger the safe operation of the main propulsion and essential auxiliary machinery.

2.4.   Arrangements for other flammable oils

The arrangements for the storage, distribution and utilisation of other flammable oils employed under pressure in power transmission systems, control and activating systems and heating systems shall be such as to ensure the safety of the ship and persons on board. In locations where means of ignition are present, such arrangements shall at least comply with the provisions of subparagraphs 2.2.3.3, 2.2.3.5, 2.2.5.3 and 2.2.6 and with the provisions of subparagraphs 2.2.4 and 2.2.5.1 in respect of strength and construction.

2.5.   Periodically unattended machinery spaces

In addition to the requirements of provisions of subparagraphs 2.1 to 2.4, the oil fuel and lubricating oil systems shall comply with the following:

  • .1 where daily service oil fuel tanks are filled automatically, or by remote control, means shall be provided to prevent overflow spillages. Other equipment which treats flammable liquids automatically, e.g. oil fuel purifiers, which, whenever practicable, shall be installed in a special space reserved for purifiers and their heaters, shall have arrangements to prevent overflow spillages;
  • .2 where daily service oil fuel tanks or settling tanks are fitted with heating arrangements, a high temperature alarm shall be provided if the flashpoint of the oil fuel can be exceeded.

3. Arrangements for gaseous fuel for domestic purpose

Gaseous fuel systems used for domestic purposes shall be approved by the Administration of the flag State. Storage of gas bottles shall be located on the open deck or in a well ventilated space which opens only to the open deck.

4. Miscellaneous items of ignition sources and ignitability

4.1.   Electric radiators

Electric radiators, if used, shall be fixed in position and so constructed as to reduce fire risks to a minimum. No such radiators shall be fitted with an element so exposed that clothing, curtains, or other similar materials can be scorched or set on fire by heat from the element.

4.2.   Waste receptacles

All waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom.

4.3.   Insulation surfaces protected against oil penetration

In spaces where penetration of oil products is possible, the surface of insulation shall be impervious to oil or oil vapours.

4.3.100 In spaces where there is a risk of oils splashing or oil vapour, e.g. in machinery spaces of category A, the surface of the insulating material shall be impermeable by oil and oil vapour. Where in referred ships there is covering by non-perforated steel plate or other non-combustible materials (not aluminium) which is the ultimate physical surface, this covering may be joined by seaming, riveting, etc.

4.4.   Primary deck coverings

Primary deck coverings, if applied within accommodation, cabin balconies, service spaces and control stations, shall be of an approved material which will not readily ignite, this being determined in accordance with the IMO Fire Test Procedure Code.

4.100   Pressurised gas containers:

All portable containers for gases which are compressed, liquefied or broken down under pressure, which may feed a possible fire, shall immediately after use be put in a suitable place above the bulkhead deck, from which there is direct access to open deck.

Regulation II-2/B/5: Fire growth potential

1. Purpose

The purpose of this Regulation II-2/B/5 is to limit the fire growth potential in every space of the ship. For this purpose, the following functional requirements shall be met:

  • .1 means of control for the air supply to the space shall be provided;
  • .2 means of control for flammable liquids in the space shall be provided; and
  • .3 the use of combustible materials shall be restricted.

2. Control of air supply and flammable liquid to the space

2.1.   Closing appliances and stopping devices of ventilation

2.1.1. The main inlets and outlets of ventilation systems shall be capable of being closed from outside the spaces being ventilated. The means of closing shall be easily accessible as well as prominently and permanently marked and shall indicate the operating position of the closing device.

2.2.   Means of control in machinery spaces

2.2.1. Means of control shall be provided for opening and closure of skylights, closure of openings in funnels which normally allow exhaust ventilation, and closure of ventilator dampers.
--- --- ---
2.2.2. Means of control shall be provided for stopping ventilating fans.
--- --- ---
2.2.3. Means of control shall be provided for stopping forced and induced draught fans, oil fuel transfer pumps, oil fuel unit pumps, lubricating oil service pumps, thermal oil circulating pumps and oil separators. However, paragraphs 2.2.4 and 2.2.5 of this Regulation II-2/B/5 need not apply to oily water separators.
--- --- ---
2.2.4. The controls required in paragraphs 2.2.1 to 2.2.3 and Regulation II-2/B/4, subparagraph 2.2.3.4 shall be located outside the space concerned, where they will not be cut off in the event of fire in the space they serve.
--- --- ---
2.2.5. Such controls and the controls for any required fire-extinguishing system shall be situated at one control position or grouped in as few positions as possible. Such positions shall have a safe access from the open deck.

3. Fire protection materials

3.1.   Use of non-combustible materials

3.1.1.   Insulating materials

Vapour barriers and adhesives used in conjunction with insulation, as well as insulation of pipe fittings for cold service systems need not be non-combustible, but they shall be kept to the minimum quantity practicable and their exposed surfaces shall have low flame spread characteristics.

3.1.2.   Ceilings and linings

Except in cargo spaces, mail rooms, baggage rooms, or refrigerated compartments of service spaces, all linings, grounds, draught stops, ceilings, and insulations shall be of non-combustible materials.

3.1.3.   Partial bulkheads and decks
3.1.3.1. Partial bulkheads or decks used to subdivide a space for utility or artistic treatment shall be of non-combustible materials.
--- --- ---
3.1.3.2. Linings, ceilings and partial bulkheads or decks used to screen or to separate adjacent cabin balconies shall be of non-combustible materials.

3.2.   Use of combustible materials

3.2.1.   General
3.2.1.1. "A’, ‘B’ or ‘C’ class divisions in accommodation and services spaces and cabin balconies which are faced with combustible materials, facings, mouldings, decorations and veneers shall comply with the provisions of paragraphs 3.2.2 to 3.2.4 and Regulation II-2/B/6. However, traditional wooden benches and wooden linings on bulkheads and ceilings are permitted in saunas and such materials need not be subject to the calculations prescribed in paragraphs 3.2.2 and 3.2.3. However, the provisions of paragraph 3.2.3 need not be applied to cabin balconies.
3.2.2.   Maximum calorific value of combustible materials

Veneers used on surfaces and linings covered by the requirements of paragraph 3.2.4 shall have a calorific value not exceeding 45 MJ/m2 of the area for the thickness used.

3.2.3.   Total volume of combustible materials
  • .1 The total volume of combustible facings, mouldings, decorations and veneers in any accommodation and service space shall not exceed a volume equivalent to 2,5 mm veneer on the combined area of the walls and ceilings. Furniture fixed to linings, bulkheads or decks need not be included in the calculation of the total volume of combustible materials.
  • .2 In the case of ships fitted with an automatic sprinkler system complying with the provisions of Regulation II-2/C/10, subparagraph 6.1.100, the above volume may include some combustible material used for erection of ‘C’ class divisions.
3.2.4.   Low flame-spread characteristics of exposed surfaces

The following surfaces shall have low flame-spread characteristics:

  • .1 exposed surfaces in corridors and stairway enclosures, and of bulkheads, wall and ceiling linings in all accommodation and service spaces (except saunas) and control stations;
  • .2 concealed or inaccessible spaces in accommodation, service spaces and control stations.
  • .3 exposed surfaces of cabin balconies, except for natural hard wood decking systems.

3.3.   Furniture in stairway enclosures

Furniture in stairway enclosures shall be limited to seating. It shall be fixed, limited to six seats on each deck in each stairway enclosure, be of restricted fire risk, and shall not restrict the passenger escape route. The Administration of the flag State may permit additional seating in the main reception area within a stairway enclosure if it is fixed, non-combustible and does not restrict the passenger escape route. Furniture shall not be permitted in passenger and crew corridors forming escape routes in cabin areas. In addition to the above, lockers of non-combustible material, providing storage for safety equipment required by the relevant Regulations, may be permitted. Drinking water dispensers and ice cube machines may be permitted in corridors provided they are fixed and do not restrict the width of the escape routes. This applies as well to decorative flower or plant arrangements, statues or other objects of art such as paintings and tapestries in corridors and stairways.

3.4.   Furniture and furnishings on cabin balconies

Furniture and furnishings on cabin balconies shall comply with subparagraphs 40.1, 40.2, 40.3, 40.6 and 40.7 of Regulation II-2/A/3 unless such balconies are protected by a fixed pressure water-spraying and fixed fire detection and fire alarm systems complying with regulations II-2/C/7, paragraph10 and regulation II-2/C/10, subparagraph 6.1.3.

Regulation II-2/B/6: Smoke generation potential and toxicity

1. Purpose

The purpose of this Regulation II-2/B/6 is to reduce the hazard to life from smoke and toxic products generated during a fire in spaces where persons normally work or live. For this purpose, the quantity of smoke and toxic products released from combustible materials, including surface finishes, during fire shall be limited.

2.1. Paints, varnishes and other finishes used on exposed interior surfaces shall not be capable of producing excessive quantities of smoke and toxic products, this being determined in accordance with the Fire Test Procedures Code.
--- --- ---
2.2. Paints, varnishes and other finishes used on exposed surfaces of cabin balconies, excluding natural hard wood decking systems, shall not be capable of producing excessive quantities of smoke and toxic products, this being determined in accordance with the Fire Test Procedures Code.
--- --- ---
3.1. Primary deck coverings, if applied within accommodation and service spaces and control stations, shall be of an approved material which will not give rise to toxic or explosive hazards at elevated temperatures, this being determined in accordance with the Fire Test Procedure Code.
--- --- ---
3.2. Primary deck coverings on cabin balconies shall not give rise to smoke, toxic or explosive hazards at elevated temperatures, this being determined in accordance with the Fire Test Procedures Code.

PART C

SUPPRESSION OF FIRE

Regulation II-2/C/7: Detection and alarm

1. Purpose

The purpose of this Regulation II-2/C/7 is to detect a fire in the space of origin and to provide alarm for safe escape and fire-fighting activity. For this purpose, the following functional requirements shall be met:

  • .1 fixed fire detection and fire alarm system installations shall be suitable for the nature of the space, fire growth potential and potential generation of smoke and gases;
  • .2 manually operated call points shall be placed effectively to ensure a readily accessible means of notification; and
  • .3 fire patrols shall provide an effective means of detecting and locating fires and alerting the navigation bridge and fire teams, where appropriate.

2. General requirements

2.2. The fixed fire detection and fire alarm systems shall be of an approved type, complying with the provisions of the Fire Safety Systems Code.

4. Protection of machinery spaces

4.1.   Installation

A fixed fire detection and fire alarm system of an approved type, in accordance with the provisions of subparagraph 2.2, shall be installed in:

  • .1 periodically unattended machinery spaces;
  • .2 machinery spaces where:
  • .2.1 the installation of automatic and remote control systems and equipment has been approved in lieu of continuous manning of the space; and
  • .2.2 the main propulsion and associated machinery including sources of main source of electrical power are provided with various degrees of automatic or remote control and are under continuous manned supervision from a control room; and
  • .3 enclosed spaces containing incinerators.

4.2.   Design

With regard to the fixed fire detection and fire alarm system required by subparagraphs 4.1.1, 4.1.2 and 4.1.3, the following shall apply:

The fire detection system shall be so designed and the detectors so positioned as to detect rapidly the onset of fire in any part of those spaces and under any normal conditions of operation of the machinery and variations of ventilation as required by the possible range of ambient temperatures. Except in spaces of restricted height and where their use is especially appropriate, detection systems using only thermal detectors shall not be permitted. The detection system shall initiate audible and visual alarms distinct in both respects from the alarms of any other system not indicating fire, in sufficient places to ensure that the alarms are heard and observed on the navigating bridge and by a responsible engineer officer. When the navigating bridge is unmanned, the alarm shall sound in a place where a responsible member of the crew is on duty.

After installation, the system shall be tested under varying conditions of engine operation and ventilation.

5. Protection of accommodation and service spaces and control stations

5.2.   Requirements for ships carrying more than 36 passengers

A fixed fire detection and fire alarm system of an approved type, complying with the requirements of subparagraph 2.2 shall be installed, so installed and arranged as to provide smoke detection in service spaces, control stations and accommodation spaces, including corridors and stairways. Smoke detectors need not be fitted in private bathrooms and galleys. Spaces having little or no fire risk such as voids, public toilets, carbon dioxide rooms and similar spaces need not be fitted with a fixed fire detection and alarm system.

5.3.   Requirements for ships carrying not more than 36 passengers

There shall be installed throughout each separate zone, whether vertical or horizontal, in all accommodation and service spaces and in control stations, except spaces which afford no substantial fire risk such as void spaces, sanitary spaces, etc., either:

  • .1 a fixed fire detection and fire alarm system of an approved type and complying with the requirements of paragraph 2.2 and so installed and arranged as to detect the presence of fire in such spaces and providing smoke detection in corridors, stairways and escape routes within accommodation spaces, or,
  • .2 an automatic sprinkler, fire detection and fire alarm system of an approved type complying with the requirements of Regulation II-2/C/10, subparagraph 6.1.100 or with the IMO guidelines for an approved equivalent sprinkler system as given in IMO Resolution A.800(19) and so installed and arranged as to protect such spaces and, in addition, a fixed fire detection and fire alarm system of an approved type and complying with the requirements of subparagraph 2.2 and so installed and arranged as to provide smoke detection in corridors, stairways and escape routes within accommodation spaces.

6. Protection of cargo spaces

A fixed fire detection and fire alarm system or a sample extraction smoke detection system shall be provided in any cargo space which is not accessible.

7. Manually operated call points

Manually operated call points complying with the Fire Safety Systems Code shall be installed throughout the accommodation spaces, service spaces and control stations. One manually operated call point shall be located at each exit. Manually operated call points shall be readily accessible in the corridors of each deck such that no part of the corridor is more than 20 metres from a manually operated call point.

8.1.   Fire patrols

For ships carrying more than 36 passengers, an efficient patrol system shall be maintained so that an outbreak of fire may be promptly detected. Each member of the fire patrol shall be trained to be familiar with the arrangements of the ship as well as the location and operation of any equipment he or she may be called upon to use.

8.3.   Two-way portable radiotelephone apparatus

Each member of the fire patrol shall be provided with a two-way portable radio telephone apparatus.

9. Fire alarm signalling systems

9.1. All ships shall at all times when at sea, or in port (except when out of service), be so manned or equipped as to ensure that any initial fire alarm is immediately received by a responsible member of the crew.
--- --- ---
9.2. The control panel shall be designed on the fail-safe principle, e.g. an open detector circuit shall cause an alarm condition.
--- --- ---
9.3. Ships carrying more than 36 passengers shall have the detection alarms for the systems required by subparagraph 5.2 centralised in a continuously manned central control station. In addition, controls for remote closing of the fire doors and shutting down the ventilation fans, shall be centralised in the same location. The ventilation fans shall be capable of reactivation by the crew at the continuously manned control station. The control panel in the central control station shall be capable of indicating open or closed positions of fire doors, closed or off status of the detectors, alarms and fans. The control panel shall be continuously powered and should have an automatic changeover to standby power supply in case of loss of normal power supply. The control panel shall be powered from the main source of electrical power and the emergency source of electrical power defined by Regulation II-1/D/42 unless other arrangements are permitted by the Regulations, as applicable.
--- --- ---
9.4. A special alarm, operated from the navigating bridge or fire control station, shall be fitted to summon the crew. This alarm may be part of the ship’s general alarm system but it shall be capable of being sounded independently of the alarm to the passenger spaces.

10. Protection of cabin balconies on passenger ships

A fixed fire detection and fire alarm system complying with the provisions of the Fire Safety Systems Code shall be installed on cabin balconies of ships to which regulation II-2/B/5, subparagraph 3.4 applies, when furniture and furnishings on such balconies are not as defined in subparagraphs 40.1, 40.2, 40.3, 40.6 and 40.7 of Regulation II-2/A/3.

Regulation II-2/C/8: Control of smoke spread

1. Purpose

The purpose of this Regulation II-2/C/8 is to control the spread of smoke in order to minimize the hazards from smoke. For this purpose, means for controlling smoke in atriums, control stations, machinery spaces and concealed spaces shall be provided.

2. Protection of control stations outside machinery spaces

Practicable measures shall be taken for control stations outside machinery spaces in order to ensure that ventilation, visibility and freedom from smoke are maintained so that, in the event of fire, the machinery and equipment contained therein may be supervised and continue to function effectively. Alternative and separate means of air supply shall be provided and air inlets of the two sources of supply shall be so disposed that the risk of both inlets drawing in smoke simultaneously is minimized. At the discretion of the Administration, such requirements need not apply to control stations situated on, and opening on to, an open deck or where local closing arrangements would be equally effective.

3. Release of smoke from machinery spaces

3.2. Suitable arrangements shall be made to permit the release of smoke in the event of fire, from the space to be protected.
--- --- ---
3.3. Means of control shall be provided for permitting the release of smoke and such controls shall be located outside the space concerned, where they will not be cut off in the event of fire in the space they serve.
--- --- ---
3.4. The controls required by paragraph 3.3 shall be situated at one control position or grouped in as few positions as possible. Such positions shall have a safe access from the open deck.

4. Draught stops

In accommodation and service spaces, control stations, corridors and stairways:

  • .1 air spaces enclosed behind ceilings, panelling or linings shall be suitably divided by close-fitting draught stops placed not more than 14 metres apart;
  • .2 in the vertical direction, such enclosed air spaces, including those behind linings of stairways, trunks, etc. shall be closed at each deck.

5. Smoke extraction systems in atriums

Atriums shall be equipped with a smoke extraction system. The smoke extraction system shall be activated by the required smoke detection system and be capable of manual control. The fans shall be sized such that the entire volume within the space can be exhausted in 10 min or less.

Regulation II-2/C/9: Containment of fire

1. Purpose

The purpose of this Regulation II-2/C/9 is to contain a fire in the space of origin. For this purpose, the following functional requirements shall be met:

  • .1 the ship shall be subdivided by thermal and structural boundaries;
  • .2 thermal insulation of boundaries shall have due regard to the fire risk of the space and adjacent spaces; and
  • .3 the fire integrity of the divisions shall be maintained at openings and penetrations.

2. Thermal and structural boundaries

2.2.1.   Main vertical zones and horizontal zones
2.2.1.1.1 In ships carrying more than 36 passengers, the hull, superstructure and deckhouses shall be subdivided into main vertical zones by A-60 class divisions. Steps and recesses shall be kept to a minimum but, where they are necessary, they shall also be A-60 class divisions. Where a category (5), (9) or (10) space defined in paragraph 2.2.3.2.2, is on one side or where fuel oil tanks are on both sides of the division, the standard may be reduced to A-0.
--- --- ---
2.2.1.1.2 For ships carrying not more than 36 passengers, the hull, superstructure and deckhouses in way of accommodation and service spaces shall be subdivided into main vertical zones by ‘A’ class divisions. These divisions shall have insulation values in accordance with the tables in paragraph 2.2.4.
--- --- ---
2.2.1.2. As far as practicable, the bulkheads forming the boundaries of the main vertical zones above the bulkhead deck shall be in line with watertight subdivision bulkheads situated immediately below the bulkhead deck. The length and width of main vertical zones may be extended to a maximum of 48 metres in order to bring the ends of main vertical zones to coincide with subdivision watertight bulkheads or in order to accommodate a large public space extending for the whole length of the main vertical zone provided that the total area of the main vertical zone is not greater than 1 600 m2 on any deck. The length or width of a main vertical zone is the maximum distance between the furthermost points of the bulkheads bounding it.
--- --- ---
2.2.1.3. Such bulkheads shall extend from deck to deck and to the shell or other boundaries.
--- --- ---
2.2.1.4. Where a main vertical zone is subdivided by horizontal ‘A’ class divisions into horizontal zones for the purpose of providing an appropriate barrier between a zone with sprinklers and a zone without sprinklers, the divisions shall extend between adjacent main vertical zone bulkheads and to the shell or exterior boundaries of the ship and shall be insulated in accordance with the fire insulation and integrity values given in table 9.4.
--- --- ---
2.2.1.5.1 On ships designed for special purposes, such as automobile or railroad car ferries where the provision of main vertical zone bulkheads would defeat the purpose for which the ship is intended, equivalent protection shall be obtained by dividing space in horizontal zones.
--- --- ---
2.2.1.5.2 However, in a ship with special category spaces, any such space shall comply with the applicable provisions of Regulation II-2/G/20 and in so far as such compliance would be inconsistent with compliance with other requirements of this part, the requirements of Regulation II-2/G/20 shall prevail.
2.2.2.   Bulkheads within a main vertical zone
2.2.2.1. For ships carrying more than 36 passengers all bulkheads which are not required to be ‘A’ class divisions shall be at least ‘B’ class or ‘C’ class divisions as prescribed in the tables in paragraph 2.2.3. All such divisions may be faced with combustible materials in accordance with the provisions of Regulation II-2/B/5, paragraph 3.
--- --- ---
2.2.2.2. For ships carrying not more than 36 passengers all bulkheads within accommodation and service spaces which are not required to be ‘A’ class divisions shall be at least ‘B’ class or ‘C’ class divisions as prescribed in the tables in paragraph 2.2.4. All such divisions may be faced with combustible materials in accordance with the provisions of Regulation II-2/B/5, paragraph 3. In addition, in ships carrying not more than 36 passengers all corridor bulkheads, where not required to be ‘A’ class, shall be ‘B’ class divisions which shall extend from deck to deck except: .1 when continuous ‘B’ class ceilings or linings are fitted on both sides of the bulkhead, the portion of the bulkhead behind the continuous ceiling or lining shall be of material which, in thickness and composition, is acceptable in the construction of ‘B’ class divisions, but which shall be required to meet ‘B’ class integrity standards only in so far as is reasonable and practicable; .2 in the case of a ship protected by an automatic sprinkler system complying with the provisions of Regulation II-2/C/10, subparagraph 6.1.100, the corridor bulkheads of ‘B’ class materials may terminate at a ceiling in the corridor provided such ceiling is of material which, in thickness and composition, is acceptable in the construction of ‘B’ class divisions. Notwithstanding the requirements of paragraph 2.2.4, such bulkheads and ceilings shall be required to meet ‘B’ class integrity standards only in so far as is reasonable and practicable. All doors and frames in such bulkheads shall be of non-combustible materials and shall be so constructed and erected as to provide substantial fire resistance.
--- --- ---
2.2.2.3. All bulkheads required to be ‘B’ class division, except corridor bulkheads prescribed in paragraph 2.2.2.2, shall extend from deck to deck and to the shell or other boundaries unless the continuous ‘B’ class ceilings or linings fitted on both sides of the bulkheads are at least of the same fire resistance as the bulkhead, in which case the bulkhead may terminate at the continuous ceiling or lining.
2.2.3.   Fire integrity of bulkheads and decks in ships carrying more than 36 passengers

Reading this document does not replace reading the official text published in the Official Journal of the European Union. We assume no responsibility for any inaccuracies arising from the conversion of the original to this format.

This text is published under EUR-Lex's own terms of reuse, not a Legalize or public-domain licence. EUR-Lex
Creative Commons Attribution 4.0 International (CC BY 4.0)
© European Union, https://eur-lex.europa.eu — Source: EUR-Lex (Publications Office of the European Union). Reused under the Creative Commons Attribution 4.0 International (CC BY 4.0) licence. Only EU legislation published in the printed Official Journal of the European Union is deemed authentic; consolidated texts are reproduced here for documentation purposes and have been reformatted to Markdown.